Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Biochem ; 642: 114564, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35081373

RESUMO

Seneca Valley virus (SVV) is related to vesicular disease in pigs, and its clinical symptoms are indistinguishable from other notifiable clinical symptoms of vesicular disease such as foot-and-mouth disease. The rapid and accurate detection of SVV is essential to confirm the pathogenic factors and initiate the implementation of control measures. The development of a rapid, simple, convenient, and low-cost molecular (nucleic acid amplification) test that can be used at the sample collection point has been identified as a key component for controlling SVV. This study describes the development and demonstration of recombinase polymerase amplification (RPA) test targeting the conserved regions of SVV for detection of SVV. The Primers and probes designed by us have shown good sensitivity and specificity in RPA test, which is helpful for RPA to be an effective tool for rapid diagnosis of SVV.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Picornaviridae/genética , Reação em Cadeia da Polimerase em Tempo Real , Picornaviridae/isolamento & purificação
2.
Sens Actuators B Chem ; 3692022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38756788

RESUMO

Effective control of epidemics, individualized medicine, and new drugs with virologic response-dependent dose and timing require, among other things, simple, inexpensive, multiplexed molecular detection platforms suitable for point of care and home use. Herein, we describe our progress towards developing such a platform that includes sample lysis, nucleic acid isolation, concentration, purification, and amplification. Our diagnostic device comprises a sliding component that houses the nucleic acid isolation membrane and a housing containing three amplification reaction chambers with dry stored reagents, blisters with buffers and wash solutions, and absorption pads to facilitate capillarity pull and waste storage. After sample introduction, the user slides the slider within the housing from one station to another to carry out various unit operations. The slider motion induces blisters to discharge their contents, effectuating washes, and eventual elution of captured nucleic acids into reaction chambers. The slider cassette mates with a processor that incubates isothermal amplification but can also be made to operate instrumentation-free. We demonstrate our cassette's utility for the co-detection of the human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV). These three blood-borne pathogens co-infect many people worldwide with severe personal and public health consequences.

3.
Nucleic Acids Res ; 48(4): e19, 2020 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-31828328

RESUMO

Detection of disease-associated, cell-free nucleic acids in body fluids enables early diagnostics, genotyping and personalized therapy, but is challenged by the low concentrations of clinically significant nucleic acids and their sequence homology with abundant wild-type nucleic acids. We describe a novel approach, dubbed NAVIGATER, for increasing the fractions of Nucleic Acids of clinical interest Via DNA-Guided Argonaute from Thermus thermophilus (TtAgo). TtAgo cleaves specifically guide-complementary DNA and RNA with single nucleotide precision, greatly increasing the fractions of rare alleles and, enhancing the sensitivity of downstream detection methods such as ddPCR, sequencing, and clamped enzymatic amplification. We demonstrated 60-fold enrichment of the cancer biomarker KRAS G12D and ∼100-fold increased sensitivity of Peptide Nucleic Acid (PNA) and Xenonucleic Acid (XNA) clamp PCR, enabling detection of low-frequency (<0.01%) mutant alleles (∼1 copy) in blood samples of pancreatic cancer patients. NAVIGATER surpasses Cas9-based assays (e.g. DASH, Depletion of Abundant Sequences by Hybridization), identifying more mutation-positive samples when combined with XNA-PCR. Moreover, TtAgo does not require targets to contain any specific protospacer-adjacent motifs (PAM); is a multi-turnover enzyme; cleaves ssDNA, dsDNA and RNA targets in a single assay; and operates at elevated temperatures, providing high selectivity and compatibility with polymerases.


Assuntos
Proteínas Argonautas/genética , Ácidos Nucleicos Livres/genética , Neoplasias/genética , Ácidos Nucleicos Peptídicos/genética , Alelos , Humanos , Mutação/genética , Neoplasias/diagnóstico , Neoplasias/patologia , Ácidos Nucleicos Peptídicos/isolamento & purificação , Thermus thermophilus/genética
4.
Chin Chem Lett ; 33(8): 4126-4132, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36091579

RESUMO

Liquid biopsy is a highly promising method for non-invasive detection of tumor-associated nucleic acid fragments in body fluids but is challenged by the low abundance of nucleic acids of clinical interest and their sequence homology with the vast background of nucleic acids from healthy cells. Recently, programmable endonucleases such as clustered regularly interspaced short palindromic repeat (CRISPR) associated protein (Cas) and prokaryotic Argonautes have been successfully used to remove background nucleic acids and enrich mutant allele fractions, enabling their detection with deep next generation sequencing (NGS). However, the enrichment level achievable with these assays is limited by futile binding events and off-target cleavage. To overcome these shortcomings, we conceived a new assay (Programmable Enzyme-Assisted Selective Exponential Amplification, PASEA) that combines the cleavage of wild type alleles with concurrent polymerase amplification. While PASEA increases the numbers of both wild type and mutant alleles, the numbers of mutant alleles increase at much greater rates, allowing PASEA to achieve an unprecedented level of selective enrichment of targeted alleles. By combining CRISPR-Cas9 based cleavage with recombinase polymerase amplification, we converted samples with 0.01% somatic mutant allele fractions (MAFs) to products with 70% MAFs in a single step within 20 min, enabling inexpensive, rapid genotyping with such as Sanger sequencers. Furthermore, PASEA's extraordinary efficiency facilitates sensitive real-time detection of somatic mutant alleles at the point of care with custom designed Exo-RPA probes. Real-time PASEA' performance was proved equivalent to clinical amplification refractory mutation system (ARMS)-PCR and NGS when testing over hundred cancer patients' samples. This strategy has the potential to reduce the cost and time of cancer screening and genotyping, and to enable targeted therapies in resource-limited settings.

5.
Analyst ; 146(13): 4212-4218, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34075937

RESUMO

Molecular detection of pathogenic nucleic acids from patient samples requires incubating biochemical reactions at specific temperatures to amplify DNA. This incubation is typically carried out with an electrical heater and a temperature controller. To reduce test cost, to eliminate the need for manufacturing incubators, which may require significant time, and to enable electricity-free operation, we use energetic compounds such as an Mg(Fe) alloy mixed with a phase-change material (PCM) that undergoes phase transformation at the desired incubation temperature. We dubbed this composite Energetic Phase Change Material (EPCM). When the EPCM is brought into contact with water, the magnesium alloy interacts with the water to produce heat. The EPCM heats up to its phase transition temperature. Any excess heat is absorbed as latent heat and the system is maintained at its desired incubation temperature, independent of ambient temperatures, long enough to facilitate enzymatic amplification. The EPCM together with colorimetric amplicon detection facilitates an inexpensive, disposable, point-of-need diagnostic test that does not require any electric power. We demonstrate the feasibility of our approach by detecting SARS-Cov-2 in saliva samples either without any instrumentation or with a palm-size CCD camera that enables us to follow the amplification process in real time.


Assuntos
COVID-19 , DNA/genética , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , Saliva
6.
Analyst ; 145(18): 6138-6147, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32869771

RESUMO

Traditionally, plasma is extracted from whole blood using centrifuges in clinical laboratories, which is unsuitable for on-site testing. For point-of-care diagnostics, for example in HIV tests, to ensure the detection sensitivity for low-abundance analytical targets, a relatively large volume of plasma needs to be extracted from milliliters of blood with a simpler and easier-to-operate method than centrifugation. We report the development of a membrane-assisted, sedimentation-facilitated plasma separator with a multifunctional deformable chamber, which is able to perform plasma separation from undiluted whole blood in a short time. Multiple steps related to plasma separation, including cell sedimentation, cell filtration, and plasma driving and discharging, are all performed in or through the multifunctional deformable chamber equipped with a top-layer porous membrane, which significantly reduces the device complexity. Assisted by a simple jig or even hands, plasma separation can be conveniently performed upon mechanical actuation of the deformable chamber. Within 8 min, ∼130 µL of plasma can be conveniently extracted with the described device from 2.3 mL of whole blood. It has been demonstrated that HIV antibodies or virus spiked in whole blood can be successfully detected with reasonable sensitivity from the extracted plasma with the described pump-free device.


Assuntos
Técnicas Analíticas Microfluídicas , Plasma , Centrifugação , Filtração , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Porosidade
7.
Anal Chem ; 90(2): 1209-1216, 2018 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-29226671

RESUMO

To enable inexpensive molecular detection at the point-of-care and at home with minimal or no instrumentation, it is necessary to streamline unit operations and store reagents refrigeration-free. To address this need, a multifunctional enzymatic amplification reactor that combines solid-phase nucleic acid extraction, concentration, and purification; refrigeration-free storage of reagents with just-in-time release; and enzymatic amplification is designed, prototyped, and tested. A nucleic acid isolation membrane is placed at the reactor's inlet, and paraffin-encapsulated reagents are prestored within the reactor. When a sample mixed with chaotropic agents is filtered through the nucleic acid isolation membrane, the membrane binds nucleic acids from the sample. Importantly, the sample volume is decoupled from the reaction volume, enabling the use of relatively large sample volumes for high sensitivity. When the amplification reactor's temperature increases to its operating level, the paraffin encapsulating the reagents melts and moves out of the way. The reagents are hydrated, just-in-time, and the polymerase reaction proceeds. The amplification process can be monitored, in real-time. We demonstrate our reactors' ability to amplify both DNA and RNA targets using polymerase with both reverse-transcriptase and strand displacement activities to obtain sensitivities on-par with benchtop equipment and a shelf life exceeding 6 months.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Ácidos Nucleicos/análise , Reação em Cadeia da Polimerase/instrumentação , Extração em Fase Sólida/instrumentação , DNA Viral/análise , DNA Viral/genética , Desenho de Equipamento , Liofilização , Papillomavirus Humano 16/genética , Papillomavirus Humano 16/isolamento & purificação , Humanos , Indicadores e Reagentes , Ácidos Nucleicos/genética , Infecções por Papillomavirus/virologia , Sistemas Automatizados de Assistência Junto ao Leito
8.
Anal Chem ; 90(7): 4823-4831, 2018 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-29542319

RESUMO

Rapid and quantitative molecular diagnostics in the field, at home, and at remote clinics is essential for evidence-based disease management, control, and prevention. Conventional molecular diagnostics requires extensive sample preparation, relatively sophisticated instruments, and trained personnel, restricting its use to centralized laboratories. To overcome these limitations, we designed a simple, inexpensive, hand-held, smartphone-based mobile detection platform, dubbed "smart-connected cup" (SCC), for rapid, connected, and quantitative molecular diagnostics. Our platform combines bioluminescent assay in real-time and loop-mediated isothermal amplification (BART-LAMP) technology with smartphone-based detection, eliminating the need for an excitation source and optical filters that are essential in fluorescent-based detection. The incubation heating for the isothermal amplification is provided, electricity-free, with an exothermic chemical reaction, and incubation temperature is regulated with a phase change material. A custom Android App was developed for bioluminescent signal monitoring and analysis, target quantification, data sharing, and spatiotemporal mapping of disease. SCC's utility is demonstrated by quantitative detection of Zika virus (ZIKV) in urine and saliva and HIV in blood within 45 min. We demonstrate SCC's connectivity for disease spatiotemporal mapping with a custom-designed website. Such a smart- and connected-diagnostic system does not require any lab facilities and is suitable for use at home, in the field, in the clinic, and particularly in resource-limited settings in the context of Internet of Medical Things (IoMT).


Assuntos
HIV/isolamento & purificação , Imagem Óptica , Patologia Molecular , Smartphone , Zika virus/isolamento & purificação , HIV/genética , Humanos , Internet , Medições Luminescentes , Técnicas de Amplificação de Ácido Nucleico , Zika virus/genética
9.
Clin Chem ; 63(3): 714-722, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28073898

RESUMO

BACKGROUND: The wide array of pathogens responsible for infectious diseases makes it difficult to identify causative pathogens with single-plex tests. Although multiplex PCR detects multiple targets, it is restricted to centralized laboratories, which delays test results or makes multiplexing unavailable, depriving healthcare providers of critical, real-time information. METHODS: To address the need for point-of-care (POC) highly multiplexed tests, we propose the 2-stage, nested-like, rapid (<40 min) isothermal amplification assay, dubbed rapid amplification (RAMP). RAMP's first-stage uses outer loop-mediated isothermal amplification (LAMP) primers to amplify all targets with recombinase polymerase amplification (RPA). First-stage amplicons are aliquoted to second stage reactors, each specialized for a specific target, to undergo LAMP. The assay is implemented in a microfluidic chip. LAMP amplicons are detected in situ with colorimetric dye or with a fluorescent dye and a smartphone. RESULTS: In experiments on a benchtop and in a microfluidic format, RAMP demonstrated high level of multiplexing (≥16); high sensitivity (i.e., 1 plaque-forming unit of Zika virus) and specificity (no false positives or negatives); speed (<40 min); ease of use; and ability to cope with minimally processed samples. CONCLUSIONS: RAMP is a hybrid, 2-stage, rapid, and highly sensitive and specific assay with extensive multiplexing capabilities, combining the advantages of RPA and LAMP, while circumventing their respective shortcomings. RAMP can be used in the lab, but one of its distinct advantages is amenability to simple implementation in a microfluidic format for use at the POC, providing healthcare personnel with an inexpensive, highly sensitive tool to detect multiple pathogens in a single sample, on site.


Assuntos
Técnicas Analíticas Microfluídicas , Reação em Cadeia da Polimerase Multiplex , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , Temperatura , Humanos
10.
Anal Chem ; 88(14): 7289-94, 2016 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-27306491

RESUMO

The recent outbreak of Zika virus (ZIKV) infection in the Americas and its devastating impact on fetal development have prompted the World Health Organization (WHO) to declare the ZIKV pandemic as a Public Health Emergency of International Concern. Rapid and reliable diagnostics for ZIKV are vital because ZIKV-infected individuals display no symptoms or nonspecific symptoms similar to other viral infections. Because immunoassays lack adequate sensitivity and selectivity and are unable to identify active state of infection, molecular diagnostics are an effective means to detect ZIKV soon after infection and throughout pregnancy. We report on a highly sensitive reverse-transcription loop-mediated, isothermal amplification (RT-LAMP) assay for rapid detection of ZIKV and its implementation in a simple, easy-to-use, inexpensive, point-of-care (POC) disposable cassette that carries out all the unit operations from sample introduction to detection. For thermal control of the cassette, we use a chemically heated cup without a need for electrical power. Amplification products are detected with leuco crystal violet (LCV) dye by eye without a need for instrumentation. We demonstrated the utility of our POC diagnostic system by detecting ZIKV in oral samples with sensitivity of 5 plaque-forming units (PFU) in less than 40 min. Our system is particularly suitable for resource-poor settings, where centralized laboratory facilities, funds, and trained personnel are in short supply, and for use in doctors' offices, clinics, and at home.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Zika virus/isolamento & purificação , Primers do DNA/metabolismo , Violeta Genciana/química , Humanos , Microfluídica , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/química , RNA Viral/isolamento & purificação , RNA Viral/metabolismo , Saliva/virologia , Zika virus/genética , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/virologia
12.
Sens Actuators B Chem ; 229: 232-238, 2016 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-26900258

RESUMO

Nucleic acid amplification-based diagnostics offer rapid, sensitive, and specific means for detecting and monitoring the progression of infectious diseases. However, this method typically requires extensive sample preparation, expensive instruments, and trained personnel. All of which hinder its use in resource-limited settings, where many infectious diseases are endemic. Here, we report on a simple, inexpensive, minimally-instrumented, smart cup platform for rapid, quantitative molecular diagnostics of pathogens at the point of care. Our smart cup takes advantage of water-triggered, exothermic chemical reaction to supply heat for the nucleic acid-based, isothermal amplification. The amplification temperature is regulated with a phase-change material (PCM). The PCM maintains the amplification reactor at a constant temperature, typically, 60-65°C, when ambient temperatures range from 12 to 35°C. To eliminate the need for an optical detector and minimize cost, we use the smartphone's flashlight to excite the fluorescent dye and the phone camera to record real-time fluorescence emission during the amplification process. The smartphone can concurrently monitor multiple amplification reactors and analyze the recorded data. Our smart cup's utility was demonstrated by amplifying and quantifying herpes simplex virus type 2 (HSV-2) with LAMP assay in our custom-made microfluidic diagnostic chip. We have consistently detected as few as 100 copies of HSV-2 viral DNA per sample. Our system does not require any lab facilities and is suitable for use at home, in the field, and in the clinic, as well as in resource-poor settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent.

14.
Anal Methods ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38919038

RESUMO

As of now, the global COVID-19 pandemic caused by SARS-CoV-2, which began in 2019, has been effectively controlled. However, the symptoms of influenza A virus infection were similar to those of SARS-CoV-2 infection, but they required different treatment approaches. To make the detection more accurate and the treatment more targeted. We developed a system that integrates RPA and CRISPR assays, allowing for the rapid, highly specific, and sensitive detection and differentiation of SARS-CoV-2, H1N1, and H3N2. Under isothermal amplification conditions, the RPA-CRISPR Cas12a detection system achieved a detection limit as low as 5 copies per µL, demonstrating excellent specificity. The measurement time was approximately 30 minutes. The RPA-CRISPR Cas12a detection system combined with the microfluidic chip we designed to simultaneously detect three viruses, providing a potential solution for efficient and reliable diagnosis.

16.
Anal Chim Acta ; 1264: 341283, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37230728

RESUMO

In resource-limited conditions such as the COVID-19 pandemic, on-site detection of diseases using the Point-of-care testing (POCT) technique is becoming a key factor in overcoming crises and saving lives. For practical POCT in the field, affordable, sensitive, and rapid medical testing should be performed on simple and portable platforms, instead of laboratory facilities. In this review, we introduce recent approaches to the detection of respiratory virus targets, analysis trends, and prospects. Respiratory viruses occur everywhere and are one of the most common and widely spreading infectious diseases in the human global society. Seasonal influenza, avian influenza, coronavirus, and COVID-19 are examples of such diseases. On-site detection and POCT for respiratory viruses are state-of-the-art technologies in this field and are commercially valuable global healthcare topics. Cutting-edge POCT techniques have focused on the detection of respiratory viruses for early diagnosis, prevention, and monitoring to protect against the spread of COVID-19. In particular, we highlight the application of sensing techniques to each platform to reveal the challenges of the development stage. Recent POCT approaches have been summarized in terms of principle, sensitivity, analysis time, and convenience for field applications. Based on the analysis of current states, we also suggest the remaining challenges and prospects for the use of the POCT technique for respiratory virus detection to improve our protection ability and prevent the next pandemic.


Assuntos
COVID-19 , Vírus , Humanos , Testes Imediatos , Pandemias
17.
Biomed Microdevices ; 13(5): 809-17, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21617995

RESUMO

A portable, fully automated analyzer that provides actuation and flow control to a disposable, self-contained, microfluidic cassette ("chip") for point-of-care, molecular testing is described. The analyzer provides mechanical actuation to compress pouches that pump liquids in the cassette, to open and close diaphragm valves for flow control, and to induce vibrations that enhance stirring. The analyzer also provides thermal actuation for the temperature cycling needed for polymerase chain reaction (PCR) amplification of nucleic acids and for various drying processes. To improve the temperature uniformity of the PCR chamber, the system utilizes a double-sided heating/cooling scheme with a custom feedforward, variable, structural proportional-integral-derivative (FVSPID) controller. The analyzer includes a programmable central processing unit that directs the sequence and timing of the various operations and that is interfaced with a computer. The disposable cassette receives a sample, and it carries out cell lysis, nucleic acid isolation, concentration, and purification, thermal cycling, and either real time or lateral flow (LF) based detection. The system's operation was demonstrated by processing saliva samples spiked with B. cereus cells. The amplicons were detected with a lateral flow assay using upconverting phosphor reporter particles. This system is particularly suited for use in regions lacking centralized laboratory facilities and skilled personnel.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Bacillus cereus/genética , Técnicas de Laboratório Clínico/instrumentação , Computadores , DNA Bacteriano/análise , Desenho de Equipamento , Humanos , Técnicas Analíticas Microfluídicas/métodos , Ácidos Nucleicos/análise , Ácidos Nucleicos/isolamento & purificação , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Saliva/microbiologia , Temperatura
18.
Sens Actuators B Chem ; 160(1): 1529-1535, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22125359

RESUMO

A portable, small footprint, light, general purpose analyzer (processor) to control the flow in immunoassay cassettes and to facilitate the detection of test results is described. The durable analyzer accepts disposable cassettes that contain pouches and reaction chambers for various unit operations such as hydration of dry reagents, stirring, and incubation. The analyzer includes individually controlled, linear actuators to compress the pouches in the cassette, which facilitates the pumping and mixing of sample and reagents, and to close diaphragm-based valves for flow control. The same types of actuators are used to compress pouches and actuate valves. The analyzer also houses a compact OEM scanner/reader to excite fluorescence and detect emission from labels. The analyzer is hydraulically isolated from the cassette, reducing the possibility of cross-contamination. The analyzer facilitates programmable, automated execution of a sequence of operations such as pumping and valving in a timely fashion, reducing the level of expertise required from the operator and the possibility for errors. The analyzer's design is modular and expandable to accommodate cassettes of various complexities and additional functionalities. In this paper, the utility of the analyzer has been demonstrated with the execution of a simple, consecutive, lateral flow assay of a model biological system and the test results were detected with up converting phosphor labels that are excited at infrared frequencies and emit in the visible spectrum.

19.
Animals (Basel) ; 11(11)2021 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-34827935

RESUMO

Infectious laryngotracheitis (ILT) is a viral disease of chickens' respiratory system that imposes considerable financial burdens on the chicken industry. Rapid, simple, and specific detection of this virus is crucial to enable proper control measures. Polymerase chain reaction (PCR)-based molecular tests require relatively expensive instruments and skilled personnel, confining their application to centralized laboratories. To enable chicken farms to take timely action and contain the spread of infection, we describe a rapid, simple, semi-quantitative benchtop isothermal amplification (LAMP) assay, and a field-deployable microfluidic device for the diagnosis of ILTV infection in chickens. Our assay performance was compared and favorably agreed with quantitative PCR (qPCR). The sensitivity of our real-time LAMP test is 250 genomic copies/reaction. Clinical performance of our microfluidic device using samples from diseased chickens showed 100% specificity and 100% sensitivity in comparison with benchtop LAMP assay and the gold-standard qPCR. Our method facilitates simple, specific, and rapid molecular ILTV detection in low-resource veterinary diagnostic laboratories and can be used for field molecular diagnosis of suspected ILT cases.

20.
Lab Chip ; 21(6): 1118-1130, 2021 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-33527920

RESUMO

The porcine epidemic diarrhea virus (PEDV), transmissible gastroenteritis virus (TGEV), and porcine deltacoronavirus (PDCoV) are emerging/reemerging coronaviruses (CoVs) of neonatal pigs that cause great economic losses to pig farms and pork processors. Specific, rapid, and simple multiplex detection of these viruses is critical to enable prompt implementation of appropriate control measures. Conventional methods for molecular diagnosis require skilled personnel and relatively sophisticated equipment, restricting their use in centralized laboratories. We developed a low-cost, rapid, semi-quantitative, field deployable, 3D-printed microfluidic device for auto-distribution of samples and self-sealing and real-time and reverse transcription-loop-mediated isothermal amplification (RT-LAMP), enabling the co-detection of PEDV, TGEV and PDCoV within 30 minutes. Our assay's analytical performance is comparable with a benchtop, real-time RT-LAMP assay and the gold standard quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assay with limits of detection of 10 genomic copies per reaction for PEDV and PDCoV, and 100 genomic copies per reaction for TGEV. Evaluation of clinical specimens from diseased pigs with our microfluidic device revealed excellent concordance with both benchtop RT-LAMP and qRT-PCR. Our portable RT-LAMP microfluidic chip will potentially facilitate simple, specific, rapid multiplexed detection of harmful infections in minimally equipped veterinary diagnostic laboratories and on-site in pigs' farms.


Assuntos
Infecções por Coronavirus , Vírus da Diarreia Epidêmica Suína , Doenças dos Suínos , Vírus da Gastroenterite Transmissível , Animais , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/veterinária , Deltacoronavirus , Dispositivos Lab-On-A-Chip , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Vírus da Diarreia Epidêmica Suína/genética , Impressão Tridimensional , Sensibilidade e Especificidade , Suínos , Doenças dos Suínos/diagnóstico , Vírus da Gastroenterite Transmissível/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA