Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Sensors (Basel) ; 23(15)2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37571776

RESUMO

The structural collapse of a street lighting pole represents an aspect that is often underestimated and unpredictable, but of relevant importance for the safety of people and things. These events are complex to evaluate since several sources of damage are involved. In addition, traditional inspection methods are ineffective, do not correctly quantify the residual life of poles, and are inefficient, requiring enormous costs associated with the vastness of elements to be investigated. An advantageous alternative is to adopt a distributed type of Structural Health Monitoring (SHM) technique based on the Internet of Things (IoT). This paper proposes the design of a low-cost system, which is also easy to integrate in current infrastructures, for monitoring the structural behavior of street lighting poles in Smart Cities. At the same time, this device collects previous structural information and offers some secondary functionalities related to its application, such as meteorological information. Furthermore, this paper intends to lay the foundations for the development of a method that is able to avoid the collapse of the poles. Specifically, the implementation phase is described in the aspects concerning low-cost devices and sensors for data acquisition and transmission and the strategies of information technologies (ITs), such as Cloud/Edge approaches, for storing, processing and presenting the achieved measurements. Finally, an experimental evaluation of the metrological performance of the sensing features of this system is reported. The main results highlight that the employment of low-cost equipment and open-source software has a double implication. On one hand, they entail advantages such as limited costs and flexibility to accommodate the specific necessities of the interested user. On the other hand, the used sensors require an indispensable metrological evaluation of their performance due to encountered issues relating to calibration, reliability and uncertainty.

2.
Sensors (Basel) ; 22(9)2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35591184

RESUMO

Assessment of the freshness of hen eggs destinated to human consumption is an extremely important goal for the modern food industry and sale chains, as eggs show a rapid natural aging which also depends on the storage conditions. Traditional techniques, such as candling and visual observation, have some practical limitations related to the subjective and qualitative nature of the analysis. The main objective of this paper is to propose a robust and automated approach, based on the use of pulsed phase thermography (PPT) and image processing, that can be used as an effective quality control tool to evaluate the freshness of eggs. As many studies show that the air chamber size is proportional to the egg freshness, the technique relies on the monitoring of the air chamber parameters to infer egg aging over time. The raw and phase infrared images are acquired and then post-processed by a dedicated algorithm which has been designed to automatically measure the size of the air chamber, in terms of normalized area and volume. The robustness of the method is firstly assessed through repeatability and reproducibility tests, which demonstrate that the uncertainty in the measure of the air chamber size never exceeds 5%. Then, an experimental campaign on a larger sample of 30 eggs, equally divided into three size categories (M, L, XL), is conducted. For each egg, the main sizes of the air chamber are measured with the proposed method and their evolution over time is investigated. Results have revealed, for all the egg categories, the existence of an analytic relationship and a high degree of correlation (R2 > 0.95) between the geometric data of the air chamber and the weight loss, which is a well-known marker of egg aging.


Assuntos
Galinhas , Termografia , Envelhecimento , Animais , Ovos/análise , Feminino , Reprodutibilidade dos Testes
3.
Sensors (Basel) ; 22(4)2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35214459

RESUMO

In the field of Smart Cities, especially for Smart Street Lighting and Smart Mobility, the use of low-cost devices is considered an advantageous solution due to their easy availability, cost reduction and, consequently, technological and methodological development. However, this type of transducers shows many critical issues, e.g., in metrological and reliability terms, which can significantly compromise their functionality and safety. Such issue has a large relevance when temperature and humidity are cause of a rapid aging of sensors. The aim of this work is to evaluate the effects of accelerated aging in extreme climatic conditions on the performance of a control system, based on a low-cost ultrasonic distance sensor, for public-lighting management in Smart Cities. The presented architecture allows for the detection of vehicles, pedestrians and small animals and contains a dedicated algorithm, developed in an Edge/Cloud environment, that is able to display the acquired measurements to users connected on the web. The obtained results highlight that the effect of accelerated aging is to significantly reduce the linearity of the calibration curve of the sensor and, moreover, to exponentially increase the number of outliers and invalid measurements. These limitations can be overcome by developing an appropriate self-calibration strategy.


Assuntos
Iluminação , Ultrassom , Envelhecimento , Animais , Cidades , Reprodutibilidade dos Testes
4.
Sensors (Basel) ; 21(4)2021 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-33562171

RESUMO

Digital Image Correlation (DIC) provides measurements without disturbing the specimen, which is a major advantage over contact methods. Additionally, DIC techniques provide full-field maps of response quantities like strains and displacements, unlike traditional methods that are limited to a local investigation. In this work, an experimental application of DIC is presented to investigate a problem of relevant interest in the civil engineering field, namely the interface behavior between externally bonded fabric reinforced cementitious mortar (FRCM) sheets and concrete substrate. This represents a widespread strengthening technique of existing reinforced concrete structures, but its effectiveness is strongly related to the bond behavior between composite fabric and underlying concrete. To investigate this phenomenon, a set of notched concrete beams are realized, reinforced with FRCM sheets on the bottom face, subsequently cured in different environmental conditions (humidity and temperature) and finally tested up to failure under three-point bending. Mechanical tests are carried out vis-à-vis DIC measurements using two distinct cameras simultaneously, one focused on the concrete front face and another focused on the FRCM-concrete interface. This experimental setup makes it possible to interpret the mechanical behavior and failure mode of the specimens not only from a traditional macroscopic viewpoint but also under a local perspective concerning the evolution of the strain distribution at the FRCM-concrete interface obtained by DIC in the pre- and postcracking phase.

5.
Sensors (Basel) ; 21(5)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803353

RESUMO

In the present work, a spar-buoy scaled model was designed and built through a "Lab-on-Sea" unit, equipped with an energy harvesting system. Such a system is based on deformable bands, which are loyal to the unit, to convert wave motion energy into electricity by means of piezo patch transducers. In a preliminary stage, the scaled model, suitable for tests in a controlled ripples-type wave motion channel, was tested in order to verify the "fixed-point" assumption in pitch and roll motions and, consequently, to optimize energy harvesting. A special type of structure was designed, numerically simulated, and experimentally verified. The proposed solution represents an advantageous compromise between the lightness of the used materials and the amount of recoverable energy. The energy, which was obtained from the piezo patch transducers during the simulations in the laboratory, was found to be enough to self-sustain the feasible on-board sensors and the remote data transmission system.

6.
Sensors (Basel) ; 20(20)2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33081285

RESUMO

Piezoelectric energy harvesters (PEHs) are a reduced, but fundamental, source of power for embedded, remote, and no-grid connected electrical systems. Some key limits, such as low power density, poor conversion efficiency, high internal impedance, and AC output, can be partially overcome by matching their internal electrical impedance to that of the applied resistance load. However, the applied resistance load can vary significantly in time, since it depends on the vibration frequency and the working temperature. Hence, a real-time tracking of the applied impedance load should be done to always harvest the maximum energy from the PEH. This paper faces the above problem by presenting an active control able to track and follow in time the optimal working point of a PEH. It exploits a non-conventional AC-DC converter, which integrates a single-stage DC-DC Zeta converter and a full-bridge active rectifier, controlled by a dedicated algorithm based on pulse-width modulation (PWM) with maximum power point tracking (MPPT). A prototype of the proposed converter, based on discrete components, was created and experimentally tested by applying a sudden variation of the resistance load, aimed to emulate a change in the excitation frequency from 30 to 70 Hz and a change in the operating temperature from 25 to 50 °C. Results showed the effectiveness of the proposed approach, which allowed to match the optimal load after 0.38 s for a ΔR of 47 kΩ and after 0.15 s for a ΔR of 18 kΩ.

7.
Appl Opt ; 55(25): 7142-8, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27607294

RESUMO

Electrochemical methods such as voltammetry and electrochemical impedance spectroscopy are effective for quantifying solid oxide fuel cell (SOFC) operational performance, but not for identifying and monitoring the chemical processes that occur on the electrodes' surface, which are thought to be strictly related to the SOFCs' efficiency. Because of their high operating temperature, mechanical failure or cathode delamination is a common shortcoming of SOFCs that severely affects their reliability. Infrared thermography may provide a powerful tool for probing in situ SOFC electrode processes and the materials' structural integrity, but, due to the typical design of pellet-type cells, a complete optical access to the electrode surface is usually prevented. In this paper, a specially designed SOFC is introduced, which allows temperature distribution to be measured over all the cathode area while still preserving the electrochemical performance of the device. Infrared images recorded under different working conditions are then processed by means of a dedicated image processing algorithm for quantitative data analysis. Results reported in the paper highlight the effectiveness of infrared thermal imaging in detecting the onset of cell failure during normal operation and in monitoring cathode activity when the cell is fed with different types of fuels.

8.
Sensors (Basel) ; 16(10)2016 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-27669251

RESUMO

Embedded fiber Bragg grating sensors have been extensively used worldwide for health monitoring of smart structures. In civil engineering, they provide a powerful method for monitoring the performance of composite reinforcements used for concrete structure rehabilitation and retrofitting. This paper discusses the problem of investigating the strain transfer mechanism in composite strengthened concrete beams subjected to three-point bending tests. Fiber Bragg grating sensors were embedded both in the concrete tensioned surface and in the woven fiber reinforcement. It has been shown that, if interface decoupling occurs, strain in the concrete can be up to 3.8 times higher than that developed in the reinforcement. A zero friction slipping model was developed which fitted very well the experimental data.

9.
Nanomaterials (Basel) ; 11(3)2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33804089

RESUMO

Marine pollution due to spillage of hydrocarbons represents a well-known current environmental problem. In order to recover the otherwise wasted oils and to prevent pollution damage, polyurethane foams are considered suitable materials for their ability to separate oils from sea-water and for their reusability. In this work we studied polyurethane foams filled with carbon nanofibers, in varying amounts, aimed at enhancing the selectivity of the material towards the oils and at improving the mechanical durability of the foam. Polyurethane-based foams were experimentally characterized by morphological, surface, and mechanical analyses (optical microscopy observation, contact angle measurement, absorption test according to ASTM F726-99 standard and compression fatigue tests according to ISO 24999 standard). Results indicated an increase in hydrophobic behavior and a good oleophilic character of the composite sponges besides an improved selective absorption of the foam toward oils in mixed water/oil media. The optimal filler amount was found to be around 1 wt% for the homogeneous distribution inside the polymeric foam. Finally, the fatigue test results showed an improvement of the mechanical properties of the foam with the growing carbon filler amount.

10.
Polymers (Basel) ; 12(11)2020 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-33202929

RESUMO

Polymeric joints, made of biomedical polyethylene (UHMWPE) nanocomposite sheets, were welded with a diode laser. Since polyethylene does not absorb laser light, nanocomposites were prepared containing different percentages by weight of titanium dioxide as it is a laser absorbent. The joints were first analyzed with static mechanical tests to establish the best percentage weight content of filler that had the best mechanical response. Then, the nanocomposites containing 1 wt% titanium dioxide were selected (white color) to be subjected to fatigue tests. The experimental results were also compared with those obtained on UMMWPE with a different laser light absorbent nano filler (carbon, with greater laser absorbing power, gray in color), already studied by our research team. The results showed that the two types of joints had an appreciable resistance to fatigue, depending on the various loads imposed. Therefore, they can be chosen in different applications of UHMWPE, depending on the stresses imposed during their use.

11.
J Mech Behav Biomed Mater ; 86: 390-396, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30016758

RESUMO

Biomedical grade UHMWPE double lap joint, welded by a diode laser, has been mechanically characterized by static and dynamic tests. A nanocomposite sheet (UHMWPE filled with low carbon nanoparticles amount) was interposed between two polymeric sheets in order to absorb the laser light, sealing the sheets by means of a melting process. Fatigue test has been performed in the joint with 0.016 wt% of carbon nanofiller for its best mechanical static resistance among those studied. Its fatigue limits resulted to be equal to 22000 cycles. Breaks occurred at the 2nd welded interface, where a poor melting process weakens the entire joint.


Assuntos
Materiais Biocompatíveis , Lasers Semicondutores , Teste de Materiais/instrumentação , Polietileno , Estresse Mecânico
12.
Rev Sci Instrum ; 78(2): 025103, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17578144

RESUMO

In this article an optical psychrometer, in which temperature measurements are performed by means of two fiber Bragg grating sensors used as dry-bulb and wet-bulb thermometers, is introduced. The adopted design exploits both the high accuracy of psychrometric-based relative humidity measurements with acknowledged advantages of wavelength-encoded fiber optic sensing. Important metrological issues that have been addressed in the experimental work include calibration of the fiber Bragg grating temperature sensors, evaluation of response time, sensitivity, hysteresis, linearity, and accuracy. The calibration results give confidence that, with the current experimental setup, measurement of temperature can be done with an uncertainty of +/- 0.2 degrees C and a resolution of 0.1 degrees C. A detailed uncertainty analysis is also presented in the article to investigate the effects produced by different sources of error on the combined standard uncertainty uc(U) of the relative humidity measurement, which has been estimated to be roughly within +/-2% in the range close to saturation.

13.
Med Eng Phys ; 29(1): 38-47, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16513407

RESUMO

This study aims to evaluate experimentally the behaviour after fracture consolidation of two intramedullary Gamma nail implants, having one (G1) or two (G2) distal screws, respectively. Nails have been implanted into standardized synthetic femora, instrumented with strain gauges. Strains measurements, supported by finite element numerical modelling, showed that the G2 implant, although ensuring higher flexional and torsional stiffness, can lead to localized contacts that occur between the tip of the nail and the femoral endosteum. This might be one of the reasons of the complications associated with pain in the mid-portion of the thigh after implantation which has been reported in several clinical studies when Gamma nails with two distal screws are used.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fêmur/fisiopatologia , Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Modelos Biológicos , Simulação por Computador , Elasticidade , Análise de Falha de Equipamento , Fixação Interna de Fraturas/métodos , Humanos , Desenho de Prótese , Estresse Mecânico
14.
Med Eng Phys ; 32(8): 889-97, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20655271

RESUMO

The present study addresses the question of evaluating, by combining both experimental and numerical methods, the stress/strain distribution within a standardized composite femur implanted with an anterograde intramedullary nail. A transverse diaphyseal fracture has been introduced in order to evaluate the implant response in the early postoperative clinical stage. By comparing these experimental data with those obtained in the fully healed stage, in which the bone continuity had been recovered, it was possible to get information on load sharing between the bone and the intramedullary nail, location of high strain concentrations, bone relative motion at the fracture site, and stiffness reduction caused by bone discontinuity. Experimental data were correlated with those predicted by a validated 3D finite element model of the complete implant/femur assembly to investigate the full field stress distribution either in the cortical bone, in the nail or in the locking screws. The obtained results suggest that full weight bearing in the immediate post-operating stage should not be allowed since high stress levels are generated in the outer shell of the cortical bone either around the proximal screw hole or the upper locking screw hole. Long-term implant reliability should be guaranteed instead, since after fracture consolidation equivalent von Mises stresses never exceed critical levels neither in the bone nor in the implant.


Assuntos
Materiais Biomiméticos , Pinos Ortopédicos , Fêmur/cirurgia , Modelos Biológicos , Fenômenos Biomecânicos , Elasticidade , Fêmur/fisiologia , Fêmur/fisiopatologia , Fixação Intramedular de Fraturas , Período Pós-Operatório , Reprodutibilidade dos Testes , Estresse Mecânico , Fatores de Tempo , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA