Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Circulation ; 139(14): 1710-1724, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30586764

RESUMO

BACKGROUND: Pulmonary arterial hypertension (PAH) is a life-threatening disorder of the pulmonary circulation associated with loss and impaired regeneration of microvessels. Reduced pericyte coverage of pulmonary microvessels is a pathological feature of PAH and is caused partly by the inability of pericytes to respond to signaling cues from neighboring pulmonary microvascular endothelial cells (PMVECs). We have shown that activation of the Wnt/planar cell polarity pathway is required for pericyte recruitment, but whether production and release of specific Wnt ligands by PMVECs are responsible for Wnt/planar cell polarity activation in pericytes is unknown. METHODS: Isolation of pericytes and PMVECs from healthy donor and PAH lungs was carried out with 3G5 or CD31 antibody-conjugated magnetic beads. Wnt expression profile of PMVECs was documented via quantitative polymerase chain reaction with a Wnt primer library. Exosome purification from PMVEC media was carried out with the ExoTIC device. Hemodynamic profile, right ventricular function, and pulmonary vascular morphometry were obtained in a conditional endothelium-specific Wnt5a knockout ( Wnt5aECKO) mouse model under normoxia, chronic hypoxia, and hypoxia recovery. RESULTS: Quantification of Wnt ligand expression in healthy PMVECs cocultured with pericytes demonstrated a 35-fold increase in Wnt5a, a known Wnt/planar cell polarity ligand. This Wnt5a spike was not seen in PAH PMVECs, which correlated with an inability to recruit pericytes in Matrigel coculture assays. Exosomes purified from media demonstrated an increase in Wnt5a content when healthy PMVECs were cocultured with pericytes, a finding that was not observed in exosomes of PAH PMVECs. Furthermore, the addition of either recombinant Wnt5a or purified healthy PMVEC exosomes increased pericyte recruitment to PAH PMVECs in coculture studies. Although no differences were noted in normoxia and chronic hypoxia, Wnt5aECKO mice demonstrated persistent pulmonary hypertension and right ventricular failure 4 weeks after recovery from chronic hypoxia, which correlated with significant reduction, muscularization, and decreased pericyte coverage of microvessels. CONCLUSIONS: We identify Wnt5a as a key mediator for the establishment of pulmonary endothelium-pericyte interactions, and its loss could contribute to PAH by reducing the viability of newly formed vessels. We speculate that therapies that mimic or restore Wnt5a production could help prevent loss of small vessels in PAH.


Assuntos
Movimento Celular , Células Endoteliais/metabolismo , Pericitos/metabolismo , Hipertensão Arterial Pulmonar/metabolismo , Artéria Pulmonar/metabolismo , Proteína Wnt-5a/deficiência , Adolescente , Adulto , Animais , Estudos de Casos e Controles , Hipóxia Celular , Polaridade Celular , Células Cultivadas , Criança , Técnicas de Cocultura , Modelos Animais de Doenças , Células Endoteliais/patologia , Exossomos/metabolismo , Exossomos/patologia , Feminino , Humanos , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Pessoa de Meia-Idade , Neovascularização Patológica , Comunicação Parácrina , Pericitos/patologia , Hipertensão Arterial Pulmonar/genética , Hipertensão Arterial Pulmonar/patologia , Artéria Pulmonar/patologia , Ratos , Via de Sinalização Wnt , Proteína Wnt-5a/genética
2.
Environ Sci Technol ; 47(4): 1937-44, 2013 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-23331021

RESUMO

A low cost, microfluidic paper electrochemical device (µPED) was fabricated using screen printing of electrodes and heat transfer of patterned wax paper onto filter paper. The µPED features films of a light-emitting ruthenium metallopolymer, microsomal metabolic enzymes, and DNA to detect potential genotoxic pollutant activity in environmental samples. Unlike conventional analytical methods that detect specific pollutant compounds, the µPED was designed to rapidly measure the presence of genotoxic equivalents in environmental samples with the signal related to benzo[a]pyrene (B[a]P) as a reference standard. The analytical end point is the detection of DNA damage from metabolites produced in the device using an electrochemiluminescence output measured with a charge-coupled device (CCD) camera. Proof-of-concept of this measurement was established for smoke, water, and food samples. The µPED provides a rapid screening tool for on-site environmental monitoring that specifically monitors the genotoxic reactivity of metabolites of toxic compounds present in the samples.


Assuntos
Técnicas Eletroquímicas , Poluentes Ambientais/análise , Medições Luminescentes , Técnicas Analíticas Microfluídicas , Mutagênicos/análise , Técnicas Analíticas Microfluídicas/instrumentação , Testes de Mutagenicidade , Papel
3.
Anal Chem ; 84(23): 10485-91, 2012 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-23121341

RESUMO

We report here the first kinetic characterization of 1 µm diameter superparamagnetic particles (MP) decorated with over 100,000 antibodies binding to protein antigens attached to flat surfaces. Surface plasmon resonance (SPR) was used to show that these antibody-derivatized MPs (MP-Ab(2)) exhibit irreversible binding with 100-fold increased association rates compared to free antibodies. The estimated upper limit for the dissociation constant of MP-Ab(2) from the SPR sensor surface is 5 fM, compared to 3-8 nM for the free antibodies. These results are explained by up to 2000 interactions of MP-Ab(2) with protein-decorated surfaces. Findings are consistent with highly efficient capture of protein antigens in solution by the MP-Ab(2) and explain in part the utility of these beads for ultrasensitive protein detection into the fM and aM range. Aggregation of these particles on the SPR chip, probably due to residual magnetic microdomains in the particles, also contributes to ultrasensitive detection and may also help drive the irreversible binding.


Assuntos
Anticorpos/imunologia , Técnicas Biossensoriais , Proteínas Imobilizadas/metabolismo , Interleucina-6/metabolismo , Calicreínas/metabolismo , Nanopartículas de Magnetita , Antígeno Prostático Específico/metabolismo , Anticorpos/metabolismo , Ouro/química , Humanos , Proteínas Imobilizadas/imunologia , Interleucina-6/imunologia , Calicreínas/imunologia , Antígeno Prostático Específico/imunologia , Ressonância de Plasmônio de Superfície
4.
Anal Chem ; 83(24): 9499-506, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22040095

RESUMO

A novel, simple, rapid microfluidic array using bioelectronically driven cytochrome P450 enzyme catalysis for reactive metabolite screening is reported for the first time. The device incorporates an eight-electrode screen-printed carbon array coated with thin films of DNA, [Ru(bpy)(2)(PVP)(10)](ClO(4)) {RuPVP}, and rat liver microsomes (RLM) as enzyme sources. Catalysis features electron donation to cyt P450 reductase in the RLMs and subsequent cyt P450 reduction while flowing an oxygenated substrate solution past sensor electrodes. Metabolites react with DNA in the film if they are able, and damaged DNA is detected by catalytic square wave voltammetry (SWV) utilizing the RuPVP polymer. The microfluidic device was tested for a set of common pollutants known to form DNA-reactive metabolites. Logarithmic turnover rates based on SWV responses gave excellent correlation with the rodent liver TD(50) toxicity metric, supporting the utility of the device for toxicity screening. The microfluidic array gave much better S/N and reproducibility than single-electrode sensors based on similar principles.


Assuntos
Sistema Enzimático do Citocromo P-450/metabolismo , Técnicas Eletroquímicas , Técnicas Analíticas Microfluídicas , Animais , Complexos de Coordenação/química , DNA/química , DNA/metabolismo , Adutos de DNA/análise , Dano ao DNA , Eletrodos , Microssomos Hepáticos/enzimologia , Ratos , Rutênio/química
5.
Electrochem commun ; 11(4): 819-822, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20161158

RESUMO

We report herein a simple device for rapid biosensing consisting of a single microfluidic channel made from poly(dimethylsiloxane) (PDMS) coupled to an injector, and incorporating a biocatalytic sensing electrode, reference and counter electrodes. The sensing electrode was a gold wire coated with 5 nm glutathione-decorated gold nanoparticles (AuNPs). Sensitive detection of H(2)O(2) based on direct bioelectrocatalysis by horseradish peroxidase (HRP) was used for evaluation. HRP was covalently linked the glutathione-AuNPs. This electrode presented quasi-reversible cyclic voltammetry peaks at -0.01 V vs Ag/AgCl at pH 6.5 for the HRP heme Fe(III)/Fe(II) couple. Direct electrochemical activity of HRP was used to detect H(2)O(2) at high sensitivity with a detection limit of 5 nM in an unmediated system.

6.
Adv Biosyst ; 3(1): e1800223, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32627339

RESUMO

Tumor microenvironment and the interplay of physical and mechanical forces are key determinants of cancer initiation, progression, and response to drug treatment. However, the impact of tumor microenvironment on cancer progression is poorly understood, in large due to the lack of in vitro models that recapitulate the physical aspects of tumor microenvironment. Herein, a simple, dynamic 3D nonsmall cell lung carcinoma culture using a multichannel microfluidic model platform is developed for evaluating the contribution of flow-induced hydrodynamic shear stress on epithelial-to-mesenchymal transition (EMT). It is found that flow induces changes in cellular morphology and EMT in 2D and 3D when lung cancer A549 cells are cultured on a microfluidic chip under laminar flow for 4-5 days compared to traditional static cultures. The role of dynamic cell culture on chemotherapeutic effects is monitored. Drug response with an existing anti-cancer drug, e.g., erlotinib and an investigational drug (NSC-750212), shows distinct cytotoxic effects in flow compared to static cultures, suggesting a potential influence of flow on drug efficacy in 2D and 3D models. The platform demonstrates the ability to create a dynamic microscale tumor model, which could be explored as a tool for early drug screening and treatment monitoring in cancer and other diseases.

7.
Adv Mater ; 30(4)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29215164

RESUMO

In nature, cells self-assemble at the microscale into complex functional configurations. This mechanism is increasingly exploited to assemble biofidelic biological systems in vitro. However, precise coding of 3D multicellular living materials is challenging due to their architectural complexity and spatiotemporal heterogeneity. Therefore, there is an unmet need for an effective assembly method with deterministic control on the biomanufacturing of functional living systems, which can be used to model physiological and pathological behavior. Here, a universal system is presented for 3D assembly and coding of cells into complex living architectures. In this system, a gadolinium-based nonionic paramagnetic agent is used in conjunction with magnetic fields to levitate and assemble cells. Thus, living materials are fabricated with controlled geometry and organization and imaged in situ in real time, preserving viability and functional properties. The developed method provides an innovative direction to monitor and guide the reconfigurability of living materials temporally and spatially in 3D, which can enable the study of transient biological mechanisms. This platform offers broad applications in numerous fields, such as 3D bioprinting and bottom-up tissue engineering, as well as drug discovery, developmental biology, neuroscience, and cancer research.


Assuntos
Engenharia Tecidual , Bioimpressão
8.
ACS Nano ; 11(11): 10712-10723, 2017 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-29090896

RESUMO

Circulating tumor-derived extracellular vesicles (EVs) have emerged as a promising source for identifying cancer biomarkers for early cancer detection. However, the clinical utility of EVs has thus far been limited by the fact that most EV isolation methods are tedious, nonstandardized, and require bulky instrumentation such as ultracentrifugation (UC). Here, we report a size-based EV isolation tool called ExoTIC (exosome total isolation chip), which is simple, easy-to-use, modular, and facilitates high-yield and high-purity EV isolation from biofluids. ExoTIC achieves an EV yield ∼4-1000-fold higher than that with UC, and EV-derived protein and microRNA levels are well-correlated between the two methods. Moreover, we demonstrate that ExoTIC is a modular platform that can sort a heterogeneous population of cancer cell line EVs based on size. Further, we utilize ExoTIC to isolate EVs from cancer patient clinical samples, including plasma, urine, and lavage, demonstrating the device's broad applicability to cancers and other diseases. Finally, the ability of ExoTIC to efficiently isolate EVs from small sample volumes opens up avenues for preclinical studies in small animal tumor models and for point-of-care EV-based clinical testing from fingerprick quantities (10-100 µL) of blood.


Assuntos
Biomarcadores Tumorais/sangue , Detecção Precoce de Câncer , Exossomos/genética , Ultracentrifugação/métodos , Proteínas Sanguíneas/isolamento & purificação , Exossomos/química , Vesículas Extracelulares/genética , Humanos , MicroRNAs/sangue , Neoplasias/sangue , Neoplasias/patologia , Células Neoplásicas Circulantes/química , Células Neoplásicas Circulantes/patologia
10.
Sci Rep ; 6: 35845, 2016 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-27775039

RESUMO

Access to point-of-care (POC), rapid, inexpensive, sensitive, and instrument-free tests for the diagnosis of tuberculosis (TB) remains a major challenge. Here, we report a simple and low-cost microchip-based TB ELISA (MTBE) platform for the detection of anti-mycobacterial IgG in plasma samples in less than 15 minutes. The MTBE employs a flow-less, magnet-actuated, bead-based ELISA for simultaneous detection of IgG responses against multiple mycobacterial antigens. Anti-trehalose 6,6'-dimycolate (TDM) IgG responses were the strongest predictor for differentiating active tuberculosis (ATB) from healthy controls (HC) and latent tuberculosis infections (LTBI). The TDM-based MTBE demonstrated superior sensitivity compared to sputum microscopy (72% vs. 56%) with 80% and 63% positivity among smear-positive and smear-negative confirmed ATB samples, respectively. Receiver operating characteristic analysis indicated good accuracy for differentiating ATB from HC (AUC = 0.77). Thus, TDM-based MTBE can be potentially used as a screening device for rapid diagnosis of active TB at the POC.

11.
Adv Drug Deliv Rev ; 78: 105-17, 2014 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-24882226

RESUMO

Infectious diseases are the leading cause of death worldwide. Among them, tuberculosis (TB) remains a major threat to public health, exacerbated by the emergence of multiple drug-resistant (MDR) and extensively drug-resistant (XDR) Mycobacterium tuberculosis (Mtb). MDR-Mtb strains are resistant to first-line anti-TB drugs such as isoniazid and rifampicin; whereas XDR-Mtb strains are resistant to additional drugs including at least to any fluoroquinolone and one of the second-line anti-TB injectable drugs such as kanamycin, capreomycin, or amikacin. Clinically, these strains have significantly impacted the management of TB in high-incidence developing countries, where systemic surveillance of TB drug resistance is lacking. For effective management of TB on-site, early detection of drug resistance is critical to initiate treatment, to reduce mortality, and to thwart drug-resistant TB transmission. In this review, we discuss the diagnostic challenges to detect drug-resistant TB at the point-of-care (POC). Moreover, we present the latest advances in nano/microscale technologies that can potentially detect TB drug resistance to improve on-site patient care.


Assuntos
Antituberculosos/farmacologia , Tuberculose Extensivamente Resistente a Medicamentos/diagnóstico , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Antituberculosos/administração & dosagem , Diagnóstico Precoce , Tuberculose Extensivamente Resistente a Medicamentos/tratamento farmacológico , Tuberculose Extensivamente Resistente a Medicamentos/epidemiologia , Humanos , Microtecnologia/métodos , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/isolamento & purificação , Nanotecnologia/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Resistente a Múltiplos Medicamentos/epidemiologia
12.
Chem Sci ; 4(2): 655-663, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23991282

RESUMO

Solid-state nanopores have been widely employed in sensing applications from Coulter counters to DNA sequencing devices. The analytical signal in such experiments is the change in ionic current flowing through the orifice caused by the large molecule or nanoparticle translocation through the pore. Conceptually similar nanopipette-based sensors can offer several advantages including the ease of fabrication and small physical size essential for local measurements and experiments in small spaces. This paper describes the first evaluation of nanopipettes with well characterized geometry for resistive-pulse sensing of Au nanoparticles (AuNP), nanoparticles coated with an allergen epitope peptide layer, and AuNP-peptide particles with bound antipeanut antibodies (IgY) on the peptide layer. The label-free signal produced by IgY-conjugated particles was strikingly different from those obtained with other analytes, thus suggesting the possibility of selective and sensitive resistive-pulse sensing of antibodies.

13.
Expert Opin Med Diagn ; 5(5): 381-391, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22102846

RESUMO

IMPORTANCE OF THE FIELD: Devices for the reliable detection of panels of biomarker proteins facilitated by magnetic bead-based technologies have the potential to greatly improve future cancer diagnostics. The reason for this review is to highlight promising research on emerging procedures for protein capture, transport and detection featuring magnetic particles. AREAS COVERED IN THIS REVIEW: The review covers applications of magnetic particles in protein immunoassays in emerging research and commercial methods, and stresses multiplexed protein assays for reliable future cancer diagnostics. Research literature over the past dozen years has been surveyed and specific examples are presented in detail. EXPERT OPINION: Magnetic particles are important components of emerging protein detection systems. They need to be integrated into simple inexpensive systems for accurate, sensitive detection of fully validated panels of biomarker proteins to be widely useful in clinical cancer diagnostics.

14.
Biosens Bioelectron ; 26(11): 4477-83, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21632234

RESUMO

A microfluidic electrochemical immunoassay system for multiplexed detection of protein cancer biomarkers was fabricated using a molded polydimethylsiloxane channel and routine machined parts interfaced with a pump and sample injector. Using off-line capture of analytes by heavily-enzyme-labeled 1 µm superparamagnetic particle (MP)-antibody bioconjugates and capture antibodies attached to an 8-electrode measuring chip, simultaneous detection of cancer biomarker proteins prostate specific antigen (PSA) and interleukin-6 (IL-6) in serum was achieved at sub-pg mL⁻¹ levels. MPs were conjugated with ∼90,000 antibodies and ∼200,000 horseradish peroxidase (HRP) labels to provide efficient off-line capture and high sensitivity. Measuring electrodes feature a layer of 5 nm glutathione-decorated gold nanoparticles to attach antibodies that capture MP-analyte bioconjugates. Detection limits of 0.23 pg mL⁻¹ for PSA and 0.30 pg mL⁻¹ for IL-6 were obtained in diluted serum mixtures. PSA and IL-6 biomarkers were measured in serum of prostate cancer patients in total assay time 1.15 h and sensor array results gave excellent correlation with standard enzyme-linked immunosorbent assays (ELISA). These microfluidic immunosensors employing nanostructured surfaces and off-line analyte capture with heavily labeled paramagnetic particles hold great promise for accurate, sensitive multiplexed detection of diagnostic cancer biomarkers.


Assuntos
Biomarcadores Tumorais/sangue , Técnicas Biossensoriais/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/estatística & dados numéricos , Técnicas Eletroquímicas , Ensaio de Imunoadsorção Enzimática , Desenho de Equipamento , Feminino , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoensaio/estatística & dados numéricos , Interleucina-6/sangue , Nanopartículas de Magnetita , Masculino , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/estatística & dados numéricos , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue
15.
Chem Commun (Camb) ; 47(43): 11861-3, 2011 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-21975371

RESUMO

Layer-by-layer (LBL) assembly of alternate osmium redox polymers and glucose oxidase, at anode, and laccase, at cathode, using graphite electrodes form a membrane-less glucose/O(2) enzymatic fuel cell providing a power density of 103 µW cm(-2) at pH 5.5.


Assuntos
Glucose Oxidase/metabolismo , Grafite/química , Polímeros/química , Técnicas Eletroquímicas , Eletrodos , Glucose/metabolismo , Concentração de Íons de Hidrogênio , Oxirredução , Oxigênio/metabolismo
16.
Electroanalysis ; 21(9): 1005-1013, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23100998

RESUMO

Voltammetric sensors made with films of polyions, double-stranded DNA and liver microsomes adsorbed layer-by-layer onto pyrolytic graphite electrodes were evaluated for reactive metabolite screening. This approach features simple, inexpensive screening without enzyme purification for applications in drug or environmental chemical development. Cytochrome P450 enzymes (CYPs) in the liver microsomes were activated by an NADPH regenerating system or by electrolysis to metabolize model carcinogenic compounds nitrosamine and styrene. Reactive metabolites formed in the films were trapped as adducts with nucleobases on DNA. The DNA damage was detected by square-wave voltammetry (SWV) using [Formula: see text] as a DNA-oxidation catalyst. These sensors showed a larger rate of increase in signal vs. reaction time for a highly toxic nitrosamine than for the moderately toxic styrene due to more rapid reactive metabolite-DNA adduct formation. Results were consistent with reported in vivo TD(50) data for the formation of liver tumors in rats. Analogous polyion/ liver microsome films prepared on 500 nm silica nanoparticles (nanoreactors) and reacted with nitrosamine or styrene, provided LC-MS or GC analyses of metabolite formation rates that correlated well with sensor response.

17.
ACS Nano ; 3(3): 585-94, 2009 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-19216571

RESUMO

A densely packed gold nanoparticle platform combined with a multiple-enzyme labeled detection antibody-magnetic bead bioconjugate was used as the basis for an ultrasensitive electrochemical immunosensor to detect cancer biomarkers in serum. Sensitivity was greatly amplified by synthesizing magnetic bioconjugates particles containing 7500 horseradish peroxidase (HRP) labels along with detection antibodies (Ab2) attached to activated carboxyl groups on 1 microm diameter magnetic beads. These sensors had sensitivity of 31.5 microA mL ng(-1) and detection limit (DL) of 0.5 pg mL(-1) for prostate specific antigen (PSA) in 10 microL of undiluted serum. This represents an ultralow mass DL of 5 fg PSA, 8-fold better than a previously reported carbon nanotube (CNT) forest immunosensor featuring multiple labels on carbon nanotubes, and near or below the normal serum levels of most cancer biomarkers. Measurements of PSA in cell lysates and human serum of cancer patients gave excellent correlations with standard ELISA assays. These easily fabricated AuNP immunosensors show excellent promise for future fabrication of bioelectronic arrays.


Assuntos
Técnicas Biossensoriais/métodos , Ouro/química , Imunoensaio/métodos , Nanopartículas/química , Biomarcadores Tumorais , Técnicas Biossensoriais/instrumentação , Eletrodos , Peroxidase do Rábano Silvestre , Humanos , Imunoensaio/instrumentação , Magnetismo , Antígeno Prostático Específico/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA