Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(2): 328-340, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105441

RESUMO

INTRODUCTION: The aim of the current study was to elucidated the reliable atrial fibrillation (AF) drivers identified by CARTOFINDER using OctaRay catheter. METHODS AND RESULTS: The reliability of focal and rotational activations identified by CARTOFINDER using OctaRay catheter was assessed by the sequential recordings in each site of both atrium before and after pulmonary vein isolation (PVI) in 10 persistent AF patients. The outcome measures were the reproducibility rate during the sequential recordings and the stability rate between pre- and post-PVI as reliable focal and rotational activations. The study results were compared with those under use of PentaRay catheter (N = 18). Total 68928 points of 360 sites in OctaRay group and 24 177 points of 311 sites in PentaRay were assessed. More focal activation sites were identified in OctaRay group than PentaRay group (7.9% vs. 5.7%, p < .001), although the reproducibility rate and the stability rate were significantly lower in OctaRay group (45.3% vs. 58.9%, p < .001; 11.2% vs. 28.4%, p < .001). Meanwhile, the prevalence of reproducible focal activation sites among overall points was comparable (3.6% vs. 3.3%, p = .08). Regarding rotational activation, more rotational activation sites were identified in OctaRay group (5.1% vs. 0.2%, p < .001), and the reproducibility rate and the stability rate were significantly higher in OctaRay group (45.2% and 12.5% vs. 0.0%, p < .001). Both reliable focal and rotational activation sites were characterized by significantly shorter AF-cycle length (CL) and higher repetition of focal and rotational activations during the recordings compared with the sites of non or unreliable focal and rotational activations. CONCLUSION: In CARTOFINDER, OctaRay catheter could identify reliable focal activation with high resolution and reliable rotational activation compared with PentaRay catheter. The repetitive focal and rotational activations with short AF-CL could be the potential target during ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Frequência Cardíaca , Reprodutibilidade dos Testes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Catéteres , Veias Pulmonares/cirurgia , Resultado do Tratamento
2.
PLoS One ; 19(1): e0297263, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38271400

RESUMO

OBJECTIVE: The frozen lesion formation created by cryoballoon ablation, especially with non-occluded applications, has not been fully evaluated. This study aimed to validate the lesion size under different cryoballoon ablation settings: application duration, push-up technique, and laminar flow. METHODS: The frozen lesion size was evaluated immediately after ending the freezing with three different application durations (120, 150, and 180 seconds) in porcine hearts (N = 24). During the application, the push-up technique was applied at 10, 20, and 30 seconds after starting the freezing with or without laminar flow. RESULTS: The lesion size was significantly correlated with the nadir balloon temperature (P<0.001). The lesion volume became significantly larger after 150 seconds than 120 seconds (1272mm3 versus 1709mm3, P = 0.004), but not after 150 seconds (versus 1876mm3 at 180 seconds, P = 0.29) with a comparable nadir balloon temperature. Furthermore, the lesion volume became significantly larger with the push-up technique with the largest lesion size with a 20-second push-up after the freezing (1193mm3 without the push-up technique versus 1585mm3 with a push-up at 10 seconds versus 1808mm3 with a push-up at 20 seconds versus 1714mm3 with a push-up at 30 seconds, P = 0.04). Further, the absence of laminar flow was not associated with larger lesion size despite a significantly lower nadir balloon temperature. CONCLUSION: The frozen lesion size created by cryoballoon ablation became larger with longer applications at least 150 seconds and with a push-up technique especially at 20 seconds after the freezing.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Animais , Suínos , Congelamento , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Criocirurgia/métodos , Temperatura , Fibrilação Atrial/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA