RESUMO
BACKGROUND: Small-for-gestational-age (SGA) children have increased cardiovascular risk, but the mediating factors are poorly understood. We hypothesized that birth size could affect the cardiovascular system since childhood in the absence of other risk factors. We investigated endothelial and myocardial function in SGA children with regular catch-up growth. METHODSâANDâRESULTS: Biochemical markers, blood pressure, flow-mediated vasodilation (FMD), common carotid intima-media thickness (cIMT), anteroposterior diameter of the infrarenal abdominal aorta (APAO) and echocardiographic parameters of left and right ventricular (LV and RV) function were studied in 27 SGA and 25 appropriate-for-gestational-age (AGA) subjects. SGA subjects had a higher homeostasis model assessment index than controls (2.61±1.27 vs. 1.56±0.40, P=0.01), higher cIMT (0.51±0.04 mm vs. 0.45±0.07 mm, P=0.007) and APAO (1.31±1.35 cm vs. 1.30±0.16 cm, P=0.005), and lower FMD (10.11±4.17% vs. 12.34±4.28, P=0.04) than controls. On echocardiography SGA had higher Tei index both at LV and RV than controls (P=0.001). Reduced RV systolic function was also observed in SGA subjects. CONCLUSIONS: SGA subjects had vascular morphological and function abnormalities compared with AGA, which increase their cardiovascular risk profile. Furthermore, a subtle cardiac alteration in both RV and LV functions was seen in SGA patients compared with AGA.
Assuntos
Pressão Sanguínea , Espessura Intima-Media Carotídea , Ecocardiografia , Recém-Nascido Pequeno para a Idade Gestacional/crescimento & desenvolvimento , Miocárdio , Função Ventricular Esquerda , Função Ventricular Direita , Adolescente , Criança , Feminino , Seguimentos , Humanos , MasculinoRESUMO
AIM: Transcatheter closure of an ostium secundum atrial septal defect (ASD) is now considered the standard care for most of children with the appropriate anatomy, and is a relatively well-tolerated procedure to reduce the clinical sequelae of ASD, with a low complication rate. METHODS: The present case reports describe our clinical experience of the percutaneous closure of a secundum ASD in 10 children between December 2011 and November 2012, by means of a new generation of device, the GORE Septal Occluder device. RESULTS: The implantation was successful in all except two cases, the device being properly placed and deployed without malposition or embolization in the catheterization laboratory. No complications were related to the procedure. The successful implant was confirmed and no major adverse events were documented in the following 3-12 months. CONCLUSION: The new GORE Septal Occluder device appears to be a feasible, well-tolerated and successful tool for the closure of an ASD of 15âmm or less in childhood.