Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 240
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Echocardiography ; 40(11): 1280-1284, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37725057

RESUMO

Pregnancy and the post-partum period are known hypercoagulable states. Mid-cavitary variant Takotsubo cardiomyopathy (TCM) is uncommon and seen in only about 14% of all Takotsubo cases. Left ventricular thrombus (LVT) in the setting of mid-cavitary TCM is extremely rare, occurring in approximately 1% of cases. We describe a case of a young female, 1-week post-partum, with an acute LVT in the setting of mid-ventricular TCM, and we discuss the striking images and clinical management of this uncommon presentation.


Assuntos
Cardiomiopatia de Takotsubo , Trombose , Gravidez , Humanos , Feminino , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Trombose/diagnóstico , Trombose/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem
2.
BMC Cardiovasc Disord ; 22(1): 210, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35538411

RESUMO

BACKGROUND: With advancements in cancer treatment, the life expectancy of oncology patients has improved. Thus, transcatheter aortic valve replacement (TAVR) may be considered as a feasible option for oncology patients with severe symptomatic aortic stenosis (AS). We aim to evaluate the difference in short- and long-term all-cause mortality in cancer and non-cancer patients treated with TAVR for severe AS. METHODS: Medline, PubMed, and Cochrane Central Register of Controlled Trials were searched for relevant studies. Patients with cancer who underwent treatment with TAVR for severe AS were included and compared to an identical population without cancer. The primary endpoints were short- and long-term all-cause mortality. RESULTS: Of 899 studies included, 8 met inclusion criteria. Cancer patients had significantly higher long-term all-cause mortality after TAVR when compared to patients without cancer (risk ratio [RR] 1.43; 95% confidence interval (CI) 1.26-1.62; P < 0.01). Four studies evaluated short-term mortality after TAVR and demonstrated no difference in it in patients with and without cancer (RR 0.72; 95% CI 0.47-1.08; P = 0.11). CONCLUSION: Patients with cancer and severe AS have higher long-term all-cause mortality after TAVR. However, we found no difference in short-term all-cause mortality when comparing patients with and without cancer. The decision to perform TAVR in cancer patients should be individualized based on life expectancy and existing co-morbidities.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Neoplasias , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
J Cardiothorac Vasc Anesth ; 35(1): 310-322, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31883769

RESUMO

Today, proficiency in cardiopulmonary ultrasound is considered essential for anesthesiologists and critical care physicians. Conventional 2-dimensional images, however, do not permit optimal characterization of specific conditions (eg, diaphragmatic paralysis, major atelectasis, and pneumothorax) that may have relevant clinical implications in critical care and perioperative settings. By contrast, M-mode (motion-based) ultrasonographic imaging modality offers the highest temporal resolution in ultrasonography; this modality, therefore, can provide important information in ultrasound-driven approaches performed by anesthesiologists and intensivists for diagnosis, monitoring, and procedural guidance. Despite its practicability, M-mode has been progressively abandoned in echocardiography and is often underused in lung and diaphragmatic ultrasound. This review describes contemporary applications of M-mode ultrasonography in the practice of critical care and perioperative medicine. Information presented for each clinical application includes image acquisition and interpretation, evidence-based clinical implications in critically ill and surgical patients, and main limitations. The article focuses on tracheal, lung, and diaphragmatic ultrasound. It reviews tracheal ultrasound for procedural guidance during endotracheal intubation, confirmation of correct tube placement, and detection of esophageal intubation; lung ultrasound for the confirmation of endotracheal and endobronchial (selective) intubation and for the diagnosis of pneumothorax, alveolar-interstitial syndrome (cardiogenic v noncardiogenic pulmonary edema), pulmonary consolidation (pneumonia v major atelectasis) and pleural effusion; and diaphragmatic ultrasound for the diagnosis of diaphragmatic dysfunction and prediction of extubation success.


Assuntos
Anestesiologia , Cuidados Críticos , Humanos , Pulmão/diagnóstico por imagem , Traqueia/diagnóstico por imagem , Ultrassonografia
4.
Am Heart J ; 230: 71-81, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32941789

RESUMO

Cardiovascular randomized controlled trials (RCTs) typically set composite end points as the primary outcome to enhance statistical power. However, influence of individual component end points on overall composite outcomes remains understudied. METHODS: We searched MEDLINE for RCTs published in 6 high-impact journals (The Lancet, the New England Journal of Medicine, Journal of the American Medical Association, Circulation, Journal of the American College of Cardiology and the European Heart Journal) from 2011 to 2017. Two-armed, parallel-design cardiovascular RCTs which reported composite outcomes were included. All-cause or cardiovascular mortality, myocardial infarction, heart failure, and stroke were deemed "hard" end points, whereas hospitalization, angina, and revascularization were identified as "soft" end points. Type of outcome (primary or secondary), event rates in treatment and control groups for the composite outcome and of its components according to predefined criteria. RESULTS: Of the 45.8% (316/689) cardiovascular RCTs which used a composite outcome, 79.4% set the composite as the primary outcome. Death was the most common component (89.8%) followed by myocardial infarction (66.1%). About 80% of the trials reported complete data for each component. One hundred forty-seven trials (46.5%) incorporated a "soft" end point as part of their composite. Death contributed the least to the estimate of effects (R2 change = 0.005) of the composite, whereas revascularization contributed the most (R2 change = 0.423). CONCLUSIONS: Cardiovascular RCTs frequently use composite end points, which include "soft" end points, as components in nearly 50% of studies. Higher event rates in composite end points may create a misleading interpretation of treatment impact due to large contributions from end points with less clinical significance.


Assuntos
Doenças Cardiovasculares/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Angina Pectoris/epidemiologia , Angina Pectoris/mortalidade , Doenças Cardiovasculares/terapia , Estudos Transversais , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/mortalidade , Hospitalização/estatística & dados numéricos , Humanos , Fator de Impacto de Revistas , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/mortalidade , Revascularização Miocárdica/estatística & dados numéricos , Publicações Periódicas como Assunto , Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento
5.
Echocardiography ; 37(11): 1792-1802, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33012034

RESUMO

INTRODUCTION: The right ventricle (RV) strain measured by speckle tracking (RVS) is an echocardiographic parameter used to assess RV function. We compared RVS to RV fractional area change (FAC%), tricuspid annular plane systolic excursion (TAPSE) and Doppler tissue imaging-derived peak systolic velocity (S') in the assessment of right ventricular (RV) systolic function measured using cardiac magnetic resonance imaging (MRI). METHODS: We enrolled consecutive patients who underwent cardiac MRI between Jan 2012 and Dec 2017 and a transthoracic echocardiogram (TTE) within 1 month of the MRI with no interval event. Baseline clinical characteristics and MRI parameters were extracted from chart review. Echocardiographic parameters were measured prospectively. TTE parameters including RVS, TAPSE, S', and FAC% were tested for accuracy to identify impaired RV EF (EF < 45% & <30%) using receiver operator curves. RESULTS: The study cohort included 500 patients with mean age 55 years ± 18 and peak tricuspid regurgitation velocity 2.7 ± 1.4 m/s. The area under ROC for RVS was 0.69 (95% CI 0.63-0.75) and 0.78 (95% CI 0.70-0.88) to predict RVEF < 45% & RVEF < 30%, respectively. The RV FAC% had second highest accuracy of predicting RVEF among all the TTE parameters tested in study. CONCLUSION: Right ventricular strain is the most accurate echocardiographic method to detect impaired right ventricular systolic function when using MRI as the gold standard.


Assuntos
Disfunção Ventricular Direita , Função Ventricular Direita , Ecocardiografia , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico por imagem
7.
J Cardiothorac Vasc Anesth ; 33(6): 1559-1583, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30077562

RESUMO

Proficiency in echocardiography and lung ultrasound has become essential for anesthesiologists and critical care physicians. Nonetheless, comprehensive echocardiography measurements often are time-consuming and technically challenging, and conventional 2-dimensional images do not permit evaluation of specific conditions (eg, systolic anterior motion of the mitral valve, pneumothorax), which have important clinical implications in the perioperative setting. M-mode (motion-based) ultrasonographic imaging, however, provides the most reliable temporal resolution in ultrasonography. Hence, M-mode can provide clinically relevant information in echocardiography and lung ultrasound-driven approaches for diagnosis, monitoring, and interventional procedures performed by anesthesiologists and intensivists. Although M-mode is feasible, this imaging modality progressively has been abandoned in echocardiography and is often underutilized in lung ultrasound. This article aims to comprehensively illustrate contemporary applications of M-mode ultrasonography in the anesthesia and critical care medicine practice. Information presented for each clinical application will include image acquisition and interpretation, evidence-based clinical implications in the critically ill and surgical patient, and limitations. The present article focuses on echocardiography and reviews left ventricular function (mitral annular plane systolic excursion, E-point septal separation, fractional shortening, and transmitral propagation velocity); right ventricular function (tricuspid annular plane systolic excursion, subcostal echocardiographic assessment of tricuspid annulus kick, outflow tract fractional shortening, ventricular septal motion, wall thickness, and outflow tract obstruction); volume status and responsiveness (inferior vena cava and superior vena cava diameter and respiratory variability [collapsibility and distensibility indexes]); cardiac tamponade; systolic anterior motion of the mitral valve; and aortic dissection.


Assuntos
Anestesiologia , Cuidados Críticos/métodos , Estado Terminal , Ecocardiografia/métodos , Cardiopatias/diagnóstico , Cardiopatias/terapia , Humanos
8.
Echocardiography ; 34(1): 44-52, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27739100

RESUMO

OBJECTIVES: The tricuspid annular plane systolic excursion (TAPSE) is a validated measure of right ventricular function; however, the apical echocardiographic window varies and has limitations in intensive care unit (ICU) patients receiving mechanical ventilation or those with underlying disease and air entrapment. We aimed to evaluate the subcostal echocardiographic assessment of tricuspid annular kick (SEATAK) as an alternative to TAPSE in critically ill patients. METHODS: To measure SEATAK, we obtained the subcostal inferior vena cava view and used M-mode to measure excursion of the tricuspid annulus (kick). Analysis was performed with JMP for Bland-Altman and Spearman correlations. RESULTS: We evaluated 45 patients, 26 (57.8%) of whom were women, with a mean age of 60.8 years. We were not able to obtain the apical view to measure TAPSE in 8.9% of the patients. In contrast, SEATAK was measured in all patients. The mean SEATAK and TAPSE were 1.62 cm and 1.93 cm, respectively, with a mean pairwise difference of -0.26 cm (95% CI: -0.19 to -0.35), with the SEATAK value being lower than TAPSE. The overall correlation was strong and significant (ρ = .86, P=.03). The graphical correlation was maintained between TAPSE and SEATAK and the degree of RVF. CONCLUSION: In patients presenting with RVF in the ICU (or in situations where the apical echocardiographic view is suboptimal for tricuspid annular assessment), SEATAK can be an alternative to TAPSE. Further research is needed to validate and determine the sensitivity and specificity of SEATAK for RVF prognostication.


Assuntos
Estado Terminal , Ecocardiografia/métodos , Volume Sistólico/fisiologia , Valva Tricúspide/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sístole
9.
Echocardiography ; 33(3): 406-15, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26498324

RESUMO

BACKGROUND: Trastuzumab has substantially improved overall survival and reduced the risk of disease recurrence in patients with human epidermal growth factor receptor type II (HER-II)-positive breast cancer. However, this benefit may be at the increased risk of cardiotoxicity. We aimed to explore the early subclinical left and right ventricular as well as atrial dysfunction, in trastuzumab-treated patients with HER-II-positive breast cancer, using velocity vector imaging. METHODS: Echocardiography images were acquired in 50 patients with HER-II-positive breast cancer undergoing trastuzumab therapy. All patients had baseline and 3-6 months and 12-15 months of follow-up echocardiograms after initiation of trastuzumab therapy. Subendocardial borders of all the cardiac chambers were traced from the apical views to obtain volumetric and deformation indices. RESULTS: Mean age was 60 ± 13 years. Left ventricular (LV) ejection fraction as well as conventional indices of right ventricular (RV) function did not change with trastuzumab. The RV peak systolic global longitudinal strain (GLε) significantly decreased (-24.53 ± 6.03 vs. -21.28 ± 5.11 vs. -21.84 ± 5.15, baseline vs. first and second follow-ups, P = 0.01). LV peak systolic GLε was reduced by 1.19 at early follow-up (P < 0.05). Left atrial reservoir and booster pump functions as well as right atrial reservoir function were reduced through follow-up as well. CONCLUSIONS: The RV exhibited greater change in strain after trastuzumab treatment when compared to the LV. Atria function was reduced by trastuzumab as well. The repercussion of these findings and their potential implication will warrant further study.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Ecocardiografia/métodos , Trastuzumab/administração & dosagem , Trastuzumab/efeitos adversos , Disfunção Ventricular/induzido quimicamente , Disfunção Ventricular/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/administração & dosagem , Antineoplásicos/efeitos adversos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/efeitos dos fármacos , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Receptor ErbB-2/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico/efeitos dos fármacos , Resultado do Tratamento
10.
J Clin Ultrasound ; 44(4): 221-30, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26875513

RESUMO

PURPOSE: We aimed to explore the hypothesis that early subclinical cardiac chamber dysfunction secondary to tyrosine kinase inhibitors (TKIs) in patients with metastatic renal cell carcinoma could be signaled by abnormal cardiac mechanics demonstrated by velocity vector imaging. METHODS: Echocardiographic images were acquired from the apical views in 23 metastatic renal cell carcinoma patients. All patients had baseline and at least a 3-month follow-up echocardiogram after receiving TKI therapy. Subendocardial borders of all the cardiac chambers were traced to obtain volumetric and deformation indices. RESULTS: Mean age was 67 ± 9 years with 92% men. The right ventricle peak systolic global longitudinal strain (GLɛ) and strain rate were significantly lower after TKIs (-23.49 ± 5.1 versus -19.81 ± 5.5, p = 0.002 and -1.52 ± 0.52 versus -1.24 ± 0.35 p = 0.02, respectively). LV GLɛ was not statistically different. Volumetric and deformation indices showed a minimal decrease of the right atrium reservoir and conduit functions, and no significant changes of left atrial function. CONCLUSIONS: The right heart exhibited greater strain changes than the left heart after TKI treatment. The implications of these findings and their potential significance warrant further work.


Assuntos
Carcinoma de Células Renais/tratamento farmacológico , Ecocardiografia/métodos , Átrios do Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Neoplasias Renais/tratamento farmacológico , Inibidores de Proteínas Quinases/efeitos adversos , Disfunção Ventricular/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/secundário , Ecocardiografia Doppler , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/efeitos dos fármacos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/efeitos dos fármacos , Humanos , Neoplasias Renais/complicações , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Inibidores de Proteínas Quinases/uso terapêutico , Estudos Retrospectivos , Volume Sistólico/efeitos dos fármacos , Sístole , Disfunção Ventricular/diagnóstico , Disfunção Ventricular/fisiopatologia
11.
Adv Health Sci Educ Theory Pract ; 20(1): 193-203, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24916955

RESUMO

The Accreditation Council for Graduate Medical Education (ACGME) implemented work hour restrictions for physicians in training in 2003 that were revised July 1, 2011. Current published data are insufficient to assess whether such work hour restrictions will have long-term impact on residents' education. We searched computer-generated reports of hospital in-patient census, continuity clinic census, in-training exam scores and first-year resident attendance at educational conferences for the academic years 2010-2011 (August 1, 2010-May 31, 2011) and 2011-2013 (August 1, 2011-May 31, 2013). During the first year of the study period, the residents' inpatient internal medicine services admitted 1,754 patients; during this same period for academic years 2011-2012 and 2012-2013, the teaching services admitted 1,539 and 1,428 patients respectively, yielding a decrease of 16.4%. Monthly, these services cared for a mean of 27.1 (27.1/175.4 [15.4%]) fewer patients and 9.7 (9.7/34.4 [28.2%]) fewer patients per intern than in the previous year. No statistical difference was observed regarding continuity clinic attendance and in-training exam scores. Residents in the years following work hours restrictions attended more educational conferences. Implementation of 2011 ACGME work hour regulations resulted in fewer patients seen by first-year residents in hospital, but did not affect in-training exam scores. Whether these findings will translate into differences in patient outcomes, and quality of care remains to be seen.


Assuntos
Medicina Interna/educação , Internato e Residência , Tolerância ao Trabalho Programado , Carga de Trabalho/legislação & jurisprudência , Adulto , Congressos como Assunto , Educação de Pós-Graduação em Medicina , Avaliação Educacional , Feminino , Humanos , Masculino , Estados Unidos
12.
Echocardiography ; 32(9): 1392-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25611312

RESUMO

BACKGROUND: Atrial function is an important contributor of ventricular function and has a prognostic role in various cardiovascular diseases. We tested the hypothesis that right and left atrial (RA & LA) function may not be equal despite their accommodating identical cardiac output. METHODS: Two-dimensional (2D) speckle tracking echocardiography was acquired from the apical four-chamber view in 100 normal subjects. Both RA/LA subendocardial borders were traced to obtain atrial volumes, strain (ε) and strain rate (SR). Reservoir, conduit, and booster pump functions were evaluated. Consequently, εNeg (corresponding to pump function) and εPos (corresponding to conduit function) were gauged. The SR parameters (SRLateNeg, SRPos, and SREarlyNeg), corresponding respectively to atrial systole, inception of ventricular systole, and inception of ventricular diastole, were measured. RESULTS: Mean age was 39 ± 15 years with 50 men (50%). Volumetric indices revealed that reservoir (Filling Volume = 35.1 ± 10.4 mL for LA vs. 27.47 ± 11.93 mL for RA, expansion index = 52.18 ± 16.89% for LA vs. 45.03 ± 16.49% for RA and diastolic emptying index = 52.85 ± 16.85 for LA vs. 45.62 ± 16.5 for RA, P < 0.001) and conduit (passive emptying (%) of total emptying = 34.49 ± 10.4 for LA vs. 26.82 ± 11.98 for RA and passive emptying index = 52.63 ± 16.86 for LA vs. 45.39 ± 16.5 for RA, P < 0.001) functions were significantly higher in the LA compared to the RA. Nevertheless, deformation indices demonstrated an opposite pattern (SRpos = 1.88 ± 0.74 for RA vs. 1.56 ± 0.54 for LA, P = 0.03 and εPos = 59.56 ± 30.63 for RA vs. 45.94 ± 16.67 for LA, P < 0.001). Reservoir, conduit, and booster pump functions showed no statistical significance among both genders. CONCLUSIONS: Evaluation of global and regional RA/LA function by speckle tracking echocardiography is feasible. The current report provides insights regarding dissimilarities between both atria in healthy individuals. The significance of these findings and their potential application will warrant further work.


Assuntos
Função do Átrio Esquerdo/fisiologia , Função do Átrio Direito/fisiologia , Interpretação de Imagem Assistida por Computador , Adulto , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Valores de Referência , Ultrassonografia
13.
Echocardiography ; 32(1): 56-63, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24698472

RESUMO

OBJECTIVE: To demonstrate that a distinct group of patients with Grade Ia diastolic dysfunction who do not conform to present ASE/ESE diastolic grading exists. METHOD AND RESULTS: Echocardiographic and demographic data of the Grade Ia diastolic dysfunction were extracted and compared with that of Grades I and II in 515 patients. The mean of age of the cohort was 75 ± 9 years and body mass index did not differ significantly between the 3 groups (P = 0.45). Measurements of left atrial volume index (28.58 ± 7 mL/m(2) in I, 33 ± 10 mL/m(2) in Ia, and 39 ± 12 mL/m(2) in II P < 0.001), isovolumic relaxation time (IVRT) (100 ± 17 msec in I, 103 ± 21 msec in Ia, and 79 ± 15 msec in II P < 0.001), deceleration time (248 ± 52 msec in I, 263 ± 58 msec in Ia, and 217 ± 57 msec in II P < 0.001), medial E/e' (10 ± 3 in I, 18 ± 5.00 in Ia, and 22 ± 8 in II), and lateral E/e' (8 ± 3 in I, 15 ± 6 in Ia, and 18 ± 9 in II P < 0.001) were significantly different in grade Ia compared with I and II. These findings remained significant even after adjusting for age, gender, diabetes, and smoking. CONCLUSION: Patients with echocardiographic characteristics of relaxation abnormality (E/A ratio of <0.8) and elevated filling pressures (septal E/e' ≥15, lateral E/e' ≥12, average E/e' ≥13) should be graded as a separate Grade Ia group.


Assuntos
Ecocardiografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/classificação , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
14.
Heart Lung Circ ; 24(2): 110-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25442062

RESUMO

Aortic arch abnormalities are uncommon and may be seen in association with other congenital cardiac anomalies. Coarctation, pseudocoarctation and hypoplastic aortic arch are known aortic arch abnormalities, with the former being well studied, whilst for the latter two, much less is known. There are similarities and differences that are important to distinguish among these three conditions in order to avoid errors in diagnosis that may result in unnecessary investigations, which may in turn result in physical or emotional harm to the patient. For this reason, we present a systematic review of the published literature providing an evidence-based overview that may be helpful to clinicians when faced with this diagnostic dilemma.


Assuntos
Aorta Torácica/anormalidades , Coartação Aórtica/diagnóstico , Doenças da Aorta/diagnóstico , Humanos
16.
Cardiooncology ; 10(1): 37, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886852

RESUMO

BACKGROUND: The use of immune checkpoint inhibitors (ICIs) for the treatment of lung cancer may precipitate cardiotoxic events. We aimed to perform a meta-analysis to evaluate the cardiotoxicity associated with ICIs in patients with lung cancer. METHODS: A literature search was conducted across four electronic databases (Cochrane CENTRAL, MEDLINE, OVID EMBASE and Google Scholar) from inception through 31st May 2023. Randomized controlled trials (RCTs) assessing the impact of ICIs on cardiac outcomes in lung cancer patients were considered for inclusion. Risk ratios (RR) with 95% confidence intervals (CIs) were pooled and analysis was performed using a random-effects model. The Grading of Recommendations Assessment, Development and Evaluation approach was followed to assess confidence in the estimates of effect (i.e., the quality of evidence). RESULTS: A total of 30 studies including 16,331 patients, were included in the analysis. Pooled results showed that single ICI (RR: 2.15; 95% CI: 1.13-4.12; p = 0.02; I2 = 0%) or a combination of single ICI plus chemotherapy (RR: 1.38 [1.05-1.82]; p = 0.02) significantly increased the risk of cardiac adverse events when compared with chemotherapy alone. No significant difference was noted when a dual ICI (RR: 0.48 [0.13-1.80]; p = 0.27) was compared with single ICI. In addition, there was no significant association between the use of ICIs and incidence of cardiac failure (RR: 1.11 [0.48-2.58]; p = 0.80), or arrhythmia (RR: 1.87; [0.69-5.08]; p = 0.22). CONCLUSION: Compared with chemotherapy alone, use of a single ICI or a combination of single ICI plus chemotherapy significantly increased the risk of cardiotoxicity. However, employing dual immunotherapy did not result in a significant increase in the risk of cardiotoxicity when compared to the use of a single ICI.

17.
Cardiooncology ; 10(1): 38, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890692

RESUMO

BACKGROUND: The effects of exercise in patients with breast cancer (BC), has shown some profit, but consistency and magnitude of benefit remains unclear. We aimed to conduct a meta-analysis to assess the benefits of varying types of exercises in patients with BC. METHODS: Literature search was conducted across five electronic databases (MEDLINE, Web of Science, Scopus, Google Scholar and Cochrane) from 1st January 2000 through 19th January 2024. Randomized controlled trials (RCTs) assessing the impact of different types of exercise on outcomes related to fitness and quality of life (QOL) in patients with BC were considered for inclusion. Outcomes of interest included cardiorespiratory fitness (CRF), health-related quality of life (HRQOL), muscle strength, fatigue and physical function. Evaluations were reported as mean differences (MDs) with 95% confidence intervals (CIs) and pooled using random effects model. A p value < 0.05 was considered significant. RESULTS: Thirty-one relevant articles were included in the final analysis. Exercise intervention did not significantly improved the CRF in patients with BC when compared with control according to treadmill ergometer scale (MD: 4.96; 95%Cl [-2.79, 12.70]; P = 0.21), however exercise significantly improved CRF according to cycle ergometer scales (MD 2.07; 95% Cl [1.03, 3.11]; P = 0.0001). Physical function was significantly improved as well in exercise group reported by 6-MWT scale (MD 80.72; 95% Cl [55.67, 105.77]; P < 0.00001). However, exercise did not significantly improve muscle strength assessed using the hand grip dynamometer (MD 0.55; 95% CI [-1.61, 2.71]; P = 0.62), and fatigue assessed using the MFI-20 (MD -0.09; 95% CI [-5.92, 5.74]; P = 0.98) and Revised Piper scales (MD -0.26; 95% CI [-1.06, 0.55] P = 0.53). Interestingly, exercise was found to improve HRQOL when assessed using the FACT-B scale (MD 8.57; 95% CI [4.53, 12.61]; P < 0.0001) but no significant improvements were noted with the EORTIC QLQ-C30 scale (MD 1.98; 95% CI [-1.43, 5.40]; P = 0.25). CONCLUSION: Overall exercise significantly improves the HRQOL, CRF and physical function in patients with BC. HRQOL was improved with all exercise types but the effects on CRF vary with cycle versus treadmill ergometer. Exercise failed to improve fatigue-related symptoms and muscle strength. Large RCTs are required to evaluate the effects of exercise in patients with BC in more detail.

18.
Echocardiography ; 30(3): 354-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23405983

RESUMO

Mitral arcade (MA) is a rare congenital anomaly of the mitral valve and its tensor apparatus. This condition has been reported primarily in children younger than 3 years of age. MA is characterized by elongated papillary muscles connected to each other and to the tip of anterior mitral leaflet by a bridge of fibrous tissue. Because of progressive mitral regurgitation and/or mitral stenosis, survival into adulthood is rare. Not much is known about MA in the adult population. In this review we address the demographic features, clinical presentation, diagnosis, treatment, and outcome of this congenital anomaly in adult patients.


Assuntos
Ecocardiografia/estatística & dados numéricos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Valva Mitral/anormalidades , Valva Mitral/diagnóstico por imagem , Adolescente , Adulto , Idoso , Comorbidade , Feminino , Humanos , Incidência , Masculino , Doenças Raras/diagnóstico por imagem , Doenças Raras/epidemiologia
20.
Heart Lung Circ ; 22(5): 390-1, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23121998

RESUMO

Aneurysms of sinus of Valsalva are rare congenital or acquired cardiac anomalies. They most commonly involve the right or non-coronary sinuses. Herein we report a very rare case of a ruptured congenital right sinus of Valsalva aneurysm into the right ventricular outflow tract followed conservatively for at least 10 years without any events.


Assuntos
Ruptura Aórtica , Cardiopatias Congênitas , Ventrículos do Coração , Seio Aórtico , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/patologia , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA