1.
J Cataract Refract Surg ; 33(8): 1477-81, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17662447

RESUMO

Endothelial decompensation is a serious complication of phakic intraocular lens (pIOL) implantation and is a major concern during the postoperative period. We report 3 eyes in which the same foldable angle-supported pIOL was implanted to correct high myopia. Rapid and severe postoperative endothelial cell loss occurred in all 3 eyes. An over-sized pIOL that induced excessive vaulting into the anterior chamber was the main risk factor. In 2 eyes, the pIOL was explanted uneventfully; 1 eye required Descemet's stripping automated endothelial keratoplasty because of total endothelial decompensation. These cases illustrate the importance of accurate sizing of foldable angle-supported anterior chamber pIOLs to avoid excessive vaulting. They also highlight the importance of regular follow-up and preventive pIOL explantation as soon as significant endothelial cell loss is detected.


Assuntos
Câmara Anterior/cirurgia , Doenças da Córnea/etiologia , Endotélio Corneano/patologia , Implante de Lente Intraocular/efeitos adversos , Cristalino/fisiologia , Miopia/cirurgia , Complicações Pós-Operatórias , Câmara Anterior/diagnóstico por imagem , Feminino , Humanos , Masculino , Microscopia Acústica , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA