Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Sep Sci ; 46(21): e2300424, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37650313

RESUMO

Clarithromycin is a very important macrolide antibiotic used to treat bacterial infections in human and veterinary medicine. This study reports the development and validation of cost-effective, simple, precise, accurate, and robust high-performance liquid chromatography (HPLC) for the determination of clarithromycin (CLA) in tablets. Reversed-phase chromatography was conducted using a standard column at 55°C with ultraviolet detection at 215 nm. A mobile phase consisting of acetonitrile -2-methyl-2-propanol -potassium phosphate buffer was used at a flow rate of 1.0 mL/min. The proposed method displayed good linearity, precision, accuracy, robustness, and specificity. The present HPLC was compared with capillary electrophoresis and bioassay methods and the results indicated that there was no significant difference between these methods. Moreover, the obtained results demonstrated the validity of the isocratic HPLC, which allows reliable quantitation of CLA in pharmaceutical samples. Thus, it can be used as a substitute alternative methodology for the routine quality control of this medicine, in situations where other methods are less accessible in the laboratory.


Assuntos
Antibacterianos , Claritromicina , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Comprimidos , Reprodutibilidade dos Testes
2.
Talanta ; 211: 120703, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32070606

RESUMO

Microbiological and electrochemical assays, applying the cylinder-plate and differential pulse voltammetry as techniques, are reported for the quantitative determination of roxithromycin in serum and solid pharmaceutical form. The microbiological assay is based upon the inhibitory effect of this drug on the strain Bacillus subtilis ATCC 9372 used as the test microorganism. Linearity of the calibration curve was observed over the concentration range of 8.37-83.70 µg mL-1, with relative standard deviation values less than 5.0%. The electrochemical behavior of roxithromycin was studied at a graphite screen-printed electrode modified with graphene by using cyclic voltammetry and differential pulse voltammetry. The current value of the oxidative peak obtained for roxithromycin at 0.65 V vs. Ag/AgCl in 0.03 mol L-1 phosphate buffer solution (pH 7.0) with a scan rate of 0.1 V-1 is a linear function of the concentration in a range of 4.19-83.70 µg mL-1 (5-100 µmol L-1). A comparative study was carried out and both methods were applied for the determination of roxithromycin in solid dosage forms and spiked serum. The bioassay results of human serum samples were in accordance with the electrochemical ones (R2 = 0.988, P < 0.001), and the Bland-Altman method also showed good agreement between the values obtained by both procedures. Moreover, the statistical comparison indicated that there was no significant difference between the proposed techniques regarding both accuracy and precision.


Assuntos
Antibacterianos/análise , Roxitromicina/análise , Antibacterianos/sangue , Antibacterianos/farmacologia , Bacillus subtilis/efeitos dos fármacos , Bacillus subtilis/crescimento & desenvolvimento , Bioensaio , Técnicas Eletroquímicas , Humanos , Roxitromicina/sangue , Roxitromicina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA