Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Thorac Cardiovasc Surg ; 126(2): 465-8, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12928645

RESUMO

OBJECTIVE: Standard surgical closure of an atrial septal defect via sternotomy is a safe and effective procedure with low morbidity and mortality. Considering that young female patients are frequently operated on for atrial septal defects, a minimally invasive procedure avoiding sternotomy is convincingly desirable and led to the approach through a right anterolateral minithoracotomy. The recent clinical introduction of robotically assisted surgery further reduced skin incisions and enabled totally endoscopic procedures through ports. This article reports on a first series of atrial septal defect closures of which the first case was operated on August 24, 1999, in a totally endoscopic closed chest technique using a computer-enhanced telemanipulation system. METHODS: We performed totally endoscopic atrial septal repair using the da Vinci surgical system (Intuitive Surgical, Mountain View, Calif) in 10 consecutive adult patients. Median age was 45.5 +/- 10.0 years, and preoperative New York Heart Association functional class was 1.8 +/- 0.1. Left ventricular ejection fraction was normal in all patients and mean pulmonary artery pressure amounted to 35 +/- 7 mm Hg. Shunt volume ranged from 24% to 70%. All patients displayed a fossa ovalis type of atrial septal defect; 2 of them multiperforated. RESULTS: Neither intraoperative nor postoperative complications occurred. Two patients had to be converted to minithoracotomy due to endoaortic balloon clamp failure. Length of operation was 262 +/- 37 minutes, and cardiopulmonary bypass time was 161 +/- 26 minutes. Intraoperative transesophageal echocardiography certified complete closure of the atrial septal defect in all patients. The totally endoscopic computer-enhanced technique yielded excellent cosmetic results. CONCLUSION: Totally endoscopic atrial septal repair is a feasible and safe procedure with good clinical results and excellent cosmetic outcomes. It may be considered as perfect adjunct to interventional treatment options. Further studies with larger cohorts and randomized trials are necessary to document potential benefits. Evolution in robotic technology and refinement of procedural flow may shorten procedural time and decrease costs.


Assuntos
Endoscopia , Comunicação Interatrial/cirurgia , Cirurgia Assistida por Computador , Telemedicina , Adulto , Aorta/cirurgia , Drenagem , Ecocardiografia Transesofagiana , Alemanha , Comunicação Interatrial/diagnóstico por imagem , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Pessoa de Meia-Idade , Instrumentos Cirúrgicos , Resultado do Tratamento
2.
Ann Thorac Surg ; 75(6): 1924-7; discussion 1927-8, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12822637

RESUMO

BACKGROUND: Eventual hazards from occupational exposure of operating room personnel to inhalational anesthetic agents cannot yet be definitively excluded. We determined if occupational exposure of operating room personnel to waste anesthetic gases during cardiopulmonary bypass (CPB) complies with the established governmental limits. METHODS: Ten adults underwent inhalational anesthesia for coronary artery bypass grafting with nitrous oxide and either sevoflurane (n = 5) or desflurane (n = 5). The administration of inhalational anesthetic agents was stopped before initiation of CPB. Gas samples were obtained before and during CPB every 90 seconds from the breathing zones of anesthesiologist (A), surgeon (S), and perfusionist (P). Time-weighted averages (TWA) over the time of exposure were calculated. RESULTS: The surgeon's exposure to nitrous oxide was 9.3 +/- 1.9 parts per million (ppm) before and 3.0 +/- 1.4 ppm during CPB (A: 6.7 +/- 1.1 ppm and 0.5 +/- 0.1 ppm; P: 3.7 +/- 1.4 ppm during CPB). Occupational exposure to desflurane was 0.21 +/- 0.10 ppm before and 0.62 +/- 0.28 ppm during CPB for the surgeon (A: 0.02 +/- 0.01 ppm and 0.02 +/- 0.003 ppm; P: 0.82 +/- 0.26 ppm during CPB), thereby exceeding the given limit of 0.5 ppm. Exposure levels of sevoflurane were below the 0.5 ppm limit at all times, as were nitrous oxide levels (threshold limit: 25 ppm). CONCLUSIONS: Although occupational exposure to inhalational anesthetic agents was low at most times during the study and none of the operating room staff complained about subjective or objective impairment or discomfort, all measures must be taken to further minimize occupational exposure, including sufficient air conditioning and routine use of waste gas scavenging systems on CPB equipment.


Assuntos
Anestesia por Inalação/efeitos adversos , Anestésicos Inalatórios/efeitos adversos , Ponte Cardiopulmonar , Isoflurano/análogos & derivados , Isoflurano/efeitos adversos , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Salas Cirúrgicas , Adulto , Desflurano , Monitoramento Ambiental , Feminino , Alemanha , Humanos , Masculino , Concentração Máxima Permitida , Éteres Metílicos/efeitos adversos , Óxido Nitroso/efeitos adversos , Doenças Profissionais/diagnóstico , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/prevenção & controle , Sevoflurano , Ventilação
3.
Interact Cardiovasc Thorac Surg ; 6(2): 209-13, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17669812

RESUMO

One-lung ventilation is used during a variety of surgical procedures, even in patients with pre-existing coronary artery disease. The study purpose was to elucidate if myocardial metabolism crosses the anaerobic threshold under hypoxemia during one-lung ventilation. Therefore, we determined myocardial metabolism as a marker for anaerobic myocardial metabolism in patients with significant multi-vessel coronary artery disease undergoing one-lung ventilation during minimally-invasive coronary artery bypass grafting. Twenty patients with multi-vessel coronary artery disease underwent minimally-invasive revascularisation on cardiopulmonary bypass. One-lung ventilation was used for at least 45 min prior to cardiopulmonary bypass. Blood samples were drawn from arterial and coronary sinus blood at various times throughout the procedure to determine myocardial metabolism. After institution of one-lung ventilation arterial partial pressure of oxygen decreased significantly, down to levels between 50 and 70 mmHg. During one-lung ventilation, pH and lactate levels in both arterial and coronary sinus blood remained constant. Significant changes of pH and lactate levels were observed only after cardiopulmonary bypass. No clinically significant signs of myocardial ischemia occurred in any patient. Aerobic myocardial metabolism was unaffected during one-lung ventilation in all patients. Therefore, one-lung ventilation can be applied to patients with multi-vessel coronary artery disease with an acceptable risk of turning myocardial metabolism to an anaerobic state.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Hipóxia/metabolismo , Isquemia Miocárdica/etiologia , Miocárdio/metabolismo , Consumo de Oxigênio , Oxigênio/sangue , Respiração Artificial/efeitos adversos , Idoso , Limiar Anaeróbio , Ponte Cardiopulmonar , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/metabolismo , Feminino , Parada Cardíaca Induzida , Humanos , Concentração de Íons de Hidrogênio , Hipóxia/sangue , Hipóxia/complicações , Hipóxia/etiologia , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/sangue , Isquemia Miocárdica/metabolismo , Pressão Parcial , Respiração , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
4.
World J Surg ; 29(5): 615-9; discussion 620, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15827850

RESUMO

Laparoscopic fundoplication is increasingly used for treating gastro-esophageal reflux disease in children. Mechanical and pharmacological effects may contribute to hemodynamic and respiratory changes during carbon dioxide pneumoperitoneum. The aim of the present study was to evaluate the hemodynamic and respiratory effects of pneumoperitoneum (PP) with an intra-abdominal pressure (IAP) of 12 mmHg in children undergoing robot-assisted laparoscopic fundoplication during total intravenous anesthesia. Ten children, aged 8-16 years, American Society of Anesthesiologists physical status II-III, scheduled for robot-assisted laparoscopic fundoplication in the reverse Trendelenburg position were investigated. Minute ventilation (MV), peak inspiratory pressure (PIP), IAP, heart rate (HR), mean arterial blood pressure (MAP) were recorded, together with pH, base excess, HCO3-, P(et)CO2, PaCO2, and PaO2 at six time points: before insufflation, 10, 30, 60, 90 minutes after creating PP and after desufflation. The IAP was maintained at 12 mmHg. During insufflation MAP increased significantly from 70.6 (+/-9.0) to 84.8 (+/-10.4) mmHg, MV was increased from 4.6 (+/-0.8) to 5.5 (+/-0.9) l min(-1), PIP increased, PaO2 and pH decreased. P(et)CO2 increased from 33.1 (+/-1.6) to 36.6 (+/-1.6) mmHg together with PaCO2. Hemodynamic and respiratory effects due to the intra-abdominal insufflation of CO2 with an IAP of 12 mmHg are well tolerated, and anesthesia with remifentanil, propofol and mivacurium facilitates extubation immediately at the end of surgery.


Assuntos
Fundoplicatura , Hemodinâmica , Pneumoperitônio Artificial , Respiração , Adolescente , Gasometria , Criança , Feminino , Fundoplicatura/métodos , Humanos , Laparoscopia , Masculino , Pressão , Robótica
5.
Anesth Analg ; 94(4): 774-80, table of contents, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11916772

RESUMO

UNLABELLED: In addition to single-lung ventilation (SLV), intrathoracic CO2 insufflation is mandatory for adequate exposure during totally endoscopic coronary artery bypass grafting. With transesophageal echocardiography, we investigated biventricular myocardial wall motion in 25 patients with isolated disease of the left anterior descending coronary artery who underwent totally endoscopic coronary artery bypass grafting with the "Da Vinci" robotic surgical system. At distinct time points during the operation, a cine loop of both ventricles was registered from a transgastric mid-short-axis view. Myocardial wall motion analysis was performed according to an established segmentation model of the left ventricle and to an established five-point scale for wall motion (1, normal; 5, dyskinesia). Significant alterations from preoperative baseline wall motion were visible in the septal, inferior, and anterior segments of the left ventricle at some time during the prebypass period, combined with a markedly decreased PaO2 under SLV and increased intrathoracic pressure. The same findings applied to the right ventricle; however, wall motion abnormalities were more pronounced here. After myocardial revascularization, weaning from cardiopulmonary bypass, CO2 deflation, and return to double-lung ventilation, myocardial wall motion recovered to baseline values. Clinically significant hemodynamic instability did not occur. The data suggest that robot-assisted coronary artery bypass grafting leads to significant prebypass alterations of biventricular segmental wall motion. On the basis of our data, it cannot be definitively stated whether the observed results were due to reduced oxygenation during SLV and thus "real" myocardial ischemia, intrathoracic CO2 insufflation with positive pressure leading to mechanical compromise of the heart, absolute or relative hypovolemia, or a combination of these factors. However, in this cohort, which consisted of patients with single-vessel disease and good ventricular function, these changes were of limited clinical relevance. IMPLICATIONS: Segmental myocardial wall motion was evaluated with transesophageal echocardiography during robot-assisted totally endoscopic coronary artery bypass grafting. Significant biventricular segmental wall motion abnormalities occurred before cardiopulmonary bypass under single-lung ventilation and carbon dioxide insufflation. The changes in myocardial wall motion were of limited clinical relevance.


Assuntos
Ponte de Artéria Coronária , Endoscopia , Contração Miocárdica , Robótica , Função Ventricular , Dióxido de Carbono/administração & dosagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Pneumotórax Artificial , Respiração Artificial , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA