Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 7, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166794

RESUMO

OBJECTIVES: Modified cortical bone trajectory (MCBT) technique was proposed by our team in previous studies, but its biomechanical properties at adjacent segments have not been discussed yet. Therefore, the purpose of this study is to investigate the biomechanical properties of modified cortical bone trajectory (MCBT) technique on adjacent segment degeneration (ASD) in transforaminal intradiscal lumbar disc fusion (TLIF) compare to traditional bone trajectory (TT) technique and cortical bone trajectory (CBT) technique. METHODS: The four human cadaveric lumbar specimens were provided by the anatomy teaching and research department of Xinjiang Medical University and four intact finite element models of the L1-S1 segment were generated. For each of these, three transforaminal lumbar interbody fusion procedures with three different fixation techniques were reconstructed at the L4-L5 segment, as follows: TT-TT (TT at both L4 and L5 segments), CBT-CBT (CBT at both L4 and L5 segments), MCBT-MCBT (MCBT at both L4 and L5 segments). The range of motion and von Mises stress of the intervertebral disc of the L3-L4 and L5-S1 segments were recorded with a 400N compressive load and 7.5 Nm moments in flexion, extension, left-right bending, and left-right rotation. RESULTS: The peak ROM of the L3-L4 segment in the MCBT-MCBT group was reduced by 10.5%, 6.1%, 12.2%, 4.1%, and 1.5% in flexion, extension, left-right bending, and left rotation compared to the TT-TT group and reduced by 1.8%, 5.5%, 10.0%, 12.8%, and 8.8% in flexion, left-right bending, and left-right rotation compared to the CBT-CBT group, respectively. The MCBT-MCBT group has the lowest peak ROM of the L3-L4 segment in flexion, left bending, and right rotation, the lowest peak ROM of the L5-S1 segment in extension and right rotation, and the lowest peak von Mises stress of the intervertebral disc at the L5-S1 segment in right rotation compared to the TT-TT and CBT-CBT group. In addition, the peak von Mises stress at the L3-L4 segment was lowest and more dispersed in all motions, the MCBT-MCBT group exhibited lower peak ROM of the L5-S1 segment in flexion, extension, and right rotation, and showed lower peak von Mises stress of the disc at the L5-S1 segment in flexion, extension, and right rotation compared with the TT-TT group. CONCLUSION: The modified cortical bone trajectory technique may have a beneficial effect on reducing the incidence of ASD in the L4-L5 TLIF model compared to the traditional bone trajectory technique and cortical bone trajectory technique.


Assuntos
Vértebras Lombares , Fusão Vertebral , Humanos , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Osso Cortical/cirurgia , Amplitude de Movimento Articular
2.
BMC Musculoskelet Disord ; 24(1): 288, 2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37055739

RESUMO

BACKGROUND: Investigate the biomechanical properties of the hybrid fixation technique with bilateral pedicle screw (BPS) and bilateral modified cortical bone trajectory screw (BMCS) in L4-L5 transforaminal lumbar interbody fusion (TLIF). METHODS:  Three finite element (FE) models of the L1-S1 lumbar spine were established according to the three human cadaveric lumbar specimens. BPS-BMCS (BPS at L4 and BMCS at L5), BMCS-BPS (BMCS at L4 and BPS at L5), BPS-BPS (BPS at L4 and L5), and BMCS-BMCS (BMCS at L4 and L5) were implanted into the L4-L5 segment of each FE model. The range of motion (ROM) of the L4-L5 segment, von Mises stress of the fixation, intervertebral cage, and rod were compared under a 400-N compressive load with 7.5 Nm moments in flexion, extension, bending, and rotation. RESULTS:  BPS-BMCS technique has the lowest ROM in extension and rotation, and BMCS-BMCS technique has the lowest ROM in flexion and lateral bending. The BMCS-BMCS technique showed maximal cage stress in flexion and lateral bending, and the BPS-BPS technique in extension and rotation. Compared to the BPS-BPS and BMCS-BMCS technique, BPS-BMCS technique presented a lower risk of screw breakage and BMCS-BPS technique presented a lower risk of rod breakage. CONCLUSION:  The results of this study support that the use of the BPS-BMCS and BMCS-BPS techniques in TLIF surgery for offering the superior stability and a lower risk of cage subsidence and instrument-related complication.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Análise de Elementos Finitos , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia
3.
Heliyon ; 10(5): e26294, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38434416

RESUMO

Background: The academia has increasingly acknowledged the superior biomechanical performance of the hybrid fixation technique in recent years. However, there is a lack of research on the hybrid fixation technique using BCS (Bilateral Cortical Screws) and BMCS (Bilateral Modified Cortical Screws). This study aims to investigate the biomechanical performance of the BCS and BMCS hybrid fixation technique in transforaminal lumbar interbody fusion (TLIF) at the L4-L5 segment in a complete lumbar-sacral finite element model. Methods: Three cadaver specimens are used to construct three lumbar-sacral finite element models. The biomechanical properties of various fixation technologies (BCS-BCS, BMCS-BMCS, BMCS-BCS, and BCS-BMCS) are evaluated at the L4-5 segment with a TLIF procedure conducted, including the range of motion (ROM) of the L4-5 segment, as well as the stress experienced by the cage, screws, and rods. The testing is conducted under specific loading conditions, including a compressive load of 400 N and a torque of 7.5Nm, subjecting the model to simulate flexion, extension, lateral bending, and rotation. Results: No significant variations are seen in the ROM at the L4-5 segment when comparing the four fixation procedures during flexion and extension. However, when it comes to lateral bending and rotation, the ROM is ordered in descending order as BCS-BCS, BCS-BMCS, BMCS-BMCS, and BMCS-BCS. The maximum stress experienced by the cage is observed to be highest within the BMCS-BCS technique during movements including flexion, extension, and lateral bending. Conversely, the BMCS-BMCS technique exhibits the highest cage stress levels during rotational movements. The stress applies to the screws and rods order the sequence of BCS-BCS, BCS-BMCS, BMCS-BCS, and BMCS-BMCS throughout all four working conditions. Conclusion: The BMCS-BCS technique shows better biomechanical performance with less ROM and lower stress on the internal fixation system compared to other fixation techniques. BMCS-BMCS technology has similar mechanical performance to BMCS-BCS but has more contact area between screws and cortical bone, making it better for patients with severe osteoporosis.

4.
Global Spine J ; : 21925682241230465, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38314556

RESUMO

STUDY DESIGN: Review. OBJECTIVE: Unilateral Biportal Endoscopy (UBE) is a minimally invasive surgery that is gaining recognition and being employed in clinical practice. Nevertheless, the precise method for determining UBE portals' location varies depending on the originator's preferences or the anatomical structure's proximity to the portal positions. Consequently, the relationship among UBE portals' locations is messy. This study aims to elaborate on the specific portal localization and explore the positional association and commonality among different UBE approaches' portals. METHODS: The following keywords are used to search in the PubMed, Ovid, Web of Science, ScienceDirect, SpringerLink, Scopus, CNKI, and Wanfang database: "Biportal endoscopic spinal surgery", "Two portal endoscopic spinal surgery", "Percutaneous biportal endoscopic decompression", "Unilateral biportal endoscopy", "Irrigation endoscopic discectomy", "UBE" and "BESS". RESULTS: After screening, 29 pieces of literature are included. The study summarizes different UBE approach portal localizations, categorized by fusion or non-fusion surgery and pathological classification. The study presents an inaugural method for categorizing the lumber into four surgical intervals based on bone landmarks and assigns different UBE approaches to the appropriate intervals based on their characteristics, making the selection of UBE surgical approaches' portal locations more flexible. Additionally, the study provides an overview of the indications, complications, and distinct benefits associated with each interval, further refining the novel UBE portal interval localization method. CONCLUSION: The study clarifies the interrelationship and commonality between the portals of different UBE approaches and proposes a new UBE portal interval localization method to enhance surgeons' understanding and proficiency in UBE procedures.

5.
J Orthop Surg Res ; 18(1): 549, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37525283

RESUMO

OBJECTIVE: To compare the biomechanical performance of the hybrid lumbar fixation technique with the traditional and cortical bone trajectory techniques using the finite element method. METHODS: Four adult wet lumbar spine specimens were provided by the Department of Anatomy and Research of Xinjiang Medical University, and four L1-S1 lumbar spine with transforaminal lumbar interbody fusion (TLIF) models at L4-L5 segment and four different fixation techniques were established: bilateral traditional trajectory screw fixation (TT-TT), bilateral cortical bone trajectory screw fixation (CBT-CBT), hybrid CBT-TT (CBT screws at L4 and TT screws at L5) and TT-CBT (TT screws at L4 and CBT screws at L5). The range of motion (ROM) of the L4-L5 segment, von Mises stress of cage, internal fixation, and rod were compared in flexion, extension, left and right bending, and left and right rotation. RESULTS: Compared with the TT-TT group, the TT-CBT group exhibited lower ROM of L4-L5 segment, especially in left-sided bending; the CBT-TT group had the lowest ROM of L4-L5 segment in flexion and extension among the four fixation methods. Compared with the CBT-CBT group, the peak cage stress in the TT-CBT group was reduced by 9.9%, 18.1%, 21.5%, 23.3%, and 26.1% in flexion, left bending, right bending, left rotation, and right rotation conditions, respectively, but not statistically significant (P > 0.05). The peak stress of the internal fixation system in the TT-CBT group was significantly lower than the other three fixation methods in all five conditions except for extension, with a statistically significant difference between the CBT-TT and TT-CBT groups in the left rotation condition (P = 0.017). In addition, compared with the CBT-CBT group, the peak stress of the rod in the CBT-TT group decreased by 34.8%, 32.1%, 28.2%, 29.3%, and 43.0% under the six working conditions of flexion, extension, left bending, left rotation, and right rotation, respectively, but not statistically significant (P > 0.05). CONCLUSIONS: Compared with the TT-TT and CBT-CBT fixation methods in TLIF, the hybrid lumbar fixation CBT-TT and TT-CBT techniques increase the biomechanical stability of the internal fixation structure of the lumbar fusion segment to a certain extent and provide a corresponding theoretical basis for further development in the clinic.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Adulto , Humanos , Análise de Elementos Finitos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Amplitude de Movimento Articular , Fixação Interna de Fraturas , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Fenômenos Biomecânicos
6.
J Orthop Surg Res ; 18(1): 382, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37226223

RESUMO

BACKGROUND: To obtain the complication rate, fusion rate, and revision rate of the lumbar cortical bone trajectory technique and pedicle screw fixation technique in lumbar interbody fusion surgery by single-arm meta-analysis and lay a basis for orthopedic surgeons to select the fixation techniques and perioperative management. METHODS: PubMed, Ovid Medline, Web of Science, CNKI, and Wanfang databases were searched comprehensively. Data extraction, content analysis, and quality assessment of the literature were performed by two independent reviewers according to the Cochrane Collaboration guidelines using R and STATA software for single-arm meta-analysis. RESULTS: The total complication rate of the lumbar cortical bone trajectory technique was 6%, including a hardware complication rate of 2%, ASD (adjacent segment degeneration) rate of 1%, wound infection rate of 1%, dural damage rate of 1%, hematoma rate tending to 0%, fusion rate of 94%, and revision rate of 1%. Lumbar pedicle screw fixation techniques had a total complication rate of 9%, with a hardware complication rate of 2%, ASD rate of 3%, wound infection rate of 2%, dural damage rate of 1%, hematoma rate tending to 0%, fusion rate of 94%, and revision rate of 5%. This study was registered with PROSPERO, CRD42022354550. CONCLUSION: Lumbar cortical bone trajectory was associated with a lower total complication rate, ASD rate, wound infection rate, and revision rate than pedicle screw fixation. The cortical bone trajectory technique reduces the incidence of intraoperative and postoperative complications and can be an alternative in lumbar interbody fusion surgery.


Assuntos
Parafusos Pediculares , Infecção dos Ferimentos , Humanos , Parafusos Pediculares/efeitos adversos , Osso Cortical/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Hematoma
7.
J Orthop Surg Res ; 18(1): 509, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37464385

RESUMO

BACKGROUND: This study aims to explore the measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar spine, and investigate its clinical significance. METHODS: The angle was measured on 120 normal adults' X-ray and 25 dry anatomical specimens. 60 screws were placed by junior residents on 6 wet specimens through the freehand technique. 30 screws were placed on one side with their original experience. After learning the techniques mentioned in the study, 30 screws were placed on the other side. The specimens were examined by X-ray and CT, and the angles of the screw paths and the integrity of the pedicle were evaluated. RESULTS: The angles of 120 subjects and 25 anatomical specimens show a gradually increasing trend. The differences among each segment were statistically significant (P < 0.05), but the difference in the same segment between the X-ray and the anatomical specimens was not statistically significant (P > 0.05). Furthermore, the differences in L1, L2, and L3 between the two genders were not statistically significant (P > 0.05). However, the angles were larger in female group than in male group in L4 and L5, and the differences were statistically significant (P < 0.05). The difference in the deviation rate of screw placement before and after the learning was statistically significant only in the L5 segment (P < 0.05). The difference in overall excellence rate was statistically significant (P < 0.05). CONCLUSIONS: The measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar can improve the accuracy of the lumbar sagittal screw angle.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Adulto , Humanos , Masculino , Feminino , Relevância Clínica , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Parafusos Ósseos , Radiografia
8.
Front Surg ; 9: 911742, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35923441

RESUMO

Background: Hybrid fixation techniques including the both modified cortical bone trajectory (MCBT) and traditional trajectory (TT) at the L4 and L5 lumbar segment are firstly proposed by our team. Therefore, the purpose of this study is to evaluate and provide specific biomechanical data of the hybrid fixation techniques including the MCBT and TT. Methods: Four human cadaveric specimens were from the anatomy laboratory of Xinjiang Medical University. Four finite-element (FE) models of the L4-L5 lumbar spine were generated. For each of them, four implanted models with the following fixations were established: TT-TT (TT screw at the cranial and caudal level), MCBT-MCBT (MCBT screw at the cranial and caudal level), hybrid MCBT-TT (MCBT screw at the cranial level and TT screw at the caudal level), and TT-MCBT (TT screw at the cranial level and MCBT screw at the caudal level). A 400-N compressive load with 7.5 N/m moments was applied to simulate flexion, extension, lateral bending, and rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation were compared. Results: Compared to the TT-TT group, the MCBT-TT showed a significant lower ROM of the L4-L5 segment (p ≤ 0.009), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.041). TT-MCBT groups showed a significant lower ROM of the L4-L5 segment (p ≤ 0.012), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.038). Conclusions: The biomechanical properties of the hybrid MCBT-TT and TT-MCBT techniques at the L4-L5 segment are superior to that of stability MCBT-MCBT and TT-TT techniques, and feasibility needs further cadaveric study to verify.

9.
Front Surg ; 9: 1028276, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36406344

RESUMO

Objectives: Compared with traditional pedicle screw trajectory, cortical bone trajectory (CBT) increases the contact surface between the screw and cortical bone where the screw is surrounded by dense cortical bone, which does not deform remarkably due to degeneration. We aimed to provide detailed information about the improvement of three-dimensional (3D)-printed navigation templates for modified CBT screw placement in the lumbar spine and evaluate the safety and accuracy thereof. Methods: Four human cadaveric lumbar spine specimens were selected. After CT scanning data were reconstructed to 3D models, either the left or right side of each specimen was randomly selected to establish a 3D-navigation template, mutually complemented with the surface anatomical structure of the lateral margin of the lumbar isthmus, vertebral plate, and spinous process. The corresponding 3D centrum was printed according to the CT scanning data, and a navigation template of supporting design was made according to modified cortical bone technique. The same template was used to insert CBT screws into 3D printed and cadaveric specimens. After the screws were inserted, the screw path of the 3D printed specimens was directly observed, and that of the anatomical specimens was scanned by CT, to determine the position and direction of the screws to analyze the success rate of screw placement. Results: Twenty cortical bone screws were placed in each of the 3D printed and anatomical specimens, with excellent rates of screw placement of 100% and 95%, respectively. Conclusions: We report the easy, safe, accurate, and reliable use of a 3D-printed navigation template to carry out screw placement by modified cortical bone technique in the lumbar spine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA