Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Appl Microbiol Biotechnol ; 106(7): 2715-2727, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35298694

RESUMO

Nontuberculous mycobacterium (NTM) infections are increasing in the USA and have a high cost burden associated with treatment. Thus, it is necessary to understand what changes could be contributing to this increase in NTM disease rate. Water samples from 40 sites were collected from around the USA. They represented three water types: groundwater disinfected with chlorine and surface water disinfected with chlorine or monochloramine. Two methods, culture and qPCR, were used to measure M. avium and M. intracellulare. Heterotrophic bacteria and NTM counts were also measured. M. avium and M. intracellulare were molecularly detected in 25% (73/292) and 35% (102/292) of samples. The mean concentrations of M. avium and M. intracellulare were 2.8 × 103 and 4.0 × 103 genomic units (GU) L-1. The Northeast sites had the highest sample positively rate for both M. avium and M. intracellulare. The highest NTM counts and M. avium concentrations were observed in the surface water treated with chloramine. Geographic location and source water/disinfectant type were observed to significantly influence M. avium and M. intracellulare occurrence rates. These studies can help improve public health risk management by balancing disinfectant treatments and diverse microbial loads in drinking water. KEY POINTS: • M. avium (MA) culture rate increased significantly: 1% (1999) to 13%. • Culture versus qPCR method: 13% vs 31% for MA and 6% vs 35% for MI. • The results of each method type tell two different stories of MA and MI occurrence.


Assuntos
Desinfetantes , Água Potável , Cloro , Desinfetantes/farmacologia , Água Potável/microbiologia , Mycobacterium avium/genética , Complexo Mycobacterium avium/genética
2.
J Environ Eng (New York) ; 149(1): 1-12, 2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37593338

RESUMO

Four chloraminated drinking water distribution systems (CDWDSs) required to maintain numeric versus "detectable" residuals were spatially and temporally sampled for water quality and associated trihalomethane (THM) and haloacetic acid (HAA) formation. Monochloramine decreased from entry point (EP) to maximum residence time (MRT) samples while THMs and HAAs initially increased and then stabilized or slightly decreased. Subsequently, EP and MRT samples were used in laboratory-held studies to further evaluate disinfectant residual stability, chloramine speciation, and nitrification occurrence. MRT water exhibited a faster monochloramine concentration decline compared to EP water, indicating a decreasing disinfectant residual stability from increasing water age through distribution. Using a simple technique based on published inorganic chloramine chemistry, samples were also investigated for nondisinfectant positive interference (NDPI) on total chlorine measurements. NDPI concentrations represented up to 100% of the total chlorine concentration when total chlorine concentrations decreased to 0.05 mg-Cl2/L, indicating little to no effective disinfectant residual remained.

3.
Med Teach ; 43(9): 1019-1024, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33136451

RESUMO

The vast majority of clinical skills teaching at our medical school in London is delivered through a peer teaching programme, with research demonstrating that medical students unequivocally prefer being taught clinical skills by peer teachers (students) over-qualified physicians. Peer teaching holds a plethora of benefits for both the learner and the teacher; encouraging academic and professional growth for teachers while instilling confidence in tutees through an improved learning atmosphere. Teaching is an essential skill for all physicians, and peer teaching is an invaluable method to cultivate these teaching skills throughout medical education. This article outlines 12 tips on how medical students can be effective and successful clinical skills peer teachers when faced with medical teaching opportunities, whether physically or remotely conducted. We reflect upon our roles as Peer Teacher Leads, overseeing a team of 200 medical student clinical skills peer teachers on behalf of the faculty at our university in London. We are responsible for leadership and quality assurance, holding key input into the organisation, development and delivery of clinical skills teaching. Therefore, we are able to impart unique insight and experience. This practical guidance is gathered from feedback, experience and the wider literature on the topic of peer teaching in clinical skills. We hope that these tips will enable medical student teachers to become more confident and competent in providing worthwhile training to their peers.


Assuntos
Educação de Graduação em Medicina , Educação Médica , Estudantes de Medicina , Competência Clínica , Currículo , Humanos , Grupo Associado , Ensino
4.
Appl Environ Microbiol ; 85(24)2019 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-31604766

RESUMO

Potable water can be a source of transmission for legionellosis and nontuberculous mycobacterium (NTM) infections and diseases. Legionellosis is caused largely by Legionella pneumophila, specifically serogroup 1 (Sg1). Mycobacterium avium, Mycobacterium intracellulare, and Mycobacterium abscessus are three leading species associated with pulmonary NTM disease. The estimated rates of these diseases are increasing in the United States, and the cost of treatment is high. Therefore, a national assessment of water disinfection efficacy for these pathogens was needed. The disinfectant type and total chlorine residual (TClR) were investigated to understand their influence on the detection and concentrations of the five pathogens in potable water. Samples (n = 358) were collected from point-of-use taps (cold or hot) from locations across the United States served by public water utilities that disinfected with chlorine or chloramine. The bacteria were detected and quantified using specific primer and probe quantitative-PCR (qPCR) methods. The total chlorine residual was measured spectrophotometrically. Chlorine was the more potent disinfectant for controlling the three mycobacterial species. Chloramine was effective at controlling L. pneumophila and Sg1. Plotting the TClR associated with positive microbial detection showed that an upward TClR adjustment could reduce the bacterial count in chlorinated water but was not as effective for chloramine. Each species of bacteria responded differently to the disinfection type, concentration, and temperature. There was no unifying condition among the water characteristics studied that achieved microbial control for all. This information will help guide disinfectant decisions aimed at reducing occurrences of these pathogens at consumer taps and as related to the disinfectant type and TClR.IMPORTANCE The primary purpose of tap water disinfection is to control the presence of microbes. This study evaluated the role of disinfectant choice on the presence at the tap of L. pneumophila, its Sg1 serogroup, and three species of mycobacteria in tap water samples collected at points of human exposure at locations across the United States. The study demonstrates that microbial survival varies based on the microbial species, disinfectant, and TClR.


Assuntos
Cloraminas/farmacologia , Cloro/farmacologia , Legionella pneumophila/efeitos dos fármacos , Legionella pneumophila/isolamento & purificação , Mycobacterium/efeitos dos fármacos , Mycobacterium/isolamento & purificação , Bactérias/efeitos dos fármacos , Bactérias/genética , Bactérias/isolamento & purificação , Desinfecção/métodos , Água Potável/microbiologia , Humanos , Legionella pneumophila/genética , Legionelose/microbiologia , Legionelose/prevenção & controle , Mycobacterium/genética , Infecções por Mycobacterium não Tuberculosas , Água/química , Microbiologia da Água
5.
Environ Sci Technol ; 49(10): 6127-33, 2015 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-25902261

RESUMO

Nontuberculous mycobacteria (NTMs) are environmental microorganisms that can cause infections in humans, primarily in the lung and soft tissue. The prevalence of NTM-associated diseases is increasing in the United States. Exposure to NTMs occurs primarily through human interactions with water (especially aerosolized). Potable water from sites across the U.S. was collected to investigate the presence of NTM. Water from 68 taps was sampled 4 times over the course of 2 years. In total, 272 water samples were examined for NTM using a membrane filtration, culture method. Identification of NTM isolates was accomplished by polymerase chain reaction (PCR) amplification of the 16S rRNA and hsp65 genes. NTMs were detected in 78% of the water samples. The NTM species detected most frequently were: Mycobacterium mucogenicum (52%), Mycobacterium avium (30%), and Mycobacterium gordonae (25%). Of the taps that were repeatedly positive for NTMs, the species M. avium, M. mucogenicum, and Mycobacterium abscessus were found to persist most frequently. This study also observed statistically significant higher levels of NTM in chloraminated water than in chlorinated water.


Assuntos
Água Potável/microbiologia , Infecções por Mycobacterium não Tuberculosas/epidemiologia , Micobactérias não Tuberculosas/isolamento & purificação , Humanos , Infecções por Mycobacterium não Tuberculosas/microbiologia , Infecções por Mycobacterium não Tuberculosas/transmissão , Micobactérias não Tuberculosas/genética , Reação em Cadeia da Polimerase , Prevalência , Estados Unidos/epidemiologia
6.
Environ Sci Technol ; 48(6): 3145-52, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24548208

RESUMO

In the United States, 6,868 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009-2010. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and recovered from a variety of natural freshwater environments. Human exposure to L. pneumophila Sg1 may occur from aerosolization and subsequent inhalation of household and facility water. In this study, two primer/probe sets (one able to detect L. pneumophila and the other L. pneumophila Sg1) were determined to be highly sensitive and selective for their respective targets. Over 272 water samples, collected in 2009 and 2010 from 68 public and private water taps across the United States, were analyzed using the two qPCR assays to evaluate the incidence of L. pneumophila Sg1. Nearly half of the taps showed the presence of L. pneumophila Sg1 in one sampling event, and 16% of taps were positive in more than one sampling event. This study is the first United States survey to document the occurrence and colonization of L. pneumophila Sg1 in cold water delivered from point of use taps.


Assuntos
Água Potável/microbiologia , Legionella pneumophila/isolamento & purificação , Microbiologia da Água , Abastecimento de Água/análise , Humanos , Legionella pneumophila/classificação , Legionella pneumophila/genética , Legionelose/microbiologia , Estados Unidos
7.
Sci Total Environ ; 927: 172112, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556005

RESUMO

The number of nontuberculous mycobacteria (NTM) lung disease cases is increasing in the United States (US). This respiratory disease is primarily caused by three NTM species: Mycobacterium avium, M. intracellulare, and M. abscessus. Since disease transmission could occur through water aerosolization, this study investigated these three species' occurrence (sporadic and persistent) in hot water samples collected from residences (n = 70) and office buildings (n = 30) across the US. A longitudinal survey design was used. Three quantitative Polymerase Chain Reaction (qPCR) assays were used to measure the mycobacterial species in the water samples. Additionally, the water's disinfectant residual was measured. A structure's age and square footage were evaluated to predict mycobacterial contamination. Also, the seasonal occurrence of each species was assessed by structure type. Residences had a 43 % (30/70), and office buildings had a 77 % (23/30) detection frequency of one or more Mycobacterium spp. in their hot water. The age of the structure influenced M. intracellulare detection frequency but not M. avium and M. abscessus. The structure's square footage affected M. avium and M. intracellulare detection frequency but not M. abscessus. In chlorinated water, M. intracellulare was detected 1.4× more often in office buildings' hot water than in chloraminated water. In chloraminated water, the Mycobacterium spp. were detected 2-2.5× more often in residences, while M. avium and M. abscessus were detected 1.5-2.3× more often in office buildings, compared to chlorinated water. Each Mycobacterium spp. had a different trend associated with the type of structure and disinfectant. Further research is needed to better understand NTM occurrence in the built environment to improve public health.


Assuntos
Desinfetantes , Microbiologia da Água , Desinfetantes/análise , Micobactérias não Tuberculosas , Mycobacterium , Monitoramento Ambiental/métodos , Estados Unidos
8.
Sci Total Environ ; 933: 172690, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38670361

RESUMO

Nitrification is a serious water-quality issue in chloraminated engineered water systems (EWSs). Nitrification is often remediated by a chlorine burn (i.e., a free­chlorine conversion), a short-term switch from chloramination to chlorination in EWSs. Opportunistic pathogens (OPs) are the dominant infectious agents in EWSs. However, the responses of OPs to a chlorine burn are unknown. This study for the first time assessed how a chlorine burn affected OPs in a full-scale EWS. We determined the impact of a 1.5-month chlorine burn on four dominant OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in a representative full-scale chloraminated EWS in the United States. Legionella and Mycobacterium were the most abundant OPs. In the water main, the summed concentration of the four OPs during the chlorine burn [3.27 ± 1.58 log10(GCN·L-1); GCN: genome or gene copy number] was lower (p ≤ 0.001) than before the burn [4.83 ± 0.50 log10(GCN·L-1)]. After the burn, the summed concentration increased to 4.27 ± 0.68 log10(GCN·L-1), comparable to before the burn (p > 0.05), indicating a transient effect of the chlorine burn in the water main. At the residential sites, the summed concentrations of the four OPs were comparable (p > 0.05) at 5.50 ± 0.84, 5.27 ± 1.44, and 5.08 ± 0.71 log10(GCN·L-1) before, during, and after the chlorine burn, respectively. Therefore, the chlorine burn was less effective in suppressing OP (re)growth in the premise plumbing. The low effectiveness might be due to more significant water stagnation and disinfectant residual decay in the premise plumbing. Indeed, for the entire sampling period, the total chlorine residual concentration in the premise plumbing (1.8 mg Cl2·L-1) was lower than in the water main (2.4 mg Cl2·L-1). Consequently, for the entire sampling period, the summed concentration of the four OPs in the premise plumbing [5.26 ± 1.08 log10(GCN·L-1)] was significantly higher (p < 0.001) than in the water main [4.04 ± 1.25 log10(GCN·L-1)]. In addition, the chlorine burn substantially increased the levels of disinfection by-products (DBPs) in the water main. Altogether, a chlorine burn is transient or even ineffective in suppressing OP (re)growth but raises DBP concentrations in chloraminated EWSs. Therefore, the practice of chlorine burns to control nitrification should be optimized, reconsidered, or even replaced.


Assuntos
Cloraminas , Cloro , Microbiologia da Água , Purificação da Água , Purificação da Água/métodos , Desinfetantes , Halogenação , Qualidade da Água
9.
Water Res ; 238: 119989, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37137207

RESUMO

Legionellosis is a respiratory disease of public health concern. The bacterium Legionella pneumophila is the etiologic agent responsible for >90% of legionellosis cases in the United States. Legionellosis transmission primarily occurs through the inhalation or aspiration of contaminated water aerosols or droplets. Therefore, a thorough understanding of L. pneumophila detection methods and their performance in various water quality conditions is needed to develop preventive measures. Two hundred and nine potable water samples were collected from taps in buildings across the United States. L. pneumophila was determined using three culture methods: Buffered Charcoal Yeast Extract (BCYE) culture with Matrix-assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) identification, Legiolert® 10- and 100-mL tests, and one molecular method: quantitative Polymerase Chain Reaction (qPCR) assay. Culture and molecular positive results were confirmed by secondary testing including MALDI-MS. Eight water quality variables were studied, including source water type, secondary disinfectant, total chlorine residual, heterotrophic bacteria, total organic carbon (TOC), pH, water hardness, cold- and hot-water lines. The eight water quality variables were segmented into 28 categories, based on scale and ranges, and method performance was evaluated in each of these categories. Additionally, a Legionella genus qPCR assay was used to determine the water quality variables that promote or hinder Legionella spp. occurrence. L. pneumophila detection frequency ranged from 2 to 22% across the methods tested. Method performance parameters of sensitivity, specificity, positive and negative predictive values, and accuracy were >94% for the qPCR method but ranged from 9 to 100% for the culture methods. Water quality influenced L. pneumophila determination by culture and qPCR methods. L. pneumophila qPCR detection frequencies positively correlated with TOC and heterotrophic bacterial counts. The source water-disinfectant combination influenced the proportion of Legionella spp. that is L. pneumophila. Water quality influences L. pneumophila determination. To accurately detect L. pneumophila, method selection should consider the water quality in addition to the purpose of testing (general environmental monitoring versus disease-associated investigations).


Assuntos
Desinfetantes , Legionella pneumophila , Legionella , Legionelose , Humanos , Qualidade da Água , Legionelose/epidemiologia , Legionelose/microbiologia , Legionelose/prevenção & controle , Microbiologia da Água , Abastecimento de Água
10.
Int J Hyg Environ Health ; 245: 114023, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-36058110

RESUMO

AIM: To observe how Legionella pneumophila, the causative agent for legionellosis, can transmit through the hot water plumbing of residences and office buildings. METHOD AND RESULTS: Using qPCR, L. pneumophila and L. pneumophila Serogroup (Sg)1 were measured in hot water samples collected from 100 structures, consisting of 70 residences and 30 office buildings. The hot water samples collected from office buildings had a higher L. pneumophila detection frequency of 53% (16/30) than residences, with a 103 GU/L (median) concentration. An office building's age was not a statistically significant predictor of contamination, but its area (>100,000 sq. ft.) was, P = <0.001. Hot water samples collected at residences had a lower L. pneumophila detection frequency of 36% (25/70) than office buildings, with a 100 GU/L (median) concentration. A residence's age was a significant predictor of contamination, P = 0.009, but not its area. The water's secondary disinfectant type did not affect L. pneumophila detection frequency nor its concentration in residences, but the secondary disinfectant type did affect results in office buildings. Legionella pneumophila's highest detection frequencies were in samples collected in March-August for office buildings and in June-November for residences. CONCLUSION: This study revealed that the built environment influences L. pneumophila transport and fate. Residential plumbing could be a potential "conduit" for L. pneumophila exposure from a source upstream of the hot water environment. Both old and newly built office buildings had an equal probability of L. pneumophila contamination. Legionella-related remediation efforts in office buildings (that contain commercial functions only) might not significantly improve a community's public health.


Assuntos
Desinfetantes , Legionella pneumophila , Legionella , Engenharia Sanitária , Água , Microbiologia da Água , Abastecimento de Água
11.
Rheumatol Adv Pract ; 5(3): rkab081, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34859176

RESUMO

OBJECTIVES: Advanced therapies (AT), including biologics, biosimilars and Janus kinase inhibitors, have dramatically improved the quality of life of patients with RA, PsA and axial spondyloarthritis (axSpA). Evidence-based criteria for prescribing these drugs in England and Wales is formulated by the National Institute for Health and Care Excellence (NICE) through health technology appraisals and guidelines, with the aim of providing equitable access to AT for patients with severe or resistant disease. Similar bodies exist in some, but not all European countries, with disparities in AT access between countries for RA. We examined whether this disparity was mirrored in England for RA, PsA and axSpA despite the National Health Service in England and Wales being legally obliged to provide funding for AT recommended by NICE's Health Technology Appraisal board, through the commissioning bodies, the clinical commissioning groups (CCGs). METHODS: We requested AT pathways from CCGs in England. Where these were not available, individual hospital Trusts were contacted using freedom of information requests. RESULTS: We found marked variability in the way that CCGs in England interpret NICE guidance. We found 41, 29 and 25 different pathways for RA, PsA and axSpA, respectively. Similar disparities existed with sequential prescribing where one AT did not work, with limits on the numbers of sequential AT in 54%, 59% and 59% of CCGs for RA, PsA and axSpA, respectively, and with these limits being different for the same condition between CCGs. CONCLUSION: Although patients at identical stages of their disease course should have access to the same NICE-approved AT, we found this is not the case for large parts of England. Inequality of access was found between regions, mirroring the variability that occurs between countries throughout Europe. Harmonization of access needs to be addressed by policymakers to ensure fairness in the way that clinicians and patients can access AT.

12.
Water Res ; 205: 117571, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34628111

RESUMO

Water-based opportunistic pathogens (OPs) are a leading cause of drinking-water-related disease outbreaks, especially in developed countries such as the United States (US). Physicochemical water quality parameters, especially disinfectant residuals, control the (re)growth, presence, colonization, and concentrations of OPs in drinking water distribution systems (DWDSs), while the relationship between OPs and those parameters remain unclear. This study aimed to quantify how physicochemical parameters, mainly monochloramine residual concentration, hydraulic residence time (HRT), and seasonality, affected the occurrence and concentrations of four common OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in four full-scale DWDSs in the US. Legionella as a dominant OP occurred in 93.8% of the 64 sampling events and had a mean density of 4.27 × 105 genome copies per liter. Legionella positively correlated with Mycobacterium, Pseudomonas, and total bacteria. Multiple regression with data from the four DWDSs showed that Legionella had significant correlations with total chlorine residual level, free ammonia concentration, and trihalomethane concentration. Therefore, Legionella is a promising indicator of water-based OPs, reflecting microbial water quality in chloraminated DWDSs. The OP concentrations had strong seasonal variations and peaked in winter and/or spring possibly because of reduced water usage (i.e., increased water stagnation or HRT) during cold seasons. The OP concentrations generally increased with HRT presumably because of disinfectant residual decay, indicating the importance of well-maintaining disinfectant residuals in DWDSs for OP control. The concentrations of Mycobacterium, Pseudomonas, and V. vermiformis were significantly associated with total chlorine residual concentration, free ammonia concentration, and pH and trihalomethane concentration, respectively. Overall, this study demonstrates how the significant spatiotemporal variations of OP concentrations in chloraminated DWDSs correlated with critical physicochemical water quality parameters such as disinfectant residual levels. This work also indicates that Legionella is a promising indicator of OPs and microbial water quality in chloraminated DWDSs.


Assuntos
Água Potável , Legionella , Mycobacterium , Cloro , Água Potável/análise , Microbiologia da Água
13.
Water Res ; 205: 117689, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34607086

RESUMO

Chloramine is a secondary disinfectant used to maintain microbial control throughout public water distribution systems. This study investigated the relationship between chloramine concentration, heterotrophic bacteria, and specific Mycobacterium species. Sixty-four water samples were collected at four locations within the utility's distribution network on four occasions. Water samples were analyzed for total chlorine and monochloramine. Traditional culture methods were applied for heterotrophic bacteria and nontuberculous mycobacteria (NTM), and specific quantitative polymerase chain reaction (qPCR) assays were used to detect and quantify Mycobacterium avium, M. intracellulare, and M. abscessus. Total chlorine and monochloramine concentrations decreased between the distribution entry point (4.7 mg/L and 3.4 mg/L as Cl2, respectively) to the maximum residence time location (1.7 mg/L and 1.1 mg/L as Cl2, respectively). Results showed that heterotrophic bacteria and NTM counts increased by two logs as the water reached the average residence time (ART) location. Microbiological detection frequencies among all samples were: 86% NTMs, 66% heterotrophic bacteria, 64% M. abscessus, 48% M. intracellulare, and 2% M. avium. This study shows that heterotrophic bacteria and NTM are weakly correlated with disinfectant residual concentration, R2=0.18 and R2=0.04, respectively. Considering that specific NTMs have significant human health effects, these data fill a critical knowledge gap regarding chloramine's impact on heterotrophic bacteria and Mycobacterial species survival within public drinking water distribution systems.


Assuntos
Água Potável , Mycobacterium , Cloraminas , Desinfecção , Humanos
14.
Water (Basel) ; 13(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34804602

RESUMO

Facing challenges in water demands and population size, particularly in the water-scarce regions in the United States, the reuse of treated municipal wastewater has become a viable potential to relieve the ever-increasing demands of providing water for (non-)potable use. The objectives of this study were to assess microbial quality of reclaimed water and to investigate treatability of microorganisms during different treatment processes. Raw and final treated effluent samples from three participating utilities were collected monthly for 16 months and analyzed for various microbial pathogens and fecal indicator organisms. Results revealed that the detectable levels of microbial pathogens tested were observed in the treated effluent samples from all participating utilities. Log10 reduction values (LRVs) of Cryptosporidium oocysts and Giardia cysts were at least two orders of magnitude lower than those of human adenovirus and all fecal indicator organisms except for aerobic endospores, which showed the lowest LRVs. The relatively higher LRV of the indicator organisms such as bacteriophages suggested that these microorganisms are not good candidates of viral indicators of human adenovirus during wastewater treatment processes. Overall, this study will assist municipalities considering the use of wastewater effluent as another source of drinking water by providing important data on the prevalence, occurrence, and reduction of waterborne pathogens in wastewater. More importantly, the results from this study will aid in building a richer microbial occurrence database that can be used towards evaluating reuse guidelines and disinfection practices for water reuse practices.

15.
Appl Environ Microbiol ; 76(21): 7367-70, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20817803

RESUMO

It has been suggested that Mycobacterium avium subspecies paratuberculosis has a role in Crohn's disease. The organism may be acquired but is difficult to culture from the environment. We describe a quantitative PCR (qPCR) method to detect M. avium subsp. paratuberculosis in drinking water and the results of its application to drinking water and faucet biofilm samples collected in the United States.


Assuntos
Biofilmes , Mycobacterium avium subsp. paratuberculosis , Reação em Cadeia da Polimerase/métodos , Microbiologia da Água , DNA Bacteriano/genética , Mycobacterium avium subsp. paratuberculosis/genética , Sensibilidade e Especificidade , Estados Unidos
16.
Rheumatol Adv Pract ; 4(2): rkaa013, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32685911

RESUMO

OBJECTIVE: The aim was to assess how the patient-reported outcome RA impact of disease (RAID) relates to DAS28 categories in routine care, its utility in identifying patients in DAS28 remission (RDAS) or low disease activity (LDAS) and the burden of unmet patient-reported needs in those achieving RDAS/LDAS. METHODS: DAS28 and RAID scores were collected from patients with established RA attending for routine review. The relationship between RAID and DAS28 was assessed with univariate pairwise correlation and mixed-effects linear regression analyses. RAID <2 was defined as a patient-acceptable state. RESULTS: One hundred and ninety-eight patients were assessed, with 220 observations, using DAS28-CRP categories: 47.5% RDAS, 14.1% LDAS, 31.8% moderate DAS (MDAS) and 6.6% high DAS (HDAS). Both patient visual analog scale score and tender joint count exhibited a high statistical association with RAID using linear regression (P < 0.0001). The mean RAID score per DAS28-CRP category was RDAS 1.84, LDAS 4.78, MDAS 5.60 and HDAS 7.68, with a statistically significant increase in RAID per unit increase in DAS-CRP or DAS28-ESR on linear regression (P < 0.001). Of 66 patients with RAID <2, 64 (97%) were in RDAS and 65 (98.5%) in RDAS/LDAS. Of 134 patients in RDAS/LDAS, RAID was ≥2 in 69 (51.5%), with fatigue and sleep being the worst-scoring domains. CONCLUSION: RAID functions well as a patient-reported outcome in routine care. Patients with RAID <2 have a high likelihood of being in RDAS/LDAS and, if pre-screened, could avoid a clinic visit. Analysis of RAID domains provides individualized targets for holistic care in RA management, with fatigue and sleep problems dominating unmet needs in those in RDAS/LDAS.

17.
Eur J Pharm Biopharm ; 157: 108-120, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33068736

RESUMO

Glioblastoma is a malignant brain tumour with a median survival of 14.6 months from diagnosis. Despite maximal surgical resection and concurrent chemoradiotherapy, reoccurrence is inevitable. To try combating the disease at a stage of low residual tumour burden immediately post-surgery, we propose a localised drug delivery system comprising of a spray device, bioadhesive hydrogel (pectin) and drug nanocrystals coated with polylactic acid-polyethylene glycol (NCPPs), to be administered directly into brain parenchyma adjacent to the surgical cavity. We have repurposed pectin for use within the brain, showing in vitro and in vivo biocompatibility, bio-adhesion to mammalian brain and gelling at physiological brain calcium concentrations. Etoposide and olaparib NCPPs with high drug loading have shown in vitro stability and drug release over 120 h. Pluronic F127 stabilised NCPPs to ensure successful spraying, as determined by dynamic light scattering and transmission electron microscopy. Successful delivery of Cy5-labelled NCPPs was demonstrated in a large ex vivo mammalian brain, with NCPP present in the tissue surrounding the resection cavity. Our data collectively demonstrates the pre-clinical development of a novel localised delivery device based on a sprayable hydrogel containing therapeutic NCPPs, amenable for translation to intracranial surgical resection models for the treatment of malignant brain tumours.


Assuntos
Antineoplásicos/administração & dosagem , Encéfalo/metabolismo , Portadores de Fármacos , Etoposídeo/administração & dosagem , Lactatos/química , Nanopartículas , Pectinas/química , Ftalazinas/administração & dosagem , Piperazinas/administração & dosagem , Polietilenoglicóis/química , Adesividade , Aerossóis , Animais , Antineoplásicos/química , Antineoplásicos/metabolismo , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patologia , Composição de Medicamentos , Liberação Controlada de Fármacos , Etoposídeo/química , Etoposídeo/metabolismo , Glioblastoma/tratamento farmacológico , Glioblastoma/metabolismo , Glioblastoma/patologia , Humanos , Hidrogéis , Masculino , Camundongos Nus , Ftalazinas/química , Ftalazinas/metabolismo , Piperazinas/química , Piperazinas/metabolismo , Ratos , Solubilidade , Distribuição Tecidual
18.
Paediatr Perinat Epidemiol ; 23(4): 321-31, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19523079

RESUMO

Most studies of the relationship between maternal residential proximity to sources of environmental pollution and congenital cardiovascular malformations have combined heart defects into one group or broad subgroups. The current case-control study examined whether risk of conotruncal heart defects, including subsets of specific defects, was associated with maternal residential proximity to hazardous waste sites and industrial facilities with recorded air emissions. Texas Birth Defects Registry cases were linked to their birth or fetal death certificate. Controls without birth defects were randomly selected from birth certificates. Distances from maternal addresses at delivery to National Priority List (NPL) waste sites, state superfund waste sites, and Toxic Release Inventory (TRI) facilities were determined for 1244 cases (89.5% of those eligible) and 4368 controls (88.0%). Living within 1 mile of a hazardous waste site was not associated with risk of conotruncal heart defects [adjusted odds ratio (aOR) = 0.83, 95% confidence interval (CI) = 0.54, 1.27]. This was true whether looking at most types of defects or waste sites. Only truncus arteriosus showed statistically elevated ORs with any waste site (crude OR: 2.80, 95% CI 1.19, 6.54) and with NPL sites (crude OR: 4.63, 95% CI 1.18, 13.15; aOR 4.99, 95% CI 1.26, 14.51), but the latter was based on only four exposed cases. There was minimal association between conotruncal heart defects and proximity to TRI facilities (aOR = 1.10, 95% CI = 0.91, 1.33). Stratification by maternal age or race/ethnic group made little difference in effect estimates for waste sites or industrial facilities. In this study population, maternal residential proximity to waste sites or industries with reported air emissions was not associated with conotruncal heart defects or its subtypes in offspring, with the exception of truncus arteriosus.


Assuntos
Resíduos Perigosos/efeitos adversos , Cardiopatias Congênitas/prevenção & controle , Exposição Materna/prevenção & controle , Efeitos Tardios da Exposição Pré-Natal/prevenção & controle , Adulto , Estudos de Casos e Controles , Monitoramento Ambiental/normas , Monitoramento Epidemiológico , Feminino , Cardiopatias Congênitas/epidemiologia , Habitação , Humanos , Recém-Nascido , Exposição Materna/efeitos adversos , Razão de Chances , Gravidez , Efeitos Tardios da Exposição Pré-Natal/epidemiologia , Fatores de Risco , Fatores Socioeconômicos , Texas/epidemiologia
19.
Water Sci Technol Water Supply ; 19(5): 1339-1346, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31031576

RESUMO

A full-scale reproduction of an aircraft drinking water system was conditioned using municipal tap water with a mixture of free chlorine and chloramines, and subsequently contaminated with coliforms. Disinfection was undertaken using chlorine dioxide, ozone and a mixed oxidant solution followed by flushing until no disinfectant residual remained. Results showed that coliforms were not persistent on the aircraft plumbing surfaces, and coliforms were not detected after disinfection and flushing with any disinfectant. The one exception was the aerator installed in the lavatory faucet, which was coliform positive after disinfection with ozone and mixed oxidants. These data suggest that the faucet aerators could be a source of coliform contamination that may result in coliform positive samples. Further experiments conducted on disinfection of aerators with glycolic acid and quaternary ammonia (both commonly used by the airlines) showed no detectable coliforms on coliform contaminated aerators after 30 minutes of soaking in the disinfectants.

20.
Am J Transl Res ; 8(8): 3448-59, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27648135

RESUMO

There has been an escalating interest in the medicinal use of Cannabis sativa in recent years. Cannabis is often administered orally with fat-containing foods, or in lipid-based pharmaceutical preparations. However, the impact of lipids on the exposure of patients to cannabis components has not been explored. Therefore, the aim of this study is to elucidate the effect of oral co-administration of lipids on the exposure to two main active cannabinoids, Δ(9)-tetrahydrocannabinol (THC) and cannabidiol (CBD). In this study, oral co-administration of lipids enhanced the systemic exposure of rats to THC and CBD by 2.5-fold and 3-fold, respectively, compared to lipid-free formulations. In vitro lipolysis was conducted to explore the effect of lipids on the intestinal solubilisation of cannabinoids. More than 30% of THC and CBD were distributed into micellar fraction following lipolysis, suggesting that at least one-third of the administered dose will be available for absorption following co-administration with lipids. Both cannabinoids showed very high affinity for artificial CM-like particles, as well as for rat and human CM, suggesting high potential for intestinal lymphatic transport. Moreover, comparable affinity of cannabinoids for rat and human CM suggests that similar increased exposure effects may be expected in humans. In conclusion, co-administration of dietary lipids or pharmaceutical lipid excipients has the potential to substantially increase the exposure to orally administered cannabis and cannabis-based medicines. The increase in patient exposure to cannabinoids is of high clinical importance as it could affect the therapeutic effect, but also toxicity, of orally administered cannabis or cannabis-based medicines.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA