Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 86(2): 278-86, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25708850

RESUMO

OBJECTIVES: To assess the safety and effectiveness of the Stellarex™ drug-coated angioplasty balloon (DCB) to inhibit restenosis in the superficial femoral and/or popliteal artery. BACKGROUND: Treatment of peripheral arterial disease is challenged by restenosis, requiring revascularization procedures to maintain patency. DCBs are designed to deliver an anti-proliferative drug to the vessel wall to diminish smooth muscle cell proliferation and maintain patency. METHODS: This prospective, single-arm, multicenter study enrolled 50 patients with 58 lesions in the first cohort that required pre-dilatation with an uncoated angioplasty balloon prior to inflation of the DCB. The primary effectiveness endpoint was 6-month late lumen loss (LLL). The major secondary endpoint was major adverse event (MAE) rate at 6 months, defined as cardiovascular death, amputation, and/or ischemia-driven target lesion revascularization. RESULTS: The mean lesion length was 7.2 cm and baseline stenosis was 75.1%. Calcification was present in 62.1% of lesions and 12.1% were occluded. Both endpoints met their prespecified performance goals; at 6 months, the MAE rate was 4% and the mean LLL was 0.54 mm. The primary patency rate was 89.5% at 12 months and 80.3% at 24 months. The freedom from clinically-driven target lesion revascularization rate, per Kaplan-Meier estimate, was 90.0% at 12 months and 85.8% at 24 months. Additionally, there were no amputations or cardiovascular deaths reported through 24 months. CONCLUSIONS: The Stellarex DCB provides safe and durable clinical outcomes for treatment of femoropopliteal artery disease through 24 months.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Intervalo Livre de Doença , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA