Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Braz J Med Biol Res ; 40(3): 383-9, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17334536

RESUMO

The effect of proton pump inhibitors and Helicobacter pylori infection on the bioavailability of antibiotics is poorly understood. We determined the effects of 5-day oral administration of 60 mg lansoprazole on the bioavailability of clarithromycin in individuals with and without H. pylori infection. Thirteen H. pylori-infected and 10 non-infected healthy volunteers were enrolled in a study with an open-randomized two-period crossover design and a 21-day washout period between phases. Plasma concentrations of clarithromycin in subjects with and without lansoprazole pre-treatment were measured by liquid chromatography coupled to a tandem mass spectrometer. Clarithromycin Cmax and AUC0-10 h were significantly reduced after lansoprazole administration. In addition, lansoprazole treatment of the H. pylori-positive group resulted in a statistically significant greater reduction in Cmax (40 vs 15%) and AUC0-10 h (30 vs 10%) compared to lansoprazole-treated H. pylori-negative subjects. Thus, treatment with lansoprazole for 5 days reduced bioavailability of clarithromycin, irrespective of H. pylori status. This reduction, however, was even more pronounced in H. pylori-infected individuals.


Assuntos
2-Piridinilmetilsulfinilbenzimidazóis/administração & dosagem , Antibacterianos/farmacocinética , Antiulcerosos/administração & dosagem , Claritromicina/farmacocinética , Infecções por Helicobacter/tratamento farmacológico , Helicobacter pylori , Adulto , Antibacterianos/uso terapêutico , Área Sob a Curva , Disponibilidade Biológica , Estudos de Casos e Controles , Cromatografia Líquida de Alta Pressão , Claritromicina/uso terapêutico , Estudos Cross-Over , Sinergismo Farmacológico , Infecções por Helicobacter/metabolismo , Humanos , Lansoprazol , Inibidores da Bomba de Prótons , Fatores de Tempo
2.
J Mass Spectrom ; 40(9): 1197-202, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16127659

RESUMO

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.


Assuntos
Cromatografia Líquida de Alta Pressão , Antagonistas de Dopamina/sangue , Antagonistas de Dopamina/farmacocinética , Metoclopramida/análogos & derivados , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Metoclopramida/sangue , Metoclopramida/farmacocinética , Equivalência Terapêutica
3.
J Pharm Pharm Sci ; 8(2): 340-7, 2005 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-16124946

RESUMO

PURPOSE: A sensitive, robust, and selective liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) was developed and validated for paroxetine quantification in human EDTA plasma. METHODS: Sample preparation was based on liquid-liquid extraction using a mixture of ethyl acetate/hexane (50/50; v/v) to extract the drug and internal standard from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 1.6 and 1.7 for paroxetine and fluoxetine (IS), respectively. The ionization was optimized using ESI(+) and selectivity was achieved by tandem mass spectrometric analysis using MRM functions, 330.0 --> 70.0 and 310 --> 43.9 for paroxetine and fluoxetine. RESULTS: Analytical curve ranged from 0.2 to 20.0 ng/mL. Inter-day precision and accuracy of the quality control (QC) samples were < 15% relative standard deviation (RSD). Analyte stability during sampling processing and storage were established. CONCLUSION: Validation results on linearity, specificity, accuracy, precision as well as application to the analysis of samples taken up to 120 h after oral administration of 20 mg of paroxetine in 28 healthy volunteers were found to be of good performance in bioequivalence study.


Assuntos
Química Farmacêutica/métodos , Paroxetina/sangue , Adolescente , Adulto , Cromatografia Líquida/métodos , Estudos Cross-Over , Humanos , Masculino , Espectrometria de Massas/métodos , Paroxetina/química
4.
Braz J Med Biol Res ; 38(3): 437-44, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15761624

RESUMO

It has been suggested that the measurement of metronidazole clearance is a sensitive method for evaluating liver function. The aim of this study was to evaluate the usefulness of plasma hydroxy-metronidazole/metronidazole ratios as indicators of dynamic liver function to detect changes resulting from the various forms of chronic hepatitis C virus (HCV) infection. A total of 139 individuals were studied: 14 healthy volunteers, 22 healthy, asymptomatic, consecutive anti-HCV-positive HCV-RNA negative subjects, 81 patients with chronic hepatitis C (49 with moderate/severe chronic hepatitis and 34 with mild hepatitis), and 20 patients with cirrhosis of the liver. HCV status was determined by the polymerase chain reaction. Plasma concentrations of metronidazole and its hydroxy-metabolite were measured by reverse-phase high-performance liquid chromatography with ultraviolet detection in a blood sample collected 10 min after the end of a metronidazole infusion. Anti-HCV-positive HCV-RNA-negative individuals demonstrated a significantly reduced capacity to metabolize intravenously infused metronidazole compared to healthy individuals (0.0478 +/- 0.0044 vs 0.0742 +/- 0.0232). Liver cirrhosis patients also had a reduced plasma hydroxy-metronidazole/metronidazole ratio when compared to the other groups of anti-HCV-positive individuals (0.0300 +/- 0.0032 vs 0.0438 +/- 0.0027 (moderate/severe chronic hepatitis) vs 0.0455 +/- 0.0026 (mild chronic hepatitis) and vs 0.0478 +/- 0.0044 (anti-HCV-positive, HCV-RNA-negative individuals)). These results suggest an impairment of the metronidazole metabolizing system induced by HCV infection that lasts after viral clearance. In those patients with chronic hepatitis C, this impairment is paralleled by progression of the disease to liver cirrhosis.


Assuntos
Anti-Infecciosos , Hepacivirus/genética , Hepatite C Crônica/complicações , Cirrose Hepática/diagnóstico , Metronidazol , Adulto , Anti-Infecciosos/sangue , Biomarcadores/sangue , Estudos de Casos e Controles , Cromatografia Líquida de Alta Pressão , Feminino , Genótipo , Humanos , Cirrose Hepática/etiologia , Testes de Função Hepática , Masculino , Metronidazol/análogos & derivados , Metronidazol/sangue , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Índice de Gravidade de Doença , Carga Viral
5.
Aliment Pharmacol Ther ; 16(6): 1163-70, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12030960

RESUMO

BACKGROUND: The effects of proton pump inhibitors and Helicobacter pylori infection on the distribution of drugs used for the eradication of the bacteria are poorly understood. AIM: The aim of this study was to investigate the effects of a 7-day administration of 20 mg of omeprazole on the pharmacokinetics of amoxicillin and ampicillin in the plasma, saliva and gastric juice of individuals with and without H. pylori infection. METHODS: Fifty-four healthy volunteers without endoscopic lesions were enrolled. Twenty-six volunteers were included in the amoxicillin study and 28 individuals in the ampicillin study. Each study had an open randomized two-period crossover design and a 21-day washout period between phases. Plasma, saliva and gastric juice concentrations of amoxicillin and ampicillin in subjects with and without omeprazole pre-treatment were measured by reversed-phase HPLC using UV detection. RESULTS: Neither pre-treatment with omeprazole nor H. pylori infection interfered with the plasma bioavailability of amoxicillin or ampicillin, as assessed by the AUC0-2 h. Neither ampicillin nor amoxicillin were detected in saliva or gastric juice in any study phase. CONCLUSION: Short-term treatment with omeprazole does not interfere with the pharmacokinetics of amoxicillin or ampicillin. Our results also exclude the presence of a transfer mechanism for amoxicillin or ampicillin from the plasma to the gastric lumen.


Assuntos
Amoxicilina/farmacocinética , Ampicilina/farmacocinética , Inibidores Enzimáticos/farmacologia , Infecções por Helicobacter/tratamento farmacológico , Helicobacter pylori/patogenicidade , Omeprazol/farmacologia , Penicilinas/farmacocinética , Inibidores da Bomba de Prótons , Adulto , Amoxicilina/administração & dosagem , Ampicilina/administração & dosagem , Área Sob a Curva , Disponibilidade Biológica , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Feminino , Suco Gástrico/química , Humanos , Masculino , Penicilinas/administração & dosagem , Saliva/química
6.
Anal Bioanal Chem ; 382(4): 1049-54, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15891869

RESUMO

A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for quantifying amlodipine in human plasma was developed and validated. Sample preparation was based on liquid-liquid extraction using NaOH and a mixture of ethyl acetate/hexane (80/20; v/v). Chromatography was performed on a C-18 analytical column and the retention times were 1.9 and 3.0 min for amlodipine and nimodipine (internal standard), respectively. The ionization was optimized using ESI(+) and enhanced selectivity was achieved using tandem mass spectrometric analysis via two MRM functions, 409 --> 238 and 418 --> 343 for amlodipine and nimodipine. The calibration curve ranged from 0.2 to 20.0 ng/mL. The inter-day precision and accuracy and the relative standard deviation (RSD) were <15%. The analyte was shown to be stable over the time-scale of the whole procedure. The robustness of the method was demonstrated by the good reproducibility of the results obtained during the analysis of clinical samples.


Assuntos
Anlodipino/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Humanos , Estrutura Molecular , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação
7.
Helicobacter ; 7(1): 53-9, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11886474

RESUMO

OBJECTIVE: To evaluate the efficacy of two commonly employed treatments for Helicobacter pylori infection and the impact of bacterial resistance to antibiotics on eradication rate. METHODS: Ninety-two consecutive H. pylori-positive patients with active peptic ulcer disease were randomly enrolled to receive a 7-day treatment with either lansoprazole 30 mg plus amoxicillin 1 g and clarithromycin 500 mg [all twice a day (b.i.d.), Group A, n = 46]; or bismuth subcitrate 125 mg four times a day (q.i.d.) plus tetracycline 500 mg q.i.d and furazolidone 200 mg b.i.d. (Group B, n = 46) H. pylori status was reassessed 30 days after completion of the therapy and bacterial resistance to the antibiotics was investigated using an in vitro assay. RESULTS: Five patients from each study group were lost to follow up. Both treatments resulted in similar H. pylori eradication rate: 66-60% (per protocol), 59-52% (intention-to-treat) in Groups A and B, respectively (non significant). However, eradication improved to 79% in the absence of H. pylori resistance to clarithromycin or amoxicillin. CONCLUSION: Primary resistance to clarithromycin or amoxicillin may underscore a potentially serious problem for the eradication of H. pylori infection. Testing for bacterial resistance may become necessary to improve therapeutic efficacy.


Assuntos
Antibacterianos/farmacologia , Farmacorresistência Bacteriana , Infecções por Helicobacter/tratamento farmacológico , Helicobacter pylori/efeitos dos fármacos , Úlcera Péptica/tratamento farmacológico , Adulto , Idoso , Antibacterianos/uso terapêutico , Quimioterapia Combinada , Feminino , Infecções por Helicobacter/microbiologia , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Úlcera Péptica/microbiologia , Falha de Tratamento
8.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;40(3): 383-389, Mar. 2007. tab
Artigo em Inglês | LILACS | ID: lil-441763

RESUMO

The effect of proton pump inhibitors and Helicobacter pylori infection on the bioavailability of antibiotics is poorly understood. We determined the effects of 5-day oral administration of 60 mg lansoprazole on the bioavailability of clarithromycin in individuals with and without H. pylori infection. Thirteen H. pylori-infected and 10 non-infected healthy volunteers were enrolled in a study with an open-randomized two-period crossover design and a 21-day washout period between phases. Plasma concentrations of clarithromycin in subjects with and without lansoprazole pre-treatment were measured by liquid chromatography coupled to a tandem mass spectrometer. Clarithromycin Cmax and AUC0-10 h were significantly reduced after lansoprazole administration. In addition, lansoprazole treatment of the H. pylori-positive group resulted in a statistically significant greater reduction in Cmax (40 vs 15 percent) and AUC0-10 h (30 vs 10 percent) compared to lansoprazole-treated H. pylori-negative subjects. Thus, treatment with lansoprazole for 5 days reduced bioavailability of clarithromycin, irrespective of H. pylori status. This reduction, however, was even more pronounced in H. pylori-infected individuals.


Assuntos
Humanos , Adulto , Antibacterianos/farmacocinética , Antiulcerosos/administração & dosagem , Claritromicina/farmacocinética , Helicobacter pylori , Infecções por Helicobacter/tratamento farmacológico , /administração & dosagem , Antibacterianos/uso terapêutico , Disponibilidade Biológica , Estudos de Casos e Controles , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Claritromicina/uso terapêutico , Sinergismo Farmacológico , Bombas de Próton/antagonistas & inibidores , Fatores de Tempo
9.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;38(3): 437-444, mar. 2005. tab
Artigo em Inglês | LILACS | ID: lil-394792

RESUMO

It has been suggested that the measurement of metronidazole clearance is a sensitive method for evaluating liver function. The aim of this study was to evaluate the usefulness of plasma hydroxy-metronidazole/metronidazole ratios as indicators of dynamic liver function to detect changes resulting from the various forms of chronic hepatitis C virus (HCV) infection. A total of 139 individuals were studied: 14 healthy volunteers, 22 healthy, asymptomatic, consecutive anti-HCV-positive HCV-RNA negative subjects, 81 patients with chronic hepatitis C (49 with moderate/severe chronic hepatitis and 34 with mild hepatitis), and 20 patients with cirrhosis of the liver. HCV status was determined by the polymerase chain reaction. Plasma concentrations of metronidazole and its hydroxy-metabolite were measured by reverse-phase high-performance liquid chromatography with ultraviolet detection in a blood sample collected 10 min after the end of a metronidazole infusion. Anti-HCV-positive HCV-RNA-negative individuals demonstrated a significantly reduced capacity to metabolize intravenously infused metronidazole compared to healthy individuals (0.0478 ± 0.0044 vs 0.0742 ± 0.0232). Liver cirrhosis patients also had a reduced plasma hydroxy-metronidazole/metronidazole ratio when compared to the other groups of anti-HCV-positive individuals (0.0300 ± 0.0032 vs 0.0438 ± 0.0027 (moderate/severe chronic hepatitis) vs 0.0455 ± 0.0026 (mild chronic hepatitis) and vs 0.0478 ± 0.0044 (anti-HCV-positive, HCV-RNA-negative individuals)). These results suggest an impairment of the metronidazole metabolizing system induced by HCV infection that lasts after viral clearance. In those patients with chronic hepatitis C, this impairment is paralleled by progression of the disease to liver cirrhosis.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anti-Infecciosos , Hepacivirus/genética , Hepatite C Crônica/complicações , Cirrose Hepática/diagnóstico , Metronidazol , Anti-Infecciosos/sangue , Biomarcadores/sangue , Estudos de Casos e Controles , Cromatografia Líquida de Alta Pressão , Genótipo , Testes de Função Hepática , Cirrose Hepática/etiologia , Metronidazol/análogos & derivados , Metronidazol/sangue , Reação em Cadeia da Polimerase , Índice de Gravidade de Doença , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA