Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Card Surg ; 29(5): 678-85, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25040614

RESUMO

BACKGROUND: Total anomalous pulmonary venous connection (TAPVC) is a rare congenital heart disease (CHD), whose surgical repair is associated with high mortality and reoperation rates. We sought to identify predictors of early and late outcomes. METHODS: Data from medical records of patients who underwent surgical repair for TAPVC from 1989 to 2012 were included. The patients were divided in two groups, according to absence or presence of associated major CHDs. RESULTS: Forty-six patients were included (M/F: 26/20, median age 26 days, interquartile range 15 to 59, median weight 3.350 kg, interquartile range 1800 to 4470). Anatomic types of TAPVC were: supracardiac in 48%, intracardiac in 20%, infracardiac in 20%, and mixed in 12%; TAPVC was obstructive in 33%; TAPVC was isolated in 63%, complex in 37%. Single ventricle physiology was present in 11 patients, heterotaxy in eight patients. Overall operative mortality was 19.6% (9/46): 6.9% in isolated TAPVC, 41.2% in complex type (p-value: 0.002). It was associated with low weight at intervention (<3 kg, p = 0.027), single ventricle physiology (p = 0.047), and aortic cross-clamp time >60 minutes (p = 0.097). At a median follow-up of 2.97 years (range 43 days to 22 years, 91% complete), there were nine late deaths (24.3%); 15 patients (40.5%) had major events (including late death). Multivariate analysis of event-free survival showed worse outcome in the complex group (p = 0.001). CONCLUSION: Surgical mortality and morbidity remain consistent in patients with TAPVC and associated major CHD, while the isolated type shows excellent outcomes. Pulmonary vein obstruction is a rare but highly lethal complication. doi: 10.1111/jocs.12399 (J Card Surg 2014;29:678-685).


Assuntos
Síndrome de Cimitarra/cirurgia , Anormalidades Múltiplas , Peso Corporal , Cardiopatias Congênitas/complicações , Humanos , Lactente , Recém-Nascido , Masculino , Complicações Pós-Operatórias/prevenção & controle , Prognóstico , Pneumopatia Veno-Oclusiva/prevenção & controle , Estudos Retrospectivos , Síndrome de Cimitarra/complicações , Síndrome de Cimitarra/mortalidade , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos , Procedimentos Cirúrgicos Vasculares/mortalidade
2.
Gerodontology ; 29(2): e215-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21083743

RESUMO

OBJECTIVE: The effect of artificial ageing on the hardness, absorption, solubility, and colour of soft denture liners was investigated. MATERIALS AND METHODS: Liner materials based on acrylic resin (Trusoft) or silicone (Dentusil, Ufi Gel P, and Ufi Gel SC) were tested before and after 2000 thermal cycles. A total of 20 specimens of each material were tested. Half of the specimens were used for hardness and colour evaluation, and the remainder for absorption and solubility tests. The hardness evaluation was carried out using a Shore A durometer, while absorption and solubility tests were performed by storing samples in a desiccator and weighing daily until reaching constant mass (W1). After thermocycling, the samples were again weighed (W2) and dried (W3). Colour was measured using a spectrophotometer. Statistical analysis was performed using GraphPad InStat at the p < 0.05 level. RESULTS: Thermocycling significantly affected the hardness of the specimens. The Trusoft material exhibited the highest absorption (1.48 ± 0.48), solubility (1.26 ± 0.28), and colour change (3.92 ± 0.33), significantly different from the other materials. There were no significant differences among the silicones in terms of absorption, solubility, and colour change, except for the colour of Dentusil, which changed (0.83 ± 0.11). CONCLUSION: It can be concluded that silicone liners performed significantly better compared to acrylic resin.


Assuntos
Materiais Dentários/química , Reembasadores de Dentadura , Absorção , Resinas Acrílicas/química , Cor , Dessecação , Dimetilpolisiloxanos/química , Dureza , Humanos , Teste de Materiais , Metilmetacrilatos/química , Polimetil Metacrilato/química , Elastômeros de Silicone/química , Solubilidade , Espectrofotometria/instrumentação , Propriedades de Superfície , Temperatura , Fatores de Tempo
3.
Viruses ; 14(9)2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-36146731

RESUMO

Background: The present study aimed to examine longitudinal trends in hospitalizations for acute coronary syndrome (ACS) before and during the COVID-19 pandemic, by reviewing the data from 13 hospitals of the Veneto Region, in the north-east of Italy. Methods: We performed a multicenter, retrospective analysis including all the consecutive patients presenting with ACS and other acute cardiovascular (CV) conditions (defined as heart failure, arrhythmias, cardiac arrest and venous thromboembolism) hospitalized in 13 different hospitals of the Veneto Region covering a population of 2,554,818 inhabitants, during the first (between 15 March 2020 and 30 April 2020) and second (between 15 November 2020 and 30 December 2020) COVID-19 pandemic waves (the 2020 cohort). Data were compared with those obtained at the same time-windows of years 2018 and 2019 (the historical cohorts). Results: Compared to the historical cohorts, a significant decrease in the number of ACS cases was observed in 2020 (−27.3%, p = 0.01 and −32%, p < 0.001, comparing 2018 versus 2020 and 2019 and 2020, respectively). The proportion of patients hospitalized for acute CV conditions decreased during the first and second wave COVID-19 pandemic when compared to the historical cohorts (−36.5%, p < 0.001 and −40.6%, p < 0.001, comparing 2018 versus 2020 and 2019 and 2020, respectively). Pearson's correlation evidenced a significant inverse relationship between the number of COVID-19 cases and both ACS hospital admissions (r = −0.881, p = 0.005) and hospitalizations for acute CV conditions (r = −0.738, p = 0.01), respectively. Conclusions: The decrease in hospitalizations for ACS and other acute CV conditions will strongly affect future patients' management since undiagnosed nonfatal CV events represent a source of increased (and unknown) CV morbidity and mortality.


Assuntos
Síndrome Coronariana Aguda , COVID-19 , Doenças Cardiovasculares , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Doença Aguda , COVID-19/epidemiologia , Doenças Cardiovasculares/epidemiologia , Hospitalização , Humanos , Pandemias , Estudos Retrospectivos
4.
Viruses ; 14(9)2022 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-36146778

RESUMO

Background: During the COVID-19 pandemic, the risk of SARS-CoV-2 infection, the public health measures of social distancing, the freedom limitations, quarantine, and the enforced homeworking under the lockdown period, as well as medical causes including COVID-19 infection per se, may have caused major emotional distress, especially in the most vulnerable patients. We aimed to evaluate the variations in the number of admissions due to Takotsubo syndrome (TTS) during the COVID-19 pandemic in the Veneto region. Methods: We retrospectively reviewed and analyzed the number of admissions because of TTS in 13 Divisions of Cardiology located in the Veneto region, the northeastern area of Italy, covering a population of more than 2.5 million inhabitants, during the two major pandemic waves of COVID-19 (the first between 15 March and 30 April 2020 and the second between 15 November and 30 December 2020) that occurred in 2020. Results: In total, 807 acute coronary syndromes were admitted in the 13 enrolling hospitals. Among these, 3.9% had TTS. Compared to the corresponding 2018 and 2019 time periods, we observed a significant increase in the number of TTS cases (+15.6%, p = 0.03 and +12.5%, p = 0.04, comparing 2018 to 2020 and 2019 to 2020, respectively). Geographical distribution of the TTS cases reflected the broad spread of the SARS-CoV-2 infection with a significant direct relationship between TTS incidence and the number of COVID-19 infections according to Pearson's correlation (r = 0.798, p < 0.001). Conclusions: The higher incidence of TTS during the 2020 COVID-19 pandemic waves, especially in the areas that were hit hardest in terms of morbidity and mortality by the SARS-CoV-2 infection, suggest a strong direct and/or indirect role of COVID-19 in the pathogenesis of TTS.


Assuntos
COVID-19 , Cardiomiopatia de Takotsubo , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Humanos , Itália/epidemiologia , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Cardiomiopatia de Takotsubo/epidemiologia
5.
J Cardiovasc Dev Dis ; 8(10)2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34677186

RESUMO

Fontan-associated liver disease (FALD) is an arising clinical entity that can occur long after a successful Fontan operation for correction of single ventricle (SV) congenital heart disease (CHD). Occurrence of FALD is characterized by liver cirrhosis and other hepatic complications, and determinates an increased morbidity and mortality. Currently, there is no consensus on how to stage FALD. We report here our experience by an observational study in 52 patients with SV-CHD after Fontan operation that were recruited through a period of 36 ± 9.3 months. All cases underwent lab tests and liver and cardiac imaging evaluation, including liver stiffness (LS) measurement by transient elastography (TE) (FibroScan®). According to selective criteria for liver disease, we identified 23/43 (53.5%) cases with advanced FALD that showed: older age (p < 0.05), larger hepatic and cava veins diameter (p < 0.05), worsened NYHA class (p < 0.05), abnormal lymphocytes (p < 0.01), platelet count (p < 0.05), and GGT, prothrombin time (INR), albumin and cystatin C levels (p < 0.05), with respect to cases without advanced FALD. LS values were significantly increased in cases with advanced FALD, at cut-off values higher than 22 kPa (p < 0.001). LS, and its combined score with spleen diameter and platelet count (LSPS) successfully helped to detect 100% of cases with portal hypertension (p < 0.001). In conclusion, LS can be effective to stage FALD and to uncover cases with severe risk of complications, avoiding higher morbidity and mortality related to advanced FALD.

6.
J Cardiovasc Echogr ; 31(2): 68-72, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34485031

RESUMO

BACKGROUND: The great technological advancements in the field of echocardiography have led to applications of stress echocardiography (SE) in almost all diagnostic fields of cardiology, from ischemic heart disease to valvular heart disease and diastolic function. However, the assessment of the right ventricle (RV) in general, and in particular in regard to the contractile reserve of the RV, is an area that has not been previously explored. We, therefore, propose a study to investigate the potential use of SE for the assessment of RV function in adult patients. AIMS AND OBJECTIVES: The primary aim is to evaluate the feasibility of right ventricular SE. The secondary aim is to assess right ventricular contractile reserve. MATHERIALS AND METHODS: Eighty-one patients undergoing a physical or dobutamine stress echocardiogram for cardiovascular risk stratification or chest pain were the subject of the study. An exercise leg cycle using a standard WHO protocol was used to simultaneously assess the right and left ventricular global and regional function as well as acquiring Doppler data. Whereas the patient had limitations in mobility, a dobutamine SE was be performed. We evaluated the average values of tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), S-wave, systolic pulmonary artery pressure (sPAP), and right ventricle global longitudinal (free wall) strain (RVGLS) during baseline and at the peak of the effort. RV contractile reserve was defined as the change in RVGLS from rest to peak exercise. We also assessed the reproducibility of these measurements between two different expert operators (blind analysis). RESULTS: At least 3 over 5 RV function parameters were measurable both during baseline and at the peak of the effort in 95% of patients, while all 5 parameters in 65% of our population, demonstrating an excellent feasibility. All RV-studied variables showed a statistically significant increase (P < 0.001) at peak compared to the baseline. The average percentage increases at peak were 31.1% for TAPSE, 24.8% for FAC, 50.6% for S-wave, 55.2% for PAPS, and 39.8% for RV strain. The reproducibility between operators at baseline and peak was excellent. Our study demonstrates that TAPSE, FAC, and S-wave are highly feasible at rest and at peak, while TAPSE, S-wave, and sPAP are the most reliable measurements during RV stress echo. CONCLUSION: RVGLS is useful in the assessment of RV contractile reserve in patients with good acoustic window. Further studies are needed to evaluate the impact of contrast echocardiography in improving RV contractile reserve assessment during SE.

7.
J Craniofac Surg ; 21(4): 1270-3, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20613613

RESUMO

Both the cleaning and care of the prosthesis are fundamental for maintaining its quality. Therefore, the aim of this study was to show the methods of cleaning and care the patient needs to take as regards the prosthesis and adjacent tissue, starting with correct instruction and training by the professional. It has been verified that among the materials for fabricating maxillofacial prostheses, silicone was considered the major retainer of microorganisms on its surface. Therefore, for cleaning prostheses, the use of water and neutral soap, as well as chlorhexidine, is recommended. As regards care of the adjacent tissues, it is recommended to remove the prosthesis before going to sleep, in addition to washing the prosthesis receptor tissues with water and neutral soap or with a mixture of hydrogen peroxide and water. Whereas for the mucosal surfaces of the ophthalmic cavity, cleaning with filtered and boiled water or physiological solution at least 3 times a day is recommended.


Assuntos
Descontaminação/métodos , Prótese Maxilofacial , Clorexidina , Humanos , Peróxido de Hidrogênio , Silicones , Sabões , Água
8.
J Coll Physicians Surg Pak ; 19(10): 670-1, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19811725

RESUMO

Hand deformities affect aesthetics function of hand severely compromised and also cause psychological disturbances. This report describes the fabrication of a silicone finger prosthesis for a patient after an accident at work. The finger prosthesis was retained by a vacuum effect on the stump. The silicone material Silastic-MDX 44210 was used to provide function and aesthetics. The finger prosthesis offered psychological, functional and rehabilitative advantages for the patient. Restoring the natural appearance with the prosthesis eliminated the trauma generated by the dysfunction and represented an efficient psychological therapy.


Assuntos
Membros Artificiais , Traumatismos dos Dedos/reabilitação , Dedos/cirurgia , Acidentes de Trabalho , Amputação Traumática/psicologia , Amputação Traumática/reabilitação , Traumatismos dos Dedos/psicologia , Humanos , Elastômeros de Silicone
9.
Prim Dent Care ; 16(3): 127-30, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19566987

RESUMO

INTRODUCTION: Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners. AIM: The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing. METHODS: Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction. RESULTS: These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale. CONCLUSIONS: Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.


Assuntos
Materiais Dentários/química , Reembasadores de Dentadura , Absorção , Cor , Dimetilpolisiloxanos/química , Elasticidade , Dureza , Humanos , Teste de Materiais , Polimetil Metacrilato/química , Saliva Artificial/química , Elastômeros de Silicone/química , Solubilidade , Espectrofotometria Ultravioleta , Propriedades de Superfície , Temperatura , Fatores de Tempo , Viscosidade
10.
J Prosthodont ; 18(1): 32-5, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19166546

RESUMO

PURPOSE: The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin. MATERIALS AND METHODS: Thirty-two test specimen investments were obtained in two silicones. A segment was cut in each test specimen, and each specimen was fixed in an acrylic disk. The specimens were then polished and submitted to the first microhardness test before immersion in distilled water and incubation for 2 months. During this 2-month period, the specimens were immersed in a water bath at 37 degrees C and were disinfected daily; half were disinfected with neutral soap and the other half were disinfected with 4% chlorhexidine gluconate. After the storage phase and disinfection, a second microhardness test was performed. The surface microhardness values for the acrylic resins were submitted to ANOVA, followed by the Tukey test. RESULTS: The disinfection and the period of storage did not statistically influence the surface microhardness of the acrylic resin, independent of the method of investment of the specimens (Zetalabor or Vipi Sil). The investment of specimens with Zetalabor silicone presented a greater surface hardness, independent of the type of disinfection and the period of storage. CONCLUSIONS: Based on these results, we suggest that the microhardness of the resin evaluated was not influenced by the method of disinfection or the time of storage used and was affected only by the investment material.


Assuntos
Resinas Acrílicas/química , Desinfecção/métodos , Olho Artificial , Silicones/química , Clorexidina/análogos & derivados , Desinfetantes , Dureza , Humanos , Teste de Materiais , Micro-Ondas , Distribuição Aleatória , Sabões , Propriedades de Superfície , Ceras
11.
Braz Oral Res ; 32: e42, 2018 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-29846390

RESUMO

Based on aroeira's (Myracrodruon urundeuva) antimicrobial activity and a future trend to compose intracanal medication, the aim of this study was to assess in vivo inflamatory tissue response to the extracts by edemogenic and histological analysis containing inactivated facultative and anaerobic microorganisms. For edema quantification, eighteen animals were divided into three groups (n = 3, periods: 3 and 6 hours) and 0.2 mL of 1% Evans blue per 100 g of body weight was injected into the penile vein under general anesthesia. After 30 min the animals received a subcutaneous injection in the dorsal region of aqueous or ethanolic extract of aroeira or saline (control) containing inactivated bacteria. Samples were collected, immersed in formamide for 72h, and evaluated by spectrophotometry (630 m). For histological analysis, polyethylene tubes with the extracts were implanted in the dorsal of 30 male rats. Analysis of the fibrous capsule and inflammatory infiltrate were performed after 7 and 30 days. The aqueous extract group induced less edema in both postoperative periods compared to the other groups, but the differences were not significant (p > 0.05). Tissue repair was significantly better after 30 days than after 7 days (p < 0.01). The aqueous solution showed less inflammatory response than the ethanolic solution (p < 0.05), with tendency for better results than control after 7 days. After 30 days, the response to both extracts was similar to control. The aqueous and ethanolic aroeira extracts containing inactivated microorganisms showed a trend for better results than saline, even when associated with microorganisms, and facilitated the tissue repair process.


Assuntos
Anacardiaceae/química , Edema/prevenção & controle , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Inflamação/prevenção & controle , Extratos Vegetais/farmacologia , Tela Subcutânea/microbiologia , Animais , Edema/patologia , Bactérias Gram-Negativas/classificação , Bactérias Gram-Positivas/classificação , Inflamação/patologia , Masculino , Ratos , Ratos Wistar , Tela Subcutânea/efeitos dos fármacos , Tela Subcutânea/patologia , Fatores de Tempo
12.
Cardiovasc Pathol ; 11(4): 217-20, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12140127

RESUMO

We report an unusual case of bicuspid aortic valve in a 67-year-old man who had aortic valve replacement for combined severe aortic stenosis with moderate aortic regurgitation. Both preoperative echocardiography and angiocardiography failed to recognize the bicuspid nature of the aortic valve, which was discovered only at surgical pathology examination. The atypical anatomic findings of the valve consisted of a "cleft-like" appearance of the ventral leaflet formed by the two conjoined cusps together with a fenestrated rudimental raphe.


Assuntos
Valva Aórtica/anormalidades , Idoso , Valva Aórtica/embriologia , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Humanos , Masculino
14.
Braz. oral res. (Online) ; 32: e42, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889494

RESUMO

Abstract: Based on aroeira's (Myracrodruon urundeuva) antimicrobial activity and a future trend to compose intracanal medication, the aim of this study was to assess in vivo inflamatory tissue response to the extracts by edemogenic and histological analysis containing inactivated facultative and anaerobic microorganisms. For edema quantification, eighteen animals were divided into three groups (n = 3, periods: 3 and 6 hours) and 0.2 mL of 1% Evans blue per 100 g of body weight was injected into the penile vein under general anesthesia. After 30 min the animals received a subcutaneous injection in the dorsal region of aqueous or ethanolic extract of aroeira or saline (control) containing inactivated bacteria. Samples were collected, immersed in formamide for 72h, and evaluated by spectrophotometry (630 m). For histological analysis, polyethylene tubes with the extracts were implanted in the dorsal of 30 male rats. Analysis of the fibrous capsule and inflammatory infiltrate were performed after 7 and 30 days. The aqueous extract group induced less edema in both postoperative periods compared to the other groups, but the differences were not significant (p > 0.05). Tissue repair was significantly better after 30 days than after 7 days (p < 0.01). The aqueous solution showed less inflammatory response than the ethanolic solution (p < 0.05), with tendency for better results than control after 7 days. After 30 days, the response to both extracts was similar to control. The aqueous and ethanolic aroeira extracts containing inactivated microorganisms showed a trend for better results than saline, even when associated with microorganisms, and facilitated the tissue repair process.


Assuntos
Animais , Masculino , Ratos , Anacardiaceae/química , Edema/prevenção & controle , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Inflamação/prevenção & controle , Extratos Vegetais/farmacologia , Tela Subcutânea/microbiologia , Edema/patologia , Bactérias Gram-Negativas/classificação , Bactérias Gram-Positivas/classificação , Inflamação/patologia , Ratos Wistar , Tela Subcutânea/efeitos dos fármacos , Tela Subcutânea/patologia , Fatores de Tempo
15.
J Coll Physicians Surg Pak ; 22(11): 716-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23146853

RESUMO

Patients with congenital malformations, traumatic or pathological mutilation and maxillofacial developmental disorders can be restored aesthetically and emotionally by the production and use of facial prostheses. The aim of this study was to review the literature about the retention and processing methods of facial prostheses, and discuss their characteristics. A literature review on Medline (PubMed) database was performed by using the keywords "maxillofacial prosthesis, silicone, esin, pigment, cosmetic, prosthetic nose", based on articles published from 1956 to 2010. Several methods of retention, from adhesives to the placement of implants, and different processing methods such as laser, CAD/CAM and rapid prototyping technologies have been reported. There are advantages and disadvantages of each procedure, and none can be classified as better compared to others.


Assuntos
Anormalidades Craniofaciais/cirurgia , Prótese Maxilofacial , Nariz/cirurgia , Desenho de Prótese , Falha de Prótese , Implantação de Prótese/métodos , Adesivos , Desenho Assistido por Computador , Humanos , Procedimentos Cirúrgicos Nasais/estatística & dados numéricos , Implantação de Prótese/estatística & dados numéricos , Procedimentos de Cirurgia Plástica/métodos , Resinas Sintéticas
16.
Int J Prosthodont ; 24(2): 155-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21479284

RESUMO

The aim of this study was to evaluate the effects of carbamide peroxide (CP) on surfaces of different restorative materials. Porcelain, composite resin, glass ionomer, and amalgam were analyzed in this study. Surface roughness (Ra) was measured before and after treatment with 10% and 15% CP. Fifteen percent CP increased Ra values in both the glass ionomer and amalgam subgroups, while 10% CP increased Ra values in the glass ionomer subgroup only. Changes in restorative material surfaces can be more severe when bleaching is completed without a clinician's supervision. Hence, thorough patient examinations must be done before, during, and after bleaching treatment.


Assuntos
Materiais Dentários/química , Peróxidos/química , Clareadores Dentários/química , Ureia/análogos & derivados , Peróxido de Carbamida , Resinas Compostas/química , Amálgama Dentário/química , Polimento Dentário/métodos , Porcelana Dentária/química , Cimentos de Ionômeros de Vidro/química , Humanos , Umidade , Teste de Materiais , Cimentos de Resina/química , Resinas Sintéticas/química , Propriedades de Superfície , Temperatura , Fatores de Tempo , Ureia/química
17.
Cardiovasc Intervent Radiol ; 32(3): 563-7, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-18791763

RESUMO

We report the case of a very large anomalous connection of the veins draining the upper lobe of the left lung to both the left-sided vertical vein and the left atrium, associated with mild rheumatic mitral valve stenosis, in which the atrial septum was intact and the remaining venous system, including the coronary sinus, was otherwise normal (a variant of Lutembacher's syndrome). In order to abolish the left-to-right shunting, a transcatheter approach to close this venous structure was successfully attempted using an Amplatzer ASD Occluder device. The technical aspects and the alternative options of performing a procedure with a device for a purpose outside the scope of its approved label are discussed.


Assuntos
Anomalias dos Vasos Coronários/terapia , Síndrome de Lutembacher/terapia , Veias Pulmonares/anormalidades , Idoso , Cateterismo Cardíaco , Comorbidade , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Síndrome de Lutembacher/diagnóstico
18.
Braz Oral Res ; 23(2): 144-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19684948

RESUMO

One of the greatest challenges faced by buccomaxillofacial prosthetists is to reproduce the patient's exact skin color and provide adequate esthetics. To reach this objective, professionals must use materials with easy characterization and that maintain color over long periods of time. The objective of this study was, thus, to evaluate the color stability of two types of silicones, Silastic 732 and Silastic MDX4-4210. Twenty-four test specimens were made from each type of silicone and were divided into a colorless group and groups intrinsically pigmented with ceramics, cosmetics or iron oxide. The specimens were submitted to an accelerated system of aging for non-metallic materials. Readings were carried out initially and after periods corresponding to 163, 351, 692 and 1,000 hours of aging, using a reflection spectrophotometer analysis, and color alterations were calculated by the CIE L*a*b* system. The data were submitted to variance analysis and Tukey's test at a 5% level of probability. The results demonstrated that, irrespective of the period of time analyzed, all the materials underwent some type of chromatic alteration (DeltaE > 0). The test specimens made with Silastic 732 and MDX4-4210, without pigmentation, presented the lowest color alteration values after 1,000 hours of aging. Of the pigments, ceramic presented the lowest color alteration values and cosmetic powder presented the highest values. Thus, it may be concluded that the materials without the incorporation of pigments presented similar color alteration values, and did not differ statistically. The cosmetic powder used in this study was the pigment that most altered the color of the test specimens.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Elastômeros de Silicone/química , Análise de Variância , Cor , Corantes , Teste de Materiais , Pigmentação , Elastômeros de Silicone/efeitos da radiação , Espectrofotometria , Temperatura , Fatores de Tempo
19.
Indian J Dent Res ; 20(1): 77-80, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19336865

RESUMO

OBJECTIVES: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. MATERIALS AND METHODS: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. RESULTS: All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Silicones/química , Cor , Percepção de Cores , Corantes , Dimetilpolisiloxanos/química , Teste de Materiais , Desenho de Prótese , Elastômeros de Silicone/química , Fatores de Tempo
20.
Braz. oral res ; 23(2): 144-148, 2009. tab
Artigo em Inglês | LILACS | ID: lil-522294

RESUMO

One of the greatest challenges faced by buccomaxillofacial prosthetists is to reproduce the patient's exact skin color and provide adequate esthetics. To reach this objective, professionals must use materials with easy characterization and that maintain color over long periods of time. The objective of this study was, thus, to evaluate the color stability of two types of silicones, Silastic 732 and Silastic MDX4-4210. Twenty-four test specimens were made from each type of silicone and were divided into a colorless group and groups intrinsically pigmented with ceramics, cosmetics or iron oxide. The specimens were submitted to an accelerated system of aging for non-metallic materials. Readings were carried out initially and after periods corresponding to 163, 351, 692 and 1,000 hours of aging, using a reflection spectrophotometer analysis, and color alterations were calculated by the CIE L*a*b* system. The data were submitted to variance analysis and Tukey's test at a 5 percent level of probability. The results demonstrated that, irrespective of the period of time analyzed, all the materials underwent some type of chromatic alteration (ÄE > 0). The test specimens made with Silastic 732 and MDX4-4210, without pigmentation, presented the lowest color alteration values after 1,000 hours of aging. Of the pigments, ceramic presented the lowest color alteration values and cosmetic powder presented the highest values. Thus, it may be concluded that the materials without the incorporation of pigments presented similar color alteration values, and did not differ statistically. The cosmetic powder used in this study was the pigment that most altered the color of the test specimens.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Elastômeros de Silicone/química , Análise de Variância , Cor , Corantes , Teste de Materiais , Pigmentação , Espectrofotometria , Elastômeros de Silicone/efeitos da radiação , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA