Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 52(6): 1722-1731, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32720405

RESUMO

BACKGROUND: Segmental extent of infarction assessed by late gadolinium enhancement (LGE) imaging early post-ST-segment elevation myocardial infarction (STEMI) has utility in predicting left ventricular functional recovery. HYPOTHESIS: We hypothesized that segmental circumferential strain with displacement encoding with stimulated echoes (DENSE) would be a stronger predictor of infarct transmurality than feature-tracking strain, and noninferior to extracellular volume fraction (ECV). STUDY TYPE: Prospective. POPULATION: Fifty participants (mean ± SD, 59 ± 9 years, 40 [80%] male) underwent cardiac MRI on day 1 post-STEMI. FIELD-STRENGTH/SEQUENCES: 1.5T/cine, DENSE, T1 mapping, ECV, LGE. ASSESSMENT: Two observers assessed segmental percentage LGE extent, presence of microvascular obstruction (MVO), circumferential and radial strain with DENSE and feature-tracking, T1 relaxation times, and ECV. STATISTICAL TESTS: Normality was tested using the Shapiro-Wilk test. Skewed distributions were analyzed utilizing Mann-Whitney or Kruskal-Wallis tests and normal distributed data using independent t-tests. Diagnostic cutoff values were identified using the Youden index. The difference in area under the curve was compared using the z-statistic. RESULTS: Segmental circumferential strain with DENSE was associated with the extent of infarction ≥50% (AUC [95% CI], cutoff value = 0.9 [0.8, 0.9], -10%) similar to ECV (AUC = 0.8 [0.8, 0.9], 37%) (P = 0.117) and superior to feature-tracking circumferential strain (AUC = 0.7[0.7, 0.8], -19%) (P < 0.05). For the detection of segmental infarction ≥75%, circumferential strain with DENSE (AUC = 0.9 [0.8, 0.9], -10%) was noninferior to ECV (AUC = 0.8 [0.7, 0.9], 42%) (P = 0.132) and superior to feature-tracking (AUC = 0.7 [0.7, 0.8], -13%) (P < 0.05). For MVO detection, circumferential strain with DENSE (AUC = 0.8 [0.8, 0.9], -12%) was superior to ECV (AUC = 0.8 [0.7, 0.8] 34%) (P < 0.05) and feature-tracking (AUC = 0.7 [0.6, 0.7] -21%) (P < 0.05). DATA CONCLUSION: Circumferential strain with DENSE is a functional measure of infarct severity and may remove the need for gadolinium contrast agents in some circumstances. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 5 J. MAGN. RESON. IMAGING 2020;52:1722-1731.


Assuntos
Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio , Meios de Contraste , Gadolínio , Humanos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio , Valor Preditivo dos Testes , Estudos Prospectivos , Função Ventricular Esquerda
2.
Radiology ; 290(2): 329-337, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30457480

RESUMO

Purpose To investigate the prognostic value of circumferential left ventricular (LV) strain measured by using cardiac MRI for prediction of major adverse cardiac events (MACE) following an acute ST-segment-elevation myocardial infarction (STEMI). Materials and Methods Participants with acute STEMI were prospectively enrolled from May 11, 2011, to November 22, 2012. Cardiac MRI was performed at 1.5 T during the index hospitalization. Displacement encoding with stimulated echoes (DENSE) and feature tracking of cine cardiac MRI was used to assess circumferential LV strain. MACE that occurred after discharge were independently assessed by cardiologists blinded to the baseline observations. Results A total of 259 participants (mean age, 58 years ± 11 [standard deviation]; 198 men [mean age, 58 years ± 11] and 61 women [mean age, 58 years ± 12]) underwent cardiac MRI 2.2 days ± 1.9 after STEMI. Average infarct size was 18% ± 13 of LV mass and circumferential strain was -13% ± 3 (DENSE method) and -24% ± 7 (feature- tracking method). Fifty-one percent (131 of 259 participants) had presence of microvascular obstruction. During a median follow-up period of 4 years, 8% (21 of 259) experienced MACE. Area under the curve (AUC) for DENSE was different from that of feature tracking (AUC, 0.76 vs 0.62; P = .03). AUC for DENSE was similar to that of initial infarct size (P = .06) and extent of microvascular obstruction (P = .08). DENSE-derived strain provided incremental prognostic benefit over infarct size for prediction of MACE (hazard ratio, 1.3; P < .01). Conclusion Circumferential strain has independent prognostic importance in study participants with acute ST-segment-elevation myocardial infarction. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Kramer in this issue.


Assuntos
Cardiopatias , Ventrículos do Coração , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Feminino , Cardiopatias/epidemiologia , Cardiopatias/etiologia , Cardiopatias/mortalidade , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem
3.
J Cardiovasc Magn Reson ; 19(1): 21, 2017 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-28238284

RESUMO

BACKGROUND: Native T1 mapping is a cardiovascular magnetic resonance (CMR) technique that associates with markers of fibrosis and strain in hemodialysis patients. The reproducibility of T1 mapping in hemodialysis patients, prone to changes in fluid status, is unknown. Accurate quantification of myocardial fibrosis in this population has prognostic potential. METHODS: Using 3 Tesla CMR, we report the results of 1) the inter-study, inter-observer and intra-observer reproducibility of native T1 mapping in 10 hemodialysis patients; 2) inter-study reproducibility of left ventricular (LV) structure and function in 10 hemodialysis patients; 3) the agreement of native T1 map and native T1 phantom analyses between two centres in 20 hemodialysis patients; 4) the effect of changes in markers of fluid status on native T1 values in 10 hemodialysis patients. RESULTS: Inter-study, inter-observer and intra-observer variability of native T1 mapping were excellent with co-efficients of variation (CoV) of 0.7, 0.3 and 0.4% respectively. Inter-study CoV for LV structure and function were: LV mass = 1%; ejection fraction = 1.1%; LV end-diastolic volume = 5.2%; LV end-systolic volume = 5.6%. Inter-centre variability of analysis techniques were excellent with CoV for basal and mid-native T1 slices between 0.8-1.2%. Phantom analyses showed comparable native T1 times between centres, despite different scanners and acquisition sequences (centre 1: 1192.7 ± 7.5 ms, centre 2: 1205.5 ± 5 ms). For the 10 patients who underwent inter-study testing, change in body weight (Δweight) between scans correlated with change in LV end-diastolic volume (ΔLVEDV) (r = 0.682;P = 0.03) representing altered fluid status between scans. There were no correlations between change in native T1 between scans (ΔT1) and ΔLVEDV or Δweight (P > 0.6). Linear regression confirmed ΔT1 was unaffected by ΔLVEDV or Δweight (P > 0.59). CONCLUSIONS: Myocardial native T1 is reproducible in HD patients and unaffected by changes in fluid status at the levels we observed. Native T1 mapping is a potential imaging biomarker for myocardial fibrosis in patients with end-stage renal disease.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Falência Renal Crônica/terapia , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Diálise Renal , Adulto , Idoso , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Feminino , Fibrose , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/fisiopatologia , Modelos Lineares , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco , Reino Unido , Equilíbrio Hidroeletrolítico
4.
Kidney Int ; 90(4): 845-52, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27503805

RESUMO

Noninvasive quantification of myocardial fibrosis in end-stage renal disease is challenging. Gadolinium contrast agents previously used for cardiac magnetic resonance imaging (MRI) are contraindicated because of an association with nephrogenic systemic fibrosis. In other populations, increased myocardial native T1 times on cardiac MRI have been shown to be a surrogate marker of myocardial fibrosis. We applied this method to 33 incident hemodialysis patients and 28 age- and sex-matched healthy volunteers who underwent MRI at 3.0T. Native T1 relaxation times and feature tracking-derived global longitudinal strain as potential markers of fibrosis were compared and associated with cardiac biomarkers. Left ventricular mass indices were higher in the hemodialysis than the control group. Global, Septal and midseptal T1 times were all significantly higher in the hemodialysis group (global T1 hemodialysis 1171 ± 27 ms vs. 1154 ± 32 ms; septal T1 hemodialysis 1184 ± 29 ms vs. 1163 ± 30 ms; and midseptal T1 hemodialysis 1184 ± 34 ms vs. 1161 ± 29 ms). In the hemodialysis group, T1 times correlated with left ventricular mass indices. Septal T1 times correlated with troponin and electrocardiogram-corrected QT interval. The peak global longitudinal strain was significantly reduced in the hemodialysis group (hemodialysis -17.7±5.3% vs. -21.8±6.2%). For hemodialysis patients, the peak global longitudinal strain significantly correlated with left ventricular mass indices (R = 0.426), and a trend was seen for correlation with galectin-3, a biomarker of cardiac fibrosis. Thus, cardiac tissue properties of hemodialysis patients consistent with myocardial fibrosis can be determined noninvasively and associated with multiple structural and functional abnormalities.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Falência Renal Crônica/complicações , Miocárdio/patologia , Idoso , Biomarcadores/sangue , Biópsia , Cardiomiopatias/sangue , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Eletrocardiografia/métodos , Feminino , Fibrose , Gadolínio/administração & dosagem , Gadolínio/efeitos adversos , Galectina 3/sangue , Coração/fisiopatologia , Humanos , Falência Renal Crônica/terapia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Diálise Renal/efeitos adversos , Troponina T/sangue
5.
J Magn Reson Imaging ; 44(5): 1197-1205, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27104306

RESUMO

PURPOSE: To assess myocardial strain using cine displacement encoding with stimulated echoes (DENSE) using 1.5T and 3.0T MRI in healthy adults. MATERIALS AND METHODS: Healthy adults without any history of cardiovascular disease underwent magnetic resonance imaging (MRI) at 1.5T and 3.0T within 2 days. The MRI protocol included balanced steady-state free-precession (b-SSFP), 2D cine-echo planar imaging (EPI)-DENSE, and late gadolinium enhancement in subjects >45 years. Acquisitions were divided into six segments; global and segmental peak longitudinal and circumferential strain were derived and analyzed by field strength, age, and gender. RESULTS: In all, 89 volunteers (mean age 44.8 ± 18.0 years, range: 18-87 years) underwent MRI at 1.5T, and 88 of these subjects underwent MRI at 3.0T (1.4 ± 1.4 days between the scans). Compared with 3.0T, the magnitudes of global circumferential (-19.5 ± 2.6% vs. -18.47 ± 2.6%; P = 0.001) and longitudinal (-12.47 ± 3.2% vs. -10.53 ± 3.1%; P = 0.004) strain were greater at 1.5T. At 1.5T, longitudinal strain was greater in females than in males: -10.17 ± 3.4% vs. -13.67 ± 2.4%; P = 0.001. Similar observations occurred for circumferential strain at 1.5T (-18.72 ± 2.2% vs. -20.10 ± 2.7%; P = 0.014) and at 3.0T (-17.92 ± 1.8% vs. -19.1 ± 3.1%; P = 0.047). At 1.5T, longitudinal and circumferential strain were not associated with age after accounting for sex (longitudinal strain P = 0.178, circumferential strain P = 0.733). At 3.0T, longitudinal and circumferential strain were associated with age (P < 0.05). Longitudinal strain values were greater in the apico-septal, basal-lateral, and mid-lateral segments and circumferential strain in the inferior, infero-lateral, and antero-lateral LV segments. CONCLUSION: Myocardial strain parameters as revealed by cine-DENSE at different MRI field strengths were associated with myocardial region, age, and sex. J. Magn. Reson. Imaging 2016;44:1197-1205.


Assuntos
Envelhecimento/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Idoso , Anisotropia , Força Compressiva/fisiologia , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais , Estresse Mecânico , Resistência à Tração/fisiologia , Adulto Jovem
6.
J Magn Reson Imaging ; 44(3): 541-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26946323

RESUMO

PURPOSE: To use magnetic resonance imaging (MRI) at two field strengths to assess healthy adults' regional myocardial noncontrast (native) T1 relaxation time distribution, and global myocardial native T1 between sexes and across age groups. MATERIALS AND METHODS: In all, 84 healthy volunteers underwent MRI at 1.5T and 3.0T. T1 maps were acquired in three left ventricular short axis slices using an optimized modified Look-Locker inversion recovery investigational prototype sequence. T1 measurements in msec were calculated from 16 regions-of-interest, and a global T1 value from all evaluable segments per subject. Associations were assessed with a multivariate linear regression model. RESULTS: In total, 1297 (96.5%) segments were evaluable at 1.5T and 1263 (94.0%) segments at 3.0T. Native T1 was higher in septal than lateral myocardium (1.5T: 956.3 ± 44.4 vs. 939.2 ± 54.2 msec; P < 0.001; 3.0T: 1158.2 ± 45.9 vs. 1148.9 ± 56.9 msec; P = 0.012). Native T1 decreased with increasing age in females but not in males. Among lowest age tertile (<33 years) global native T1 was higher in females than in males at 1.5T (960.0 ± 20.3 vs. 931.5 ± 22.2 msec, respectively; P = 0.003) and 3.0T (1166.5 ± 19.7 vs. 1130.2 ± 20.6 msec; P < 0.001). No sex differences were observed in upper age tertile (≥55 years) at 1.5T (937.7 ± 25.4 vs. 934.7 ± 22.3 msec; P = 0.762) or 3.0T (1153.0 ± 30.0 vs. 1132.3 ± 23.5 msec; P = 0.056). Association of global native T1 to age (P = 0.002) and sex (P < 0.001) was independent of field strength and body size. CONCLUSION: In healthy adults, native T1 values are highest in the ventricular septum. Global native T1 was inversely associated with age in women, but not in men. J. Magn. Reson. Imaging 2016;44:541-548.


Assuntos
Envelhecimento/fisiologia , Técnicas de Imagem Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Caracteres Sexuais , Função Ventricular Esquerda/fisiologia , Envelhecimento/patologia , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
BMC Nephrol ; 15: 23, 2014 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-24484613

RESUMO

BACKGROUND: Measurement of renal perfusion is a crucial part of measuring kidney function. Arterial spin labelling magnetic resonance imaging (ASL MRI) is a non-invasive method of measuring renal perfusion using magnetised blood as endogenous contrast. We studied the reproducibility of ASL MRI in normal volunteers. METHODS: ASL MRI was performed in healthy volunteers on 2 occasions using a 3.0 Tesla MRI scanner with flow-sensitive alternating inversion recovery (FAIR) perfusion preparation with a steady state free precession (True-FISP) pulse sequence. Kidney volume was measured from the scanned images. Routine serum and urine biochemistry were measured prior to MRI scanning. RESULTS: 12 volunteers were recruited yielding 24 kidneys, with a mean participant age of 44.1 ± 14.6 years, blood pressure of 136/82 mmHg and chronic kidney disease epidemiology formula estimated glomerular filtration rate (CKD EPI eGFR) of 98.3 ± 15.1 ml/min/1.73 m2. Mean kidney volumes measured using the ellipsoid formula and voxel count method were 123.5 ± 25.5 cm3, and 156.7 ± 28.9 cm3 respectively. Mean kidney perfusion was 229 ± 41 ml/min/100 g and mean cortical perfusion was 327 ± 63 ml/min/100 g, with no significant differences between ASL MRIs. Mean absolute kidney perfusion calculated from kidney volume measured during the scan was 373 ± 71 ml/min. Bland Altman plots were constructed of the cortical and whole kidney perfusion measurements made at ASL MRIs 1 and 2. These showed good agreement between measurements, with a random distribution of means plotted against differences observed. The intra class correlation for cortical perfusion was 0.85, whilst the within subject coefficient of variance was 9.2%. The intra class correlation for whole kidney perfusion was 0.86, whilst the within subject coefficient of variance was 7.1%. CONCLUSIONS: ASL MRI at 3.0 Tesla provides a repeatable method of measuring renal perfusion in healthy subjects without the need for administration of exogenous compounds. We have established normal values for renal perfusion using ASL MRI in a cohort of healthy volunteers.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Rim/fisiologia , Angiografia por Ressonância Magnética/métodos , Artéria Renal/fisiologia , Circulação Renal/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Rim/irrigação sanguínea , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
8.
Endocr Connect ; 11(7)2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35700237

RESUMO

Objective: The aim of this study is to investigate the role of 3T-MRI in assessing musculoskeletal health in children and young people. Design: Bone, muscle and bone marrow imaging was performed in 161 healthy participants with a median age of 15.0 years (range, 8.0, 30.0). Methods: Detailed assessment of bone microarchitecture (constructive interference in the steady state (CISS) sequence, voxel size 0.2 × 0.2 × 0.4 mm3), bone geometry (T1-weighted turbo spin echo (TSE) sequence, voxel size 0.4 × 0.4 × 2 mm3) and bone marrow (1H-MRS, point resolved spectroscopy sequence (PRESS) (single voxel size 20 × 20 × 20 mm3) size and muscle adiposity (Dixon, voxel size 1.1 × 1.1 × 2 mm3). Results: There was an inverse association of apparent bone volume/total volume (appBV/TV) with age (r = -0.5, P < 0.0005). Cortical area, endosteal and periosteal circumferences and muscle cross-sectional area showed a positive association to age (r > 0.49, P < 0.0001). In those over 17 years of age, these parameters were also higher in males than females (P < 0.05). This sex difference was also evident for appBV/TV and bone marrow adiposity (BMA) in the older participants (P < 0.05). AppBV/TV showed a negative correlation with BMA (r = -0.22, P = 0.01) which also showed an association with muscle adiposity (r = 0.24, P = 0.04). Cortical geometric parameters were highly correlated with muscle area (r > 0.57, P < 0.01). Conclusions: In addition to providing deep insight into the normal relationships between bone, fat and muscle in young people, these novel data emphasize the role of MRI as a non-invasive method for performing a comprehensive and integrated assessment of musculoskeletal health in the growing skeleton.

9.
Sci Rep ; 9(1): 3239, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30824793

RESUMO

We analyzed feature-tracking derived circumferential and longitudinal strain in healthy volunteers who underwent cardiac magnetic resonance imaging (CMR) at 3.0 T. 88 healthy adults (44.6 ± 18.0 years old, 49% male), without prior cardiovascular disease, underwent CMR at 3.0 T including cine, and late gadolinium enhancement in subjects >45 years. LV functional analysis and feature-tracking strain analyses were carried out. Global strain had better reproducibility than segmental strain. There was a sex specific difference global longitudinal strain (mean ± SD, -18.48 ± 3.65% (male), -21.91 ± 3.01% (female), p < 0.001), but not global circumferential strain (mean ± SD, -25.41 ± 4.50% (male), -27.94 ± 3.48% (female), p = 0.643). There was no association of strain with ageing after accounting for sex for both global longitudinal and circumferential strain. Feature-tracking strain analysis is feasible at 3.0 T. Healthy female volunteers demonstrated higher magnitudes of global longitudinal strain when compared to male counterparts. Whilst global cine-strain has good reproducibility, segmental strain does not.


Assuntos
Saúde , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento por Ressonância Magnética , Adulto , Envelhecimento/fisiologia , Feminino , Humanos , Masculino , Miocárdio , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Caracteres Sexuais , Função Ventricular/fisiologia
10.
Eur J Radiol ; 112: 121-129, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777200

RESUMO

OBJECTIVE: We hypothesized that Displacement Encoding with Stimulated Echoes (DENSE) and feature-tracking derived circumferential strain would provide incremental prognostic value over the extent of infarction for recovery of segmental myocardial function. METHODS: Two hundred and sixty-one patients (mean age 59 years, 73% male) underwent MRI 2 days post-ST elevation myocardial infarction (STEMI) and 241 (92%) underwent repeat imaging 6 months later. The MRI protocol included cine, 2D-cine DENSE, T2 mapping and late enhancement. Wall motion scoring was assessed by 2-blinded observers and adjudicated by a third. (WMS: 1=normal, 2=hypokinetic, 3=akinetic, 4=dyskinetic). WMS improvement was defined as a decrease in WMS ≥ 1, and normalization where WMS = 1 on follow-up. Segmental circumferential strain was derived utilizing DENSE and feature-tracking. A generalized linear mixed model with random effect of subject was constructed and used to account for repeated sampling when investigating predictors of segmental myocardial improvement or normalization RESULTS: At baseline and follow-up, 1416 segments had evaluable data for all parameters. Circumferential strain by DENSE (p < 0.001) and feature-tracking (p < 0.001), extent of oedema (p < 0.001), infarct size (p < 0.001), and microvascular obstruction (p < 0.001) were associates of both improvement and normalization of WMS. Circumferential strain provided incremental predictive value even after accounting for infarct size, extent of oedema and microvascular obstruction, for segmental improvement (DENSE: odds ratio, 95% confidence intervals: 1.08 per -1% peak strain, 1.05-1.12, p < 0.001, feature-tracking: odds ratio, 95% confidence intervals: 1.05 per -1% peak strain, 1.03-1.07, p < 0.001) and segmental normalization (DENSE: 1.08 per -1% peak strain, 1.04-1.12, p < 0.001, feature-tracking: 1.06 per -1% peak strain, 1.04-1.08, p < 0.001). CONCLUSIONS: Circumferential strain provides incremental prognostic value over segmental infarct size in patients post STEMI for predicting segmental improvement or normalization by wall-motion scoring.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Miocárdio/patologia , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Estresse Fisiológico/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA