Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Clin Pathol ; 14: 33, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25071417

RESUMO

BACKGROUND: Immunoassays are widely used in clinical laboratories for measurement of plasma/serum concentrations of steroid hormones such as cortisol and testosterone. Immunoassays can be performed on a variety of standard clinical chemistry analyzers, thus allowing even small clinical laboratories to do analysis on-site. One limitation of steroid hormone immunoassays is interference caused by compounds with structural similarity to the target steroid of the assay. Interfering molecules include structurally related endogenous compounds and their metabolites as well as drugs such as anabolic steroids and synthetic glucocorticoids. METHODS: Cross-reactivity of a structurally diverse set of compounds were determined for the Roche Diagnostics Elecsys assays for cortisol, dehydroepiandrosterone (DHEA) sulfate, estradiol, progesterone, and testosterone. These data were compared and contrasted to package insert data and published cross-reactivity studies for other marketed steroid hormone immunoassays. Cross-reactivity was computationally predicted using the technique of two-dimensional molecular similarity. RESULTS: The Roche Elecsys Cortisol and Testosterone II assays showed a wider range of cross-reactivity than the DHEA sulfate, Estradiol II, and Progesterone II assays. 6-Methylprednisolone and prednisolone showed high cross-reactivity for the cortisol assay, with high likelihood of clinically significant effect for patients administered these drugs. In addition, 21-deoxycortisol likely produces clinically relevant cross-reactivity for cortisol in patients with 21-hydroxylase deficiency, while 11-deoxycortisol may produce clinically relevant cross-reactivity in 11ß-hydroxylase deficiency or following metyrapone challenge. Several anabolic steroids may produce clinically significant false positives on the testosterone assay, although interpretation is limited by sparse pharmacokinetic data for some of these drugs. Norethindrone therapy may impact immunoassay measurement of testosterone in women. Using two-dimensional similarity calculations, all compounds with high cross-reactivity also showed a high degree of similarity to the target molecule of the immunoassay. CONCLUSIONS: Compounds producing cross-reactivity in steroid hormone immunoassays generally have a high degree of structural similarity to the target hormone. Clinically significant interactions can occur with structurally similar drugs (e.g., prednisolone and cortisol immunoassays; methyltestosterone and testosterone immunoassays) or with endogenous compounds such as 21-deoxycortisol that can accumulate to very high concentrations in certain disease conditions. Simple similarity calculations can help triage compounds for future testing of assay cross-reactivity.

2.
BMC Clin Pathol ; 12: 15, 2012 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23006828

RESUMO

BACKGROUND: Hepatitis B virus (HBV) is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg) are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. METHODS: The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone) results. RESULTS: During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests) revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. CONCLUSIONS: Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days post-vaccination. Our study also demonstrates that weakly positive HBsAg results often do not reflect actual HBV infection, underscoring the importance of confirmatory testing. This study also emphasizes that vaccination-induced HBsAg positives occur most commonly in hemodialysis patients.

3.
J Pathol Inform ; 13: 100006, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35242445

RESUMO

BACKGROUND: Point-of-care (POC) testing equipment is commonly utilized in outpatient clinics. Our institution recently interfaced POC chemistry and hematology devices at two outpatient clinics via middleware software to the central electronic health record (EHR), facilitating a comparison of manual transcription versus automatic reporting via interface. This allowed for estimation of serious/obvious error rates and manual time savings. Additional goals were to develop autoverification rules and analyze broad trends of results in response to common clinician complaints on the POC testing. MATERIAL AND METHODS: Data were obtained from two satellite clinic sites providing both primary and urgent care within an academic health system. Interface of devices was accomplished via Instrument Manager middleware software and occurred approximately halfway through the 38 month retrospective timeframe. Laboratory results for three testing POC chemistry and hematology panels were extracted with EHR tools. RESULTS: Nearly 100,000 lab values were analyzed and revealed that the rate of laboratory values outside reference range was essentially unchanged before and after interface of POC testing devices (2.0-2.1%). Serious/obvious errors, while rare overall, declined significantly, with none recorded after the interface with autoverified results and only three related to manual edits of results that failed autoverification. Fewer duplicated test results were identified after the interface, most notably with the hematology testing. Anion gap values of less than zero were observed more frequently in POC device tests when compared to central laboratory tests and are attributed to a higher proportion of Cl values greater than 110 mEq/L and CO2 values greater than 30 mEq/L with POC results. Time savings of eliminating manual data entry were calculated to be 21.6 employee hours per month. CONCLUSIONS: In a switch from manual entry to automatic interface for POC chemistry and hematology, the most notable changes were reduction of serious/obvious errors and duplicate results. Significant time employee time savings highlight an additional benefit of instrument interfacing. Lastly, a difference between POC and central laboratory instruments is a higher rate of high Cl and CO2 values relative to the central laboratory.

4.
Springerplus ; 4: 760, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26682113

RESUMO

The measurement of free immunoglobulin light chains is typically performed on serum; however, the use of alternative specimen types has potential benefits. Using the Freelite™ kappa and lambda free light chains assay on a Roche Diagnostics cobas 8000 c502 analyzer, we compared three specimen types (serum, EDTA-plasma and lithium heparin plasma separator gel-plasma) on 100 patients. Using Deming regression and eliminating outliers (limiting data to light chain concentrations below 400 mg/L), the three specimen types showed comparable results for kappa light chain concentration, lambda light chain concentration, and kappa/lambda ratio with slopes close to 1.0 and y-intercepts close to zero. EDTA-plasma showed slightly more positive bias relative to serum than lithium heparin. Analysis using EDTA-plasma and lithium heparin plasma showed comparable linearity, precision, and temperature stability. A single sample showing hook effect (not in the comparison set) gave comparable results using either plasma specimen type. For the Freelite™ kappa and lambda free light chains assay, both EDTA-plasma or lithium heparin-plasma can serve as acceptable substitutes for serum, at least for the Roche cobas 8000 analyzer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA