Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sol Phys ; 292(2): 26, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-32269392

RESUMO

Magnetoacoustic gravity (MAG) waves have been studied for some time. In this article, we investigate the effect that a shear flow at a tangential discontinuity embedded in a gravitationally stratified and magnetised plasma has on MAG surface waves. The dispersion relation found is algebraically analogous to the relation of the non-flow cases obtained by Miles and Roberts (Solar Phys. 141, 205, 1992), except for the introduction of a Doppler-shifted frequency for the eigenvalue. This feature, however, introduces rather interesting physics, including the asymmetric presence of forward- and backward-propagating surface waves. We find that increasing the equilibrium flow speed leads to a shift in the permitted regions of propagation for surface waves. For most wave number combinations this leads to the fast mode being completely removed, as well as more limited phase speed regimes for slow-mode propagation. We also find that upon increasing the flow, the phase speeds of the backward propagating waves are increased. Eventually, at high enough flow speeds, the wave's direction of propagation is reversed and is in the positive direction. However, the phase speed of the forward-propagating wave remains mainly the same. For strong enough flows we find that the Kelvin-Helmholtz instability can also occur when the forward- and backward-propagating modes couple.

2.
J Hosp Infect ; 114: 117-125, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33930487

RESUMO

BACKGROUND: Healthcare workers (HCWs) are at the front line of the ongoing coronavirus 2019 (COVID-19) pandemic. Comprehensive evaluation of the seroprevalence of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) among HCWs in a large healthcare system could help to identify the impact of epidemiological factors and the presence of symptoms on the immune response to the infection over time. AIM: To determine the seroprevalence of SARS-CoV-2-specific antibodies among HCWs, identify associated epidemiological factors and study antibody kinetics. METHODS: A longitudinal evaluation of the seroprevalence and epidemiology of SARS-CoV-2-specific antibodies was undertaken in approximately 30,000 HCWs in the largest healthcare system in Connecticut, USA. FINDINGS: At baseline, the prevalence of SARS-CoV-2 antibody among 6863 HCWs was 6.3% [95% confidence interval (CI) 5.7-6.9%], and was highest among patient care support (16.7%), medical assistants (9.1%) and nurses (8.2%), and lower for physicians (3.8%) and advanced practice providers (4.5%). Seroprevalence was significantly higher among African Americans [odds ratio (OR) 3.26 compared with Caucasians, 95% CI 1.77-5.99], in participants with at least one symptom of COVID-19 (OR 3.00, 95% CI 1.92-4.68), and in those reporting prior quarantine (OR 3.83, 95% CI 2.57-5.70). No symptoms were reported in 24% of seropositive participants. Among the 47% of participants who returned for a follow-up serological test, the seroreversion rate was 39.5% and the seroconversion rate was 2.2%. The incidence of re-infection in the seropositive group was zero. CONCLUSION: Although there is a decline in the immunoglobulin G antibody signal over time, 60.5% of seropositive HCWs had maintained their seroconversion status after a median of 5.5 months.


Assuntos
Anticorpos Antivirais/sangue , COVID-19 , SARS-CoV-2 , Adulto , COVID-19/imunologia , Connecticut/epidemiologia , Feminino , Pessoal de Saúde , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/imunologia , Estudos Soroepidemiológicos
4.
Am J Cardiol ; 82(4): 520-3, 1998 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-9723645

RESUMO

In 66 patients unable to exercise referred for pharmacologic stress single-photon emission computed tomographic myocardial perfusion imaging, a moderate dose of dobutamine was combined with intravenous dipyridamole and the results were compared with standard intravenous dipyridamole stress. The combined stress protocol resulted in increased defect size and reversibility with technetium-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging.


Assuntos
Cardiotônicos , Vasos Coronários/diagnóstico por imagem , Dipiridamol , Dobutamina , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Vasodilatadores , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
5.
Am J Cardiol ; 85(6): 680-4, 2000 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-12000040

RESUMO

Although the combined assessment of perfusion and function using rest electrocardiographic (ECG)-gated technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) imaging has been shown to improve sensitivity and accuracy over perfusion alone in the prediction of myocardial viability, no data are available comparing this technique with rest-redistribution thallium-201. Thirty patients with coronary artery disease and left ventricular dysfunction (ejection fraction < or = 40%) underwent rest-redistribution thallium-201 and rest ECG-gated Tc-99m sestamibi SPECT imaging before revascularization and rest ECG-gated Tc-99m sestamibi SPECT imaging at 1 or 6 weeks after revascularization. All thallium-201 and Tc-99m sestamibi images were interpreted by a consensus agreement of 3 experienced readers without knowledge of patient identity or time of imaging with Tc-99m sestamibi (before or after revascularization) using a 17-segment model. Concordance between techniques for the prediction of viability was 89% (kappa 0.556 +/- 0.109). With rest-redistribution thallium-201, sensitivity, specificity, positive predictive value, negative predictive value, and predictive accuracy were 95%, 59%, 88%, 78%, and 86%, respectively. With rest ECG-gated Tc-99m sestamibi SPECT imaging, sensitivity, specificity, positive predictive value, negative predictive value, and predictive accuracy were 96%, 55%, 87%, 80%, and 86%, respectively (p = NS vs rest-redistribution thallium-201). Although both techniques are comparable for detecting viable myocardium, rest ECG-gated Tc-99m sestamibi SPECT imaging allows direct assessment of both myocardial perfusion and ventricular function, which may be clinically useful in patients who require assessment of myocardial viability.


Assuntos
Eletrocardiografia , Miocárdio Atordoado/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Doença das Coronárias/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/diagnóstico por imagem
6.
Am J Cardiol ; 84(4): 400-3, 1999 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-10468076

RESUMO

Limited exercise combined with dipyridamole increases myocardial perfusion defect severity compared with dipyridamole alone. The impact of limited exercise combined with adenosine on myocardial perfusion defect severity is unknown. This study compares myocardial perfusion defect severity with adenosine alone and adenosine combined with limited exercise. Thirty-two patients with coronary artery disease underwent on separate days and in randomized order technetium-99m sestamibi (25 to 30 mCi) single-photon emission computed tomographic imaging at rest, after adenosine (140 microg/kg/min x 6 minutes), and after adenosine (140 microg/kg/min x 4 minutes) during 6 minutes of modified Bruce treadmill exercise (adenosine-exercise). Radiopharmaceutical was injected at 3 and 5 minutes during adenosine and adenosine-exercise, respectively. Images were interpreted by a consensus agreement of 3 nuclear cardiologists without knowledge of patient identity, stress protocol, or clinical data using a 17-segment model and 5-point scoring system. A summed stress score (SSS), summed rest score (SRS), and summed difference (SSS-SRS) score (SDS) were calculated for each image. Peak stress heart rate and rate-pressure product were higher for adenosine-exercise than adenosine (102 +/- 19 vs 81 +/- 11 beats/min and 13,972 +/- 4,265 vs 10,623 +/- 2,131, respectively; both p <0.001). Sensitivity for detection of > or = 50% coronary stenosis was 75% and 72% for adenosine-exercise and adenosine, respectively (p = NS). There were no differences in SSS and SDS between adenosine-exercise and adenosine (8.2 +/- 5.9 vs 8.1 +/- 6.3 and 4.9 +/- 4.1 vs 5.2 +/- 4.6, respectively; both p = NS). Thus, in patients with coronary artery disease, limited treadmill exercise combined with adenosine does not increase myocardial perfusion defect severity compared with standard adenosine technetium-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging.


Assuntos
Adenosina , Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Exercício Físico , Coração/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adenosina/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Doença das Coronárias/fisiopatologia , Eletrocardiografia , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Índice de Gravidade de Doença , Tecnécio Tc 99m Sestamibi/administração & dosagem
7.
Dev Comp Immunol ; 19(4): 337-46, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8617404

RESUMO

Monoclonal antibody (MAb) BLT-1, an IgG2a with kappa light chains, reacted strongly with 21% of bovine thymocytes, weakly with 15% of thymocytes, with a subpopulation of peripheral blood B cells that also expressed CD20 and with peripheral blood T cells. Practically all of the reactive thymocytes were of a large cell subpopulation. By immunoprecipitation, BLT-1 was shown to recognize a membrane molecule with a molecular mass of 67 kDa. In competitive assays for lymphocyte surface binding, BLT-1 and MAb CC-29 (which had been shown previously to react with bovine CD5) blocked one another, indicating that the epitopes recognized were identical or extensively overlapping. In contrast, another CD-5-reactive MAb, CC-17, did not block BLT-1 reactivity with lymphocytes although the reactivity of CC-17 was blocked by BLT-1, suggesting partial overlap of the epitopes or steric hindrance by BLT-1 but not by CC-17. BLT-1 was able to induce proliferation of bovine lymphocytes in culture alone if monocytes were present or in the absence of monocytes synergized with PMA. The results indicate that BLT-1 recognizes an epitope of the bovine homologue of CD5 and that perturbation of the epitope by MAb binding results in signal transduction to bovine lymphocytes.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/farmacologia , Especificidade de Anticorpos , Subpopulações de Linfócitos B/imunologia , Antígenos CD5/imunologia , Ativação Linfocitária , Subpopulações de Linfócitos T/imunologia , Animais , Ligação Competitiva/imunologia , Bovinos , Células Cultivadas , Sinergismo Farmacológico , Ionomicina/farmacologia , Ativação Linfocitária/efeitos dos fármacos , Acetato de Tetradecanoilforbol/farmacologia
8.
Vet Immunol Immunopathol ; 18(3): 279-85, 1988 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3260700

RESUMO

Direct immunofluorescence (IF) and indirect IF techniques were employed to analyze the distribution of B and T lymphocyte populations in peripheral blood, and in supramammary (draining), and prescapular (non-draining) lymph nodes of cows with mastitis and normal cows. In the peripheral blood there was a significant decrease in the percent and absolute number of B lymphocytes in mastitic cows (n = 29; 17.1 +/- 10.2%; 3.4 +/- 2.7 X 10(5) cells/ml) as compared to normal cows (n = 38; 25.2 +/- 7.8%; 9.3 +/- 5.4 X 10(5) cells/ml). The percent T lymphocyte count in mastitic cows (71.2 +/- 7.1%) was slightly increased over that of normals (65.8 +/- 7.2%), although the absolute number of T lymphocytes was decreased in mastitic cows (1.49 +/- 0.91 X 10(6) cells/ml vs. 2.47 +/- 1.28 X 10(6) cells/ml). In the prescapular lymph node the percent of B lymphocytes, but not T or "null lymphocytes", decreased significantly in mastitic cows as compared to that of normals. The decrease, i.e. 32%, paralleled the 32.1% decrease found in peripheral blood B lymphocytes. In contrast, in the supramammary lymph node of mastitic cows, the percent B lymphocytes increased over that of normals (35.1 +/- 2.0% vs. 20.4 +/- 9.4%), whereas the percent T lymphocytes decreased to 54.5 +/- 2.8% compared to 70.7 +/- 3.5% in normal cows. There was no significant change in percent "null lymphocytes". The weight of prescapular lymph nodes did not change in mastitic cows when compared to that of normals. As a result, the estimated number of B lymphocytes, but not of T and "null lymphocytes", decreased.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Linfócitos/classificação , Mastite Bovina/patologia , Animais , Linfócitos B/patologia , Bovinos , Feminino , Contagem de Leucócitos , Linfonodos/imunologia , Linfonodos/patologia , Linfócitos/citologia , Linfócitos/imunologia , Linfócitos Nulos/patologia , Mastite Bovina/sangue , Mastite Bovina/imunologia , Linfócitos T/patologia
9.
J Nucl Cardiol ; 6(3): 257-69, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10385181

RESUMO

BACKGROUND: Observer variability has been shown with interpretation of planar thallium-201 images. The interpretive reproducibility of technetium-99m sestamibi tomographic imaging is unknown. This study evaluated the interpretive reproducibility of interpretable Tc-99m sestamibi tomographic images among nuclear cardiologists with a wide range of training and experience. METHODS: Three experienced readers (EX) and 3 less-experienced readers (LEX) interpreted 138 exercise and rest Tc-99m sestamibi tomographic images (101 were abnormal in patients with coronary artery disease [CAD], 37 were normal in patients with <5% likelihood of CAD) twice in random sequence without clinical data. Images of good to excellent quality were randomly selected from a database at 2 nuclear cardiology laboratories. Intraobserver and interobserver agreement for global, left anterior descending (LAD) territory, non-LAD first (normal/abnormal) and second (normal/fixed/reversible) order, and defect extent (normal/single-vessel CAD/multi-vessel CAD) were assessed with percent agreement and Cohen's kappa (kappa) statistic. RESULTS: With regard to intraobserver agreement, first and second order ranged from 87% to 94% and 80% to 90% for global, 82% to 96% and 78% to 95% for LAD, and 88% to 91% and 80% to 90% for non-LAD, respectively. Defect extent ranged from 75% to 90%. There were no differences between EX and LEX for global and non-LAD first and second order, LAD first order, and defect extent. LAD second order was 93% for EX compared with 88% (P = .015) for LEX. With regard to interobserver agreement, first and second order ranged from 73% to 89% and 64% to 85% for global, 73% to 93% and 69% to 91% for LAD, and 76% to 88% and 68% to 84% for non-LAD, respectively. Defect extent ranged from 61% to 82%. Global first and second order ranged from 85% to 87% and 78% to 82% for EX compared with 73% to 84% and 64% to 79% for LEX. LAD first and second order ranged from 89% to 91% and 88% to 89% for EX compared with 73% to 91% and 69% to 70% for LEX. Non-LAD first and second order ranged from 82% to 86% and 76% to 77% for EX compared with 76% to 86% and 68% to 81% for LEX. Defect extent ranged from 69% to 75% for EX compared with 59% to 77% for LEX. CONCLUSIONS: There is moderate to excellent interpretive reproducibility with stress Tc-99m sestamibi SPECT imaging among nuclear cardiologists with a wide range of training and experience.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Circulação Coronária , Interpretação Estatística de Dados , Teste de Esforço , Humanos , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA