Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sci Rep ; 12(1): 5785, 2022 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-35388096

RESUMO

The study assessed chronic myocardial, coronary and systemic effects of intracoronary supersaturated oxygen (SSO2) therapy. Left anterior descending coronary arteries of 40 swine were stented and randomized to 90-min selective intracoronary infusion of SSO2 (pO2 760-1000 mmHg) or normoxemic saline. In 20 out of 40 animals, SSO2 delivery followed a 60-min balloon occlusion to induce myocardial infarction (MI). In both normal and MI models, intracoronary treatment with hyperoxemic SSO2 therapy showed no evidence of coronary thrombosis. There were no biologically relevant differences between treatments at either time point in regard to coronary intervention site healing and neointimal growth. No signs of any myocardial or systemic toxicity were observed after 7 or 30 days. A trend was observed toward reduced incidence of microscopic MI scars and reduced infarct size in histopathology, as well as toward better recovery of echocardiographically evaluated global and regional contractility at 30 days. No treatment related infarcts or thromboemboli were observed in the downstream organs.


Assuntos
Trombose Coronária , Infarto do Miocárdio , Animais , Vasos Coronários/patologia , Infarto do Miocárdio/patologia , Miocárdio/patologia , Oxigênio , Suínos
2.
Int J Cardiol ; 286: 21-28, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30967275

RESUMO

BACKGROUND: New generation bioresorbable scaffolds (BRS) promise to improve the outcomes of current generation BRS technologies by decreasing wall thickness while maintaining structural strength. This study aimed to compare the biomechanical behavior and vascular healing profile of a novel thin-walled (98 µm) sirolimus-eluting ultrahigh molecular weight BRS (Magnitude, Amaranth Medical) to the Absorb everolimus-eluting bioresorbable vascular scaffold (Abbott Vascular). METHODS AND RESULTS: In vitro biomechanical testing showed lower number of fractures on accelerated cycle testing over time (at 21K cycles = 20.0 [19.0-21.0] in Absorb versus 0.0 [0.0-1.0] in Magnitude-BRS). Either Magnitude (n = 43) or Absorb (n = 22) was implanted in 65 coronary segments of 22 swine. Scaffold strut's coverage was evaluated using serial optical coherence tomography (OCT) analysis. At 14 days, Magnitude-BRS demonstrated a higher percentage of embedded struts (97.7% [95.3, 100.0] compared to Absorb (57.2% [48.0, 76.0], p = 0.003) and lower percentage of uncovered struts (0.0% [0.0, 0.0] versus Absorb 5.5% [2.6, 7.7], p = 0.02). Also, it showed a lower percent late recoil (-1.02% [-4.11, 3.21] versus 4.42% [-1.10, 8.74], p = 0.04) at 28 days. Histopathology revealed comparable neointimal proliferation and vascular healing responses between two devices up to 180 days. CONCLUSION: A new generation thin walled (98-µm) Magnitude-BRS displayed a promising biomechanical behavior and strut healing profile compared to Absorb at the experimental level. This new generation BRS platform has the potential to improve the clinical outcomes shown by the current generation BRS.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Poliésteres , Sirolimo/farmacologia , Alicerces Teciduais , Animais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Modelos Animais de Doenças , Imunossupressores/farmacologia , Desenho de Prótese , Valores de Referência , Suínos , Tomografia de Coerência Óptica/métodos
3.
Circ Cardiovasc Interv ; 10(7)2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28701488

RESUMO

BACKGROUND: Mechanical strength of bioresorbable scaffolds (BRS) is highly dependent on strut dimensions and polymer features. To date, the successful development of thin-walled BRS has been challenging. We compared the biomechanical behavior and vascular healing profile of a novel thin-walled (115 µm) sirolimus-eluting ultrahigh molecular weight amorphous poly-l-lactic acid-based BRS (APTITUDE, Amaranth Medical [AMA]) to Absorb (bioresorbable vascular scaffold [BVS]) using different experimental models. METHODS AND RESULTS: In vitro biomechanical testing showed no fractures in the AMA-BRS when overexpanded 1.3 mm above nominal dilatation values (≈48%) and lower number of fractures on accelerated cycle testing over time (at 21 K cycles=20.0 [19.5-20.5] in BVS versus 4.0 [3.0-4.3] in AMA-BRS). In the healing response study, 35 AMA-BRS and 23 BVS were implanted in 58 coronary arteries of 23 swine and followed-up to 180 days. Scaffold strut healing was evaluated in vivo using weekly optical coherence tomography analysis. At 14 days, the AMA-BRS demonstrated a higher percentage of embedded struts (71.0% [47.6, 89.1] compared with BVS 40.3% [20.5, 63.2]; P=0.01). At 21 days, uncovered struts were still present in the BVS group (3.8% [2.1, 10.2]). Histopathology revealed lower area stenosis (AMA-BRS, 21.0±6.1% versus BVS 31.0±4.5%; P=0.002) in the AMA-BRS at 28 days. Neointimal thickness and inflammatory scores were comparable between both devices at 180 days. CONCLUSIONS: A new generation thinned wall BRS displayed a more favorable biomechanical behavior and strut healing profile compared with BVS in normal porcine coronary arteries. This novel BRS concept has the potential to improve the clinical outcomes of current generation BRS.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Vasos Coronários/patologia , Intervenção Coronária Percutânea/instrumentação , Poliésteres/química , Sirolimo/administração & dosagem , Cicatrização , Animais , Biópsia , Angiografia Coronária , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiopatologia , Teste de Materiais , Modelos Animais , Peso Molecular , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Falha de Prótese , Sus scrofa , Fatores de Tempo , Tomografia de Coerência Óptica
4.
Circ Cardiovasc Interv ; 9(10)2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27694138

RESUMO

BACKGROUND: Clinically available bioresorbable scaffolds (BRS) rely on polymer crystallinity to achieve mechanical strength resulting in limited overexpansion capabilities and structural integrity when exposed to high-loading conditions. We aimed to evaluate the biomechanical behavior and vascular healing profile of a novel, sirolimus-eluting, high-molecular-weight, amorphous poly-l-lactic acid-based BRS (Amaranth BRS). METHODS AND RESULTS: In vitro biomechanical testing was performed under static and cyclic conditions. A total of 99 devices (65 Amaranth BRS versus 34 Absorb bioresorbable vascular scaffold [BVS]) were implanted in 99 coronary arteries of 37 swine for pharmacokinetics and healing evaluation at various time points. In the Absorb BVS, the number of fractures per scaffold seen on light microscopy was 6.0 (5.0-10.5) when overexpanded 1.0 mm above nominal values (≈34%). No fractures were observed in the Amaranth BRS group at 1.3 mm above nominal values (≈48% overexpansion). The number of fractures was higher in the Absorb BVS on accelerated cycle testing over time (at 24K cycles=5.0 [5.0-9.0] Absorb BVS versus 0.0 [0.0-0.5] Amaranth BRS). Approximately 90% of sirolimus was found to be eluted by 90 days. Optical coherence tomography analysis demonstrated lower percentages of late scaffold recoil in the Amaranth BRS at 3 months (Amaranth BRS=-10±16.1% versus Absorb BVS=10.7±13.2%; P=0.004). Histopathology analysis revealed comparable levels of vascular healing and inflammatory responses between both BRSs up to 6 months. CONCLUSIONS: New-generation high-molecular-weight amorphous poly-l-lactic acid scaffolds have the potential to improve the clinical performance of BRS and provide the ideal platform for the future miniaturization of the technology.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/farmacocinética , Materiais Revestidos Biocompatíveis , Vasos Coronários/efeitos dos fármacos , Intervenção Coronária Percutânea/instrumentação , Poliésteres/química , Sirolimo/farmacocinética , Cicatrização/efeitos dos fármacos , Animais , Biópsia , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Teste de Materiais , Modelos Animais , Peso Molecular , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Falha de Prótese , Sirolimo/administração & dosagem , Suínos , Porco Miniatura , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA