Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Clin Chem ; 67(2): 404-414, 2021 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-33084854

RESUMO

BACKGROUND: It is unknown whether a positive serology result correlates with protective immunity against SARS-CoV-2. There are also concerns regarding the low positive predictive value of SARS-CoV-2 serology tests, especially when testing populations with low disease prevalence. METHODS: A neutralization assay was validated in a set of PCR-confirmed positive specimens and in a negative cohort. In addition, 9530 specimens were screened using the Diazyme SARS-CoV-2 IgG serology assay and all positive results (N = 164 individuals) were reanalyzed using the neutralization assay, the Roche total immunoglobin assay, and the Abbott IgG assay. The relationship between the magnitude of a positive SARS-CoV-2 serology result and neutralizing activity was determined. Neutralizing antibody titers (50% inhibitory dilution, ID50) were also longitudinally monitored in patients confirmed to have SARS-CoV-2 by PCR. RESULTS: The SARS-CoV-2 neutralization assay had a positive percentage agreement (PPA) of 96.6% with a SARS-CoV-2 PCR test and a negative percentage agreement (NPA) of 98.0% across 100 negative control individuals. ID50 neutralization titers positively correlated with all 3 clinical serology platforms. Longitudinal monitoring of hospitalized PCR-confirmed patients with COVID-19 demonstrated they made high neutralization titers against SARS-CoV-2. PPA between the Diazyme IgG assay alone and the neutralization assay was 50.6%, while combining the Diazyme IgG assay with either the Roche or Abbott platforms increased the PPA to 79.2 and 78.4%, respectively. CONCLUSIONS: These 3 clinical serology assays positively correlate with SARS-CoV-2 neutralization activity observed in patients with COVID-19. All patients confirmed SARS-CoV-2 positive by PCR develop neutralizing antibodies.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , SARS-CoV-2/imunologia , Adulto , Idoso , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/imunologia , Teste Sorológico para COVID-19/estatística & dados numéricos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Análise de Regressão , Estudos Retrospectivos , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/imunologia
3.
Am J Infect Control ; 49(4): 506-507, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33388312

RESUMO

Coronavirus Disease 2019 infections among healthcare workers were widely reported in China and Europe as the pandemic expanded to the United States. In order to examine the infection rate among these essential workers, we combined results of SARS-CoV-2 serology testing offered free to healthcare workers at two large San Diego health systems when the antibody assays first became available.


Assuntos
COVID-19/epidemiologia , Atenção à Saúde , Pessoal de Saúde , Exposição Ocupacional , SARS-CoV-2 , Soroconversão , California/epidemiologia , Humanos
4.
medRxiv ; 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33758902

RESUMO

Background: The severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has infected over 110 million individuals and led to 2.5 million deaths worldwide. As more individuals are vaccinated, the clinical performance and utility of SARS-CoV-2 serology platforms needs to be evaluated. Methods: The ability of four commercial SARS-CoV-2 serology platforms to detect previous infection or vaccination were evaluated using a cohort of 53 SARS-CoV-2 PCR-positive patients, 89 SARS-CoV-2-vaccinated healthcare workers (Pfizer or Moderna), and 127 SARS-CoV-2 negative patients. Serology results were compared to a cell based SARS-CoV-2 pseudovirus (PSV) neutralizing antibodies assay. Results: The Roche S-(spike) antibody and Diazyme neutralizing antibodies (NAbs) assays detected adaptive immune response in 100.0% and 90.1% of vaccinated individuals who received two-doses of vaccine (initial and booster), respectively. The Roche N-(nucleocapsid) antibody assay and Diazyme IgG assay did not detect adaptive immune response in vaccinated individuals. The Diazyme Nabs assay correlated with the PSV SARS-CoV-2 ID50 neutralization titers (R2= 0.70), while correlation of the Roche S-antibody assay was weaker (R2= 0.39). Median PSV SARS-CoV-2 ID50 titers more than doubled in vaccinated individuals who received two-doses of the Moderna vaccine (ID50: 597) compared to individuals that received a single dose (ID50: 284). Conclusions: The Roche S-antibody and Diazyme NAbs assays robustly detected adaptive immune responses in SARS-CoV-2 vaccinated individuals and SARS-CoV-2 infected individuals. The Diazyme NAbs assay strongly correlates with the PSV SARS-CoV-2 NAbs in vaccinated individuals. Understanding the reactivity of commercially available serology platforms is important when distinguishing vaccination response versus natural infection.

5.
J Appl Lab Med ; 6(5): 1109-1122, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34170314

RESUMO

BACKGROUND: The severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has infected over 110 million individuals and led to 2.5 million deaths worldwide. As more individuals are vaccinated, the clinical performance and utility of SARS-CoV-2 serology platforms needs to be evaluated. METHODS: The ability of 4 commercial SARS-CoV-2 serology platforms to detect previous infection or vaccination were evaluated using a cohort of 53 patients who were SARS-CoV-2 PCR positive, 89 SARS-CoV-2-vaccinated healthcare workers (Pfizer or Moderna), and 127 patients who were SARS-CoV-2 negative. Serology results were compared to a cell-based SARS-CoV-2 pseudovirus (PSV) neutralizing antibodies assay. RESULTS: The Roche S-(spike) antibody and Diazyme neutralizing antibodies (NAbs) assays detected adaptive immune response in 100.0% and 90.1% of vaccinated individuals who received 2 doses of vaccine (initial and booster), respectively. The Roche N-(nucleocapsid) antibody assay and Diazyme IgG assay did not detect adaptive immune response in vaccinated individuals. The Diazyme NAbs assay correlated with the PSV SARS-CoV-2 median infective dose (ID50) neutralization titers (R2 = 0.70), while correlation of the Roche S-antibody assay was weaker (R2 = 0.39). Median PSV SARS-CoV-2 ID50 titers more than doubled in vaccinated individuals who received 2 doses of the Moderna vaccine (ID50, 597) compared to individuals who received a single dose (ID50, 284). CONCLUSIONS: The Roche S-antibody and Diazyme NAbs assays robustly detected adaptive immune responses in SARS-CoV-2 vaccinated individuals and SARS-CoV-2 infected individuals. The Diazyme NAbs assay strongly correlates with the PSV SARS-CoV-2 NAbs in vaccinated individuals. Understanding the reactivity of commercially available serology platforms is important when distinguishing vaccination response versus natural infection.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Imunidade Humoral , Vacinação
6.
J Appl Lab Med ; 5(6): 1324-1336, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32766840

RESUMO

BACKGROUND: COVID-19 is caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a novel beta-coronavirus that is responsible for the 2019 coronavirus pandemic. Acute infections should be diagnosed by polymerase chain reaction (PCR) based tests, but serology tests can demonstrate previous exposure to the virus. METHODS: We compared the performance of the Diazyme, Roche, and Abbott SARS-CoV-2 serology assays using 179 negative participants to determine negative percentage agreement (NPA) and in 60 SARS-CoV-2 PCR-confirmed positive patients to determine positive percentage agreement (PPA) at 3 different time frames following a positive SARS-CoV-2 PCR result. RESULTS: At ≥15 days, the PPA (95% CI) was 100 (86.3-100)% for the Diazyme IgM/IgG panel, 96.0 (79.7-99.9)% for the Roche total Ig assay, and 100 (86.3-100)% for the Abbott IgG assay. The NPA (95% CI) was 98.3 (95.2-99.7)% for the Diazyme IgM/IgG panel, 99.4 (96.9-100)% for the Roche total Ig assay, and 98.9 (96.0-99.9)% for the Abbott IgG assay. When the Roche total Ig assay was combined with either the Diazyme IgM/IgG panel or the Abbott IgG assay, the positive predictive value was 100% while the negative predictive value remained greater than 99%. CONCLUSIONS: Our data demonstrates that the Diazyme, Roche, and Abbott SARS-CoV-2 serology assays have similar clinical performances. We demonstrated a low false-positive rate across all 3 platforms and observed that false positives observed on the Roche platform are unique compared to those observed on the Diazyme or Abbott assays. Using multiple platforms in tandem increases the PPVs, which is important when screening populations with low disease prevalence.


Assuntos
Anticorpos Antivirais/isolamento & purificação , Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/instrumentação , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Testes Sorológicos/instrumentação , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Betacoronavirus/imunologia , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/estatística & dados numéricos , Infecções por Coronavirus/sangue , Infecções por Coronavirus/imunologia , Infecções por Coronavirus/virologia , Reações Falso-Negativas , Reações Falso-Positivas , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina G/isolamento & purificação , Estudos Longitudinais , Pandemias , Pneumonia Viral/sangue , Pneumonia Viral/imunologia , Pneumonia Viral/virologia , Valor Preditivo dos Testes , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , SARS-CoV-2 , Testes Sorológicos/estatística & dados numéricos , Fatores de Tempo
7.
J Appl Lab Med ; 5(5): 908-920, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32428207

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is a novel beta-coronavirus that has recently emerged as the cause of the 2019 coronavirus pandemic (COVID-19). Polymerase chain reaction (PCR) based tests are optimal and recommended for the diagnosis of an acute SARS-CoV-2 infection. Serology tests for viral antibodies provide an important tool to diagnose previous exposure to the virus. Here we evaluate the analytical performance parameters of the Diazyme SARS-CoV-2 IgM/IgG serology assays and describe the kinetics of IgM and IgG seroconversion observed in patients with PCR-confirmed COVID-19 who were admitted to our hospital. METHODS: We validated the performance of the Diazyme assay in 235 presumed SARS-CoV-2 negative subjects to determine specificity. Subsequently, we evaluated the SARS-CoV-2 IgM and IgG seroconversion of 54 PCR-confirmed COVID-19 patients and determined sensitivity of the assay at three different timeframes. RESULT: Sensitivity and specificity for detecting seropositivity at ≥15 days following a positive SARS-CoV-2 PCR result, was 100.0% and 98.7% when assaying for the panel of IgM and IgG. The median time to seropositivity observed for a reactive IgM and IgG result from the date of a positive PCR was 5 days (IQR: 2.75-9 days) and 4 days (IQR: 2.75-6.75 days), respectively. CONCLUSIONS: Our data demonstrate that the Diazyme IgM/IgG assays are suited for the purpose of detecting SARS-CoV-2 IgG and IgM in patients with suspected SARS-CoV-2 infections. For the first time, we report longitudinal data showing the evolution of seroconversion for both IgG and IgM in a cohort of acutely ill patients in the United States. We also demonstrate a low false positive rate in patients who were presumed to be disease free.


Assuntos
Betacoronavirus , Infecções por Coronavirus , Imunoglobulina G , Imunoglobulina M , Pandemias , Pneumonia Viral , Soroconversão , Anticorpos Antivirais/sangue , Anticorpos Antivirais/isolamento & purificação , Betacoronavirus/imunologia , Betacoronavirus/isolamento & purificação , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/imunologia , Infecções por Coronavirus/virologia , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/isolamento & purificação , Imunoglobulina M/sangue , Imunoglobulina M/isolamento & purificação , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/métodos , Pneumonia Viral/diagnóstico , Pneumonia Viral/imunologia , Pneumonia Viral/virologia , SARS-CoV-2 , Sensibilidade e Especificidade
9.
J Autom Methods Manag Chem ; 2005: 8-25, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-18924721

RESUMO

MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA