Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 98(6): e14341, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30732160

RESUMO

To evaluate iterative metal artifact reduction (iMAR) technique in images data of hip prosthesis on computed tomography (CT) and the added value of advanced modeled iterative reconstruction (ADMIRE) compared with standard filtered back projection (FBP).Twenty-eight patients addressed to CT examinations for hip prosthesis were included prospectively. Images were reconstructed with iMAR algorithm in addition to FBP and ADMIRE techniques. Measuring image noise assessed objective image quality and attenuation values with standardized region of interest (ROI) in 4 predefined anatomical structures (gluteus medius and rectus femoris muscles, inferior and anterior abdominal fat, and femoral vessels when contrast media was present). Subjective image quality was graded on a 5-point Likert scale, taking into account the size of artifacts, the metal-bone interface and the conspicuity of pelvic organs, and the diagnostic confidence.Improvement in overall image quality was statistically significant using iMAR (P<.001) compared with ADMIRE and FBP. ADMIRE did not show any impact in image noise, attenuation value, or global quality image. iMAR showed a significant decrease in image noise in all ROIs (Hounsfield Unit) as compared with FBP and ADMIRE. Interobserver agreement was high in all reconstructions (FBP, FBP+iMAR, ADMIRE, and ADMIRE + iMAR) more than 0.8. iMAR reconstructions showed emergence of new artifacts in bone-metal interface.iMAR algorithm allows a significant reduction of metal artifacts on CT images with unilateral or bilateral prostheses without additional value of ADMIRE. It improves the analysis of surrounding tissue but potentially generates new artifacts in bone-metal interface.


Assuntos
Prótese de Quadril , Pelve/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Gordura Abdominal/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral/diagnóstico por imagem , Veia Femoral/diagnóstico por imagem , Humanos , Masculino , Músculo Esquelético/diagnóstico por imagem , Suíça
2.
Clin Neuroradiol ; 29(4): 741-749, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29922902

RESUMO

PURPOSE: To investigate the impact of iterative metal artifact reduction (iMAR) on artifacts related to neurosurgical clips or endovascular coils when combined to filtered back projection (FBP) or advanced modelled iterative reconstruction (ADMIRE). MATERIAL AND METHODS: In this study 21 unenhanced brain computed tomography (CT) examinations were reconstructed with FBP and level 2 of ADMIRE, both techniques with and without iMAR algorithm, resulting in 4 series per acquisition. Subjective assessment of artifact reduction was performed as a double-blinded evaluation with a 5-point-scale. Objective analysis was performed by comparing central tendencies and distributions of voxel densities. The central tendency was assessed as the mean voxel density in Hounsfield units. The distribution was assessed by evaluating the shape and asymmetry of the histograms of voxels densities with measures of kurtosis and skewness, respectively. RESULTS: Inter-reader agreement was excellent (>0.8). FBP and ADMIRE without iMAR were scored 4 and with iMAR 5. Unusual artifacts were noted in all of the series reconstructed with iMAR, especially when combined with ADMIRE. Kurtosis revealed statistical differences for all reconstruction techniques (p ≤ 0.0007) except for the association of FBP with iMAR (p = 0.2211) for the coiling population and skewness demonstrated no statistical difference in any population (p ≥ 0.0558), confirming the subjective analysis results, except for the ADMIRE algorithm with or without iMAR (p ≤ 0.0342) in the coiling population. CONCLUSION: iMAR led to the reduction in artifacts due to intracranial metallic devices. However, it created a new artifact in the form of a halo of photon-starvation, especially when combined with ADMIRE. The combination of FBP and iMAR seems more suitable, combining the beneficial metal artifact reduction without the emergence of a halo of photon starvation just around the point of interest.


Assuntos
Algoritmos , Artefatos , Aneurisma Intracraniano/diagnóstico por imagem , Adulto , Idoso , Método Duplo-Cego , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/cirurgia , Masculino , Metais , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/instrumentação , Cuidados Pós-Operatórios/métodos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos