Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ J ; 88(4): 492-500, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37558458

RESUMO

BACKGROUND: Extracellular volume fraction (ECV) on magnetic resonance imaging can predict prognosis after aortic valve replacement in patients with aortic stenosis (AS). However, the usefulness of ECV on computed tomography (CT) for patients who have undergone transcatheter aortic valve replacement (TAVR) is unclear, so we investigated whether ECV analysis on CT is associated with clinical outcomes in TAVR candidates.Methods and Results: We analyzed 127 patients with severe AS who underwent preoperative CT for TAVR. We evaluated the utility of ECV analysis on single-energy CT for predicting patient prognosis after TAVR. The primary outcome was a composite of all-cause death and hospitalization due to heart failure (HF) after TAVR. 15 patients (12%) had composite outcomes: 4 deaths and 11 hospitalizations due to HF. In multivariate survival analysis using the Cox proportional hazard model, atrial fibrillation (AF) (hazard ratio (HR), 7.86; 95% confidence interval (CI), 2.57-24.03; P<0.001), history of congestive HF (HR, 4.91; 95% CI, 1.49-16.2; P=0.009) and ECV ≥32.6% on CT (HR, 6.96; 95% CI, 1.92-25.12; P=0.003) were independent predictors of composite outcomes. On Kaplan-Meier analysis, the higher ECV group (≥32.6%) had a significantly greater number of composite outcomes than the lower ECV group (P<0.001). CONCLUSIONS: ECV on CT is an independent predictor of prognosis after TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Prognóstico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Tomografia Computadorizada por Raios X , Fatores de Risco
2.
Circ J ; 88(4): 539-548, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38447968

RESUMO

BACKGROUND: The introduction of transcatheter edge-to-edge repair for moderate-to-severe or severe mitral regurgitation (MR) utilizing the MitraClip system became reimbursed and clinically accessible in Japan in April 2018. This study presents the 2-year clinical outcomes of all consecutively treated patients who underwent MitraClip implantation in Japan and were prospectively enrolled in the Japanese Circulation Society-oriented J-MITRA registry.Methods and Results: Analysis encompassed 2,739 consecutive patients enrolled in the J-MITRA registry with informed consent (mean age: 78.3±9.6 years, 1,550 males, STS risk score 11.7±8.9), comprising 1,999 cases of functional MR, 644 of degenerative MR and 96 in a mixed group (DMR and FMR). The acute procedure success rate was 88.9%. After MitraClip implantation, >80% exhibited an MR grade ≤2+ and the trend was sustained over the 2 years. Within this observation period, the mortality rate was 19.3% and the rate of heart failure readmissions was 20.6%. The primary composite endpoint, inclusive of cardiovascular death and heart failure readmission, was significantly higher in patients with functional MR than in with degenerative MR (32.0% vs. 17.5%, P<0.001). CONCLUSIONS: The 2-year clinical outcomes after MitraClip implantation were deduced from comprehensive data within an all-Japan registry.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Dados de Saúde Coletados Rotineiramente , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos
3.
J Artif Organs ; 27(1): 7-14, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36933087

RESUMO

Left ventricular assist devices improve prognosis and quality of life, but exercise capacity remains limited in most patients after device implantation. Left ventricular assist device optimization through right heart catheterization reduces device-related complications. However, hemodynamic parameters associated with exercise capacity under optimized conditions. The aim of this study was to elucidate the predictors of exercise capacity from hemodynamic parameters at rest after left ventricular assist device optimization. We retrospectively reviewed 24 patients who underwent a ramp test with right heart catheterization, echocardiography and cardiopulmonary exercise testing more than 6 months after left ventricular assist device implantation. Pump speed was optimized to a lower setting that achieved right atrial pressure < 12 mmHg, pulmonary capillary wedge pressure < 18 mmHg, and cardiac index > 2.2 L/min/m2, then exercise capacity was assessed by cardiopulmonary exercise testing. After left ventricular assist device optimization, the mean right atrial pressure, pulmonary capillary wedge pressure, cardiac index, and peak oxygen consumption were 7 ± 5 mmHg, 10 ± 7 mmHg, 2.7 ± 0.5 L/min/m2, and 13.2 ± 3.0 mL/min/kg, respectively. Pulse pressure, stroke volume, right atrial pressure, mean pulmonary artery pressure, and pulmonary capillary wedge pressure were significantly associated with peak oxygen consumption. Multivariate linear regression analysis of factors predicting peak oxygen consumption revealed that pulse pressure, right atrial pressure, and aortic insufficiency remained independent predictors (ß = 0.401, p = 0.007; ß = - 0.558, p < 0.001; ß = - 0.369, p = 0.010, respectively). Our findings suggests that cardiac reserve, volume status, right ventricular function, and aortic insufficiency predict exercise capacity in patients with a left ventricular assist device.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Tolerância ao Exercício , Qualidade de Vida , Hemodinâmica , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Teste de Esforço/efeitos adversos , Função Ventricular Esquerda
4.
Heart Lung Circ ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38964943

RESUMO

BACKGROUND: Using echocardiography to assess right ventricular (RV) function after cardioplegic arrest is challenging. Cardiac magnetic resonance (CMR) imaging is a superior alternative, with the feature tracking technique enabling quantitative assessment of myocardial deformation. METHODS: This single-center, prospective study from 2020 to 2022 assessed RV function in 42 patients who underwent open heart surgery with cardioplegic arrest. CMR data were collected preoperatively, one week postoperatively, and at follow-up (6-12 months after surgery), and assessed using the CMR feature tracking technique. RESULTS: Postoperatively, there was no significant change in RV end-diastolic volume, but RV end-systolic volume significantly decreased, leading to a notable increase in RV ejection fraction. By follow-up, both RV end-diastolic and end-systolic volumes had significantly reduced compared with the preoperative values. Right ventricular longitudinal contractility decreased after surgery but recovered to the preoperative values by follow-up, while RV circumferential contractility improved postoperatively and remained superior to the preoperative levels at follow-up. CONCLUSION: On CMR imaging, significant changes in RV systolic motion were observed after cardioplegic arrest, with decreased longitudinal but increased circumferential contractility. At follow up, these changes had reverted to the preoperative patterns by the mid-term (6-12 months).

5.
Circ J ; 87(8): 1103-1111, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37258218

RESUMO

BACKGROUND: Recently, destination therapy (DT) was approved in Japan, and patients ineligible for heart transplantation may now receive durable left ventricular assist devices (LVADs). Several conventional risk scores are available, but a risk score that is best to select optimal candidates for DT in the Japanese population remains unestablished.Methods and Results: A total of 1,287 patients who underwent durable LVAD implantation and were listed for the Japanese registry for Mechanically Assisted Circulatory Support (J-MACS) were eligible for inclusion. Finally, 494 patients were assigned to the derivation cohort and 487 patients were assigned to the validation cohort. According to the time-to-event analyses, J-MACS risk scores were newly constructed to predict 3-year mortality rate, consisting of age, history of cardiac surgery, serum creatinine level, and central venous pressure to pulmonary artery wedge pressure ratio >0.71. The J-MACS risk score had the highest predictability of 3-year death compared with other conventional scores in the validation cohort, including HeartMate II risk score and HeartMate 3 risk score. CONCLUSIONS: We constructed the J-MACS risk score to estimate 3-year mortality rate after durable LVAD implantation using large-scale multicenter Japanese data. The clinical utility of this scoring to guide the indication of DT should be validated in the next study.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Dados de Saúde Coletados Rotineiramente , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos
6.
Surg Today ; 53(3): 369-378, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36018416

RESUMO

PURPOSE: Neurologic adverse events (NAEs) are a major complication after pulmonary endarterectomy (PEA) performed under periods of deep hypothermic circulatory arrest (HCA) for chronic thromboembolic pulmonary hypertension. We modified the PEA strategy to prevent NAEs and evaluated the effectiveness of these modifications. METHODS: We reviewed the surgical outcomes of 87 patients divided into the following three groups based on the surgical strategy used: group S (n = 49), periods of deep HCA with alpha-stat strategy; group M1 (n = 19), deep HCA with modifications of slower cooling and rewarming rates and the pH-stat strategy for cooling: and group M2 (n = 13), multiple short periods of moderate HCA. RESULTS: PEA provided significant improvement of pulmonary hemodynamics in each group. Sixteen (29%) of the 49 group S patients suffered NAEs, associated with total circulatory arrest time (cutoff, 57 min) and Jamieson type I disease. The Group M1 and M2 patients did not suffer NAEs, although the group M1 patients had prolonged cardiopulmonary bypass (CPB) and more frequent respiratory failure. CONCLUSIONS: NAEs were common after PEA performed under periods of deep HCA. The modified surgical strategy could decrease the risk of NAEs but increase the risk of respiratory failure. Multiple short periods of moderate HCA may be useful for patients at risk of NAEs.


Assuntos
Hipotermia Induzida , Insuficiência Respiratória , Humanos , Ponte Cardiopulmonar , Endarterectomia , Hipotermia Induzida/efeitos adversos , Pulmão , Insuficiência Respiratória/etiologia
7.
Int Heart J ; 64(2): 306-309, 2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-36927939

RESUMO

Renovascular hypertension (RVH) is a common cause of secondary hypertension. However, there have been no reports on RVH due to radiation-induced abdominal aorta stenosis after renal autotransplantation. A 27-year-old woman with a history of neuroblastoma treated by radiation therapy and RVH treated with renal autotransplantation presented with hypertension and dyspnea. At age 19, she had experienced hypertensive heart failure due to RVH from radiation-induced left renal artery stenosis and had undergone renal autotransplantation involving the extraction of her left kidney. Her systolic blood pressure (BP) was well-controlled but had increased progressively. She was diagnosed with hypertensive heart failure and admitted to hospital. Although her dyspnea soon subsided after treatment, her BP remained high. Renal artery ultrasound revealed no obvious stenosis. The ankle brachial pressure index (ABI) showed a significant bilateral decrease to 0.71/0.71 (right/left) from 0.94/0.95 eight years before. Magnetic resonance angiography and aortic angiography revealed severe stenosis in the abdominal aorta, and the systolic pressure gradient of intra-aortic blood flow, distal and proximal to a stenotic lesion, was 58 mmHg. These arterial stenoses in the irradiated area were highly suggestive of radiation-induced vasculopathy. She finally underwent an endovascular VIABAHN VBX balloon-expandable stent-graft placement for this radiation-induced abdominal aorta stenosis, which resolved the pressure gradient. After the procedure, her ABI improved to 0.91/0.88 and her BP was well-controlled. This is the first case of successful stent-graft placement for RVH after renal autotransplantation due to radiation-induced abdominal aorta stenosis as a consequence of neuroblastoma.


Assuntos
Estenose da Valva Aórtica , Hipertensão Renovascular , Hipertensão , Neuroblastoma , Humanos , Feminino , Adulto Jovem , Adulto , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Transplante Autólogo/efeitos adversos , Transplante Autólogo/métodos , Hipertensão Renovascular/diagnóstico , Hipertensão Renovascular/etiologia , Hipertensão Renovascular/cirurgia , Hipertensão/complicações , Stents/efeitos adversos , Estenose da Valva Aórtica/complicações , Neuroblastoma/complicações , Neuroblastoma/radioterapia , Resultado do Tratamento
8.
Circ J ; 2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36575039

RESUMO

BACKGROUND: Limited data are available for clinical outcomes in patients who underwent urgent or emergency transcatheter aortic valve implantation (TAVI). This study investigated in-hospital and 1-year outcomes and explored prognostic covariates in urgent/emergency TAVI using nationwide registry data.Methods and Results: Among 26,775 patients who underwent TAVI between August 2013 and December 2019, 25,495 with 1-year follow-up information were analyzed in this study. Baseline and procedural characteristics, as well as clinical adverse events, were compared between the urgent/emergency and elective TAVI groups. The primary outcome was all-cause mortality within 1 year after TAVI. Multivariable Cox regression models were constructed to identify independent predictors after urgent or emergency TAVI. Urgent or emergency TAVI was performed in 578 (2.3%) patients. The Society of Thoracic Surgeons score was significantly higher in the urgent/emergency than elective TAVI group (13.3% vs. 6.0%; P<0.001). Device success rate was comparable between the 2 groups. All-cause death-free survival within 1 year was lower in the urgent/emergency than elective TAVI group (77.2% vs. 92.2%; log rank P<0.001). Malignancy, albumin and creatinine concentrations, ejection fraction, and mean pressure gradient were associated with 1-year mortality in the urgent/emergency TAVI group. CONCLUSIONS: Despite higher surgical risk and more comorbidities, the procedure was successfully performed in patients undergoing urgent/emergency TAVI, although it should be noted that prognosis was worse than for elective TAVI.

9.
Circ J ; 86(12): 1950-1958, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-35786688

RESUMO

BACKGROUND: The objective of this study is to investigate the effect of preoperative diabetes on all-cause mortality and major postoperative complications among patients with continuous-flow left ventricular assist device (LVAD) by using data from a national database.Methods and Results: The 545 study patients who underwent primary HeartMateII implantation between 2013 and 2019 were divided into 2 groups according to their diabetes mellitus (DM) status; patients with DM (n=116) and patients without DM (n=429). First, the on-device survival and incidence of adverse events were evaluated. Second, after adjusting for patients' backgrounds, the change of laboratory data in the 2 groups were compared. Overall, on-device survival at 1, 2, and 3 years was almost equivalent between the 2 groups; it was 95%, 94%, and 91% in patients without DM, and 93%, 91%m and 91% in patients with DM (P=0.468) The incidence of adverse events was similar between 2 groups of patients, except for driveline exit site infection in the adjusted cohort. Cox proportional hazards regression analysis revealed younger age (HR: 0.98 (95% confidence interval (CI): 0.97-0.99, P=0.001) and presence of DM (HR: 1.83 (95% CI: 1.14-2.88), P=0.016) as significant predictors of driveline infection. Laboratory findings revealed no differences between groups throughout the periods. CONCLUSIONS: The clinical results after LVAD implantation in DM patients were comparable with those in non-DM patients, except for the driveline exit site infection.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Japão/epidemiologia , Resultado do Tratamento , Estudos Retrospectivos
10.
J Artif Organs ; 25(3): 204-213, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34826019

RESUMO

The hemodynamic and exercise capacity performance of the Jarvik 2000 left ventricular assist device (LVAD), which is generally used in patients with small body size and relatively preserved cardiac function, is not well understood. We retrospectively examined 18 patients implanted with the Jarvik 2000 LVAD. Pump rotation speed was optimized by the hemodynamic ramp test one year after implantation based on the criteria of mean pulmonary capillary wedge pressure (PCWP) < 18 mmHg, mean right atrial pressure (RAP) < 12 mmHg, and cardiac index (CI) > 2.2 L/min/m2 as well as echocardiographic parameters. Exercise capacity was assessed by cardiopulmonary exercise test in an optimized setting. To investigate the impacts of larger body surface area (BSA) and extremely impaired pre-implantation cardiac function on hemodynamics and exercise capacity, two correlation analyses based on BSA and original CI were performed. At a pump speed of 9500 ± 707 rpm, the mean pulmonary artery pressure, PCWP, RAP, and CI were 17 ± 5 mmHg, 9 ± 5 mmHg, 6 ± 4 mmHg, and 2.82 ± 0.54 L/min/m2, respectively. Only one patient failed to achieve the hemodynamic criteria. The peak VO2 and VE/VCO2 slope were 12.9 ± 3.1 mL/min/kg and 37.7 ± 15.0, respectively. There was an inverse correlation between original CI and heart rate (r = -0.60, p = 0.01), and a weak correlation between BSA and PCWP (r = 0.43, p = 0.08). Based on this study, the overall performance of the Jarvik 2000 device was acceptable, and the patients' body size and original cardiac function had minimum effect on the performance of this device.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Teste de Esforço , Tolerância ao Exercício , Hemodinâmica , Humanos , Estudos Retrospectivos , Função Ventricular Esquerda
11.
J Card Surg ; 37(12): 5613-5615, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378936

RESUMO

A 63-year-old male, with a history of coronary artery bypass grafting using bilateral internal thoracic artery (ITA) grafts, underwent surgical aortic valve replacement (AVR). Avoiding the graft injury, we selected the right anterior minithoracotomy approach under cardiac arrest with systemic hyperkalemia with remaining bilateral ITA grafts open. Deep hypothermia was induced to obtain more reliable myocardial protection. We believe this strategy can be considered as a therapeutic option in patients requiring AVR but unsuitable for transcatheter AVR.


Assuntos
Próteses Valvulares Cardíacas , Artéria Torácica Interna , Masculino , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Artéria Torácica Interna/cirurgia , Reoperação , Ponte de Artéria Coronária
12.
J Card Surg ; 37(7): 2134-2137, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35481588

RESUMO

A 39-year-old woman with a history of Alport syndrome was admitted to our hospital for heart failure due to severe aortic regurgitation. Computed tomography revealed a chronic type A aortic dissection that required valve-sparing aortic root replacement. The pathological examination demonstrated that elastic fibers in the tunica media of the aortic wall are torn and severely disorganized. Immunostaining showed fragmented alpha 5 chains, indicating Alport syndrome. These findings imply Alport syndrome may have connective tissue vulnerability, rendering patients susceptible to the development of aortic disease at a young age.


Assuntos
Dissecção Aórtica , Insuficiência da Valva Aórtica , Nefrite Hereditária , Adulto , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Feminino , Humanos , Nefrite Hereditária/complicações
13.
Kyobu Geka ; 75(10): 791-795, 2022 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-36155571

RESUMO

Left ventricular free wall rupture( LVFWR) is a potentially fatal complication after acute myocardial infarction (AMI). Its onset is often unpredictable and circulatory collapse develops abruptly. When cardiac tamponade is detected after AMI, pericardial drainage should be performed promptly. If percutaneous drainage is ineffective, surgical drainage should be performed without hesitation. Veno-arterial extracorporeal oxygenation (VA-ECMO) cannot necessarily provide effective brain protection because of elevated venous pressure. Although suture-less repair often results in sufficient hemostasis, recurrent rupture sometimes develops. If any type of LVFWR is suspected, immediate surgical intervention can save lives.


Assuntos
Tamponamento Cardíaco , Ruptura Cardíaca , Infarto do Miocárdio , Tamponamento Cardíaco/etiologia , Ruptura Cardíaca/etiologia , Ruptura Cardíaca/cirurgia , Humanos , Infarto do Miocárdio/complicações
14.
BMC Pulm Med ; 21(1): 407, 2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34886828

RESUMO

BACKGROUND: Chronic thromboembolic pulmonary hypertension (CTEPH) is a type of pulmonary hypertension caused by persistent thromboembolism of the pulmonary arteries. In clinical practice, CTEPH patients often show obstructive ventilatory impairment, even in the absence of a smoking history. Recent reports imply a tendency for CTEPH patients to have a lower FEV1.0; however, the mechanism underlying obstructive impairment remains unknown. METHODS: We retrospectively analyzed CTEPH patients who underwent a pulmonary function test and respiratory impedance test to evaluate their exertional dyspnea during admission for right heart catheterization from January 2000 to December 2019. We excluded patients with a smoking history to rule out the effect of smoking on obstructive impairment. RESULTS: A total of 135 CTEPH patients were analyzed. The median FEV1.0/FVC was 76.0%, %FEV 1.0 had a negative correlation with the mean pulmonary artery pressure and pulmonary vascular resistance and the CT Angiogram (CTA) obstruction score. A multivariate regression analysis revealed that the CTA obstruction score was an independent factor of a lower %FEV1.0. In the 54 patients who underwent pulmonary endarterectomy, %FEV1.0 was improved in some cases and was not in some. Mean PAP largely decreased after PEA in the better %FEV1.0 improved cases, suggesting that vascular involvement in CTEPH could be associated with spirometry obstructive impairment. CONCLUSION: %FEV1.0 had a significant correlation with the CTA obstruction score. Obstructive impairment might have an etiological relationship with vascular involvement. Further investigations could shed new light on the etiology of CTEPH.


Assuntos
Hipertensão Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia , Resistência Vascular , Idoso , Cateterismo Cardíaco , Doença Crônica , Endarterectomia , Feminino , Fluxo Expiratório Forçado , Humanos , Hipertensão Pulmonar/diagnóstico , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico , Estudos Retrospectivos , Espirometria
15.
J Artif Organs ; 24(2): 191-198, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33420874

RESUMO

Aortic insufficiency (AI) is known to associate with a persistently closed aortic valve during continuous-flow ventricular assist device support. Some devices carry an intermittent low-speed (ILS) function, which facilitates aortic valve opening, but whether this function prevents AI is unknown. In this study, the Jarvik 2000 device, which is programmed to reduce the pump speed each minute for 8 s, was chosen to examine this potential effect. Prospectively collected data of 85 heart transplant-eligible Jarvik 2000 recipients who met the study criteria (no pre-existing AI and aortic valve surgery) were retrospectively analyzed for the incidence, correlating factors, and clinical outcomes of de novo AI. All data were provided by the Japanese Registry for Mechanically Assisted Circulatory Support. De novo AI occurred in 58 patients, 23 of whom developed at least moderate AI during a median support duration of 23.5 months. Freedom from moderate or greater AI was 84.4%, 66.1% and 60.2% at 1, 2 and 3 years, respectively. Multivariate analyses revealed that progressive AI was correlated with decreased pulse pressure after implantation (hazard ratio 1.060, 95% confidence interval 1.001-1.127, p = 0.045). No correlation was found for mortality or other adverse events, including stroke, bleeding, infection, pump failure, hemolysis, and readmission. The benefit of the Jarvik 2000's current ILS mode against AI appears to be minimal. However, in this limited cohort where all recipients underwent implantation as a bridge to transplantation, the impact of de novo progressive AI on other clinical adversities was also minimal.


Assuntos
Insuficiência da Valva Aórtica/prevenção & controle , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Adulto , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo
16.
Circ J ; 84(12): 2198-2204, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33148939

RESUMO

BACKGROUND: The bridge-to-bridge (BTB) strategy, a conversion to durable left ventricular assist device (LVAD) after stabilization using surgical temporary mechanical circulatory supports for a couple of months, is not uncommon in Japan. However, its effect on clinical outcomes in comparison with a primary durable LVAD implantation strategy remains unknown.Methods and Results:Data of 837 consecutive patients (median age 45, 73% males) who underwent durable LVAD implantation as BTB (n=168) or primary implant (n=669) between April 2011 and April 2019 were retrospectively reviewed from the prospective multicenter Japanese mechanically assisted circulatory support registry. The BTB group was younger and had comparable end-organ function, better hemodynamic profile, and longer operative time compared with the primary implant group at baseline. The 3-year survival was 80% vs. 87% (P=0.007) for the BTB and primary implant groups respectively, with greater observed rates of stroke and infection as the predominant causes of death. The BTB strategy was independently associated with increased 3-year mortality (hazard ratio 2.69 [1.43-5.07], P=0.002) in addition to other significant risk factors. CONCLUSIONS: The BTB cohort had comparable baseline characteristics to the primary implant cohort at the time of durable LVAD conversion, but had lower 3-year survival. Detailed analysis clarifying the causality of this finding should improve outcomes with the BTB strategy.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/terapia , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
17.
Circ J ; 84(6): 926-934, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32295976

RESUMO

BACKGROUND: Infective endocarditis remains associated with substantial mortality and morbidity rates, and the presence of acute heart failure (AHF) compromises clinical results after valve surgery; however, little is known in cardiogenic shock (CGS) patients. This study evaluated the clinical results and risk of mortality in CGS patients after valve surgery.Methods and Results:This study enrolled 585 patients who underwent valve surgery for active endocarditis at 14 institutions between 2009 and 2017. Of these patients, 69 (12%) were in CGS, which was defined as systolic blood pressure <80 mmHg and severe pulmonary congestion, requiring mechanical ventilation and/or mechanical circulatory support, preoperatively. The predictors of CGS were analyzed, and clinical results of patients with non-CGS AHF (n=215) were evaluated and compared.Staphylococcus aureusinfection (odds ratio [OR] 2.19; P=0.044), double valve involvement (OR 3.37; P=0.003), and larger vegetation (OR 1.05; P=0.036) were risk factors for CGS. Hospital mortality occurred in 27 (13%) non-CGS AHF patients and in 15 (22%) CGS patients (P=0.079). Overall survival at 1 and 5 years in CGS patients was 76% and 69%, respectively, and there were no significant differences in overall survival compared with non-CGS AHF patients (P=1.000). CONCLUSIONS: Clinical results after valve surgery in CGS patients remain challenging; however, mid-term results were equivalent to those of non-CGS AHF patients.


Assuntos
Circulação Assistida , Endocardite Bacteriana/cirurgia , Oxigenação por Membrana Extracorpórea , Implante de Prótese de Valva Cardíaca , Choque Cardiogênico/terapia , Idoso , Circulação Assistida/efeitos adversos , Circulação Assistida/mortalidade , Bases de Dados Factuais , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/fisiopatologia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Balão Intra-Aórtico , Japão , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
18.
BMC Cardiovasc Disord ; 20(1): 116, 2020 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-32138671

RESUMO

BACKGROUND: Left ventricular reverse remodeling (LVRR) has been detected in non-ischemic dilated cardiomyopathy (NIDCM) patients following optimal treatment. However, its prediction with only conventional modalities is often difficult. This study sought to examine whether RNA sequencing (RNA-seq) of myocardium tissue samples could predict LVRR in NIDCM. METHODS: A total of 17 advanced NIDCM patients with left ventricular ejection fraction (LVEF) below 30% who underwent cardiac biopsy from Left ventricle (LV) were prospectively recruited. They received optimal treatment and followed with echocardiogram every 6 months. Based on LVRR status after 12 months of treatment, patients were divided into the reverse remodeling (RR) or non-RR group. Tissue samples were analyzed by RNA-seq, and a functional analysis of differentially expressed genes was carried out. RESULTS: There were eight and nine patients in the RR and non-RR groups, respectively. No difference was found in age, sex, disease duration, LV end-diastolic diameter, and LVEF between the two groups. There were 155 genes that were differentially expressed between the two groups. Nicotinamide adenine dinucleotide ubiquinone oxidoreductase subunit (NDUF)S5 and Growth arrest and DNA-damage-inducible protein (GADD)45G, along with several genes related to the mitochondrial respiratory chain and ribosome, were significantly downregulated in the RR as compared to the non-RR group. CONCLUSION: GADD45G and NDUFS5 are potential biomarkers for LVRR in patients with advanced NIDCM.


Assuntos
Complexo I de Transporte de Elétrons/genética , Insuficiência Cardíaca/genética , Peptídeos e Proteínas de Sinalização Intracelular/genética , RNA-Seq , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Feminino , Marcadores Genéticos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos
19.
J Artif Organs ; 23(3): 270-274, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31897739

RESUMO

Left ventricular assist device (LVAD) is an established therapy for patients with severe heart failure. Because the incidence of cardiotoxicity owing to anticancer agents is low, it is difficult to predict the recovery prospects when the cause of heart failure is due to anticancer agents. In this context, cancer patients who present with severe symptoms of heart failure and who fail medical therapy for heart failure may pose a dilemma, especially in countries such as Japan where implantable LVADs are not approved for purposes other than bridging to transplant. Recently, we encountered a 32-year-old woman with chemotherapy-related cardiomyopathy that developed after anticancer treatment using trastuzumab and anthracycline. LVAD therapy was the only option to save the young woman. The patient received an extracorporeal LVAD, her cardiac function gradually recovered while on support, and the device was successfully removed.


Assuntos
Antraciclinas/efeitos adversos , Antineoplásicos/efeitos adversos , Insuficiência Cardíaca/induzido quimicamente , Insuficiência Cardíaca/terapia , Coração Auxiliar , Trastuzumab/efeitos adversos , Adulto , Feminino , Humanos , Leucemia Mieloide Aguda/tratamento farmacológico
20.
J Card Surg ; 35(7): 1464-1470, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32445193

RESUMO

OBJECTIVES: To elucidate the impact of regulation of tricuspid regurgitation (TR) using tricuspid annuloplasty on postoperative changes in right ventricular (RV) systolic and diastolic functions. METHODS: We enrolled 69 patients who underwent aortic or mitral valve surgery between July 2016 to March 2018 without recurrence. Patients with concomitant coronary artery bypass grafting or a history of previous cardiovascular surgery were excluded, remaining 45 patients enrolled. Patients were divided into two groups according to concomitant tricuspid annuloplasty (T: n = 12 vs non-T: n = 33). RV global longitudinal strain (RVGLS), RV fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE), and early tricuspid inflow velocity/early diastolic tricuspid annular velocity ratio (tricuspid E/e') were assessed as functional indices at preoperative, postoperative and 1-year follow-up periods. RESULTS: RVFAC deteriorated postoperatively but recovered at follow-up in group T, whereas that in group non-T showed gradual deterioration overtime. RVGLS and TAPSE showed similar temporary deterioration and recovery between groups. Tricuspid E in group T increased postoperatively and showed significant difference, which was kept until follow-up period. Tricuspid e' decreased postoperatively, and recovered slightly in both groups. As a result, postoperative RV diastolic function (tricuspid E/e') showed significant difference between groups. This difference was maintained until follow-up. CONCLUSIONS: RV systolic function deteriorated postoperatively, but there was a tendency to improve at follow-up regardless of tricuspid annuloplasty. RV diastolic function may potentially be impaired when TR was regulated by tricuspid annuloplasty.


Assuntos
Diástole , Ventrículos do Coração/fisiopatologia , Anuloplastia da Valva Mitral , Complicações Pós-Operatórias/fisiopatologia , Sístole , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Idoso , Velocidade do Fluxo Sanguíneo , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Valva Tricúspide/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA