1.
J Prosthodont ; 27(2): 162-168, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27037795

RESUMO

PURPOSE: To investigate the retention loads of differently fabricated secondary telescopic polyetheretherketone (PEEK) crowns on cobalt-chromium primary crowns with different tapers. MATERIALS AND METHODS: Cobalt-chromium primary crowns with 0°, 1°, and 2° tapers were constructed, milled, and sintered. Corresponding secondary crowns were fabricated by milling, pressing from pellets, and pressing from granules. For these nine test groups, the pull-off tests of each crown combination were performed 20 times, and the retention loads were measured (Zwick 1445, 50 mm/min). Data were analyzed using linear regression, covariance analysis, mixed models, Kruskal-Wallis, and Mann-Whitney U-test, together with the Benferroni-Holm correction. RESULTS: The mixed models covariance analysis reinforced stable retention load values (p = 0.162) for each single test sequence. There was no interaction between the groups and the separation cycles (p = 0.179). Milled secondary crowns with 0° showed the lowest mean retention load values compared to all tested groups (p = 0.003) followed by those pressed form pellets with 1°. Regarding the different tapers, no effect of manufacturing method on the results was observed within 1° and 2° groups (p = 0.540; p = 0.052); however, among the 0° groups, the milled ones showed significantly the lowest retention load values (p = 0.002). Among the manufacturing methods, both pressed groups showed no impact of taper on the retention load values (p > 0.324 and p > 0.123, respectively), whereas among the milled secondary crowns, the 0° taper showed significantly lower retention load values than the 1° and 2° taper (p < 0.002). CONCLUSION: Based on these results, telescopic crowns made of PEEK seem to show stable retention load values for each test sequence; however, data with thermo-mechanical aging are still required. In addition, further developments in CAD/CAM manufacturing of PEEK materials for telescopic crowns are warranted, especially for 0°.


Assuntos
Ligas de Cromo , Coroas , Materiais Dentários , Planejamento de Prótese Dentária , Cetonas , Polietilenoglicóis , Benzofenonas , Coroas/efeitos adversos , Planejamento de Prótese Dentária/efeitos adversos , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Polímeros
2.
J Biomol Screen ; 13(1): 40-53, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18227225

RESUMO

High-content screening, typically defined as automated fluorescence microscopy combined with image analysis, is now well established as a means to study test compound effects in cellular disease-modeling systems. In this work, the authors establish several high-content screening assays in the 384-well format to measure the activation of the CC-type chemokine receptors 2B and 3 (CCR2B, CCR3). As a cellular model system, the authors use Chinese hamster ovary cells, stably transfected with 1 of the respective receptors. They characterize receptor stimulation by human monocyte chemoattractant protein-1 for CCR2B and by human eotaxin-1 for CCR3: Receptor internalization and receptor-induced phosphorylation of ERK1/2 (pERK) were quantified using fluorescence imaging and image analysis. The 4 assay formats were robust, displayed little day-to-day variability, and delivered good Z' statistics for both CCRs. For each of the 2 receptors, the authors evaluated the potency of inhibitory compounds in the internalization format and the pERK assay and compared the results with those from other assays (ligand displacement binding, Ca(2+) mobilization, guanosine triphosphate exchange, chemotaxis). Both physiological agonists and test compounds differed significantly with respect to potencies and efficacies in the various profiling assays. The diverse assay formats delivered partially overlapping and partially complementary information, enabling the authors to reduce the probability of test compound-related technology artifacts and to specify the mode of action for individual test compounds. Transfer of the high-content screening format to a fully automated medium-throughput screening platform for CCR3 enabled the profiling of large compound numbers with respect to G protein signaling and possible tolerance-inducing liabilities.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Receptores de Quimiocinas/efeitos dos fármacos , Animais , Células CHO , Quimiocina CCL11/farmacologia , Quimiocina CCL2/farmacologia , Cricetinae , Cricetulus , Humanos , Técnicas In Vitro , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Receptores CCR2/efeitos dos fármacos , Receptores CCR2/genética , Receptores CCR2/metabolismo , Receptores CCR3/agonistas , Receptores CCR3/efeitos dos fármacos , Receptores CCR3/genética , Receptores CCR3/metabolismo , Receptores de Quimiocinas/genética , Receptores de Quimiocinas/metabolismo , Proteínas Recombinantes/efeitos dos fármacos , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Transfecção
3.
Comb Chem High Throughput Screen ; 9(5): 339-50, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16787147

RESUMO

High Content Screening (HCS), a combination of fluorescence microscopic imaging and automated image analysis, has become a frequently applied tool to study test compound effects in cellular disease-modelling systems. In this work, we established a medium to high throughput HCS assay in the 384-well format to measure cellular type I phosphoinositide 3 kinase (PI3K) activity. Type I PI3K is involved in several intracellular pathways such as cell survival, growth and differentiation as well as immunological responses. As a cellular model system we used Chinese Hamster Ovary (CHO) cells that had been stably transfected with human insulin receptor (hIR) and an AKT1-enhanced green fluorescent protein (EGFP) fusion construct. Upon stimulation of the hIR with insulin-like growth factor-1 (IGF-1), PI3K was activated to phosphorylate phosphatidylinositol (PtdIns)-4,5-bisphosphate at the 3-position, resulting in the recruitment of AKT1-EGFP to the plasma membrane. The AKT1-EGFP redistribution assay was robust and displayed little day-to-day variability, the quantification of the fluorescence intensity associated with plasma membrane spots delivered good Z' statistics. A novel format of compound dose-response testing was employed using serial dilutions of test compounds across consecutive microtiter plates (MTPs). The dose response testing of a PI3K inhibitor series provided reproducible IC50 values. The profiling of the redistribution assay with isoform-selective inhibitors indicates that PI3Kalpha is the main isoform activated in the CHO host cells after IGF-1 stimulation. Toxic compound side effects could be determined using automated image analysis. We conclude that the AKT1-EGFP redistribution assay represents a solid medium/high throughput screening (MTS/HTS) format to determine the cellular activity of PI3K inhibitors under conditions of growth factor stimulation.


Assuntos
Bioensaio/métodos , Membrana Celular/efeitos dos fármacos , Avaliação Pré-Clínica de Medicamentos/métodos , Inibidores Enzimáticos/farmacologia , Inibidores de Fosfoinositídeo-3 Quinase , Proteínas Proto-Oncogênicas c-akt/metabolismo , Animais , Células CHO , Membrana Celular/metabolismo , Membrana Celular/ultraestrutura , Células Cultivadas , Cricetinae , Relação Dose-Resposta a Droga , Feminino , Proteínas de Fluorescência Verde/química , Humanos , Fator de Crescimento Insulin-Like I/metabolismo , Microscopia de Fluorescência , Fosfatidilinositol 3-Quinases/metabolismo , Fosfatos de Fosfatidilinositol/metabolismo , Receptor de Insulina/metabolismo , Fatores de Tempo
4.
Dent Mater J ; 35(4): 594-600, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27477224

RESUMO

To assess the retention force between primary and secondary PEEK crowns made by different fabrication methods. Primary crowns with different tapers (0°, 1°, and 2°) were fabricated and secondary crowns that were either milled from breCam BioHPP blanks, pressed from pellets (BioHPP Pellet) or granules (BioHPP Granulat) were produced. Each specimen was measured 20 times in a pulloff-test and results were analyzed using 2-/1-way ANOVA and linear regression analyses (p<0.05). Within 0° tapered crowns milled secondary crowns showed lower retention forces compared to pressed pellet crowns. Crowns with a 1° taper, however, showed no impact of the fabrication method on retention force. At a 2° taper, granular pressed crowns displayed lower values than their milled counterparts. Within the milled group, a 0° taper showed lower retention values than the higher tapers, whereas in the pressed groups, no impact of taper angle on retention force was found.


Assuntos
Coroas , Retenção em Prótese Dentária , Análise do Estresse Dentário , Humanos
5.
Materials (Basel) ; 9(3)2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-28773311

RESUMO

In prosthetic dentistry, double crown systems have proved their suitability as retainers for removable partial dentures. However, investigations in this context, regarding polyetheretherketone, are scarce. Therefore, the aim of this study was to test the retention force (RF) between polyetheretherketone (PEEK) primary and cobalt-chromium (CoCr), zirconia (ZrO2) and galvanic (GAL) secondary crowns with three different tapers. Primary PEEK-crowns were milled with the tapers 0°, 1°, and 2° (n = 10/taper, respectively). Afterwards, 90 secondary crowns were fabricated: (i) 30 CoCr-crowns milled from Ceramill Sintron (AmannGirrbach, Koblach, Austria) (n = 10/taper), (ii) 30 ZrO2-crowns milled from Ceramill ZI (AmannGirrbach, Koblach, Austria) (n = 10/taper), and (iii) 30 GAL-crowns made using electroforming (n = 10/taper). RF was measured in a pull-off test (20 pull-offs/specimen) and data were analyzed using 2-/1-way Analysis of Variance (ANOVA) followed by the Tukey-Honestly Significant Difference (HSD) post hoc test and linear regression analyses (p < 0.05). The measured mean RF values ranged between 9.6 and 38.2 N. With regard to the 0°, 1°, and 2° tapered crowns, no statistically significant differences between CoCr and ZrO2 were observed (p > 0.141). At 0° taper, no differences in retention forces between GAL, CrCr, and ZrO2 crowns were found (p = 0.075). However, at 1° and 2° taper, lower RF for GAL-crowns were observed (p < 0.009, p < 0.001, respectively). According to this laboratory study, PEEK might be a suitable material for primary crowns, regardless of the taper and the material of secondary crown. Long-term results, however, are still necessary.

6.
Materials (Basel) ; 9(5)2016 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-28773477

RESUMO

This study aimed to examine and compare the retention load values (RL) of different telescopic crown assemblies (Y-TZP and CoCr primary crowns with electroformed and Y-TZP secondary crowns each) with three different taper angles (0°, 1° and 2°). Thirty Y-TZP primary crowns with electroformed gold copings (Z/G group) and Y-TZP secondary crowns (Z/Z group) and 30 CoCr primary crowns with electroformed gold copings (C/G group) and Y-TZP secondary crowns (C/Z group), each with taper angles of 0°, 1° and 2°, were fabricated, respectively. With the exception of the electroformed gold copings, all specimens were Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM)-milled, then sintered and afterwards manually adapted. In order to stabilize the gold copings, they were fixed in a tertiary structure. The secondary crowns were constructed with a hook, which ensured self-alignment with an upper chain. Afterwards, 20 pull-off test cycles were performed in a universal testing machine under artificial saliva and after weighing the secondary crowns with a 5 kg object for 20 s. Data were analyzed by one-way and two-way Analysis of Variance (ANOVA). C/Z with 1° showed higher (p = 0.009) RL than 0° and 2° tapers. C/G at 1° also showed higher (p = 0.001) RL than at tapers of 0° and 2°. Z/G and C/G at 0° showed lower RL than Z/Z and C/Z (p < 0.001). Primary crowns had no impact on the 0° group. Z/G showed lower RL as compared to C/Z within the 1° group (p = 0.007) and Z/Z in the 2° group (p = 0.006). The primary crown material had no influence on RL. Electroformed copings showed lower RL. Further investigations for 1° as well as for the long-term performance after thermomechanical aging are necessary.

7.
Materials (Basel) ; 9(11)2016 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-28774027

RESUMO

This study investigates the retention load (RL) between ZrO2 primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO2 crowns were fabricated with three different tapers: 0°, 1°, and 2° (n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis (p < 0.05). Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

8.
Comb Chem High Throughput Screen ; 7(1): 45-54, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14965260

RESUMO

Time-resolved fluorescence (TRF) assay formats are frequently used technologies in high-throughput screening. In this article, we have characterised the novel Plate::Vision(2) 96-microlens array reader (Carl Zeiss Jena GmbH, Germany) and compared it to the novel LEADseeker Generation IV multimodality imaging system (LEADseeker Gen IV; Amersham Biosciences UK Ltd., UK) for applications in the TRF mode. In europium measurements using the TRF mode, the Plate::Vision displayed a limit of detection for europium of approximately 3 pM, which was comparable to two established TRF readers, the Discovery and the Victor V (both PerkinElmer Life Sciences Inc., USA). The LEADseeker's limit of detection only extended down to europium concentrations of approximately 10 pM in these experiments. For TRF resonance energy transfer (TR-FRET) experiments, a europium-biotin (Eu-biotin) conjugate was titrated with a streptavidin-allophycocyanin (SA-APC) conjugate. The Plate::Vision produced Z' values larger than 0.5 for the acceptor fluorophor emission with concentrations of Eu-biotin as low as 3 nM combined with 175 pM SA-APC. To achieve Z' values of at least 0.5 with the LEADseeker, concentrations of 10 nM Eu-biotin combined with SA-APC of at least 0.8 nM were required. In a drug screening application using TR-FRET, the energy transfer from a europium-labelled protein X (Eu-protein X) to a complex of biotinylated peptide Y with SA-APC was measured. Using the Plate::Vision, a Z' factor larger than 0.5 for the acceptor fluorophor emission was only obtained for a Eu-protein X concentration of at least 10 nM in combination with biotinylated peptide Y/SA-APC at saturating concentrations. Both the Plate::Vision and the LEADseeker show good quality results for applications in the TRF mode and enable an increased throughput based on their shortened measurement time in comparison to classic photomultiplier tube-based readers.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Bioensaio/instrumentação , Bioensaio/métodos , Európio/análise , Európio/química , Proteínas/análise , Proteínas/metabolismo , Sensibilidade e Especificidade , Estreptavidina/química
9.
Comb Chem High Throughput Screen ; 7(8): 763-70, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15578938

RESUMO

Imaging devices used for the measurement of radioligand-receptor binding assays are typically based on charge-coupled device (CCD) cameras, which are more sensitive for red-shifted scintillation. In the past, red-shifted scintillants had only been integrated into microspheres, referred to as scintillation proximity assay (SPA) Imaging Beads. More recently, ImageFlashPlates have been developed that emit light at 615 nm when exposed to beta-radiation. In this article, we report the establishment of peptide-protein binding assays using either streptavidin-coated ImageFlashPlates or Imaging Beads in a low volume 384-well format. In these assays, we employed a biotinylated peptide X and a [33P]-phosphorylated protein Y as the binding partner. The FlashPlates required a washing step, the bead-filled microtiter plates (MTPs) needed a centrifugation step for optimal performance in the scintillation measurements. Both the peptide X-loaded FlashPlates and the beads displayed saturable binding of [33P]-phosphorylated protein Y with a similar scintillation efficiency. A KD value of about 30 nmol/l was measured using the bead-based assay. Due to the washing step in the FlashPlate experiment, approximately two-thirds of the [33P]-phosphorylated protein Y were withdrawn from equilibrium binding. This resulted in correspondingly lower scintillation signals for the FlashPlate experiment. For this reason, the FlashPlate produced a Z' value of 0.64 that was lower than the Z' value of 0.87 for the beads. Using a reference inhibitor in a competition assay produced similar IC50 values for the bead-based assay as for the FlashPlate. Depending on the local automation environment either the centrifugation step for the beads or the washing step for the FlashPlates may be considered more or less of a challenge. Low volume 384-well high-throughput screening (HTS) applicable assay formats are achievable using either the ImageFlashPlates or the Imaging Beads.


Assuntos
Diagnóstico por Imagem/métodos , Peptídeos/química , Ligação Proteica , Proteínas/química , Biotina/química , Indicadores e Reagentes , Radioisótopos de Fósforo , Estreptavidina/química
10.
Asian Spine J ; 8(4): 412-20, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25187857

RESUMO

STUDY DESIGN: Retrospective case series. PURPOSE: The purpose of the study was to evaluate the efficiency and complication rate of a percutaneous anterior approach to herniated cervical disks with or without concomitant foraminal stenosis and/or spondylosis. OVERVIEW OF LITERATURE: Recent publications reflect that minimally invasive procedures gain in importance in patients and spine surgeons as they are generally associated with less tissue damage and shorter recovery times. However, for anterior percutaneous cervical discectomy, very little data is available for relevant patient populations. METHODS: Charts from patients with herniated cervical disc confirmed by magnetic resonance imaging, mainly radicular symptoms and irresponsive to conservative treatment who underwent anterior percutaneous discectomy were evaluated retrospectively. All patients were asked to return questionnaires that included visual analogue scores (VAS), MacNab score as well as subjective satisfaction data 2 years after surgery. RESULTS: Ninety-five patients were included. There were no neurological or vascular complications; only one patient suffered from transient hoarseness. During the two years after surgery, 9 patients underwent reoperation. 90.5% of the patients returned the questionnaire at 2 years' follow-up. 87.7% of them reported excellent or good outcome, 11.1% rated results as fair and 1.2% as unsatisfactory. On average, arm and neck pain improved significantly by 6.1 points and 5.8 points respectively on a ten point VAS. 94.5% stated that they would choose the same procedure again. CONCLUSIONS: This procedure has proved a safe and sufficient option for symptomatic cervical disk herniations with or without concomitant spondylosis and/or foraminal stenosis.