Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anesth Analg ; 133(1): 151-159, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33835077

RESUMO

BACKGROUND: While flexible epidural catheters reduce the risk of paresthesia and intravascular cannulation, they may be more challenging to advance beyond the tip of a Tuohy needle. This may increase placement time, number of attempts, and possibly complications when establishing labor analgesia. This study investigated the ability to advance flexible epidural catheters through different epidural needles from 2 commonly used, commercially available, epidural kits. METHODS: We hypothesized that the multiorifice wire-reinforced polyamide nylon blend epidural catheters will have a higher rate of successful first attempt insertion than the single-end hole wire-reinforced polyurethane catheters for the establishment of labor analgesia. The primary outcome was a difference in proportions of failure to advance the epidural catheter between the 2 epidural kits and was tested by a χ2 test. Two-hundred forty epidural kits were collected (n = 120/group) for 240 laboring patients requesting epidural analgesia in this open-label clinical trial from November 2018 to September 2019. Two-week time intervals were randomized for the exclusive use of 1 of the 2 kits in this study, where all patients received labor analgesia through either the flexible epidural catheter "A" or the flexible epidural catheter "B." Engineering properties of the equipment used were then determined. RESULTS: Flexible epidural catheter "A," the single-end hole wire-reinforced polyurethane catheter, did not advance at the first attempt in 15% (n = 18 of 120) of the parturients compared to 0.8% (n = 1 of 120) of the catheter "B," the multiorifice wire-reinforced polyamide nylon blend epidural catheter (P < .0001). Twenty-five additional epidural needle manipulations were recorded in the laboring patients who received catheter "A," while 1 epidural needle manipulation was recorded in the parturients who received catheter "B" (P < .0001). Bending stiffness of the epidural catheters used from kit "B" was twice the bending stiffness of the catheters used from kit "A" (bending stiffness catheters "A" 0.64 ± 0.04 N·mm2 versus bending stiffness catheters "B" 1.28 ± 0.20 N·mm2, P = .0038), and the angle formed by the needle and the epidural catheter from kit "A" was less acute than the angle formed from kit "B" (kit "A" 14.17 ± 1.72° versus kit "B" 21.83 ± 1.33°, P = .0036), with a mean difference of 7.66° between the 2 kits' angles. CONCLUSIONS: The incidence of an inability to advance single-end hole wire-reinforced polyurethane catheter was higher compared to the use of multiorifice wire-reinforced polyamide nylon blend epidural catheter. Variation of morphological features of epidural needles and catheters may play a critical role in determining the successful establishment of labor epidural analgesia.


Assuntos
Analgesia Epidural/instrumentação , Analgésicos/administração & dosagem , Catéteres , Desenho de Equipamento/instrumentação , Trabalho de Parto/efeitos dos fármacos , Maleabilidade , Adulto , Analgesia Epidural/métodos , Desenho de Equipamento/métodos , Feminino , Humanos , Trabalho de Parto/fisiologia , Gravidez , Estudos Prospectivos
2.
Transfusion ; 59(7): 2234-2237, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31032969

RESUMO

BACKGROUND: Congenital factor V deficiency, also called parahemophilia, is a rare hematological disorder that can be treated with platelet transfusion. CASE PRESENTATION: A 27-year-old G2P0100 with factor V deficiency was admitted for induction of labor and requested labor epidural analgesia. Throughout her hospital course, factor V levels were managed per recommendation from her hematologist, which included transfusing fresh frozen plasma (FFP) to maintain a factor V level of 50% before any neuraxial technique and 40% for postpartum hemostasis. The parturient required multiple transfusions of FFP to stay at this level, which eventually resulted in pulmonary edema. Given the request to maintain high levels of factor V, the parturient was transfused with platelets as an alternative source of factor V. The parturient eventually delivered a healthy neonate without signs of postpartum hemorrhage or epidural hematoma. CONCLUSION: A major learning point from this case is that platelet transfusion is an effective alternative in the management of factor V deficiency. Factor V released by platelets has enhanced procoagulant function, resulting in local factor V concentrations 100 times more than that of plasma, and has a significantly extended half-life. Platelet transfusion should be considered as a therapy in treating parturients with factor V deficiency.


Assuntos
Deficiência do Fator V/complicações , Deficiência do Fator V/terapia , Transfusão de Plaquetas , Complicações Hematológicas na Gravidez/terapia , Adulto , Cesárea , Feminino , Humanos , Recém-Nascido , Trabalho de Parto Induzido , Plasma , Gravidez , Resultado da Gravidez , Edema Pulmonar/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA