Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Artif Organs ; 45(5): 478-487, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35441547

RESUMO

PURPOSE: To evaluate the biomechanics effect of modified cortical bone screw technique (MCBT) with other traditional internal fixation systems on lumbar osteoporotic wet specimen. METHODS: Four different finite element models were established using CT data: (1) lumbar osteoporosis model without internal fixation system; (2) traditional pedicle screw technology (TT) model; (3) traditional cortical bone screw technology (CBT) model; (4) MCBT model. The changes of global displacement, intervertebral disc displacement of all models and internal fixation system Von Mises stress among the three models were compared under the same physiological load. RESULTS: Compared with the other three models, the total displacement of the modified CBT screw model was the smallest, with the maximum displacement of 0.216 mm; The intervertebral disc displacement of the modified CBT screw model was the smallest, with the maximum displacement of 0.149 mm; the internal fixation system Von Mises stress of the modified CBT screw technique model was the largest compared with the other three models, The maximum Von Mises stress is 232.73 MPa. CONCLUSION: Compared to traditional pedicle screw and traditional CBT, MCBT has better mechanical stability, and it is of certain clinical application value.


Assuntos
Deslocamento do Disco Intervertebral , Parafusos Pediculares , Fenômenos Biomecânicos , Densidade Óssea , Análise de Elementos Finitos , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia
2.
J Healthc Eng ; 2022: 4826507, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35388332

RESUMO

There is no detailed biomechanical research about the hybrid CBT-TT (CBT screws at cranial level and TT screws at caudal level) and TT-CBT (TT screws at cranial level and CBT screws at caudal level) techniques with finite element (FE) method. Therefore, the purpose of this study was to evaluate and provide specific biomechanical data of the hybrid lumbar posterior fixation system and compare with traditional pedicle screw and cortical screw trajectories without fusion, in FE method. Specimens were from the anatomy laboratory of Xinjiang Medical University. Four FE models of the L4-L5 lumbar spine segment were generated. For each of these, four implanted models with the following instruments were created: bilateral traditional trajectory screw fixation (TT-TT), bilateral cortical bone trajectory screw fixation (CBT-CBT), hybrid CBT-TT fixation, and hybrid TT-CBT fixation. A 400 N compressive load with 7.5 Nm moments was applied so as to simulate flexion, extension, left lateral bending, right lateral bending, left rotation, and right rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation in four implanted models were compared. CBT-TT displayed a lower ROM of the fixation segment (3.82 ± 0.633°) compared to TT-TT (4.78 ± 0.306°) and CBT-CBT (4.23 ± 0.396°). In addition, CBT-TT showed a lower ROM of the posterior fixation (0.595 ± 0.108°) compared to TT-TT (0.795 ± 0.103°) and CBT-CBT (0.758 ± 0.052°). The intervertebral disc stress of CBT-TT (4.435 ± 0.604 MPa) was lower than TT-TT (7.592 ± 0.387 MPa) and CBT-CBT (6.605 ± 0.600 MPa). CBT-TT (20.228 ± 3.044 MPa) and TT-CBT (12.548 ± 2.914 MPa) displayed a lower peak von Mises stress of the posterior fixation compared to TT-TT (25.480 ± 3.737 MPa). The hybrid CBT-TT and TT-CBT techniques offered superior fixation strength compared to the CBT-CBT and TT-TT techniques.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Região Lombossacral/cirurgia , Amplitude de Movimento Articular , Fusão Vertebral/métodos
3.
Front Surg ; 9: 911742, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35923441

RESUMO

Background: Hybrid fixation techniques including the both modified cortical bone trajectory (MCBT) and traditional trajectory (TT) at the L4 and L5 lumbar segment are firstly proposed by our team. Therefore, the purpose of this study is to evaluate and provide specific biomechanical data of the hybrid fixation techniques including the MCBT and TT. Methods: Four human cadaveric specimens were from the anatomy laboratory of Xinjiang Medical University. Four finite-element (FE) models of the L4-L5 lumbar spine were generated. For each of them, four implanted models with the following fixations were established: TT-TT (TT screw at the cranial and caudal level), MCBT-MCBT (MCBT screw at the cranial and caudal level), hybrid MCBT-TT (MCBT screw at the cranial level and TT screw at the caudal level), and TT-MCBT (TT screw at the cranial level and MCBT screw at the caudal level). A 400-N compressive load with 7.5 N/m moments was applied to simulate flexion, extension, lateral bending, and rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation were compared. Results: Compared to the TT-TT group, the MCBT-TT showed a significant lower ROM of the L4-L5 segment (p ≤ 0.009), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.041). TT-MCBT groups showed a significant lower ROM of the L4-L5 segment (p ≤ 0.012), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.038). Conclusions: The biomechanical properties of the hybrid MCBT-TT and TT-MCBT techniques at the L4-L5 segment are superior to that of stability MCBT-MCBT and TT-TT techniques, and feasibility needs further cadaveric study to verify.

4.
Biomed Mater Eng ; 28(6): 633-642, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29171968

RESUMO

OBJECTIVE: To investigate the effects of Uygur sand therapy on the mechanical properties of the femur bone of osteoarthritic rabbits. METHODS: Sixteen rabbits were injected with papain in the right posterior femoral articular cavity on the first, fourth and seventh day to establish the osteoarthritis (OA) rabbit model. Animals were divided into the experimental group and control group (8 rabbits each). The experimental group was treated with sand therapy, and the control group received no sand therapy treatment. Computed tomography (CT) scanning was used to collect the data of the femur before modeling, after modeling and 14 and 28 days after sand treatment. A 3D model of the femur was generated with the MIMIC software the bone layer was divided according to the different gray values and the change of the bone volume was analyzed. The body mesh is divided, and the material properties are given, then the three-point bending simulation is performed in Ansys. Additionally, the three-point bending test was performed on all the rabbits' femur to obtain the deflection and maximum stress values. And the effects of the sand treatment on the volume and mechanical properties of the bone were analyzed. Finally, the simulation results are compared with the experimental results, and the effects of sand treatment on the volume and mechanical properties of the bone are analyzed. RESULTS: (1) there is a tendency in the control group to convert the hard bone into dense bone and soft bone, while in the experimental group, the soft bone is converted into dense bone and hard bone obviously; (2) the morphological parameters of the experimental group are lower than those of the control group, whereas the maximum load, maximum normal stress, maximum shear stress of the experimental group are higher than those of the control group. (3) The mechanical test of three-point bending test was carried out using the three dimensional finite element model of rabbit femur. CONCLUSION: The sand therapy has positive effects on the volume distribution of bone layer and the mechanical properties of the femur of adult osteoarthritic rabbits.


Assuntos
Amoterapia , Fêmur/fisiopatologia , Osteoartrite/fisiopatologia , Osteoartrite/terapia , Amoterapia/métodos , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Fêmur/patologia , Masculino , Osteoartrite/patologia , Quartzo/uso terapêutico , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA