Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Anesth Analg ; 136(3): 473-482, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729967

RESUMO

BACKGROUND: Prothrombin complex concentrates are an emerging "off-label" therapy to augment hemostasis after cardiopulmonary bypass (CPB), but data supporting their use for neonatal cardiac surgery are limited. METHODS: We retrospectively reviewed neonates undergoing open heart surgery with first-time sternotomy between May 2014 and December 2018 from a hospital electronic health record database. Neonates who received activated 4-factor prothrombin complex concentrate (a4FPCC) after CPB were propensity score matched (PSM) to neonates who did not receive a4FPCC (control group). The primary efficacy outcome was total volume (mL/kg) of blood products transfused after CPB, including the first 24 hours on the cardiovascular intensive care unit (CVICU). The primary safety outcome was the incidence of 7- and 30-day postoperative thromboembolism. Secondary outcomes included 24 hours postoperative chest tube output, time to extubation, duration of CVICU stay, duration of hospital stay, 30-day mortality, and incidence of acute kidney injury on postoperative day 3. We used linear regression modeling on PSM data for the primary efficacy outcome. For the primary safety outcome, we tested for differences using McNemar test on PSM data. For secondary outcomes, we used linear regression, Fisher exact test, or survival analyses as appropriate, with false discovery rate-adjusted P values. RESULTS: A total of 165 neonates were included in the final data analysis: 86 in the control group and 79 in the a4FPCC group. After PSM, there were 43 patients in the control group and 43 in the a4FPCC group. We found a statistically significant difference in mean total blood products transfused for the a4FPCC group (47.5 mL/kg) compared with the control group (63.7 mL/kg) for PSM patients (adjusted difference, 15.3; 95% CI, 29.4-1.3; P = .032). We did not find a statistically significant difference in 7- or 30-day thromboembolic rate, postoperative chest tube output, time to extubation, incidence of postoperative acute kidney injury (AKI), or 30-day mortality between the groups. The a4FPCC group had a significantly longer length of intensive care unit stay (32.9 vs 13.3 days; adjusted P = .049) and hospital stay (44.6 vs 24.1 days; adjusted P = .049) compared with the control group. CONCLUSIONS: We found that the use of a4FPCC as a hemostatic adjunct for post-CPB bleeding in neonatal cardiac surgery was associated with a decrease in mean total blood products transfused after CPB without an increased rate of 7- or 30-day postoperative thromboembolism. Our findings suggest that a4FPCCs can be considered as part of a hemostasis pathway for refractory bleeding in neonatal cardiac surgery.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Hemostáticos , Tromboembolia , Recém-Nascido , Humanos , Hemostáticos/efeitos adversos , Estudos Retrospectivos , Estudos de Coortes , Pontuação de Propensão , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Fator VIII , Fator VIIa , Hemostasia
2.
Anesth Analg ; 125(5): 1515-1523, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28678071

RESUMO

BACKGROUND: Incident reporting systems (IRSs) are important patient safety tools for identifying risks and opportunities for improvement. A major IRS limitation is underreporting of incidents. Perioperative anesthesia IRSs have been established at multiple pediatric institutions and a national pediatric anesthesia IRS for perioperative serious adverse events (SAEs) is maintained by Wake Up Safe (WUS), a patient safety organization dedicated to pediatric anesthesia quality improvement. A confidential, electronic, perioperative IRS was instituted at our tertiary children's hospital, which is a WUS member. The primary study aim was to increase the rate of incident reporting by anesthesiologists at our institution through a series of interventions. The secondary aim was to characterize our reporting behavior relative to national practice by referencing SAE data from WUS. METHODS: Perioperative adverse events reported over a 71-month period (November 2010 to September 2016) were categorized and the monthly reporting rates determined. Effects of 6 interventions targeted to increase the reporting rate were analyzed using control charts. Intervention 5 involved interviewing pediatric anesthesiologists to ascertain incident reporting barriers and motivators. A key driver diagram was developed and used to guide an improvement initiative. Incidents that fulfilled WUS criteria for SAEs were identified and categorized. SAE reporting rates over a 27-month period for 12 WUS member institutions were determined. RESULTS: 2689 perioperative adverse events were noted in 1980 of 72,384 anesthetics. Mean monthly adverse event case rate was 273 (95% confidence interval, 250-297) per 10,000 anesthetics. A subgroup involving 54,469 cases had 529 SAEs in 440 anesthetics; a mean monthly SAE case rate of 80 (95% confidence interval, 69-91) per 10,000 anesthetics. Cardiac, respiratory, and airway events predominated. Relative to WUS peer members, our institution is a high-reporting outlier. The rate of incident reporting per 10,000 anesthetics was sustainably increased from 149 ± 35 to 387 ± 73 (mean ± SD) after implementing mandatory IRS data entry and Intervention 5 quality improvement initiative. Barriers to reporting included concern for punitive repercussions, feelings of incompetence, poor education about what constitutes an event, lack of feedback, and the perception that reporting had no value. These were addressed by IRS education, cultivation of a culture of safety where reporting is encouraged, reporter feedback, and better inclusion of anesthesiologists in patient safety work. CONCLUSIONS: Electronic mandatory IRS data entry and an initiative to understand and address reporting barriers and motivators were associated with sustained increases in the adverse event reporting rate. These strategies to minimize underreporting enhance IRS value for learning and may be generalizable.


Assuntos
Sistemas de Notificação de Reações Adversas a Medicamentos , Anestesia/efeitos adversos , Anestesiologistas , Anestésicos/efeitos adversos , Hospitais Pediátricos , Notificação de Abuso , Centros de Atenção Terciária , Anestesiologistas/psicologia , Atitude do Pessoal de Saúde , Bases de Dados Factuais , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Motivação , Segurança do Paciente , Avaliação de Programas e Projetos de Saúde , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Medição de Risco , Fatores de Risco , Fatores de Tempo
3.
Paediatr Anaesth ; 26(10): 976-86, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27402424

RESUMO

BACKGROUND: Combined heart and liver transplantation (CHLT) in the pediatric population involves a complex group of patients, many of whom have palliated congenital heart disease (CHD) involving single ventricle physiology. OBJECTIVE: The purpose of this study was to describe the perioperative management of pediatric patients undergoing CHLT at a single institution and to identify management strategies that may be used to optimize perioperative care. METHODS: We did a retrospective database review of all patients receiving CHLT at a children's hospital between 2006 and 2014. Information collected included preoperative characteristics, intraoperative management, blood transfusions, and postoperative morbidity and mortality. RESULTS: Five pediatric CHLTs were performed over an 8-year period. All patients had a history of complex CHD with multiple sternotomies, three of whom had failing Fontan physiology. Patient age ranged from 7 to 23 years and weight from 29.5 to 68.5 kg. All CHLTs were performed using an en-bloc technique where both the donor heart and liver were implanted together on cardiopulmonary bypass (CPB). The median operating room time was 14.25 h, median CPB time was 3.58 h, and median donor ischemia time was 4.13 h. Patients separated from CPB on dopamine, epinephrine, and milrinone infusions and two required inhaled nitric oxide. All patients received a massive intraoperative blood transfusion post CPB with amounts ranging from one to three times the patient's estimated blood volume. The patient who required the most transfusions was in decompensated heart and liver failure preoperatively. Four of the five patients received an antifibrinolytic agent as well as a procoagulant (prothrombin complex concentrate or recombinant activated Factor VII) to assist with hemostasis. There were no 30-day thromboembolic events detected. Postoperatively the median length of mechanical ventilation, ICU stay and stay to hospital discharge was 4, 8, and 37 days, respectively. All patients are alive and free from allograft rejection at this time. CONCLUSION: Combined heart and liver transplantation in the pediatric population involves a complex group of patients with unique perioperative challenges. Successful management starts with thorough preoperative planning and communication and involves strategies to deal with massive intraoperative hemorrhage and coagulopathy in addition to protecting and supporting the transplanted heart and liver and meticulous surgical technique. An integrated multidisciplinary team approach is the cornerstone for successful outcomes.


Assuntos
Cardiopatias Congênitas/cirurgia , Transplante de Coração/métodos , Transplante de Fígado/métodos , Assistência Perioperatória/métodos , Adolescente , Adulto , Transfusão de Sangue/estatística & dados numéricos , Criança , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
4.
Anesth Analg ; 119(3): 595-600, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24806138

RESUMO

BACKGROUND: Accurate measurement of intraoperative blood loss is an important clinical variable in managing fluid resuscitation and avoiding unnecessary transfusion of blood products. In this study, we measured surgical blood loss using a tablet computer programmed with a unique algorithm modeled after facial recognition technology. The aim of the study was to assess the accuracy and performance of the system on surgical laparotomy sponges in vitro. METHODS: Whole blood samples of premeasured hemoglobin (Hb) and volume were reconstituted from units of human packed red blood cells and plasma and distributed across surgical laparotomy sponges. Normal saline was added to simulate the presence of varying levels of hemodilution and/or irrigation use. Soaked sponges from 4 different manufacturers were scanned using the Triton System with Feature Extraction Technology (Gauss Surgical, Inc., Palo Alto, CA) under 3 different ambient light conditions in an operating room. Accuracy of Hb loss measurement was evaluated relative to the premeasured values using linear regression and Bland-Altman analysis. Correlations between studied variables and measurement bias were analyzed using nonparametric tests. RESULTS: The overall mean percent error for measure of Hb loss for the Triton System was 12.3% (95% confidence interval [CI], 8.2%-16.4%). A strong positive linear correlation between the premeasured and actual Hb masses was noted across the full range of intraoperative lighting conditions, including (A) high (r = 0.95 [95% CI, 0.93-0.96]), (B) medium (r = 0.94 [95% CI, 0.93-0.96]), and (C) low (r = 0.90 [95% CI, 0.87-0.93]) mean ambient light intensity. Bland-Altman analysis revealed a bias of 0.01 g [95% CI, -0.03 to 0.06 g] of Hb per sponge between the 2 measures. The corresponding lower and upper limits of agreement were -1.16 g (95% CI, -1.21 to -1.12 g) per sponge and 1.19 g (95% CI, 1.15-1.24 g) per sponge, respectively. Measurement bias of estimated blood loss and Hb mass using the new system were not associated with the volume of saline used to reconstitute the samples (P = 0.506 and P = 0.469, respectively), suggesting that the system is robust under a wide range of sponge saturation conditions. CONCLUSIONS: Mobile blood loss monitoring using the Triton system is accurate in assessing Hb mass on surgical sponges across a range of ambient light conditions, sponge saturation, saline contamination, and initial blood Hb. Utilization of this tool could significantly improve the accuracy of blood loss estimates.


Assuntos
Hemoglobinometria/instrumentação , Hemoglobinas/análise , Monitorização Intraoperatória/instrumentação , Perda Sanguínea Cirúrgica , Intervalos de Confiança , Hemoglobinometria/métodos , Humanos , Laparotomia/instrumentação , Iluminação , Monitorização Intraoperatória/métodos , Reprodutibilidade dos Testes , Tampões de Gaze Cirúrgicos
5.
J Appl Physiol (1985) ; 94(3): 1054-62, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12571135

RESUMO

Prolonged fetal tracheal occlusion (TO) accelerates lung growth but leads to loss of alveolar epithelial type II (AE2) cells. In contrast, temporary TO leads to recovery of AE2 cells and their ability to produce surfactant. The aim of this study was to determine the effects of temporary TO in fetal sheep with lung hypoplasia on postnatal lung function, structure, and surfactant protein mRNA expression. Diaphragmatic hernia (DH) was created in 22 fetal sheep at 65 days of gestation. TO was performed between 110 days of gestation and full term (DH/TO, n = 7) and between 110 and 130 days of gestation (DH/TO+R, n = 6). Sham-operated fetuses (n = 11) served as controls. Lambs were delivered at approximately 139 days of gestation, and blood gas tensions were monitored over a 2-h resuscitation period. Temporary TO increased growth of the hypoplastic lung and restored surfactant protein mRNA expression and AE2 cell density but did not improve respiratory function above that of animals that underwent prolonged TO; DH/TO and DH/TO+R lambs were hypoxic and hypercapnic compared with Sham animals. Lung compliance remained low in DH/TO+R lambs, most likely as a consequence of the persistent increase in alveolar wall thickness in these animals.


Assuntos
Animais Recém-Nascidos/fisiologia , Feto/fisiologia , Pulmão/anormalidades , Pulmão/fisiologia , Traqueia/fisiologia , Animais , Gasometria , Northern Blotting , Água Corporal/fisiologia , Feminino , Peso Fetal/fisiologia , Regulação da Expressão Gênica/fisiologia , Hérnia Diafragmática/fisiopatologia , Imuno-Histoquímica , Pulmão/embriologia , Complacência Pulmonar/fisiologia , Tamanho do Órgão/fisiologia , Gravidez , Proteína B Associada a Surfactante Pulmonar/biossíntese , Proteína B Associada a Surfactante Pulmonar/genética , RNA Mensageiro/biossíntese , Testes de Função Respiratória , Ressuscitação , Ovinos , Fixação de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA