Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Obstet Gynecol ; 231(1): 115.e1-115.e11, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38408622

RESUMO

BACKGROUND: Diabetes is an independent risk factor for mesh complications in women undergoing mesh-augmented surgical repairs of stress urinary incontinence and/or pelvic organ prolapse. The underlying mechanism remains unclear. OBJECTIVE: This study aimed to define the diabetes-associated alterations in the host inflammatory response to mesh and correlate them with perioperative glucose management. STUDY DESIGN: Deidentified demographics and medical records of patients who underwent mesh removal and participated in a mesh biorepository study were reviewed (n=200). In patients with diagnosed diabetes (n=25), blood glucose management before initial mesh implantation and before and after mesh removal was assessed by blood glucose and hemoglobin A1c levels. Age- and body mass index-matched tissue samples excised from patients with and without diabetes were examined. Transcriptomic profiles of immune cell markers, immune mediators, key inflammatory regulators, cell senescence, and epigenetic enzymes were determined by multiplex transcriptomic assays (NanoString). Ratios of apoptotic cells to CD68+ macrophages were examined with immunofluorescence. Protein profiles of 12 molecules involved in apoptotic cell clearance were examined with a multiplex protein assay (Luminex). RESULTS: Demographic and clinical characteristics, including duration between mesh implantation and removal, reason for removal, and type of mesh, etc., were comparable between patients with and without diabetes, except for 11.6% higher body mass index in the former (P=.005). In patients with diabetes, suboptimal management of blood glucose following mesh implantation was observed, with 59% of the patients having loosely or poorly controlled glucose before and after the mesh removal. Ongoing chronic inflammatory response was observed in the excised mesh-tissue complexes in both groups, whereas markers for M2 macrophages (Mrc1 [mannose receptor C-type 1]) and helper T cells (Cd4 [CD4 molecule]) were increasingly expressed in the diabetic vs nondiabetic group (P=.023 and .047, respectively). Furthermore, the gene expressions of proinflammatory Ccl24 (C-C motif chemokine ligand 24) and Ccl13 (C-C motif chemokine ligand 13) were upregulated by 1.5- and 1.8-fold (P=.035 and .027, respectively), whereas that of Il1a (interleukin 1 alpha) was paradoxically downregulated by 2.2-fold (P=.037) in the diabetic vs nondiabetic group. Interestingly, strong positive correlations were found between the expression of Ccl13, Setdb2 (SET domain bifurcated histone lysine methyltransferase 2), and M2 macrophage markers, and between the expression of Il1a, Fosl1 (activator protein-1 transcription factor subunit), and dendritic cell markers, suggesting the involvement of macrophages and dendritic cells in the diabetes-dysregulated proinflammatory response. Supportively, apoptotic cell clearance, which is an important function of macrophages, appeared to be impaired in the diabetic group, with a significantly increased protein level of CALR (calreticulin), an "eat-me" signal on the surface of apoptotic cells (P=.031), along with an increase of AXL (AXL receptor tyrosine kinase) (P=.030), which mediates apoptotic cell clearance. CONCLUSION: Diabetes was associated with altered long-term inflammatory response in complicated mesh implantation, particularly involving innate immune cell dysfunction. Suboptimal blood glycemic control following mesh implantation may contribute to this immune dysregulation, necessitating further mechanistic studies.


Assuntos
Prolapso de Órgão Pélvico , Telas Cirúrgicas , Incontinência Urinária por Estresse , Humanos , Feminino , Pessoa de Meia-Idade , Incontinência Urinária por Estresse/cirurgia , Idoso , Prolapso de Órgão Pélvico/cirurgia , Prolapso de Órgão Pélvico/imunologia , Glicemia/metabolismo , Inflamação , Macrófagos/metabolismo , Macrófagos/imunologia , Apoptose , Hemoglobinas Glicadas/metabolismo , Diabetes Mellitus/imunologia , Antígenos de Diferenciação Mielomonocítica/metabolismo , Complicações Pós-Operatórias/imunologia
2.
Am J Obstet Gynecol ; 231(2): 268.e1-268.e16, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38710268

RESUMO

BACKGROUND: Many clinical trials use systematic methodology to monitor adverse events and determine grade (severity), expectedness, and relatedness to treatments as determined by clinicians. However, patient perspectives are often not included in this process. OBJECTIVE: This study aimed to compare clinician vs patient grading of adverse event severity in a urogynecologic surgical trial. Secondary objectives were to estimate the association of patient grading of adverse events with decision-making and quality of life outcomes and to determine if patient perspective changes over time. STUDY DESIGN: This was a planned supplementary study (Patient Perspectives in Adverse Event Reporting [PPAR]) to a randomized trial comparing 3 surgical approaches to vaginal apical prolapse. In the parent trial, adverse events experienced by patients were collected per a standardized protocol every 6 months during which clinicians graded adverse event severity (mild, moderate, severe/life-threatening). In this substudy, we obtained additional longitudinal patient perspectives for 19 predetermined "PPAR adverse events." Patients provided their own severity grading (mild, moderate, severe/very severe/life-threatening) at initial assessment and at 12 and 36 months postoperatively. Clinicians and patients were masked to each other's reporting. The primary outcome was the interrater agreement (kappa statistic) for adverse event severity between the initial clinician and patient assessment, combining patient grades of mild and moderate. The association between adverse event severity and the Decision Regret Scale, Satisfaction with Decision Scale, the 12-Item Short-Form Health Survey, and Patient Global Impression of Improvement scores was assessed using the Spearman correlation coefficient (ρ) for continuous scales, the Mantel-Haenszel chi-square test for Patient Global Impression of Improvement, and t tests or chi-square tests comparing the assessments of patients who rated their adverse events or symptoms as severe with those who gave other ratings. To describe patient perspective changes over time, the intraobserver agreement was estimated for adverse event severity grade over time using weighted kappa coefficients. RESULTS: Of the 360 randomly assigned patients, 219 (61%) experienced a total of 527 PPAR adverse events (91% moderate and 9% severe/life-threatening by clinician grading). Mean patient age was 67 years; 87% were White and 12% Hispanic. Among the patients reporting any PPAR event, the most common were urinary tract infection (61%), de novo urgency urinary incontinence (35%), stress urinary incontinence (22%), and fecal incontinence (13%). Overall agreement between clinician and participant grading of severity was poor (kappa=0.24 [95% confidence interval, 0.14-0.34]). Of the 414 adverse events that clinicians graded as moderate, patients graded 120 (29%) as mild and 80 (19%) as severe. Of the 39 adverse events graded as severe by clinicians, patients graded 15 (38%) as mild or moderate. Initial patient grading of the most severe reported adverse event was mildly correlated with worse Decision Regret Scale (ρ=0.2; P=.01), 12-Item Short-Form Health Survey (ρ=-0.24; P<.01), and Patient Global Impression of Improvement (P<.01) scores. There was no association between adverse event severity and Satisfaction with Decision Scale score. Patients with an initial grading of "severe" had more regret, lower quality of life, and poorer global impressions of health than those whose worst severity grade was mild (P<.05). Agreement between the patients' initial severity ratings and their ratings at 12 months (kappa=0.48 [95% confidence interval, 0.39-0.58]) and 36 months (kappa=0.45 [95% confidence interval, 0.37-0.53]) was fair. CONCLUSION: Clinician and patient perceptions of adverse event severity are discordant. Worse severity from the patient perspective was associated with patient-centered outcomes. Including the patient perspective provides additional information for evaluating surgical procedures.


Assuntos
Qualidade de Vida , Prolapso Uterino , Humanos , Feminino , Pessoa de Meia-Idade , Prolapso Uterino/cirurgia , Idoso , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Procedimentos Cirúrgicos em Ginecologia/métodos , Complicações Pós-Operatórias , Índice de Gravidade de Doença , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente
3.
BJOG ; 131(3): 267-277, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37522240

RESUMO

OBJECTIVE: To identify vaginal morphology and position factors associated with prolapse recurrence following vaginal surgery. DESIGN: Secondary analysis of magnetic resonance images (MRI) of the Defining Mechanisms of Anterior Vaginal Wall Descent cross-sectional study. SETTING: Eight clinical sites in the US Pelvic Floor Disorders Network. POPULATION OR SAMPLE: Women who underwent vaginal mesh hysteropexy (hysteropexy) with sacrospinous fixation or vaginal hysterectomy with uterosacral ligament suspension (hysterectomy) for uterovaginal prolapse between April 2013 and February 2015. METHODS: The MRI (rest, strain) obtained 30-42 months after surgery, or earlier for participants with recurrence who desired reoperation before 30 months, were analysed. MRI-based prolapse recurrence was defined as prolapse beyond the hymen at strain on MRI. Vaginal segmentations (at rest) were used to create three-dimensional models placed in a morphometry algorithm to quantify and compare vaginal morphology (angulation, dimensions) and position. MAIN OUTCOME MEASURES: Vaginal angulation (upper, lower and upper-lower vaginal angles in the sagittal and coronal plane), dimensions (length, maximum transverse width, surface area, volume) and position (apex, mid-vagina) at rest. RESULTS: Of the 82 women analysed, 12/41 (29%) in the hysteropexy group and 22/41 (54%) in the hysterectomy group had prolapse recurrence. After hysteropexy, women with recurrence had a more laterally deviated upper vagina (p = 0.02) at rest than women with successful surgery. After hysterectomy, women with recurrence had a more inferiorly (lower) positioned vaginal apex (p = 0.01) and mid-vagina (p = 0.01) at rest than women with successful surgery. CONCLUSIONS: Vaginal angulation and position were associated with prolapse recurrence and suggestive of vaginal support mechanisms related to surgical technique and potential unaddressed anatomical defects. Future prospective studies in women before and after prolapse surgery may distinguish these two factors.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Estudos Prospectivos , Estudos Transversais , Resultado do Tratamento , Procedimentos Cirúrgicos em Ginecologia/métodos , Vagina/diagnóstico por imagem , Vagina/cirurgia , Histerectomia Vaginal , Prolapso Uterino/cirurgia , Prolapso de Órgão Pélvico/cirurgia
4.
Int Urogynecol J ; 35(2): 291-301, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38252279

RESUMO

INTRODUCTION AND HYPOTHESIS: Mixed urinary incontinence (MUI) is defined by the International Urogynecology Association (IUGA) and International Continence Society as the complaint of involuntary leakage of urine associated with urgency and also with exertion, effort, sneezing or coughing. It therefore implies the coexistence of both stress urinary incontinence (SUI) and urgency urinary incontinence (UUI). MUI is a heterogeneous diagnosis that requires an assessment of its individual components of SUI and UUI. Management requires an individualised approach to the symptom components. The aim of this review is to identify the assessment/investigations and management options for MUI. METHODS: A working subcommittee from the IUGA Research & Development (R&D) Committee was created and volunteers invited from the IUGA membership. A literature review was performed to provide guidance focused on the recommended assessment and management of MUI. The document was then evaluated by the entire IUGA R&D Committee and IUGA Board of Directors and revisions made. The final document represents the IUGA R&D Committee Opinion. RESULTS: The R&D Committee MUI opinion paper provides guidance on the assessment and management of women with MUI and summarises the evidence-based recommendations. CONCLUSIONS: Mixed urinary incontinence is a complex problem and successful management requires alleviation of both the stress and urge components. Care should be individualised based on patient preferences. Further research is needed to guide patients in setting goals and to determine which component of MUI to treat first. The evidence for many of the surgical/procedural treatment options for MUI are limited and needs to be explored in more detail.


Assuntos
Incontinência Urinária por Estresse , Incontinência Urinária , Humanos , Feminino , Incontinência Urinária por Estresse/complicações , Incontinência Urinária de Urgência/diagnóstico , Incontinência Urinária de Urgência/terapia , Incontinência Urinária/diagnóstico , Incontinência Urinária/terapia , Incontinência Urinária/complicações , Tosse/complicações
5.
Am J Obstet Gynecol ; 229(3): 269-274, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37116823

RESUMO

The climate change crisis poses a central threat to public health. The health outcomes of this crisis are well known, but lesser known to medical professionals is the role that healthcare delivery plays in worsening this crisis. The United States healthcare system is responsible for producing 10% of the total greenhouse gases. The adverse health outcomes caused by the overall healthcare system emissions in the United States is estimated to be 470,000 disability-adjusted life years lost, which is commensurate with the 44,000 to 98,000 people who die in hospitals each year in the United States as a consequence of preventable medical errors. Factors that contribute to healthcare greenhouse gas emissions include emissions from our facilities and from the purchase, transport, and use of supplies and waste. In the purview of obstetrics and gynecology, providers should minimize their use of disposable supplies, replace single-use specula with stainless steel specula, and educate themselves and operating room staff about best waste disposal practices. In addition, they can use their individual and collective voice to advocate for sustainable energy and supply practices. A transformation in the way we supply and power our hospitals is needed, and providers should be early adopters of this transformational change. Physician buy-in is essential to decrease the carbon footprint of our care. This narrative is a call to action for obstetricians and gynecologists to reduce our carbon footprint as a public health measure to uphold the quality of care we provide to women.


Assuntos
Gases de Efeito Estufa , Ginecologia , Feminino , Humanos , Gases de Efeito Estufa/análise , Pegada de Carbono , Atenção à Saúde , Salas Cirúrgicas
6.
J Biomech Eng ; 145(9)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37216313

RESUMO

Pelvic organ prolapse (POP) is the herniation of the pelvic organs into the vaginal space, resulting in the feeling of a bulge and organ dysfunction. Treatment of POP often involves repositioning the organs using a polypropylene mesh, which has recently been found to have relatively high rates of complications. Complications have been shown to be related to stiffness mismatches between the vagina and polypropylene, and unstable knit patterns resulting in mesh deformations with mechanical loading. To overcome these limitations, we have three-dimensional (3D)-printed a porous, monofilament membrane composed of relatively soft polycarbonate-urethane (PCU) with a stable geometry. PCU was chosen for its tunable properties as it is comprised of both hard and soft segments. The bulk mechanical properties of PCU were first characterized by testing dogbone samples, demonstrating the dependence of PCU mechanical properties on its measurement environment and the effect of print pathing. The pore dimensions and load-relative elongation response of the 3D-printed PCU membranes under monotonic tensile loading were then characterized. Finally, a fatigue study was performed on the 3D-printed membrane to evaluate durability, showing a similar fatigue resistance with a commercial synthetic mesh and hence its potential as a replacement.


Assuntos
Prolapso de Órgão Pélvico , Uretana , Feminino , Humanos , Porosidade , Polipropilenos , Teste de Materiais , Vagina
7.
Int Urogynecol J ; 33(6): 1649-1657, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35394140

RESUMO

INTRODUCTION AND HYPOTHESIS: We present a 3D computational approach for automated clitoral measurements. We hypothesized that computationally derived measurements would be comparable and less variable than reported manual measures. METHODS: In this retrospective study, MRIs of 22 nulliparous women age 20-49 years with normal vaginal and clitoral anatomy were collected. Manual segmentations were performed to reconstruct 3D models of the whole clitoris (glans, body, crura, and bulbs) and vagina. The length, width, and volume of the clitoral structures and the distance between the vagina and clitoral structures were calculated. Computed clitoral morphometrics (length, width) were compared to median [range] values from a previously published cadaver study (N = 22) using the median test and Moses extreme reaction test. Calculated distances were compared to mean (± SD) reported by a 2D MRI study (N = 20) using independent t-test and Levene's test. RESULTS: Overall, computed clitoral morphometrics were similar to manual cadaver measurements, where the majority of length and width measures had ~1-2 mm difference and had less variability (smaller range). All calculated distances were significantly smaller and had smaller SDs than manual 2D MRI values, with two-fold differences in the means and SDs. Large variation was observed in clitoral volumetric measures in our cohort. CONCLUSIONS: The proposed 3D computational method improves the standardization and consistency of clitoral measurements compared to traditional manual approaches. The use of this approach in radiographic studies will give better insight into how clitoral anatomy relates to sexual function and how both are impacted by gynecologic surgery, where outcomes can assist treatment planning.


Assuntos
Clitóris , Imageamento por Ressonância Magnética , Adulto , Cadáver , Clitóris/anatomia & histologia , Clitóris/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Vagina , Adulto Jovem
8.
Int Urogynecol J ; 33(12): 3355-3364, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35976420

RESUMO

INTRODUCTION AND HYPOTHESIS: We hypothesized that elective induction of labor (eIOL) at 39 weeks is protective of levator ani muscle injury (LAMI) and is associated with decreased pelvic symptoms at 6 weeks postpartum compared to expectant management of labor. METHODS: Prospective cohort pilot study of uncomplicated, primiparous women with a singleton, vertex gestation enrolled immediately post-vaginal delivery (VD). Subjects were dichotomized into two groups based on labor management: eIOL without complication defined by the ARRIVE trial versus spontaneous VD between 39 weeks0/7 and 42 weeks5/7 or no indication for IOL prior to 40 weeks5/7. The primary outcome was LAMI at 6 weeks postpartum as evidenced by any of the following ultrasound measures: (1) increased levator hiatal area (LHA) > 2500 mm2, (2) increased elasticity index (EI, > 75th quartile) or (3) levator enthesis avulsion. RESULTS: Analysis represents 45/102 consented women from July 2019-October 2020 (eIOL n = 22 and spontaneous VD, n = 23). Neither maternal, clinical, sociodemographic characteristics nor pelvic symptoms differed between groups. Fewer women had LAMI as defined by the primary outcome with eIOL (n = 5, 23.8%) compared to spontaneous VD (n = 15, 65.2%), p = 0.008. Levator enthesis was more deformable (increased EI) with spontaneous VD as compared to the eIOL [10.66 (8.99) vs. 5.68 (2.93), p = 0.046]. On univariate logistic regression women undergoing spontaneous VD had unadjusted OR of 6.0 (1.6-22.5, p = 0.008) of sustaining LAMI compared to those undergoing eIOL. CONCLUSIONS: Composite measures of LAMI though not pelvic floor symptoms were markedly increased in women undergoing spontaneous VD compared to those undergoing eIOL at 39 weeks.


Assuntos
Trabalho de Parto Induzido , Diafragma da Pelve , Feminino , Humanos , Gravidez , Parto Obstétrico , Trabalho de Parto Induzido/efeitos adversos , Diafragma da Pelve/diagnóstico por imagem , Diafragma da Pelve/lesões , Projetos Piloto , Estudos Prospectivos , Ultrassonografia , Ensaios Clínicos como Assunto
9.
Int Urogynecol J ; 33(1): 15-29, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34351465

RESUMO

INTRODUCTION AND HYPOTHESIS: Age is named as a risk factor for pelvic organ prolapse (POP), despite not being the primary outcome for many observational studies. Postmenopausal status is another associated factor but has many confounders. We aimed to systematically review the role of age and/or postmenopausal status in POP development. METHODS: Systematic review addressing age and hormones, more specifically by postmenopausal status, from inception to March 2020 in four databases (PubMed, Embase, WOS, Cochrane Library). Quality of evidence was classified by the ROBINS-I classification for non-randomized studies. Experimental studies, animal studies, studies linking age with recurrent POP and case series were excluded. Effect estimates were collected from adjusted odds ratio plus 95% confidence intervals. Significance level was 5%. A discussion exploring mechanistic factors was also included. RESULTS: Nineteen studies (11 cross sectional, 6 cohort and 2 case control) were included for quantitative analysis. Only two studies presented a low overall risk of bias for age; most of the domains were of moderate risk. Every additional year was responsible for a 10% increase in the risk to develop POP (OR = 1.102 [1.021-1.190]; i2 = 80%, random analysis, p = 0.012). This trend was confirmed when age was dichotomized into a cutoff of 35 (p = 0.035) and 50 (p < 0.001) years. Although an increase in the risk for POP was noted in postmenopausal women, this did not reach statistical significance (OR = 2.080 [0.927-4.668], i2 = 0%, p = 0.076). CONCLUSION: Age is a risk factor for POP; postmenopausal status was not statistically associated with POP, prompting the need for further studies addressing this factor.


Assuntos
Prolapso de Órgão Pélvico , Pós-Menopausa , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Prolapso de Órgão Pélvico/complicações , Prolapso de Órgão Pélvico/etiologia , Fatores de Risco
10.
Int Urogynecol J ; 33(2): 327-335, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33860812

RESUMO

INTRODUCTION AND HYPOTHESIS: We compared the impact of a mesh manufactured from the soft elastomer polydimethylsiloxane (PDMS) to that of a widely used lightweight polypropylene (PP) mesh. To achieve a similar overall device stiffness between meshes, the PDMS mesh was made with more material and therefore was heavier and less porous. We hypothesized that the soft polymer PDMS mesh, despite having more material, would have a similar impact on the vagina as the PP mesh. METHODS: PDMS and PP meshes were implanted onto the vaginas of 20 rabbits via colpopexy. Ten rabbits served as sham. At 12 weeks, mesh-vagina complexes were explanted and assessed for contractile function, histomorphology, total collagen, and glycosaminoglycan content. Outcome measures were compared using one-way ANOVA and Kruskal-Wallis testing with appropriate post-hoc testing. RESULTS: Relative to sham, vaginal contractility was reduced following the implantation of PP (p = 0.035) but not the softer PDMS (p = 0.495). PP had an overall greater negative impact on total collagen and glycosaminoglycan content, decreasing by 53% (p < 0.001) and 54% (p < 0.001) compared to reductions of 35% (p = 0.004 and p < 0.001) with PDMS. However, there were no significant differences in the contractility, collagen fiber thickness, total collagen, and glycosaminoglycan content between the two meshes. CONCLUSIONS: Despite having a substantially higher weight, PDMS had a similar impact on the vagina compared to a low-weight PP mesh, implicating soft polymers as potential alternatives to PP. The notion that heavyweight meshes are associated with a worse host response is not applicable when comparing across materials.


Assuntos
Prolapso de Órgão Pélvico , Polipropilenos , Animais , Elastômeros , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Coelhos , Telas Cirúrgicas , Vagina/cirurgia
11.
Int Urogynecol J ; 33(7): 1699-1710, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35267063

RESUMO

INTRODUCTION AND HYPOTHESIS: This manuscript is the International Urogynecology Consultation (IUC) on pelvic organ prolapse (POP) chapter one, committee three, on the Pathophysiology of Pelvic Organ Prolapse assessing genetics, pregnancy, labor and delivery, age and menopause and animal models. MATERIALS AND METHODS: An international group of urogynecologists and basic scientists performed comprehensive literature searches using pre-specified terms in selected biomedical databases to summarize the current knowledge on the pathophysiology of the development of POP, exploring specifically factors including (1) genetics, (2) pregnancy, labor and delivery, (3) age and menopause and (4) non-genetic animal models. This manuscript represents the summary of three systematic reviews with meta-analyses and one narrative review, to which a basic scientific comment on the current understanding of pathophysiologic mechanisms was added. RESULTS: The original searches revealed over 15,000 manuscripts and abstracts which were screened, resulting in 202 manuscripts that were ultimately used. In the area of genetics the DNA polymorphisms rs2228480 at the ESR1 gene, rs12589592 at the FBLN5 gene, rs1036819 at the PGR gene and rs1800215 at the COL1A1 gene are significantly associated to POP. In the area of pregnancy, labor and delivery, the analysis confirmed a strong etiologic link between vaginal birth and symptoms of POP, with the first vaginal delivery (OR: 2.65; 95% CI: 1.81-3.88) and forceps delivery (OR: 2.51; 95% CI: 1.24-3.83) being the main determinants. Regarding age and menopause, only age was identified as a risk factor (OR : 1.102; 95% CI: 1.02-1.19) but current data do not identify postmenopausal status as being statistically associated with POP. In several animal models, there are measurable effects of pregnancy, delivery and iatrogenic menopause on the structure/function of vaginal support components, though not on the development of POP. CONCLUSIONS: Genetics, vaginal birth and age all have a strong etiologic link to the development of POP, to which other factors may add or protect against the risk.


Assuntos
Prolapso de Órgão Pélvico , Parto Obstétrico/efeitos adversos , Feminino , Humanos , Parto , Prolapso de Órgão Pélvico/genética , Gravidez , Encaminhamento e Consulta , Vagina
12.
Aesthet Surg J ; 42(6): 689-694, 2022 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-34309680

RESUMO

BACKGROUND: A description of energy-based genitourinary non-surgical devices (energy-based devices) safety data is outlined given their rapid adoption. OBJECTIVES: The authors sought to describe adverse events for energy-based devices in the Manufacturer and User Facility Device Experience database and to compare with similar devices and other subspecialty applications. We hypothesized that products with genitourinary applications had similar adverse events to dermatologic or general surgery applications. METHODS: The authors used Reed Tech Navigator to compile adverse events reports for all registered energy-based devices. Individual adverse events reports associated with (1) non-ablative, (2) fractionated, (3) unfractionated, (4) radiofrequency, and (5) hybrid laser technologies were categorized. Adverse event characteristics were compared among genitourinary applications (n = 39) and other subspecialty applications within the same devices (n = 79). RESULTS: Eighteen manufacturers were identified, which collectively manufacture 43 products with genitourinary applications. Thirty-nine genitourinary adverse events were reported and isolated to 6 manufacturers with 11 products, of which 82% (n = 32) were injuries, 15% (n = 6) were device malfunction, and 3% (n = 1) were related to improper maintenance. Local treatment reactions were the most commonly reported injury (62%, n = 21). Adverse events varied by device type, with CO2 lasers having more burns and radiofrequency devices having higher rates of sensation loss. Comparing similar technology types, genitourinary energy-based devices had the fewest adverse events reports per device in the Manufacturer and User Facility Device Experience database. CONCLUSIONS: Adverse events were reported for one-quarter of the products currently available, and most were local treatment reactions. The reporting of adverse events is equal to that of other subspecialties, suggesting similar risk profiles. Improved reporting is needed to fully evaluate the safety of individual energy-based devices.


Assuntos
Lasers , Vagina , Bases de Dados Factuais , Feminino , Humanos , Estados Unidos , United States Food and Drug Administration
13.
Am J Obstet Gynecol ; 224(1): 78.e1-78.e7, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32707267

RESUMO

BACKGROUND: Stress urinary incontinence carries a significant healthcare burden for women worldwide. Single incision slings are minimally invasive mesh devices designed to treat stress urinary incontinence. For prolapse repair, meshes with higher porosity and lower structural stiffness have been associated with improved outcomes. OBJECTIVE: In this study, we compared the higher stiffness, lower porosity Altis sling with the lower stiffness, higher porosity Solyx sling in an ovine model. We hypothesized that SIS-B would have a negative impact on the host response. STUDY DESIGN: A total of Altis and Solyx single incision slings were implanted suburethrally into sheep according to the manufacturer's instructions on minimal tension. The mesh-urethral-vaginal complex and adjacent ungrafted vagina (no mesh control) were harvested en bloc at 3 months. Masson's trichrome and picrosirius red staining of 6 µm thin sections was performed to measure interfiber distance and tissue integration. Smooth muscle contractility to a 120 mM KCl stimulus was performed in an organ bath to measure myofiber-driven contractions. Standard biochemical assays were used to quantify glycosaminoglycan, total collagen, and elastin content, and collagen subtypes. Bending stiffness was performed in response to a uniaxial force to define susceptibility to folding/buckling. Statistical analysis was performed using Mann-Whitney, Gabriel's pairwise post hoc, Wilcoxon matched-pairs, and chi-square tests. RESULTS: The animals had similar ages (3-5 years), parity (multiparous), and weights (45-72 kg). Trichrome cross sections showed that the Altis sling buckled in a "C" or "S" shape in most samples (8 of 11), whereas buckling after Solyx sling implantation was observed in only a single sample (1 of 13; P=.004). Tissue integration, as measured by the presence of collagen or smooth muscle between the mesh fibers on trichrome 4× imaging, was increased in samples implanted with the Solyx sling compared with the Altis sling (P<.05). Total collagen content decreased significantly with both products when compared with the ungrafted vagina consistent with stress shielding. There was no difference in the 2 groups with regard to glycosaminoglycan or elastin content. The Altis sling mesh tissue complex demonstrated significantly higher amounts of both collagen types I and III than the Solyx sling-implanted tissue and the ungrafted control. Smooth muscle contractility in response to 120 mM KCl was decreased after implantation of both slings compared with the sham (P=.011 and P<.01), with no difference between mesh types (P=.099). Bending stiffness in the Altis sling was more than 4 times lower than in the Solyx, indicating an increased propensity to buckle (0.0186 vs 0.0883). CONCLUSION: The structurally stiffer Altis sling had decreased tissue integration and increased propensity to buckle after implantation. Increased collagen types I and III after the implantation of this device suggests that these changes may be associated with a fibrotic response. In contrast, the Solyx sling largely maintained a flat configuration and had improved tissue integration. The deformation of the Altis sling is not an intended effect and is likely caused by its lower bending stiffness. Both meshes induced a decrease in collagen content and smooth muscle contractility similar to previous findings for prolapse meshes and consistent with stress shielding. The long-term impact of buckling warrants further investigation.


Assuntos
Modelos Animais , Slings Suburetrais , Incontinência Urinária por Estresse/cirurgia , Vagina/cirurgia , Animais , Feminino , Ovinos
14.
Am J Obstet Gynecol ; 225(5): 506.e1-506.e28, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34087229

RESUMO

BACKGROUND: Prolapse recurrence after transvaginal surgical repair is common; however, its mechanisms are ill-defined. A thorough understanding of how and why prolapse repairs fail is needed to address their high rate of anatomic recurrence and to develop novel therapies to overcome defined deficiencies. OBJECTIVE: This study aimed to identify mechanisms and contributors of anatomic recurrence after vaginal hysterectomy with uterosacral ligament suspension (native tissue repair) vs transvaginal mesh (VM) hysteropexy surgery for uterovaginal prolapse. STUDY DESIGN: This multicenter study was conducted in a subset of participants in a randomized clinical trial by the Eunice Kennedy Shriver National Institute of Child Health and Human Development Pelvic Floor Disorders Network. Overall, 94 women with uterovaginal prolapse treated via native tissue repair (n=48) or VM hysteropexy (n=46) underwent pelvic magnetic resonance imaging at rest, maximal strain, and poststrain rest (recovery) 30 to 42 months after surgery. Participants who desired reoperation before 30 to 42 months were imaged earlier to assess the impact of the index surgery. Using a novel 3-dimensional pelvic coordinate system, coregistered midsagittal images were obtained to assess study outcomes. Magnetic resonance imaging-based anatomic recurrence (failure) was defined as prolapse beyond the hymen. The primary outcome was the mechanism of failure (apical descent vs anterior vaginal wall elongation), including the frequency and site of failure. Secondary outcomes included displacement of the vaginal apex and perineal body and change in the length of the anterior wall, posterior wall, vaginal perimeter, and introitus of the vagina from rest to strain and rest to recovery. Group differences in the mechanism, frequency, and site of failure were assessed using the Fisher exact tests, and secondary outcomes were compared using Wilcoxon rank-sum tests. RESULTS: Of the 88 participants analyzed, 37 (42%) had recurrent prolapse (VM hysteropexy, 13 of 45 [29%]; native tissue repair, 24 of 43 [56%]). The most common site of failure was the anterior compartment (VM hysteropexy, 38%; native tissue repair, 92%). The primary mechanism of recurrence was apical descent (VM hysteropexy, 85%; native tissue repair, 67%). From rest to strain, failures (vs successes) had greater inferior displacement of the vaginal apex (difference, -12 mm; 95% confidence interval, -19 to -6) and perineal body (difference, -7 mm; 95% confidence interval, -11 to -4) and elongation of the anterior vaginal wall (difference, 12 mm; 95% confidence interval, 8-16) and vaginal introitus (difference, 11 mm; 95% confidence interval, 7-15). CONCLUSION: The primary mechanism of prolapse recurrence following vaginal hysterectomy with uterosacral ligament suspension or VM hysteropexy was apical descent. In addition, greater inferior descent of the vaginal apex and perineal body, lengthening of the anterior vaginal wall, and increased size of the vaginal introitus with strain were associated with anatomic failure. Further studies are needed to provide additional insight into the mechanism by which these factors contribute to anatomic failure.


Assuntos
Imageamento por Ressonância Magnética , Pelve/diagnóstico por imagem , Falha de Tratamento , Prolapso Uterino/diagnóstico por imagem , Prolapso Uterino/cirurgia , Idoso , Feminino , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Humanos , Histerectomia Vaginal/efeitos adversos , Imageamento Tridimensional , Pessoa de Meia-Idade , Recidiva
15.
Int Urogynecol J ; 32(4): 809-818, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32870340

RESUMO

INTRODUCTION AND HYPOTHESIS: The protocol and analysis methods for the Defining Mechanisms of Anterior Vaginal Wall Descent (DEMAND) study are presented. DEMAND was designed to identify mechanisms and contributors of prolapse recurrence after two transvaginal apical suspension procedures for uterovaginal prolapse. METHODS: DEMAND is a supplementary cohort study of a clinical trial in which women with uterovaginal prolapse randomized to (1) vaginal hysterectomy with uterosacral ligament suspension or (2) vaginal mesh hysteropexy underwent pelvic magnetic resonance imaging (MRI) at 30-42 months post-surgery. Standardized protocols have been developed to systematize MRI examinations across multiple sites and to improve reliability of MRI measurements. Anatomical failure, based on MRI, is defined as prolapse beyond the hymen. Anatomic measures from co-registered rest, maximal strain, and post-strain rest (recovery) sequences are obtained from the "true mid-sagittal" plane defined by a 3D pelvic coordinate system. The primary outcome is the mechanism of failure (apical descent versus anterior vaginal wall elongation). Secondary outcomes include displacement of the vaginal apex and perineal body and elongation of the anterior wall, posterior wall, perimeter, and introitus of the vagina between (1) rest and strain and (2) rest and recovery. RESULTS: Recruitment and MRI trials of 94 participants were completed by May 2018. CONCLUSIONS: Methods papers which detail studies designed to evaluate anatomic outcomes of prolapse surgeries are few. We describe a systematic, standardized approach to define and quantitatively assess mechanisms of anatomic failure following prolapse repair. This study will provide a better understanding of how apical prolapse repairs fail anatomically.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Estudos de Coortes , Feminino , Procedimentos Cirúrgicos em Ginecologia , Humanos , Prolapso de Órgão Pélvico/diagnóstico por imagem , Prolapso de Órgão Pélvico/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento , Prolapso Uterino/diagnóstico por imagem , Prolapso Uterino/cirurgia , Vagina/diagnóstico por imagem , Vagina/cirurgia
16.
Int Urogynecol J ; 31(1): 91-99, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31418044

RESUMO

INTRODUCTION AND HYPOTHESIS: New Zealand white rabbits are an inexpensive large-animal model. This study explored the rabbit as a model for mesh-augmented colpopexy using the intra-abdominal vagina. We hypothesized that polypropylene mesh would negatively impact rabbit vaginal smooth muscle (VSM) morphology and contractile function, similar to the nonhuman primate (NHP)-the established model for prolapse mesh evaluation. METHODS: Restorelle was implanted onto the vagina of ten rabbits via lumbar colpopexy after a hysterectomy. Ten rabbits served as sham. Twelve weeks post-implantation, the vagina was excised and VSM morphology and vaginal contractility were assessed. Outcome measures were compared using independent samples t and Mann-Whitney U tests with a Bonferroni correction, where appropriate. Results from the rabbits were compared with published NHP data. RESULTS: Animals had similar age, parity and BMI. VSM was 18% thinner after Restorelle implantation, P = 0.027. Vaginal contractility was 43% decreased in response to 120 mM KCl (P = 0.003), similar to the 46% reduction observed in the NHP vagina implanted with Restorelle (P = 0.027). Three meshes wrinkled in vivo, resulting in dramatic thinning of the underlying vagina in the area of the mesh causing a mesh exposure. CONCLUSIONS: Polypropylene mesh negatively impacts VSM morphology and vaginal contractility in the rabbit, similar to the NHP, suggesting that the rabbit may serve as an alternative large-animal model. The vaginal thinning and appearance of a mesh exposure in the area of a mesh wrinkle suggest the rabbit may also serve as a model for understanding the pathophysiology of mesh exposure.


Assuntos
Colposcopia/métodos , Prolapso de Órgão Pélvico/cirurgia , Implantação de Prótese/métodos , Telas Cirúrgicas , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Vértebras Lombares/cirurgia , Polipropilenos , Coelhos , Vagina/cirurgia
17.
Am J Obstet Gynecol ; 220(2): 187.e1-187.e8, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30419195

RESUMO

BACKGROUND: Polypropylene mesh is used widely for surgical treatment of pelvic organ prolapse and stress urinary incontinence. Although these surgeries demonstrate favorable functional and anatomic outcomes, their use has been limited by complications, the 2 most common being exposure and pain. Growing evidence suggests that T lymphocytes play a critical role in the regulation of the host response to biomaterials. OBJECTIVE: The purpose of this study was to define and characterize the T-cell response and to correlate the response to collagen deposition in fibrotic capsules in mesh tissue complexes that are removed for the complications of pain vs exposure. STUDY DESIGN: Patients who were scheduled to undergo a surgical excision of mesh for pain or exposure at Magee-Women's Hospital were offered enrollment. Forty-two mesh-vagina tissue complexes were removed for the primary complaint of exposure (n=24) vs pain (n=18). Twenty-one patients agreed to have an additional vaginal biopsy away from the site of mesh that served as control tissue. T cells were examined via immunofluorescent labeling for cell surface markers CD4+ (Th), CD8+ (cytotoxic) and foxp3 (T-regulatory cell). Frozen sections were stained with hematoxylin-eosin for gross morphologic condition and picrosirius red for collagen fiber analysis. Interrupted sodium-dodecyl sulfate gel electrophoresis was used to quantify the content of collagens type I and III, and the collagen III/I ratio. Transforming growth factor-ß and connective tissue growth factor, which are implicated in the development of fibrosis, were measured via enzyme-linked immunosorbent assays. Data were analyzed with the Student's t tests, mixed effects linear regression, and Spearman's correlation coefficients. RESULTS: Demographic data were not different between groups, except for body mass index, which was 31.7 kg/m2 for the exposure group and 28.2 kg/m2 for pain (P=.04). Tissue complexes demonstrated a marked, but highly localized, foreign body response. We consistently observed a teardrop-shaped fibroma that encapsulated mesh fibers in both pain and exposure groups, with the T cells localized within the tip of this configuration away from the mesh-tissue interface. All 3 T-cell populations were significantly increased relative to control: CD4+ T helper (P<.001), foxp3+ T regulatory (P<.001), and CD8+ cytotoxic T cell (P=.034) in the exposure group. In the pain group, only T-helper (P<.001) and T-regulatory cells (P<.001) were increased, with cytotoxic T cells (P=.520) not different from control. Picrosirius red staining showed a greater area of green (thin) fibers in the exposure group (P=.025) and red (thick) fibers in the pain group (P<.001). The ratio of area green/(yellow + orange + red) that represented thin vs thick fibers was significantly greater in the exposure group (P=.005). Analysis of collagen showed that collagen type I was increased by 35% in samples with mesh complications (exposure and pain) when compared with control samples (P=.043). Strong correlations between the profibrosis cytokine transforming growth factor-ß and collagen type I and III were found in patients with pain (r≥0.833; P=.01) but not exposure (P>.7). CONCLUSION: T cells appear to play a critical role in the long-term host response to mesh and may be a central pathway that leads to complications. The complexity of this response warrants further investigation and has the potential to broaden our understanding of mesh biology and clinical outcomes.


Assuntos
Colágeno/metabolismo , Reação a Corpo Estranho/imunologia , Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Linfócitos T/metabolismo , Adulto , Idoso , Biomarcadores/metabolismo , Remoção de Dispositivo , Feminino , Migração de Corpo Estranho/imunologia , Migração de Corpo Estranho/metabolismo , Migração de Corpo Estranho/patologia , Migração de Corpo Estranho/cirurgia , Reação a Corpo Estranho/diagnóstico , Reação a Corpo Estranho/metabolismo , Reação a Corpo Estranho/patologia , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/cirurgia
18.
Am J Obstet Gynecol ; 221(4): 330.e1-330.e9, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31102587

RESUMO

BACKGROUND: The use of polypropylene prolapse mesh to treat pelvic organ prolapse has been limited by mesh-related complications. Gynemesh PS mesh, implanted via sacrocolpopexy in rhesus macaques, had a negative impact on the vagina with thinning of vaginal muscularis and decreased vaginal smooth muscle contractility. The negative effect was attenuated when a bioscaffold derived from urinary bladder extracellular matrix was used as a composite with Gynemesh PS. OBJECTIVE: The objective of the study was to further elucidate the impact of Gynemesh PS polypropylene mesh and MatriStem extracellular matrix bioscaffolds on the vaginal smooth muscle in terms of micromorphology of vaginal smooth muscle (muscle bundles and individual myocytes), innervation, and nerve-mediated contractile function following their implantations in a rhesus macaque model via sacrocolpopexy. STUDY DESIGN: Thirty-two middle-aged rhesus macaques were randomized to undergo either a sham surgery (sham, n = 8), or the implantation of Gynemesh PS alone (n = 8) vs composite mesh comprised of Gynemesh PS plus 2-ply MatriStem (n = 8) vs 6-ply MatriStem alone (n = 8) via sacrocolpopexy. The graft-vagina complexes were harvested 3 months later. Histomorphometrics of smooth muscle bundles and myocytes were performed by immunofluorescent labeling of alpha smooth muscle actin, caveolin-3 (membrane protein), and cell nuclei followed by confocal imaging. The cross-sectional diameters of smooth muscle bundles and individual myocytes were quantified using images randomly taken in at least 5 areas of each section of sample. Contractile proteins alpha smooth muscle actin and smoothelin were quantified by Western immunoblotting. Nerve density was measured by immunohistochemical labeling of a pan-neuron marker, PGP9.5. Nerve-mediated smooth muscle contractility was quantified using electrical field stimulation. One-way analysis of variance and appropriate post hoc tests were used for statistical comparisons. RESULTS: Compared with sham, the implantation of Gynemesh PS alone resulted in a disorganized smooth muscle morphology with the number of small muscle bundles (cross-sectional diameter less than 20 µm) increased 67% (P = .004) and the myocyte diameter decreased 22% (P < .001). Levels of contractile proteins were all decreased vs sham with alpha smooth muscle actin decreased by 68% (P = .009), low-molecular-weight smoothelin by 51% (P = .014), and high-molecular-weight smoothelin by 40% (P = .015). Nerve density was decreased by 48% (P = .03 vs sham) paralleled by a 63% decrease of nerve-mediated contractility (P = .02). Following the implantation of composite mesh, the results of measurements were similar to sham (all P > .05), with a 39% increase in the myocyte diameter (P < .001) and a 2-fold increase in the level of alpha smooth muscle actin relative to Gynemesh (P = .045). Following the implantation of MatriStem alone, the number of small muscle bundles were increased 54% vs sham (P = .002), while the other parameters were not significantly different from sham (all P > .05). CONCLUSION: The implantation of Gynemesh PS had a negative impact on the structural and functional integrity of vaginal smooth muscle evidenced by atrophic macro- and microscopic muscle morphology, decreased innervation, and impaired contractile property, consistent with a maladaptive remodeling response. The extracellular matrix bioscaffold (MatriStem), when used with Gynemesh PS as a composite (2 ply), attenuated the negative impact of Gynemesh PS; when used alone (6 ply), it induced adaptive remodeling as evidenced by an increased fraction of small smooth muscle bundles with normal contractility.


Assuntos
Matriz Extracelular , Contração Muscular/fisiologia , Músculo Liso/patologia , Miócitos de Músculo Liso/patologia , Polipropilenos , Telas Cirúrgicas , Alicerces Teciduais , Vagina/patologia , Actinas , Animais , Materiais Biocompatíveis , Feminino , Macaca mulatta , Microscopia Confocal , Músculo Liso/inervação , Músculo Liso/fisiopatologia , Distribuição Aleatória , Bexiga Urinária , Prolapso Uterino/cirurgia , Vagina/inervação , Vagina/fisiopatologia
19.
Int Urogynecol J ; 30(3): 401-407, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29299627

RESUMO

INTRODUCTION AND HYPOTHESIS: Defining patient characteristics that alter vascular anatomy at the sacrum is critical for avoiding life-threatening bleeding at the time of sacrocolpopexy. We tested the hypothesis that in thinner/older women, the bifurcations of the aorta and inferior vena cava (IVC) are lower relative to S1 resulting in less space accessible for suture/mesh placement, placing this group at increased risk of major vascular injury. METHODS: In a retrospective cross-sectional study, CT scans were used to make 2D measurements and a 3D model of the aorta/IVC, intervertebral disc space, and bony anatomy using segmentation and modeling software. For analysis, Spearman's and Pearson's correlation, Student's t test and the Mann-Whitney U test were used along with multivariate analysis of variance. RESULTS: Of eligible women who had undergone abdominal/pelvic CT, 107 were included. The median locations of the aortic and IVC bifurcations utilizing 2D analysis were at the inferior L4 and middle L5 vertebral body, respectively. In 10.2% of patients, the IVC was located at the L5-S1 disc space or lower; however, 3D modeling of this space which allowed assessment of the area below the S1 "drop off" showed that the amount of accessible space for suture/mesh placement was not decreased. Utilizing 2D analysis there was no statistically significant independent correlation between age or adiposity and the aortic or IVC bifurcation. Patients who were both elderly and thinner had a lower aortic bifurcation (p = 0.005) and a trend towards a lower IVC bifurcation (p = 0.082). CONCLUSIONS: In 10.2% of women, the IVC bifurcation descended at or below the L5-S1 disc space, suggesting that this group of women is at increased risk of major vascular injury. Patients who were both thin and elderly had lower bifurcations, but there was no difference in accessible surface area for suture placement on 3D analysis. 3D modeling improved visualization of the anatomy beyond the S1 "drop off" and may provide a future tool for surgical planning once predictors of high-risk anatomy are defined.


Assuntos
Adiposidade , Aorta/anatomia & histologia , Região Lombossacral/anatomia & histologia , Sacro/anatomia & histologia , Veia Cava Inferior/anatomia & histologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Simulação por Computador , Estudos Transversais , Feminino , Humanos , Vértebras Lombares/anatomia & histologia , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral/diagnóstico por imagem , Pessoa de Meia-Idade , Modelos Anatômicos , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Veia Cava Inferior/diagnóstico por imagem , Adulto Jovem
20.
J Biomech Eng ; 141(2)2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30347035

RESUMO

Synthetic mesh for pelvic organ prolapse (POP) repair is associated with high complication rates. While current devices incorporate large pores (>1 mm), recent studies have shown that uniaxial loading of mesh reduces pore size, raising the risk for complications. However, it is difficult to translate uniaxial results to transvaginal meshes, as in vivo loading is multidirectional. Thus, the aim of this study was to (1) experimentally characterize deformation of pore diameters in a transvaginal mesh in response to clinically relevant multidirectional loading and (2) develop a computational model to simulate mesh behavior in response to in vivo loading conditions. Tension (2.5 N) was applied to each of mesh arm to simulate surgical implantation. Two loading conditions were assessed where the angle of the applied tension was altered and image analysis was used to quantify changes in pore dimensions. A computational model was developed and used to simulate pore behavior in response to these same loading conditions and the results were compared to experimental findings. For both conditions, between 26.4% and 56.6% of all pores were found to have diameters <1 mm. Significant reductions in pore diameter were noted in the inferior arms and between the two superior arms. The computational model identified the same regions, though the model generally underestimated pore deformation. This study demonstrates that multiaxial loading applied clinically has the potential to locally reduce porosity in transvaginal mesh, increasing the risk for complications. Computational simulations show potential of predicting this behavior for more complex loading conditions.


Assuntos
Teste de Materiais , Telas Cirúrgicas , Vagina , Simulação por Computador , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Porosidade , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA