1.
Circulation ; 119(23): 2986-94, 2009 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-19487593

RESUMO

BACKGROUND: Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. METHODS AND RESULTS: One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 microg/mm2) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of > or =70% and < or =22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38+/-0.61 mm in the drug-eluting stent group versus 0.17+/-0.42 mm (P=0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; P=0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively (P=0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group (P=0.15). CONCLUSIONS: Treatment of coronary in-stent restenosis with the paclitaxel-coated balloon was at least as efficacious and as well tolerated as the paclitaxel-eluting stent. For the treatment of in-stent restenosis, inhibition of re-restenosis does not require a second stent implantation.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Moduladores de Tubulina/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico
2.
EuroIntervention ; 11(8): 926-34, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25169589

RESUMO

AIMS: Treatment of bare metal in-stent restenosis with the paclitaxel-coated balloon catheter based on the PACCOCATH® technology has yielded superior six-month angiographic and one-year clinical results compared to a paclitaxel-eluting stent. The three-year clinical follow-up is presented. METHODS AND RESULTS: One hundred and thirty-one patients with coronary bare metal in-stent restenosis (>70%, length: <22 mm, vessel diameter: 2.5-3.5 mm) were randomly treated with the paclitaxel-coated balloon (DCB) (3 µg/mm²) or a paclitaxel-eluting stent (DES). Clinical follow-up information was requested from the patients and from their physicians. Quantitative angiographic and demographic baseline data were statistically not different between the groups. Per intention-to-treat analysis at 12 months, the lesion-related rates of major adverse cardiac events were 7.6% and 16.9% (p=0.11) while at 36 months the respective numbers were 9.1% and 18.5% (p=0.14). These differences were primarily due to reduced target lesion revascularisation (TLR) in DCB 4/66 (6.2%) compared to DES patients 10/65 (15.4%) (p=0.10). From 12 to 36 months, 1/65 (1.5%) DCB patients experienced a myocardial infarction while neither TLR nor death occurred in any study patient in either group during that period. CONCLUSIONS: The six-month superiority of the paclitaxel-coated balloon compared to the paclitaxel-eluting stent in the treatment of bare metal coronary in-stent restenosis persisted throughout the three-year clinical follow-up period indicating stability of the lesions treated. (ClinicalTrials.gov Identifier: NCT00393315).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Stents , Dispositivos de Acesso Vascular , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Intervalo Livre de Doença , Feminino , Alemanha , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Desenho de Prótese , Retratamento , Fatores de Tempo , Resultado do Tratamento
3.
J Invasive Cardiol ; 15(10): 557-60, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14519886

RESUMO

UNLABELLED: Percutaneous interventions of degenerated saphenous vein grafts (SVG) are associated with high rates of distal embolic events and in-stent restenosis. A novel ePTFE-covered stent graft has been developed to improve outcomes for these difficult lesions. The stent graft has been treated with a 15-amino acid, cell adhesion peptide (P-15) to promote endothelialization on the inner surface post-implantation. Patients with de novo lesions in SVGs were treated with a peptide-coated ePTFE stent graft. Follow-up data was collected at 30 days, 3 and 6 months. An angiographic core lab analyzed an angiographic follow-up at 6 months. RESULTS: Procedural success was achieved in all cases. No device-related major adverse cardiac events occurred in-hospital, at 30 days, or at 3 months, despite the lack of distal protection. Six-month restenosis rates were 21%, and were comparable to similar devices. CONCLUSIONS: The peptide-treated stent graft appears to be a safe and effective treatment for SVG lesions, and has the potential to reduce complications without the use of adjunct distal protection in this patient population.


Assuntos
Materiais Revestidos Biocompatíveis/uso terapêutico , Colágeno/uso terapêutico , Ponte de Artéria Coronária/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Fragmentos de Peptídeos/uso terapêutico , Politetrafluoretileno/uso terapêutico , Veia Safena/patologia , Procedimentos Cirúrgicos Vasculares/instrumentação , Idoso , Prótese Vascular , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veia Safena/transplante , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA