Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pract Radiat Oncol ; 12(3): e232-e238, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34929401

RESUMO

PURPOSE: To develop a technology-enhanced education methodology with competency-based evaluation for radiation therapy treatment planning. The education program is designed for integration in the existing framework of Commission on Accreditation of Medical Physics Education Programs (CAMPEP) accredited medical physics residency programs. METHODS AND MATERIALS: This education program pairs an accessible, multi-institutional infrastructure with established medical education evaluation tools to modernize treatment planning education. This program includes 3 evaluation components: (1) competency-based evaluation, (2) inter- and intramodality comparison, and (3) learner feedback. For this study, synchronous bilateral breast cancer was selected to demonstrate a complex treatment site and nonstandardized technique. Additionally, an online study was made available to a public cohort of worldwide participants of certified Medical Dosimetrists and Medical Physicists to benchmark performance. Before evaluation, learners were given a disease site-specific education session on potential clinical treatment strategies. During the assessment, learners generated treatment plans in their institutional planning system under the direct observation of an expert evaluator. Qualitative proficiency was evaluated for all learners on a 5-point scale of graduated task independence. Quantitative dosimetry was compared between the learner cohort and public cohort. A feedback session provided learners context of multi-institutional experience through multimodality and technique comparison. After study completion, learners were provided a survey that was used to gauge their perception of the education program. RESULTS: In the public study, 34 participants submitted treatment plans. Across 3 CAMPEP-accredited residency programs, 6 learners participated in the education and evaluation program. All learners successfully completed treatment plans that met the dosimetric constraints described in the case study. All learners favorably reviewed the study either comprehensively or in specified domains. CONCLUSIONS: The competency-based education and evaluation program developed in this work has been incorporated in CAMPEP-accredited residency programs and is adaptable to other residency programs with minimal resource commitment.


Assuntos
Internato e Residência , Radioterapia (Especialidade) , Acreditação , Competência Clínica , Educação Baseada em Competências , Educação de Pós-Graduação em Medicina , Humanos
2.
Med Phys ; 48(9): 5549-5561, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34156719

RESUMO

PURPOSE: To advance fair and consistent comparisons of dose prediction methods for knowledge-based planning (KBP) in radiation therapy research. METHODS: We hosted OpenKBP, a 2020 AAPM Grand Challenge, and challenged participants to develop the best method for predicting the dose of contoured computed tomography (CT) images. The models were evaluated according to two separate scores: (a) dose score, which evaluates the full three-dimensional (3D) dose distributions, and (b) dose-volume histogram (DVH) score, which evaluates a set DVH metrics. We used these scores to quantify the quality of the models based on their out-of-sample predictions. To develop and test their models, participants were given the data of 340 patients who were treated for head-and-neck cancer with radiation therapy. The data were partitioned into training ( n = 200 ), validation ( n = 40 ), and testing ( n = 100 ) datasets. All participants performed training and validation with the corresponding datasets during the first (validation) phase of the Challenge. In the second (testing) phase, the participants used their model on the testing data to quantify the out-of-sample performance, which was hidden from participants and used to determine the final competition ranking. Participants also responded to a survey to summarize their models. RESULTS: The Challenge attracted 195 participants from 28 countries, and 73 of those participants formed 44 teams in the validation phase, which received a total of 1750 submissions. The testing phase garnered submissions from 28 of those teams, which represents 28 unique prediction methods. On average, over the course of the validation phase, participants improved the dose and DVH scores of their models by a factor of 2.7 and 5.7, respectively. In the testing phase one model achieved the best dose score (2.429) and DVH score (1.478), which were both significantly better than the dose score (2.564) and the DVH score (1.529) that was achieved by the runner-up models. Lastly, many of the top performing teams reported that they used generalizable techniques (e.g., ensembles) to achieve higher performance than their competition. CONCLUSION: OpenKBP is the first competition for knowledge-based planning research. The Challenge helped launch the first platform that enables researchers to compare KBP prediction methods fairly and consistently using a large open-source dataset and standardized metrics. OpenKBP has also democratized KBP research by making it accessible to everyone, which should help accelerate the progress of KBP research. The OpenKBP datasets are available publicly to help benchmark future KBP research.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Humanos , Bases de Conhecimento , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
3.
Med Phys ; 37(2): 505-15, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20229859

RESUMO

PURPOSE: To evaluate the utility of a new complexity metric, the modulation complexity score (MCS), in the treatment planning and quality assurance processes and to evaluate the relationship of the metric with deliverability. METHODS: A multisite (breast, rectum, prostate, prostate bed, lung, and head and neck) and site-specific (lung) dosimetric evaluation has been completed. The MCS was calculated for each beam and the overall treatment plan. A 2D diode array (MapCHECK, Sun Nuclear, Melbourne, FL) was used to acquire measurements for each beam. The measured and planned dose (PINNACLE3, Phillips, Madison, WI) was evaluated using different percent differences and distance to agreement (DTA) criteria (3%/ 3 mm and 2%/ 1 mm) and the relationship between the dosimetric results and complexity (as measured by the MCS or simple beam parameters) assessed. RESULTS: For the multisite analysis (243 plans total), the mean MCS scores for each treatment site were breast (0.92), rectum (0.858), prostate (0.837), prostate bed (0.652), lung (0.631), and head and neck (0.356). The MCS allowed for compilation of treatment site-specific statistics, which is useful for comparing different techniques, as well as for comparison of individual treatment plans with the typical complexity levels. For the six plans selected for dosimetry, the average diode percent pass rate was 98.7% (minimum of 96%) for 3%/3 mm evaluation criteria. The average difference in absolute dose measurement between the planned and measured dose was 1.7 cGy. The detailed lung analysis also showed excellent agreement between the measured and planned dose, as all beams had a diode percentage pass rate for 3%/3 mm criteria of greater than 95.9%, with an average pass rate of 99.0%. The average absolute maximum dose difference for the lung plans was 0.7 cGy. There was no direct correlation between the MCS and simple beam parameters which could be used as a surrogate for complexity level (i.e., number of segments or MU). An evaluation criterion of 2%/ 1 mm reliably allowed for the identification of beams that are dosimetrically robust. In this study we defined a robust beam or plan as one that maintained a diode percentage pass rate greater than 90% at 2%/ 1 mm, indicating delivery that was deemed accurate when compared to the planned dose, even under stricter evaluation criterion. MCS and MU threshold criteria were determined by defining a required specificity of 1.0. A MCS threshold of 0.8 allowed for identification of robust deliverability with a sensitivity of 0.36. In contrast, MU had a lower sensitivity of 0.23 for a threshold of 50 MU. CONCLUSIONS: The MCS allows for a quantitative assessment of plan complexity, on a fixed scale, that can be applied to all treatment sites and can provide more information related to dose delivery than simple beam parameters. This could prove useful throughout the entire treatment planning and QA process.


Assuntos
Algoritmos , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Canadá , Simulação por Computador , Relação Dose-Resposta à Radiação , Humanos , Modelos Estatísticos , Radiometria/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software
4.
Phys Med ; 72: 73-79, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32222642

RESUMO

We determine how prediction methods combine with optimization methods in two-stage knowledge-based planning (KBP) pipelines to produce radiation therapy treatment plans. We trained two dose prediction methods, a generative adversarial network (GAN) and a random forest (RF) with the same 130 treatment plans. The models were applied to 87 out-of-sample patients to create two sets of predicted dose distributions that were used as input to two optimization models. The first optimization model, inverse planning (IP), estimates weights for dose-objectives from a predicted dose distribution and generates new plans using conventional inverse planning. The second optimization model, dose mimicking (DM), minimizes the sum of one-sided quadratic penalties between the predictions and the generated plans using several dose-objectives. Altogether, four KBP pipelines (GAN-IP, GAN-DM, RF-IP, and RF-DM) were constructed and benchmarked against the corresponding clinical plans using clinical criteria; the error of both prediction methods was also evaluated. The best performing plans were GAN-IP plans, which satisfied the same criteria as their corresponding clinical plans (78%) more often than any other KBP pipeline. However, GAN did not necessarily provide the best prediction for the second-stage optimization models. Specifically, both the RF-IP and RF-DM plans satisfied the same criteria as the clinical plans 25% and 15% more often than GAN-DM plans (the worst performing plans), respectively. GAN predictions also had a higher mean absolute error (3.9 Gy) than those from RF (3.6 Gy). We find that state-of-the-art prediction methods when paired with different optimization algorithms, produce treatment plans with considerable variation in quality.


Assuntos
Bases de Conhecimento , Planejamento da Radioterapia Assistida por Computador/métodos , Automação , Dosagem Radioterapêutica
5.
Int J Radiat Oncol Biol Phys ; 107(4): 844-849, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32259570

RESUMO

PURPOSE: To design, develop, and evaluate an interactive simulation-based learning tool for treatment plan evaluation for radiation oncology and medical physics residents to address gaps in learning. METHODS AND MATERIALS: We first conducted a needs assessment for optimal learning tool design and case selection. Next, we generated a curated database of cases with clinically unacceptable treatment plans accessible through an in-house developed interactive web-based digital imaging and communications in medicine-radiation therapy viewer. We then developed an interactive user module that allows case selection, learner participation, and immediate feedback, including the final clinically acceptable plan. We pilot tested this case bank learning tool with current radiation oncology and medical physics residents within our institution. Afterward, residents completed an evaluation of tool design, content, and perceived impact on learning and provided suggestions for improvement. RESULTS: We generated 70 cases and learning modules for the case bank, encompassing various clinical sites, levels of difficulty, and classified errors. Residents positively endorsed the learning tool, including design, content, and perceived impact on learning. The learning tool's interactivity was perceived to provide increased educational value compared with other current learning methods. CONCLUSIONS: We created a high-fidelity simulation platform for treatment plan evaluation linked to a curated case bank. Evaluation of the pilot deployment demonstrated a benefit for resident learning and competency attainment. Future directions include external validation and expansion.


Assuntos
Educação Médica/métodos , Invenções , Aprendizagem , Planejamento da Radioterapia Assistida por Computador , Interface Usuário-Computador
6.
Med Phys ; 47(2): 297-306, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31675444

RESUMO

PURPOSE: To develop a knowledge-based automated planning pipeline that generates treatment plans without feature engineering, using deep neural network architectures for predicting three-dimensional (3D) dose. METHODS: Our knowledge-based automated planning (KBAP) pipeline consisted of a knowledge-based planning (KBP) method that predicts dose for a contoured computed tomography (CT) image followed by two optimization models that learn objective function weights and generate fluence-based plans, respectively. We developed a novel generative adversarial network (GAN)-based KBP approach, a 3D GAN model, which predicts dose for the full 3D CT image at once and accounts for correlations between adjacent CT slices. Baseline comparisons were made against two state-of-the-art deep learning-based KBP methods from the literature. We also developed an additional benchmark, a two-dimensional (2D) GAN model which predicts dose to each axial slice independently. For all models, we investigated the impact of multiplicatively scaling the predictions before optimization, such that the predicted dose distributions achieved all target clinical criteria. Each KBP model was trained on 130 previously delivered oropharyngeal treatment plans. Performance was tested on 87 out-of-sample previously delivered treatment plans. All KBAP plans were evaluated using clinical planning criteria and compared to their corresponding clinical plans. KBP prediction quality was assessed using dose-volume histogram (DVH) differences from the corresponding clinical plans. RESULTS: The best performing KBAP plans were generated using predictions from the 3D GAN model that were multiplicatively scaled. These plans satisfied 77% of all clinical criteria, compared to the clinical plans, which satisfied 67% of all criteria. In general, multiplicatively scaling predictions prior to optimization increased the fraction of clinical criteria satisfaction by 11% relative to the plans generated with nonscaled predictions. Additionally, these KBAP plans satisfied the same criteria as the clinical plans 84% and 8% more frequently as compared to the two benchmark methods, respectively. CONCLUSIONS: We developed the first knowledge-based automated planning framework using a 3D generative adversarial network for prediction. Our results, based on 217 oropharyngeal cancer treatment plans, demonstrated superior performance in satisfying clinical criteria and generated more realistic plans as compared to the previous state-of-the-art approaches.


Assuntos
Bases de Conhecimento , Planejamento da Radioterapia Assistida por Computador/métodos , Automação , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
7.
Phys Med ; 70: 145-152, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32023504

RESUMO

PURPOSE: Precision cancer medicine is dependent on accurate prediction of disease and treatment outcome, requiring integration of clinical, imaging and interventional knowledge. User controlled pipelines are capable of feature integration with varied levels of human interaction. In this work we present two pipelines designed to combine clinical, radiomic (quantified imaging), and RTx-omic (quantified radiation therapy (RT) plan) information for prediction of locoregional failure (LRF) in head and neck cancer (H&N). METHODS: Pipelines were designed to extract information and model patient outcomes based on clinical features, computed tomography (CT) imaging, and planned RT dose volumes. We predict H&N LRF using: 1) a highly user-driven pipeline that leverages modular design and machine learning for feature extraction and model development; and 2) a pipeline with minimal user input that utilizes deep learning convolutional neural networks to extract and combine CT imaging, RT dose and clinical features for model development. RESULTS: Clinical features with logistic regression in our highly user-driven pipeline had the highest precision recall area under the curve (PR-AUC) of 0.66 (0.33-0.93), where a PR-AUC = 0.11 is considered random. CONCLUSIONS: Our work demonstrates the potential to aggregate features from multiple specialties for conditional-outcome predictions using pipelines with varied levels of human interaction. Most importantly, our results provide insights into the importance of data curation and quality, as well as user, data and methodology bias awareness as it pertains to result interpretation in user controlled pipelines.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Aprendizado de Máquina , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Área Sob a Curva , Bases de Dados Factuais , Cabeça , Humanos , Modelos Logísticos , Pescoço , Imagens de Fantasmas , Prognóstico , Resultado do Tratamento
8.
Phys Med Biol ; 54(8): 2463-81, 2009 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-19336848

RESUMO

The dosimetry of small fields as used in stereotactic radiotherapy, radiosurgery and intensity-modulated radiation therapy can be challenging and inaccurate due to partial volume averaging effects and possible disruption of charged particle equilibrium. Consequently, there exists a need for an integrating, tissue equivalent dosimeter with high spatial resolution to avoid perturbing the radiation beam and artificially broadening the measured beam penumbra. In this work, radiochromic ferrous xylenol-orange (FX) and leuco crystal violet (LCV) micelle gels were used to measure relative dose factors (RDFs), percent depth dose profiles and relative lateral beam profiles of 6 MV x-ray pencil beams of diameter 28.1, 9.8 and 4.9 mm. The pencil beams were produced via stereotactic collimators mounted on a Varian 2100 EX linear accelerator. The gels were read using optical computed tomography (CT). Data sets were compared quantitatively with dosimetric measurements made with radiographic (Kodak EDR2) and radiochromic (GAFChromic EBT) film, respectively. Using a fast cone-beam optical CT scanner (Vista), corrections for diffusion in the FX gel data yielded RDFs that were comparable to those obtained by minimally diffusing LCV gels. Considering EBT film-measured RDF data as reference, cone-beam CT-scanned LCV gel data, corrected for scattered stray light, were found to be in agreement within 0.5% and -0.6% for the 9.8 and 4.9 mm diameter fields, respectively. The validity of the scattered stray light correction was confirmed by general agreement with RDF data obtained from the same LCV gel read out with a laser CT scanner that is less prone to the acceptance of scattered stray light. Percent depth dose profiles and lateral beam profiles were found to agree within experimental error for the FX gel (corrected for diffusion), LCV gel (corrected for scattered stray light), and EBT and EDR2 films. The results from this study reveal that a three-dimensional dosimetry method utilizing optical CT-scanned radiochromic gels allows for the acquisition of a self-consistent volumetric data set in a single exposure, with sufficient spatial resolution to accurately characterize small fields.


Assuntos
Radiometria/métodos , Corantes/química , Difusão , Géis , Violeta Genciana/química , Micelas , Octoxinol/química , Doses de Radiação , Sensibilidade e Especificidade , Tomografia Óptica
9.
Phys Med Biol ; 53(18): 5029-43, 2008 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-18723930

RESUMO

Ion chamber dosimetry requires a high degree of precision, at all steps within the dosimetric process, in order to ensure accurate dose measurements. This work presents a novel technique for ion chamber volume determination and quality assurance, using micro-computed tomography (micro-CT). Four nominally identical Exradin A1SL chambers (0.056 cm(3)) (Standard Imaging, WI, USA) were imaged using a micro-CT system (GE Locus, GE Healthcare, London, Ontario) and irradiated in a 6 MV x-ray reference field. Air volumes were calculated from the CT datasets using 3D analysis software (Microview 2.1.1, General Electric Healthcare, London, Ontario). Differences in the volumes of each chamber determined using micro-CT images agreed with differences in the ionization response within 1% for each chamber. Calibration coefficients were then compared through cross-calibration with a calibrated ion chamber and from the CT-measured volumes. The average ratio of these values was found to be 0.958 +/- 0.009 indicating good correlation. The results demonstrate the promise of using micro-CT imaging for the absolute volumetric characterization of ion chambers. The images have the potential to be an important clinical tool for quality assurance of ion chamber construction and integrity after routine clinical usage.


Assuntos
Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiometria/instrumentação , Radiometria/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Canadá , Desenho de Equipamento , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação
10.
Med Phys ; 45(7): 2875-2883, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29679492

RESUMO

PURPOSE: The purpose of this study was to automatically generate radiation therapy plans for oropharynx patients by combining knowledge-based planning (KBP) predictions with an inverse optimization (IO) pipeline. METHODS: We developed two KBP approaches, the bagging query (BQ) method and the generalized principal component analysis-based (gPCA) method, to predict achievable dose-volume histograms (DVHs). These approaches generalize existing methods by predicting physically feasible organ-at-risk (OAR) and target DVHs in sites with multiple targets. Using leave-one-out cross validation, we applied both models to a large dataset of 217 oropharynx patients. The predicted DVHs were input into an IO pipeline that generated treatment plans (BQ and gPCA plans) via an intermediate step that estimated objective function weights for an inverse planning model. The KBP predictions were compared to the clinical DVHs for benchmarking. To assess the complete pipeline, we compared the BQ and gPCA plans to both the predictions and clinical plans. To isolate the effect of the KBP predictions, we put clinical DVHs through the IO pipeline to produce clinical inverse optimized (CIO) plans. This approach also allowed us to estimate the complexity of the clinical plans. The BQ and gPCA plans were benchmarked against the CIO plans using DVH differences and clinical planning criteria. Iso-complexity plans (relative to CIO) were also generated and evaluated. RESULTS: The BQ method tended to predict that less dose is delivered than what was observed in the clinical plans while the gPCA predictions were more similar to clinical DVHs. Both populations of KBP predictions were reproduced with inverse plans to within a median DVH difference of 3 Gy. Clinical planning criteria for OARs were satisfied most frequently by the BQ plans (74.4%), by 6.3% points more than the clinical plans. Meanwhile, target criteria were satisfied most frequently by the gPCA plans (90.2%), and by 21.2% points more than clinical plans. However, once the complexity of the plans was constrained to that of the CIO plans, the performance of the BQ plans degraded significantly. In contrast, the gPCA plans still satisfied more clinical criteria than both the clinical and CIO plans, with the most notable improvement being in target criteria. CONCLUSION: Our automated pipeline can successfully use DVH predictions to generate high-quality plans without human intervention. Between the two KBP methods, gPCA plans tend to achieve comparable performance as clinical plans, even when controlling for plan complexity, whereas BQ plans tended to underperform.


Assuntos
Neoplasias Orofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Automação , Humanos , Órgãos em Risco/efeitos da radiação , Análise de Componente Principal , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos
11.
Phys Med Biol ; 63(10): 105004, 2018 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-29633957

RESUMO

We developed and evaluated a novel inverse optimization (IO) model to estimate objective function weights from clinical dose-volume histograms (DVHs). These weights were used to solve a treatment planning problem to generate 'inverse plans' that had similar DVHs to the original clinical DVHs. Our methodology was applied to 217 clinical head and neck cancer treatment plans that were previously delivered at Princess Margaret Cancer Centre in Canada. Inverse plan DVHs were compared to the clinical DVHs using objective function values, dose-volume differences, and frequency of clinical planning criteria satisfaction. Median differences between the clinical and inverse DVHs were within 1.1 Gy. For most structures, the difference in clinical planning criteria satisfaction between the clinical and inverse plans was at most 1.4%. For structures where the two plans differed by more than 1.4% in planning criteria satisfaction, the difference in average criterion violation was less than 0.5 Gy. Overall, the inverse plans were very similar to the clinical plans. Compared with a previous inverse optimization method from the literature, our new inverse plans typically satisfied the same or more clinical criteria, and had consistently lower fluence heterogeneity. Overall, this paper demonstrates that DVHs, which are essentially summary statistics, provide sufficient information to estimate objective function weights that result in high quality treatment plans. However, as with any summary statistic that compresses three-dimensional dose information, care must be taken to avoid generating plans with undesirable features such as hotspots; our computational results suggest that such undesirable spatial features were uncommon. Our IO-based approach can be integrated into the current clinical planning paradigm to better initialize the planning process and improve planning efficiency. It could also be embedded in a knowledge-based planning or adaptive radiation therapy framework to automatically generate a new plan given a predicted or updated target DVH, respectively.


Assuntos
Órgãos em Risco/efeitos da radiação , Neoplasias Orofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Canadá , Humanos , Dosagem Radioterapêutica
12.
Int J Radiat Oncol Biol Phys ; 102(4): 1107-1116, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29506884

RESUMO

PURPOSE: Distant metastasis (DM) is the main cause of death for patients with human papillomavirus (HPV)-related oropharyngeal cancers (OPCs); yet, there are few reliable predictors of DM in this disease. The role of quantitative imaging (ie, radiomic) analysis was examined to determine whether there are primary tumor features discernible on imaging studies that are associated with a higher risk of DM developing. METHODS AND MATERIALS: Radiation therapy planning computed tomography scans were retrieved for all nonmetastatic p16-positive OPC patients treated with radiation therapy or chemoradiation therapy at a single institution between 2005 and 2010. Radiomic biomarkers were derived from each gross tumor volume. The biomarkers included 4 representative radiomic features from tumor first-order statistics, shape, texture, and wavelet groups, as well as a combined 4-feature signature. Univariable Cox proportional hazards models for DM risk were identified. The discriminative performance of prognostic univariable and multivariable models was compared using the concordance index (C-index). Subgroup analyses were performed. RESULTS: There were 300 HPV-related OPC patients who were eligible for the analysis. A total of 36 DM events occurred within a median follow-up period of 5 years. On univariable analysis, top results included the 4 representative radiomic features (C-index, 0.670-0.686; P < .001), the radiomic signature (C-index, 0.670; P < .001), tumor stage (C-index, 0.633; P < .001), tumor diameter (C-index, 0.653; P < .001), and tumor volume (C-index, 0.674; P < .001), which demonstrated moderate discrimination of DM risk. Combined clinical-radiomic models yielded significantly improved performance (C-index, 0.701-0.714; P < .05). In subgroup analyses, the radiomic biomarkers consistently stratified patients for DM risk, particularly for those cohorts with greater risks (C-index, 0.663-0.796), such as patients with stage III disease. CONCLUSIONS: Radiomic biomarkers appear to classify DM risk for patients with nonmetastatic HPV-related OPC. Radiomic biomarkers could be used either alone or with other clinical characteristics in the assignment of DM risk in future HPV-related OPC clinical trials.


Assuntos
Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/patologia , Papillomaviridae/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias Orofaríngeas/virologia , Prognóstico , Estudos Retrospectivos , Risco , Tomografia Computadorizada por Raios X
13.
Phys Med Biol ; 62(15): 5926-5944, 2017 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-28486217

RESUMO

Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.


Assuntos
Biomimética , Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
14.
Int J Radiat Oncol Biol Phys ; 98(2): 428-437, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28366572

RESUMO

PURPOSE: To develop an entry-to-practice quality and safety competency profile for radiation oncology residency. METHODS AND MATERIALS: A comprehensive list of potential quality and safety competency items was generated from public and professional resources and interprofessional focus groups. Redundant or out-of-scope items were eliminated through investigator consensus. Remaining items were subjected to an international 2-round modified Delphi process involving experts in radiation oncology, radiation therapy, and medical physics. During Round 1, each item was scored independently on a 9-point Likert scale indicating appropriateness for inclusion in the competency profile. Items indistinctly ranked for inclusion or exclusion were re-evaluated through web conference discussion and reranked in Round 2. RESULTS: An initial 1211 items were compiled from 32 international sources and distilled to 105 unique potential quality and safety competency items. Fifteen of the 50 invited experts participated in round 1: 10 radiation oncologists, 4 radiation therapists, and 1 medical physicist from 13 centers in 5 countries. Round 1 rankings resulted in 80 items included, 1 item excluded, and 24 items indeterminate. Two areas emerged more prominently within the latter group: change management and human factors. Web conference with 5 participants resulted in 9 of these 24 items edited for content or clarity. In Round 2, 12 participants rescored all indeterminate items resulting in 10 items ranked for inclusion. The final 90 enabling competency items were organized into thematic groups consisting of 18 key competencies under headings adapted from Deming's System of Profound Knowledge. CONCLUSIONS: This quality and safety competency profile may inform minimum training standards for radiation oncology residency programs.


Assuntos
Competência Clínica , Técnica Delphi , Internato e Residência , Desenvolvimento de Programas , Radioterapia (Especialidade)/educação , Austrália , Canadá , Consenso , Currículo , Dinamarca , Ergonomia , Feminino , Grupos Focais , Física Médica , Humanos , Cooperação Internacional , Internato e Residência/normas , Masculino , Nova Zelândia , Segurança do Paciente , Guias de Prática Clínica como Assunto , Radioterapia (Especialidade)/normas , Radioterapia (Especialidade)/estatística & dados numéricos , Segurança , Reino Unido
15.
Med Phys ; 33(11): 3997-4004, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17153379

RESUMO

Accurate small-field dosimetry has become important with the use of multiple small fields in modern radiotherapy treatments such as IMRT and stereotactic radiosurgery. In this study, we investigate the response of a set of prototype plane-parallel ionization chambers, based upon the Exradin T11 chamber, with active volume diameters of 2, 4, 10, and 20 mm, exposed to 6 MV stereotactic radiotherapy x-ray fields. Our goal was to assess their usefulness for accurate small x-ray field dose measurements. The relative ionization response was measured in circular fields (0.5 to 4 cm diameter) as compared to a 10 x 10 cm2 reference field. A large discrepancy (approximately 40%) was found between the relative response in the smallest plane-parallel chamber and other small volume dosimeters (radiochromic film, micro-metal-oxide-semiconductor field-effect transistor and diode) used for comparison. Monte Carlo BEAMnrc simulations were used to simulate the experimental setup in order to investigate the cause of the under-response and to calculate appropriate correction factors that could be applied to experimental measurements. It was found that in small fields, the air cavity of these custom-made research chambers perturbed the secondary electron fluence profile significantly, resulting in decreased fluence within the active volume, which in turn produces a chamber under-response. It is demonstrated that a large correction to the p(fl) correction factor would be required to improve dosimetric accuracy in small fields, and that these factors could be derived using Monte Carlo simulations.


Assuntos
Radiometria/instrumentação , Raios X , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Artigo em Inglês | MEDLINE | ID: mdl-27050803

RESUMO

OBJECTIVES: Changes to the radiographic appearance of the jaws after head and neck radiotherapy have not been thoroughly characterized. This retrospective study examines changes to the appearance of the mandible on panoramic images following intensity-modulated radiotherapy (IMRT) and relates these changes to medical co-morbidities and radiation dose. STUDY DESIGN: The medical and dental charts, and panoramic images of 126 patients who received IMRT at the Princess Margaret Hospital between January 1, 2005, and December 31, 2008, were analyzed independently by three observers. RESULTS: Of the 126 patients, 75 (60%) had post-IMRT changes, as seen on panoramic images; most, 66 (88%), consisted of widened periodontal ligament space (WPLS). The median time to WPLS was 29 months after IMRT. Female gender and radiation dose correlated with decreased time to WPLS. CONCLUSIONS: These results indicate that WPLS is a common radiographic sequela after head and neck radiotherapy, underscoring its clinical significance as a reliable marker of irradiated bone. Furthermore, this type of WPLS needs to be differentiated from odontogenic inflammatory disease and cancer recurrence to avoid unnecessary treatment that may precipitate osteoradionecrosis.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Mandíbula/diagnóstico por imagem , Mandíbula/efeitos da radiação , Ligamento Periodontal/diagnóstico por imagem , Ligamento Periodontal/efeitos da radiação , Feminino , Humanos , Masculino , Radiografia Panorâmica , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Estudos Retrospectivos
17.
Head Neck ; 38 Suppl 1: E1102-9, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-26451876

RESUMO

BACKGROUND: The purpose of this article was to report outcomes of reirradiation for locoregionally recurrent nasopharyngeal carcinoma (NPC). METHODS: A retrospective review was conducted of all patients with locoregionally recurrent NPC who received reirradiation between 2001 and 2012. Overall survival (OS), local control, regional control, distant control, and Radiation Therapy Oncology Group (RTOG) grades 3 to 4 late toxicity were examined. RESULTS: A total of 42 recurrent cases treated with intensity-modulated radiotherapy (IMRT; 27 patients) or non-IMRT (stereotactic radiotherapy [RT], 12 patients; 3D conformal RT, 3 patients) were identified. Median time from initial RT to recurrence was 4.6 years. Hyperfractionation with 1.1 to 1.4 Gy/fraction twice daily to a total of 40 to 60 Gy was used in 27 IMRT and 5 non-IMRT patients. The remaining 10 patients received conventional fractionation 1.8 to 2.0 Gy/fraction to 50 to 60 Gy. Median follow-up was 3.0 years. The 3-year OS, local control, regional control, distant control, and late toxicity rates were 49%, 46%, 71%, 79%, and 37%, respectively. CONCLUSION: Reirradiation for recurrent NPC, delivered mostly with hyperfractionated IMRT, can result in durable disease control with acceptable late toxicity. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1102-E1109, 2016.


Assuntos
Carcinoma/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Recidiva Local de Neoplasia/radioterapia , Reirradiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Nasofaríngeo , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Estudos Retrospectivos
18.
Head Neck ; 38 Suppl 1: E2035-40, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-26828197

RESUMO

BACKGROUND: The purpose of this study was to determine the clinical outcomes of T4 laryngeal cancers. METHODS: T4 laryngeal cancers treated with curative intent from January 2003 to December 2010 were analyzed. Outcomes were evaluated in both primary radiotherapy (+/- chemotherapy) (RT/CRT) and primary surgery cohorts. RESULTS: Among the 65 primary RT/CRT and 42 primary surgery patients included, median follow-up was 4.4 years. There was a trend for improved locoregional control with surgery (74% vs 88%; p = .08). In the RT/CRT group the 3-year laryngectomy-free survival was 67%. The 2-year gastrostomy dependency rate was 23% with RT/CRT versus 6% with primary surgery (p = .07). Overall survival (OS) at 3 years was significantly lower in the RT/CRT versus primary surgery group (41% vs 70%; p < .01). CONCLUSION: Laryngeal preservation is achieved in over two thirds of patients with primary RT/CRT. Patients with low volume minimal cartilage involvement T4 disease may be best suited to RT/CRT. © 2016 Wiley Periodicals, Inc. Head Neck 38: E2035-E2040, 2016.


Assuntos
Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Laríngeas/diagnóstico , Laringectomia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radioterapia Adjuvante , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
19.
Int J Radiat Oncol Biol Phys ; 60(3): 994-1001, 2004 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-15465218

RESUMO

PURPOSE: The evolution of three-dimensional conformal radiation treatment has led to the use of multileaf collimators (MLCs) in intensity-modulated radiation therapy (IMRT) and other treatment techniques to increase the conformity of the dose distribution. A new quality assurance (QA) phantom has been designed to check the handling of MLC settings in treatment planning and delivery. METHODS AND MATERIALS: The phantom consists of a Perspex block with stepped edges that can be rotated in all planes. The design allows for the assessment of several MLC and micro-MLC types from various manufacturers, and is therefore applicable to most radiation therapy institutions employing MLCs. The phantom is computed tomography (CT) scanned as is a patient, and QA assessments can be made of field edge display for a variety of shapes and orientations on both radiation treatment planning systems (RTPS) and computed tomography simulators. RESULTS: The dimensions of the phantom were verified to be physically correct within an uncertainty range of 0-0.7 mm. Errors in leaf position larger than 1 mm were easily identified by multiple observers. CONCLUSIONS: The MLC geometry phantom is a useful tool in the QA of radiation therapy with application to RTPS, CT simulators, and virtual simulation packages with MLC display capabilities.


Assuntos
Imagens de Fantasmas/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/normas , Algoritmos , Calibragem , Desenho de Equipamento , Aceleradores de Partículas , Controle de Qualidade , Tomografia Computadorizada por Raios X
20.
Med Phys ; 31(9): 2443-8, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15487723

RESUMO

Helical tomotherapy (HT) is a novel radiotherapy technique that utilizes intensity modulated fan beams that deliver highly conformal dose distributions in a helical beam trajectory. The most significant limitation in dose delivery with a constant fan beam thickness (FBT) is the penumbra width of the dose distribution in the craniocaudal direction, which is equivalent to the FBT. We propose to employ a half-blocked fan beam at start and stop location to reduce the penumbra width by half. By opening the jaw slowly during the helical delivery until the desired FBT is achieved it is possible to create a sharper edge in the superior and inferior direction from the target. The technique was studied using a tomotherapy beam model implemented on a commercial treatment planning system (Theraplan Plus V3.0). It was demonstrated that the dose distribution delivered using a 25 mm fan beam can be improved significantly, to reduce the dose to normal structures located superiorly and inferiorly of the target. Dosimetry for this technique is straightforward down to a FBT of 15 mm and implementation should be simple as no changes in couch movement are required compared to a standard HT delivery. We conclude that the use of asymmetric collimated fan beams for the start and stop of the helical tomotherapeutic dose delivery has the potential of significantly improving the dose distribution in helical tomotherapy.


Assuntos
Algoritmos , Neoplasias Encefálicas/radioterapia , Análise de Falha de Equipamento/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Carga Corporal (Radioterapia) , Humanos , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA