Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Surg ; 22(1): 441, 2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36575417

RESUMO

BACKGROUND: To compare the CT values and length of the screw tracks of traditional trajectory (TT), cortical bone trajectory (CBT), and modified cortical bone trajectory (MCBT) screws and investigate the effects on the biomechanics of lumbar fixation. METHODS: CT scan data of 60 L4 and L5 lumbar spine were retrieved and divided into 4 groups (10 male and 10 female cases in the 20-30 years old group and 20 male and 20 female cases in the 30-40 years old group). 3-dimentional (3D) model were established using Mimics 19.0 for each group and the placement of three techniques was simulated on the L4 and L5, and the part of the bone occupied by the screw track was set as the region of interest (ROI). The mean CT value and the actual length of the screw track were measured by Mimics 19.0. RESULTS: The CT values of ROI for the three techniques were significantly different between the same gander in each age group (P < 0.05). The difference of screw track lengths for CBT and MCBT in the male and female is significant (P < 0.05). CONCLUSIONS: According to the CT values of the three screw tracks: MCBT > CBT > TT, the MCBT screw track has greater bone-screw surface strength and longer screw tracks than CBT, which is easier to reach the anterior column of the vertebral body contributing to superior biomechanical properties.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Fenômenos Biomecânicos , Fusão Vertebral/métodos
2.
J Orthop Surg Res ; 18(1): 509, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37464385

RESUMO

BACKGROUND: This study aims to explore the measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar spine, and investigate its clinical significance. METHODS: The angle was measured on 120 normal adults' X-ray and 25 dry anatomical specimens. 60 screws were placed by junior residents on 6 wet specimens through the freehand technique. 30 screws were placed on one side with their original experience. After learning the techniques mentioned in the study, 30 screws were placed on the other side. The specimens were examined by X-ray and CT, and the angles of the screw paths and the integrity of the pedicle were evaluated. RESULTS: The angles of 120 subjects and 25 anatomical specimens show a gradually increasing trend. The differences among each segment were statistically significant (P < 0.05), but the difference in the same segment between the X-ray and the anatomical specimens was not statistically significant (P > 0.05). Furthermore, the differences in L1, L2, and L3 between the two genders were not statistically significant (P > 0.05). However, the angles were larger in female group than in male group in L4 and L5, and the differences were statistically significant (P < 0.05). The difference in the deviation rate of screw placement before and after the learning was statistically significant only in the L5 segment (P < 0.05). The difference in overall excellence rate was statistically significant (P < 0.05). CONCLUSIONS: The measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar can improve the accuracy of the lumbar sagittal screw angle.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Adulto , Humanos , Masculino , Feminino , Relevância Clínica , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Parafusos Ósseos , Radiografia
3.
J Healthc Eng ; 2022: 4826507, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35388332

RESUMO

There is no detailed biomechanical research about the hybrid CBT-TT (CBT screws at cranial level and TT screws at caudal level) and TT-CBT (TT screws at cranial level and CBT screws at caudal level) techniques with finite element (FE) method. Therefore, the purpose of this study was to evaluate and provide specific biomechanical data of the hybrid lumbar posterior fixation system and compare with traditional pedicle screw and cortical screw trajectories without fusion, in FE method. Specimens were from the anatomy laboratory of Xinjiang Medical University. Four FE models of the L4-L5 lumbar spine segment were generated. For each of these, four implanted models with the following instruments were created: bilateral traditional trajectory screw fixation (TT-TT), bilateral cortical bone trajectory screw fixation (CBT-CBT), hybrid CBT-TT fixation, and hybrid TT-CBT fixation. A 400 N compressive load with 7.5 Nm moments was applied so as to simulate flexion, extension, left lateral bending, right lateral bending, left rotation, and right rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation in four implanted models were compared. CBT-TT displayed a lower ROM of the fixation segment (3.82 ± 0.633°) compared to TT-TT (4.78 ± 0.306°) and CBT-CBT (4.23 ± 0.396°). In addition, CBT-TT showed a lower ROM of the posterior fixation (0.595 ± 0.108°) compared to TT-TT (0.795 ± 0.103°) and CBT-CBT (0.758 ± 0.052°). The intervertebral disc stress of CBT-TT (4.435 ± 0.604 MPa) was lower than TT-TT (7.592 ± 0.387 MPa) and CBT-CBT (6.605 ± 0.600 MPa). CBT-TT (20.228 ± 3.044 MPa) and TT-CBT (12.548 ± 2.914 MPa) displayed a lower peak von Mises stress of the posterior fixation compared to TT-TT (25.480 ± 3.737 MPa). The hybrid CBT-TT and TT-CBT techniques offered superior fixation strength compared to the CBT-CBT and TT-TT techniques.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Região Lombossacral/cirurgia , Amplitude de Movimento Articular , Fusão Vertebral/métodos
4.
Front Surg ; 9: 911742, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35923441

RESUMO

Background: Hybrid fixation techniques including the both modified cortical bone trajectory (MCBT) and traditional trajectory (TT) at the L4 and L5 lumbar segment are firstly proposed by our team. Therefore, the purpose of this study is to evaluate and provide specific biomechanical data of the hybrid fixation techniques including the MCBT and TT. Methods: Four human cadaveric specimens were from the anatomy laboratory of Xinjiang Medical University. Four finite-element (FE) models of the L4-L5 lumbar spine were generated. For each of them, four implanted models with the following fixations were established: TT-TT (TT screw at the cranial and caudal level), MCBT-MCBT (MCBT screw at the cranial and caudal level), hybrid MCBT-TT (MCBT screw at the cranial level and TT screw at the caudal level), and TT-MCBT (TT screw at the cranial level and MCBT screw at the caudal level). A 400-N compressive load with 7.5 N/m moments was applied to simulate flexion, extension, lateral bending, and rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation were compared. Results: Compared to the TT-TT group, the MCBT-TT showed a significant lower ROM of the L4-L5 segment (p ≤ 0.009), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.041). TT-MCBT groups showed a significant lower ROM of the L4-L5 segment (p ≤ 0.012), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.038). Conclusions: The biomechanical properties of the hybrid MCBT-TT and TT-MCBT techniques at the L4-L5 segment are superior to that of stability MCBT-MCBT and TT-TT techniques, and feasibility needs further cadaveric study to verify.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA