Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Stroke Cerebrovasc Dis ; 32(9): 107248, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37441892

RESUMO

BACKGROUND AND PURPOSE: Mechanical thrombectomy is less effective in patients aged 80 years or older. Our goal was to better understand the impact of age in general on recanalization rates and clinical outcome. METHODS: We performed a retrospective analysis of our prospective database of adult patients with acute ischemic stroke due to large vessel occlusions, who had undergone mechanical thrombectomy between 2019 and mid-2021. The cohort was categorized into five age groups: 18 - 49, 50 - 59, 60 - 69, 70 - 79 and ≥ 80 years. Our primary outcome measure was clinical outcome at three months after mechanical thrombectomy, measured by the mRS score. Secondary outcomes were procedure times and rates of successful recanalization, defined by mTICI ≥ 2b. RESULTS: Data of 264 patients were analyzed. There were no significant differences in procedure times (p = 0.46) or in rates of successful recanalization (p = 0.49) between age groups. There was a significant association of age and mRS score at three months (p < 0.0001): From youngest to oldest group, odds of functional independence (mRS ≤ 2) decreased (80.0% vs. 21.3%) and odds of death (mRS 6) increased (13.3% vs. 57.3%). Increasing age was significantly associated with lower rates of functional independence (OR 0.93; [95% CI 0.90 - 0.95]), higher rates of care dependency (OR 1.04; [95% CI 1.01 - 1.07]) and higher mortality rates (OR 1.06; [95% CI 1.04 - 1.09]). CONCLUSION: Higher age had no significant impact on recanalization times or recanalization rates but was strongly associated with worse clinical outcome after mechanical thrombectomy.

2.
J Stroke Cerebrovasc Dis ; 32(9): 107232, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37453214

RESUMO

OBJECTIVES: Intracranial atherosclerotic disease (ICAD) is a major cause of large vessel occlusion (LVO) in acute ischemic stroke (AIS). Our study aimed to analyze the effect of percutaneous transluminal angioplasty and stenting (PTAS) in patients with ICAD undergoing rescue treatment in terms of functional outcome and mortality rate at 90 days and compare the results to LVO with thromboembolic origins. MATERIALS AND METHODS: A retrospective review of a mechanical thrombectomy (MT) single center database from 01/2019 to 09/2021 was carried out using chart review and angiogram analysis. From 469 acute stroke patients, 361 patients were enroled in the study, of whom twenty-four (6.6%) were diagnosed with underlying ICAD and treated with angioplasty and stent reconstruction (PTAS) with a standardized medication protocol. Successful reperfusion, peri-procedural complications, and functional independence at 90 days were collected as outcomes. RESULTS: There was no difference in age or admission National Institutes of Health Stroke Scale (NIHSS). Onset to groin puncture (median 460 vs 277 min, P = 0.019) was significantly longer in the ICAD group. The procedure time (median 73 vs 60 min, P = 0.137) did not differ. Successful reperfusion was achieved in 95.8% of ICAD and 91.1% of the remaining patients (P = 0.445). Functional independence (mRS ≤ 2) at 90 days was achieved in 45.8% (11/24) and 42.7% (144/337, (P = 0.767)). The mortality rates (mRS 6) at 90 days were similar (29.2% vs 29.4% (P = 0.983)). CONCLUSION: Despite significantly longer treatment delays, the outcome and revascularization rates of ICAD patients were similar to the thromboembolic cohort. Our proposed protocol of PTAS and medication protocol in ICAD was effective with a similar safety profile as MT in general.


Assuntos
Arteriosclerose Intracraniana , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/terapia , Resultado do Tratamento , Trombectomia/efeitos adversos , Trombectomia/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Estudos Retrospectivos , Stents , Arteriosclerose Intracraniana/complicações , Arteriosclerose Intracraniana/diagnóstico por imagem , Arteriosclerose Intracraniana/terapia
3.
Eur Radiol ; 30(5): 2571-2582, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31974690

RESUMO

OBJECTIVES: Radio frequency (RF) pulses in magnetic resonance imaging (MRI) can interact with implanted devices and cause tissue damage. However, there are new devices that can safely perform measurements with liberal MRI conditions such as an RF transmission field B1+rms ≤ 2.0 µT. We investigated whether MRI in this case is limited for these technical reasons. METHODS: We selected typical MRI protocols of six body regions (brain, cervical spine, lumbar spine, knee, liver, heart) using two typical 1.5T MRI scanners. Overall, we adapted 62 sequences to B1+rms conditions and evaluated their diagnostic quality. For this, we measured signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), and geometric deviation (GD) as quality parameters, using phantom studies. For questionnaire studies, we selected pairs of original and adapted sequences in healthy volunteers. Blinded radiologists rated the images as single sequence rating and in direct comparison. RESULTS: Roughly one-third of the checked sequences were below the B1+rms limit. Here, 56 of the 62 adapted sequences showed at least the same image quality in single ratings. A reduction in SNR and/or CNR was found with 31 sequences and only one sequence with considerably increased GD. Especially, sequences with original high B1+rms values, PD sequences, and sequences of the Siemens knee and heart protocol were difficult to adapt, whereas most TSE and IR sequences had no clinical limitations. CONCLUSION: By limiting the transmission field to B1+rms ≤ 2.0 µT, clinically relevant MR sequences can be adapted with nearly no reduction in image quality. Despite limiting the transmission field, high-quality MR imaging is possible. We could derive strategies for adaptation. KEY POINTS: • Despite limiting the transmission field, high-quality MRI is possible. • We could derive strategies for adapting the sequences to B1+rms≤ 2.0 µT. • This enables high-quality MRI of different body regions for patients with AD.


Assuntos
Encéfalo/diagnóstico por imagem , Fígado/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Próteses e Implantes , Ondas de Rádio , Voluntários Saudáveis , Humanos
4.
Neuroradiology ; 57(8): 791-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25903428

RESUMO

INTRODUCTION: Different devices and techniques are available for endovascular treatment of ischemic stroke. In this in vitro study, we examined the stent-thrombus interaction and the influence of additional aspiration on the efficiency of mechanical thrombectomy with established stent retrievers. METHODS: Human blood thrombi were made in a Chandler loop. The thrombi were placed into the middle cerebral artery of a vascular silicon phantom. A programmable piston pump was used to acquire physiological flow in the model. Resistances were interposed to gain physiological pressure. The stent retrievers Trevo, Solitaire FR, Separator 3D, and Aperio were used to perform thrombectomy under direct visual control. For the additional aspiration, we used intermediate catheters. RESULTS: Ten attempts per device were made with and without aspiration under standardized conditions, a total of n = 80. For all thrombectomy maneuvers, it was demonstrated that the thrombus was pushed by the stent struts against the vessel wall and was retracted along it. The stent-thrombus interaction was only superficial for all devices. Using additional distal aspiration, the amount of distal embolism and rate of embolism in new territories was significantly lower than without. Moreover, additional aspiration reduced the number of recanalization maneuvers and the recanalization time. CONCLUSION: Distal aspiration with intermediate catheters increases the efficacy of mechanical thrombectomy with stent retrievers significantly. In contrary to earlier suggestions, the interaction between the thrombus and the stent retriever is only superficial, rather than an integration of the thrombus into the retriever. No significant differences between the proven devices could be shown in our model.


Assuntos
Prótese Vascular , Remoção de Dispositivo/instrumentação , Trombólise Mecânica/instrumentação , Stents , Trombose/fisiopatologia , Trombose/terapia , Velocidade do Fluxo Sanguíneo , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Sucção/instrumentação , Telas Cirúrgicas , Resultado do Tratamento
5.
World Neurosurg ; 182: e597-e601, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38052361

RESUMO

OBJECTIVE: Configuration changes of the parent artery (PA) after flow-diverter (FD) stent reconstruction, caused by the bending force of the device, may have an additional role in aneurysm occlusion as a result of the secondary alteration of intra-aneurysmal hemodynamics related to the geometry alteration of the vessel. To determine the degree of PA deformation and aneurysm occlusion rates after deployment of 2 different types of FD. METHODS: Patients treated with 2 different designs of cobalt-chromium braid (48 and 64 wire braid) structure FD were subject to analysis. Vascular angle changes at the level of the reconstructed segment immediately after FD deployment and at 1 year follow-up were measured and the potential relationship with aneurysmal occlusion rate was analyzed. RESULTS: Forty-two patients harboring 48 aneurysms were included in the present study. The aneurysms were divided into side wall (85.4%) and bifurcation types (14.6%). Twenty-six aneurysms were treated using the Pipeline FD (48 wire braid; 54.2%) and 22 using the Evolve FD (64 wire braid; 45.8%). Of the 48 aneurysms, 42 (87.5%) met the primary end point of complete occlusion at 12 months. The median postdeployment angle change was 7.04°± 4.59° for the Pipeline and 5.05°± 2.49° for the Evolve, whereas the median 12 months follow-up angle change was 15.49°± 10.99° and 10.01°± 8.83°, respectively. PA angle changes were significantly higher in the bifurcation group compared with the side wall group both during procedure and at 12 months follow-up. Angle change had a statistically nonsignificant association with complete aneurysm occlusion. CONCLUSIONS: PA deformation starts immediately after deployment and remodeling continues for 1 year after. Aneurysms located in the vessel bifurcation were more prone to PA straightening after FD deployment than were side wall aneurysms. Furthermore, Pipeline seemed to be more prone to inducing vascular deformation, compared with Evolve.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Stents , Artérias , Desenho de Equipamento , Embolização Terapêutica/métodos
6.
Diagnostics (Basel) ; 14(5)2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-38473007

RESUMO

BACKGROUND: The predictive value of thrombus perviousness in acute ischemic stroke (AIS), as measured by computed tomography (CT), has been intensively studied with conflicting results. In this study, we investigate the predictive potential of the novel concept of dynamic perviousness using three-dimensional (3D) volumetric evaluation of occlusive thrombi. METHODS: The full thrombus volume in 65 patients with a hyperdense artery sign on non-contrast CT (NCCT), who underwent mechanical thrombectomy (MT), was segmented. Perviousness maps were computed voxel-wise for the entire thrombus volume as thrombus attenuation increase (TAI) between NCCT and CT angiography (CTA) as well as between CTA and late venous phase CT (CTV). Perviousness was analyzed for its association with NIHSS at admission, Thrombolysis In Cerebral Infarction (TICI) score, and number of MT passes. RESULTS: The mean late-uptake TAI of thrombi with NIHSS scores greater than 21 at admission was approximately 100% higher than for lower scored NIHSS (p between 0.05 and 0.005). Concerning revascularization results, thrombi requiring less than four MT passes had ca. 80% higher group mean late-uptake TAI than clots requiring four or more passes (p = 0.03), and thrombi with TICI score III had ca. 95% higher group mean late-uptake TAI than thrombi with TICI II (p = 0.03). Standard perviousness showed no significant correlation with MT results. CONCLUSION: Standard thrombus perviousness of 3D clot volume is not associated with revascularization results in AIS. In contrast, dynamic perviousness assessed with a voxel-wise characterization of 3D thrombi volume may be a better predictor of MT outcomes than standard perviousness.

7.
Diagnostics (Basel) ; 14(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38893723

RESUMO

BACKGROUND: The predictive value of thrombus standard perviousness (SP) in acute ischemic stroke (AIS) for the technical success rates of mechanical thrombectomy (MT) or functional outcomes is not yet conclusive. We investigated the relationship between dynamic perviousness (DP) and revascularization results using time-dependent enhancement curve types determined with computed tomography (CT). METHODS: A retrospective analysis of 137 AIS patients was performed. DP was calculated as the thrombus attenuation increase (TAI) using three time points and categorized into four groups: (1) no enhancement (CNE); (2) late enhancement (CLE); (3) early enhancement with washout (CW); (4) early enhancement without washout (CNW). Associations with the technical success rate and functional outcomes were assessed. RESULTS: Late enhancement (CLE) had approximately two times higher odds for successful MT as compared to clots with other enhancement dynamics. The odds ratios (logistic regression model with CNW as the reference) for the TICI III scores were 4.04 (p = 0.067), 1.82 (p = 0.3), and 1.69 (p = 0.4) for CLE, CW, and CNE, respectively. The NIHSS scores at discharge and mRS scores at three months showed regression coefficients (linear regression model with CNW as reference) of -3.05 (p = 0.10), -1.17 (p = 0.51), and -1.24 (p = 0.47); and -1.30 (p = 0.097), -0.85 (p = 0.25), and -0.15 (p = 0.83) for CLE, CW, and CNE, respectively. CONCLUSIONS: Thrombi with late enhancement patterns showed a higher revascularization rate and better outcomes as compared to clots with early uptake or no washout.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38719606

RESUMO

BACKGROUND AND PURPOSE: The impact of therapeutic embolization as a stand-alone treatment of head and neck paragangliomas considered surgically high-risk remains insufficiently understood. The aim of this study was to investigate the procedural risks and long-term volumetric development in head and neck paragangliomas with high surgical risk following therapeutic endovascular embolization as stand-alone treatment. MATERIALS AND METHODS: A retrospective database review of patients who underwent endovascular embolization as primary treatment for head and neck paragangliomas lacking appropriate curative treatment options at our institution (from January 2000 to February 2023) was conducted. Tumor volumetric analyses were performed before embolization and during follow-up. To assess the changes in tumor volume over time, the measurements were performed after embolization, first at 6 months and then on a yearly basis up to 6 years (mean follow-up time was: 33.7 ± 24.4 months). Subgroup analyses were conducted for vagal and jugular/jugulotympanic paragangliomas. RESULTS: A total of 32 head and neck paragangliomas in 28 patients (mean age, 56.1 years ± 16.5 [standard deviation]; 18 female) with therapeutic embolization as stand-alone treatment were evaluated, of which 11 were vagal paragangliomas, 15 jugular/jugulotympanic paragangliomas and 6 carotid body tumors. After a mean follow-up duration of 33.7 ± 24.4 months tumor control was achieved in 75%, with significant median tumor volume reduction at 6 months (p = .02, n = 21). Vagal paragangliomas responded the most to embolization with a significantly decreased median volume from 22.32 cm3; to 19.09 cm3 (p = .008, n = 8). Transient complications occurred in 3.4%. CONCLUSIONS: Therapeutic embolization as a stand-alone treatment offers a low-risk control of tumor growth in surgically high-risk lesions, with a significant reduction in tumor volume after treatment. Among the different subtypes, vagal paragangliomas exhibited the strongest and longest regression of the tumor volume.ABBREVIATIONS: HNPGL = head and neck paragangliomas; IQR = interquartile range; JTP = jugular/jugulotympanic paragangliomas; PVA = polyvinyl alcohol; VP = vagal paragangliomas.

9.
Diagnostics (Basel) ; 14(13)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39001277

RESUMO

Dynamic perviousness is a novel imaging biomarker, with clot density measurements at multiple timepoints to allow longer contrast to thrombus interaction. We investigated the correlations between dynamic perviousness and clot composition in the setting of acute ischemic stroke. Thirty-nine patients with large vessel occlusion (LVO) undergoing mechanical thrombectomy (MT) were analyzed. Patients received a three-phase CT imaging pre-thrombectomy and histopathological analysis of retrieved clots. Clot densities for every phase and change in densities between phases were calculated, leading to four patterns of dynamic perviousness: no contrast uptake, early contrast uptake with and without washout and late uptake. Clots were categorized into three groups based on dominant histologic composition: red blood cell (RBC)-rich, fibrin/platelet-rich and mixed. Clot composition was correlated with dynamic perviousness using the Kruskal-Wallis test and Pearson's correlation analysis. The dynamic perviousness categories showed a significant difference between fibrin-rich clots when compared to RBC-rich plus mixed groups. The uptake without washout category had significantly fewer fibrin clots compared to the uptake with washout (p = 0.036), and nearly significantly fewer fibrin clots when compared to the no uptake category (p = 0.057). Contrast uptake with different patterns of contrast washout showed significant differences of the likelihood for fibrin-rich clots.

10.
Eur Stroke J ; : 23969873241251718, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742386

RESUMO

INTRODUCTION: A significant number of patients who present with mild symptoms following large-vessel occlusion acute ischemic stroke (LVO-AIS) are currently considered ineligible for EVT. However, they frequently experience neurological deterioration during hospitalization. This study aimed to investigate the association between neurological deterioration and hemodynamic impairment by assessing steal phenomenon derived from blood oxygenation-level dependent cerebrovascular reactivity (BOLD-CVR) in this specific patient cohort. PATIENTS AND METHODS: From the database of our single-center BOLD-CVR observational cohort study (June 2015-October 2023) we retrospectively identified acute ischemic stroke patients with admission NIHSS < 6, a newly detected large vessel occlusion of the anterior circulation and ineligible for EVT. Neurological deterioration during hospitalization as well as outcome at hospital discharge were rated with NIHSS score. We analyzed the association between these two outcomes and BOLD-CVR-derived steal phenomenon volume through regression analysis. Additionally, we investigated the discriminatory accuracy of steal phenomenon volume for predicting neurological deterioration. RESULTS: Forty patients were included in the final analysis. Neurological deterioration occurred in 35% of patients. In the regression analysis, a strong association between steal phenomenon volume and neurological deterioration (OR 4.80, 95% CI 1.32-31.04, p = 0.04) as well as poorer NIHSS score at hospital discharge (OR 3.73, 95% CI 1.52-10.78, p = 0.007) was found. The discriminatory accuracy of steal phenomenon for neurological deterioration prediction had an AUC of 0.791 (95% CI 0.653-0.930). DISCUSSION: Based on our results we may distinguish two groups of patients with minor stroke currently ineligible for EVT, however, showing hemodynamic impairment and exhibiting neurological deterioration during hospitalization: (1) patients exhibiting steal phenomenon on BOLD-CVR imaging as well as hemodynamic impairment on resting perfusion imaging; (2) patients exhibiting steal phenomenon on BOLD-CVR imaging, however, no relevant hemodynamic impairment on resting perfusion imaging. CONCLUSION: The presence of BOLD-CVR derived steal phenomenon may aid to further study hemodynamic impairment in patients with minor LVO-AIS not eligible for EVT.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38997121

RESUMO

BACKGROUND AND PURPOSE: Assessing treatment success of intracranial aneurysms treated with Woven EndoBridge (WEB) devices using MRI is important in follow-up imaging. Depicting both the device configuration as well as reperfusion is challenging due to susceptibility artefacts. We evaluated the usefulness of contrast-enhanced 3D-Ultrashort Echo-Time (UTE) sequence in this setting. MATERIALS AND METHODS: In this prospective study, 12 patients (9 female) with 15 treated aneurysms were included. These 12 patients underwent 18 MRI examinations. Follow-up UTE-MRI controls were performed on the same 3-Tesla scanner. We compared the visualization of device configuration, artifact-related virtual stenosis of the parent vessel and WEB occlusion scale in 3D isotropic UTE-MRI post-contrast with standard time-of-flight (TOF) MR-angiography with (CE) and without intravenous contrast as well as DSA. Two interventional neuroradiologists rated the images separately and in consensus. RESULTS: Visualization of the WEB device position and configuration was rated superior or highly superior using the UTE sequence in 17/18 MRIs compared to TOF-MRA. Artifact-related virtual stenosis of the parent vessel was significantly lower in UTE-MRI compared to TOF and CE-TOF. Reperfusion was visible in 8/18 controls in DSA. TOF was able to grade reperfusion correctly in 16 cases, CE-TOF in 16 cases and UTE in 17 cases. CONCLUSIONS: Contrast-enhanced UTE is a novel MRI sequence that shows benefit compared to standard sequences in non-invasive and radiation-free follow-up imaging of intracranial aneurysms treated using the WEB-device. ABBREVIATIONS: ACoA = anterior communicating artery, BA = basilar artery, CEA = contrast enhanced angiography, ICA = internal carotid artery, MCA = middle cerebral artery, PCom = posterior communicating artery TOF-CE = contrast enhanced time-of-flight angiography, UTE = ultra-short echo time, WEB = woven endobridge.

12.
Interv Neuroradiol ; : 15910199231177745, 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37221854

RESUMO

BACKGROUND: Hemorrhagic and thromboembolic complications (TECs) are the main concerns in the endovascular treatment of intracranial aneurysms using flow diverter devices (FDs). The clinical demand for single antiplatelet therapy (SAPT) is increasing especially with the development of devices with lower thrombogenicity profile. However, the safety of SAPT is not well established. OBJECTIVE: To analyze the safety and efficacy of SAPT in terms of ischemic and hemorrhagic complications in patients undergoing FDs treatment for cerebral aneurysms. METHODS: A systematic literature search and meta-analysis were conducted in PubMed, Ovid MEDLINE, Ovid Embase, and Web of Science from January 2010 until October 2022. Twelve articles which reported SAPT and data on hemorrhagic, TECs, and mortality following FDs treatment were included. RESULTS: Overall, the 12 studies involved 237 patients with 295 aneurysms. Five investigated the safety and efficacy of SAPT in 202 unruptured aneurysms. Six studies focused on 57 ruptured aneurysms. One study included both ruptured and unruptured aneurysms. Among the 237 patients, prasugrel was most often used as SAPT in 168 cases (70.9%), followed by aspirin in 42 (17.7%) patients, and by ticagrelor in 27 (11.4%). Overall, the hemorrhagic complication rate was 0.1% (95% CI 0% to 1.8%). The TEC rate was 7.6% (95% CI 1.7% to 16.1%). In the subgroup analysis, the TEC rates of prasugrel monotherapy of 2.4% (95% CI 0% to 9.3%) and ticagrelor monotherapy of 4.2% (95% CI 0.1% to 21.1%) were lower than of aspirin monotherapy 20.2% (95% CI 5.9% to 38.6%). The overall mortality rate was 1.3% (95% CI 0% to 6.1%). CONCLUSION: According to the available data, SAPT regimen in patients undergoing FDs treatment for cerebral aneurysms has an acceptable safety profile, especially with the use of ADP-receptor antagonists.

13.
Clin Neuroradiol ; 33(4): 1115-1122, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37401949

RESUMO

PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (p = 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89 mm) and 3D-DSA (4.2 mm, p = 0.08) but not between UHR-TOF (4.12 mm) and 3D-DSA (p = 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil p = 0.19, FD p = 0.45) nor between UHR-TOF and 3D-DSA (coil: p = 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (p = 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/patologia , Seguimentos , Projetos Piloto , Angiografia por Ressonância Magnética/métodos , Angiografia Digital/métodos , Sensibilidade e Especificidade
14.
J Neurointerv Surg ; 15(10): 953-957, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36328478

RESUMO

BACKGROUND: Flow diversion treatment of ruptured cerebral aneurysms remains challenging due to the need for double-antiplatelet therapy. We report our experience with flow-diverter stent (FDS) reconstruction with single-antiplatelet therapy of ruptured cerebral blood blister and dissecting aneurysms. METHODS: In this case series we performed a retrospective analysis of all patients with ruptured cerebral aneurysms who were treated with a phosphoryl-bonded FDS between 2019 and 2022 in a single center. Periprocedurally, all patients received weight-adapted eptifibatide IV and heparin IV. After 6-24 hours, eptifibatide was switched to oral prasugrel as monotherapy. We analyzed the rate of bleeding complications, thromboembolic events, occlusion rate and clinical outcome. RESULTS: Nine patients with subarachnoid hemorrhage were treated, eight within 24 hours of symptom onset. Seven patients were treated with one FDS and two patients received two FDS in a telescopic fashion. Two aneurysms were additionally coil embolized. Fatal re-rupture occurred in one case; eight patients survived and had no adverse events associated with the FDS. Six patients showed complete occlusion of the aneurysm after 3 months (n=2) and 1 year (n=4), respectively. Two patients showed subtotal occlusion of the aneurysm at the last follow-up after 3 months and 6 months, respectively. Favorable clinical outcome was achieved in five patients. CONCLUSIONS: Peri-interventional single-antiplatelet therapy with eptifibatide followed by prasugrel was sufficient to prevent thromboembolic events and reduce re-bleeding using an anti-thrombogenic FDS. FDS with single-antiplatelet therapy might be a viable option for ruptured blood blister and dissecting cerebral aneurysms.


Assuntos
Aneurisma Roto , Dissecção Aórtica , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/tratamento farmacológico , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Inibidores da Agregação Plaquetária/uso terapêutico , Eptifibatida , Cloridrato de Prasugrel , Vesícula/cirurgia , Resultado do Tratamento , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Stents , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/tratamento farmacológico , Hemorragia Subaracnóidea/cirurgia
15.
Rofo ; 193(5): 544-550, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33212538

RESUMO

PURPOSE: A direct aspiration first pass technique (ADAPT) is an effective thrombectomy option in patients with acute ischemic stroke. Balloon guide catheters (BGC) seem to improve the efficacy of stent retrievers and ADAPT. The last generation 6F aspiration catheters require 9F BGCs, which are rigid devices that are challenging to position in a tortuous anatomy. In this experimental study the efficacy of 6F ADAPT alone and 5F ADAPT combined with 8F BGC was evaluated. MATERIALS AND METHODS: Either a fibrin rich (white) clot or an RBC rich (red) clot was placed in the M1 segment of a transparent silicon phantom. Physiological hemodynamic conditions were maintained. The clots were retrieved by 6F aspiration catheter via 8F long sheath or 5F aspiration catheter via a flexible 8F BGC. Thrombectomy was performed under direct visual control. The primary endpoints were the number of passes and the number of distal emboli. RESULTS: Ten experiments were made with each clot model and thrombectomy technique (n = 40). Full recanalization could be achieved in every experiment. First pass mTICI 3 could be achieved by 6F ADAPT in 80 % of red clots and 90 % of white clots. Distal emboli were caused in 10 % and 20 %, respectively. When using 5F ADAPT combined with BGC, a first pass mTICI 3 rate of 90 % in red clots and 100 % in white clots could be achieved. A 10 % rate of distal emboli occurred in both groups. In almost all experiments (both techniques), the thrombi clogged the aspiration catheter. No statistically significant differences could be found between the techniques and clot models. CONCLUSION: 6F ADAPT without BGC was as effective as 5F ADAPT combined with a flexible 8F BGC, with both techniques showing high first-pass recanalization rates and low distal emboli rates. Especially in the case of a tortuous anatomy, these setups should be considered as alternatives to a rigid 9F BGC. The thrombus compositions seemed to be irrelevant in this setting. KEY POINTS: · 6F ADAPT with no BGC and 5F ADAPT with BGC were very effective and performed equally.. · Both techniques should be considered in tortuous anatomy.. · In this setting the clot composition showed no effect on the recanalization rate.. CITATION FORMAT: · Madjidyar J, Nerkada L, Larsen N et al. Choosing an Effective and Safe Direct Aspiration Setup for Tortuous Anatomy in Acute Ischemic Stroke: In vitro Study in a Physiological Flow Model. Fortschr Röntgenstr 2021; 193: 544 - 550.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Trombectomia , Isquemia Encefálica/diagnóstico por imagem , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/cirurgia , Modelos Biológicos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/métodos , Trombectomia/normas , Resultado do Tratamento
16.
Rofo ; 192(3): 257-263, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31514211

RESUMO

PURPOSE: A first-pass, direct aspiration technique and stent retrieval with a balloon guide catheter represent advanced thrombectomy techniques that are increasingly being used in the clinical routine. The purpose of this experimental study was to evaluate whether the techniques' effectiveness depended on the clot composition and to visualize the interaction between the devices and the clot. MATERIALS AND METHODS: Erythrocyte-rich (red) and fibrin-rich (white) clots were placed into the M1-segment of the middle cerebral artery in a transparent vascular phantom with physiological architecture. Physiological hemodynamic conditions were maintained with a programmable pump. On the one hand direct aspiration with a 5F aspiration catheter (ADAPT) and on the other hand stent retrieval with a balloon guide catheter (flow arrest/reversal) was performed. The experiments were made under direct visual control to observe the interaction between the devices and the clot. The primary end points were the number of passes/maneuvers and the occurrence of distal emboli and emboli in a new territory (anterior cerebral artery), until full recanalization was achieved. The experiment was filmed with a full high-definition camera identifying emboli. RESULTS: Six experiments were conducted for each technique and clot model. Red clots were retrieved by ADAPT with fewer passes and distal emboli, and could usually be aspirated directly at the occlusion site. White clots clogged the tip of the 5F aspiration catheter in every experiment. The catheter had to be pulled back into the long sheath in the cervical internal carotid artery, producing distal emboli. White clots were retrieved by the stent retriever and balloon guide catheter with fewer distal emboli. There was no difference in the number of passes. The stent-thrombus interaction was superficial in both clot models. Successful retrieval was granted by the flow arrest and proximal aspiration/flow reversal. One embolus in a new territory developed when using each technique in white clots. CONCLUSION: This experimental study showed that the efficacy of advanced thrombectomy techniques might depend on clot composition. Identifying the right technique for the right clot might improve the results of thrombectomy. In a clinical setting the thrombus morphology in non-enhanced CT could be used as a marker for patient selection. KEY POINTS: · The efficacy of thrombectomy seems to depend on thrombus composition.. · ADAPT might be more effective for rbc-rich clots.. · Thrombectomy with BGC might be more effective for fibrin-rich clots.. CITATION FORMAT: · Madjidyar J, Pineda Vidal L, Larsen N et al. Influence of Thrombus Composition on Thrombectomy: ADAPT vs. Balloon Guide Catheter and Stent Retriever in a Flow Model. Fortschr Röntgenstr 2020; 192: 257 - 263.


Assuntos
Embolectomia com Balão/instrumentação , Infarto da Artéria Cerebral Média/terapia , Stents , Sucção/instrumentação , Trombectomia/instrumentação , Desenho de Equipamento , Eritrócitos , Humanos , Modelos Cardiovasculares , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Clin Neuroradiol ; 30(4): 811-815, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31754758

RESUMO

PURPOSE: Wall enhancement of intracranial aneurysms in vessel wall magnetic resonance imaging (MRI) has been linked to aneurysm progression. The clinical significance of aneurysm enhancement after embolization has not yet been investigated. The goal of this study was to identify factors associated with aneurysm wall enhancement and reperfusion after embolization. METHODS: Patients who underwent treatment of intracranial aneurysms with coils or the Woven Endobridge (WEB) and follow-up MR vessel wall imaging were included. Enhancement of the treated aneurysms was separately recorded for the following locations: a) wall at the neck, b) wall at the dome, and c) in the aneurysmal cavity. Reperfusion was determined on follow-up digital subtraction angiography (DSA) and MR time of flight (TOF) angiography. RESULTS: In this study 48 patients with 53 aneurysms were included. Wall enhancement at the neck and the dome of the aneurysm was significantly associated with time between embolization and follow-up MRI under 6 months. Enhancement inside the aneurysmal cavity was significantly associated with a follow-up time longer than 6 months, and with stable aneurysms without reperfusion. CONCLUSION: Wall enhancement is a regular feature in intracranial aneurysms after embolization and decreases over time. Enhancement inside the aneurysmal cavity is associated with a stable state and could possibly serve as an imaging marker of completed aneurysm healing.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Angiografia Digital , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Reperfusão , Resultado do Tratamento
19.
Rofo ; 190(11): 1053-1058, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29913521

RESUMO

PURPOSE: Various stent retrievers differing in stent design and mechanical properties are currently available for the treatment of ischemic stroke. We conducted this in vitro study to compare the efficacy, embolism rate, and safety of commercially available stent retrievers and prototypes. MATERIALS AND METHODS: Whole blood thrombi were produced in a Chandler loop. The thrombi were inserted into the curved M1 segment of a silicone model of the anterior cerebral circulation. Thrombectomy maneuvers were performed with six commercially available stent retrievers and 2 prototypes with different strut thickness. Wall-stent apposition, first pass recanalization rate, retraction force, and embolism rate were compared. RESULTS: Devices with complete wall-stent apposition had the highest first pass recanalization rate and lowest embolism rate, but showed the highest retraction force. The prototype with thinner struts had a comparable recanalization and embolism rate, while a lower retraction force had to be applied compared to the prototype with thicker struts. CONCLUSION: Complete wall-stent apposition facilitates a higher recanalization rate and lower embolism rate but also correlates to a higher necessary retraction force and thus possibly higher risk of endothelium damage. Stent modifications leading to a reduced retraction force do not compromise efficacy and embolism rate. KEY POINTS: · Complete wall-stent apposition facilitates an effective thrombectomy. · Complete wall-stent apposition leads to higher retraction force and possibly greater endothelium damage. · Modifications of strut thickness do not compromise recanalization and embolism rate. · Thinner struts correlate with a lower retraction force. CITATION FORMAT: · Larsen N, Oberbeck K, Lima de Miranda R et al. Comparison of Efficacy, Embolism Rate and Safety of Thrombectomy with Stent Retrievers in an Anterior Circulation Stroke Model. Fortschr Röntgenstr 2018; 190: 1053 - 1058.


Assuntos
Infarto Encefálico/cirurgia , Remoção de Dispositivo/instrumentação , Procedimentos Endovasculares/instrumentação , Modelos Cardiovasculares , Stents , Acidente Vascular Cerebral/cirurgia , Trombectomia/instrumentação , Ligas , Desenho de Equipamento , Humanos , Técnicas In Vitro , Embolia Intracraniana/etiologia , Complicações Pós-Operatórias/etiologia , Estudo de Prova de Conceito
20.
Rofo ; 191(8): 752-753, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30900230
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA