Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(11): 2250-2260, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35989543

RESUMO

INTRODUCTION: Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator- and center-dependent. This study sought to evaluate a novel machine learning software algorithm named VX1 (Volta Medical), trained to adjudicate multipolar electrogram dispersion. METHODS: This study was a prospective, multicentric, nonrandomized study conducted to assess the feasibility of generating VX1 dispersion maps. In 85 patients, 8 centers, and 17 operators, we compared the acute and long-term outcomes after ablation in regions exhibiting dispersion between primary and satellite centers. We also compared outcomes to a control group in which dispersion-guided ablation was performed visually by trained operators. RESULTS: The study population included 29% of long-standing persistent AF. AF termination occurred in 92% and 83% of the patients in primary and satellite centers, respectively, p = 0.31. The average rate of freedom from documented AF, with or without antiarrhythmic drugs (AADs), was 86% after a single procedure, and 89% after an average of 1.3 procedures per patient (p = 0.4). The rate of freedom from any documented atrial arrhythmia, with or without AADs, was 54% and 73% after a single or an average of 1.3 procedures per patient, respectively (p < 0.001). No statistically significant differences between outcomes of the primary versus satellite centers were observed for one (p = 0.8) or multiple procedures (p = 0.4), or between outcomes of the entire study population versus the control group (p > 0.2). Interestingly, intraprocedural AF termination and type of recurrent arrhythmia (i.e., AF vs. AT) appear to be predictors of the subsequent clinical course. CONCLUSION: VX1, an expertise-based artificial intelligence software solution, allowed for robust center-to-center standardization of acute and long-term ablation outcomes after electrogram-based ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Inteligência Artificial , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Software , Veias Pulmonares/cirurgia , Recidiva
2.
Pacing Clin Electrophysiol ; 44(1): 135-144, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33283875

RESUMO

INTRODUCTION: Causes of non-response to cardiac resynchronization therapy (CRT) include mechanical dyssynchrony, myocardial scar, and suboptimal left ventricular (LV) lead location. We aimed to assess the utility of Late Iodine Enhancement Computed Tomography (LIE-CT) with image subtraction in characterizing CRT non-response. METHODS: CRT response was defined as a decrease in LV end-systolic volume > 15% at 6 months. LIE-CT was performed after 6 months, and analyzed global and segmental dyssynchrony, myocardial scar, coronary venous anatomy, and position of LV lead relative to scar and segment of latest mechanical contraction. RESULTS: We evaluated 29 patients (age 71 ± 12 years; 72% men) including 18 (62%) responders. All metrics evaluating residual dyssynchrony such as wall motion index and wall thickness index were worse in non-responders. There was no difference in presence and extent of scar between responders and non-responders. However, in non-responders, the LV lead was more often over an akinetic/dyskinetic area (72% vs. 22%, p = .007), a fibrotic area (64% vs. 8%, p = .0007), an area with myocardial thickness < 6 mm (82% vs. 22%, p = .002), and less often concordant with the region of maximal wall thickness (9% vs. 72%, p = .001). Among the 11 non-responders, eight had at least another coronary venous branch visualized by CT, including three (27%) coursing over a potentially interesting myocardial area (free of scar, with normal wall motion, and with a myocardial thickness ≥6 mm). CONCLUSION: LIE-CT with image subtraction allows a comprehensive characterization of patients after CRT and may provide clues for management of non-responders.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Tomografia Computadorizada por Raios X , Falha de Tratamento , Idoso , Terapia de Ressincronização Cardíaca , Meios de Contraste , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Técnica de Subtração
3.
Circulation ; 140(4): 293-302, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31155932

RESUMO

BACKGROUND: An accurate estimation of the risk of life-threatening (LT) ventricular tachyarrhythmia (VTA) in patients with LMNA mutations is crucial to select candidates for implantable cardioverter-defibrillator implantation. METHODS: We included 839 adult patients with LMNA mutations, including 660 from a French nationwide registry in the development sample, and 179 from other countries, referred to 5 tertiary centers for cardiomyopathies, in the validation sample. LTVTA was defined as (1) sudden cardiac death or (2) implantable cardioverter defibrillator-treated or hemodynamically unstable VTA. The prognostic model was derived using the Fine-Gray regression model. The net reclassification was compared with current clinical practice guidelines. The results are presented as means (SD) or medians [interquartile range]. RESULTS: We included 444 patients, 40.6 (14.1) years of age, in the derivation sample and 145 patients, 38.2 (15.0) years, in the validation sample, of whom 86 (19.3%) and 34 (23.4%) experienced LTVTA over 3.6 [1.0-7.2] and 5.1 [2.0-9.3] years of follow-up, respectively. Predictors of LTVTA in the derivation sample were: male sex, nonmissense LMNA mutation, first degree and higher atrioventricular block, nonsustained ventricular tachycardia, and left ventricular ejection fraction (https://lmna-risk-vta.fr). In the derivation sample, C-index (95% CI) of the model was 0.776 (0.711-0.842), and the calibration slope 0.827. In the external validation sample, the C-index was 0.800 (0.642-0.959), and the calibration slope was 1.082 (95% CI, 0.643-1.522). A 5-year estimated risk threshold ≥7% predicted 96.2% of LTVTA and net reclassified 28.8% of patients with LTVTA in comparison with the guidelines-based approach. CONCLUSIONS: In comparison with the current standard of care, this risk prediction model for LTVTA in laminopathies significantly facilitated the choice of candidates for implantable cardioverter defibrillators. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03058185.


Assuntos
Cardiomiopatias/complicações , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/etiologia , Adulto , Feminino , Humanos , Masculino , Taquicardia Ventricular/patologia , Estudos de Validação como Assunto
4.
J Cardiovasc Electrophysiol ; 31(9): 2405-2414, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32562444

RESUMO

INTRODUCTION: In cardiac resynchronization therapy, pacing the left ventricle (LV) at sites of prolonged electrical delay is associated with better outcomes. We sought to characterize the interrelationships between intrinsic, right-ventricular (RV)-paced, and LV-paced interventricular delays. METHODS AND RESULTS: The following electrical timings were measured at implantation for all electrodes of the LV quadripolar leads: QLV, interventricular delay in intrinsic rhythm (RVs-LVs), in RV-paced rhythm (RVp-LVs), and in LV-paced rhythm (LVp-RVs). We included 32 patients (78% men, age 72 years, LV ejection fraction 29%, left bundle branch block 84%). QLV and RVs-LVs were correlated (R2 = .72, p < .0001), as were RVs-LVs and RVp-LVs (R2 = .27, p = .002) and RVp-LVs and LVp-RVs (R2 = .60, p < .001). Direction of activation along the four LV lead electrodes was concordant between RVs-LVs and RVp-LVs in only 17 (53%) patients. The latest-activated electrodes in RVs-LVs and RVp-LVs were concordant in 26 (81%) patients, adjacent in 3 (9%) patients, and remote in 3 (9%) patients. Biventricular-paced QRS duration varied by more than 10 ms between the two electrodes in half of the patients with dissimilar latest electrodes. Among the seven echocardiographic nonresponders at 6 months, the programmed electrode was remote from the latest electrode in RVs-LVs in five patients and in RVp-LVs in three patients. CONCLUSION: Intrinsic and RV-paced interventricular electrical delays are correlated, but there is substantial heterogeneity between patients. The latest-activated electrode may be different between RVs-LVs and RVp-LVs, and this might have important implications in selecting the optimal LV vector.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Resultado do Tratamento , Função Ventricular Esquerda
5.
Pacing Clin Electrophysiol ; 41(4): 362-367, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29405324

RESUMO

BACKGROUND: Cardiac resynchronization therapy optimization can be pursued by left ventricular pacing vector selection and atrioventricular (AV) and interventricular (VV) delays optimization. The combination of these methods and its comparison with multipoint pacing (MPP) is scarcely studied. METHODS: Using noninvasive cardiac output (CO) measurement, the best of five left ventricular pacing vectors was determined, then AV and VV delays optimization was applied on top of the best vector. Response to the optimization protocol was defined as a >5% CO increase compared to the standard biventricular configuration. RESULTS: Twenty-two patients (18 men, age 71 ± 9 years) were included. Standard biventricular configuration increased CO compared to baseline (4.65 ± 1.55 L/min vs 4.27 ± 1.53 L/min, respectively, P = 0.02). The best quadripolar configuration increased CO to 4.85 ± 1.67 L/min (P = 0.03 compared to the standard biventricular configuration). AV then VV delay optimization both provided additional benefit (final CO 5.56 ± 2.03 L/min, P = 0.001 compared to the best quadripolar configuration). Fifteen (68%) patients responded to the optimization protocol. Anatomical MPP (based on maximal anatomical separation between electrodes) and electrical MPP (based on maximal electrical activation difference between electrodes) were evaluated in 16 patients and yielded a CO similar to that of the optimization procedure. CONCLUSIONS: The combination of choosing the best quadripolar pacing configuration and optimizing atrioventricular and interventricular delays resulted in an improvement of cardiac output compared to standard biventricular stimulation in 68% of patients. The final cardiac output was comparable to multipoint pacing.


Assuntos
Nó Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/prevenção & controle , Insuficiência Cardíaca/fisiopatologia , Idoso , Débito Cardíaco , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Humanos , Masculino , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
6.
J Electrocardiol ; 51(3): 531-533, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29273233

RESUMO

The eligibility for subcutaneous implantable cardioverter-defibrillators (S-ICD) was assessed among patients already implanted with cardiac resynchronization therapy (CRT). We included 20 patients (15 men, age 73±10years, LVEF 35±10%). Seventeen (85%) patients were eligible for S-ICDs: 11 (55%) patients on only 1 vector and 6 (30%) patients on 2 or 3 vectors. Patients who were eligible on 2-3 vectors had narrower paced QRS than patients who were not eligible or were eligible on only one vector (133±18ms vs 167±17ms, p=0.007). If necessary, S-ICD implantation could be considered in most patients with CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Seleção de Pacientes , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Resultado do Tratamento
8.
Cardiovasc Digit Health J ; 4(5): 149-154, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37850045

RESUMO

Background: Cardiac implantable electronic devices (CIEDs) are an important means of atrial fibrillation (AF) detection. However, the AF burden measurements and notifications transmitted by CIEDs are not directly related to the clinical classification of paroxysmal, persistent, or permanent AF. Moreover, AF alerts are the most frequent form of notification, imposing a time-consuming review on caregivers. Objective: The purpose of this study was to compare the incidence of standard AF burden-related notifications in remotely monitored (RM) patients with the incidence of events detected after filtering by a new proprietary algorithm implementing the standard European Society of Cardiology classification of AF. Methods: Between 2017 and 2022, all RM patients with daily AF burden measurements available for ≥30 days and ≥1 AF burden-related alerts were enrolled at 68 medical centers. The incidence of CIED-transmitted alerts was compared to that of AF episodes detected by a new proprietary algorithm and classified as "first recorded episode of AF", "paroxysmal AF", "increased paroxysmal AF", "persistent AF", or "end of persistent AF back to paroxysmal AF or back to sinus rhythm." Results: Between January 2017 and September 2022, this retrospective study analyzed data from 4162 recipients of an Abbott, Biotronik, Boston Scientific, or Medtronic CIED, RM over mean follow-up of 605 ± 386 days. The algorithm broke down 67,883 AF burden-related alerts into 9728 (14.3%) clinically relevant AF events. Conclusion: A new AF alert algorithm successfully identified clinically significant AF events in RM CIED recipients and would markedly limit the total number of transmitted alerts that require review by caregivers.

9.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
10.
Ann Noninvasive Electrocardiol ; 17(4): 372-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23094883

RESUMO

BACKGROUND: Centenarians have been proposed as a model of successful aging but recent studies suggest a high prevalence of cardiovascular diseases. Some findings on their electrocardiograms (ECGs) are simply age-related and others mirror underlying diseases. We aimed to identify ECG features truly associated with extreme age. METHODS: Retrospective analysis of 55 centenarians hospitalized between January 2000 and June 2010. Each centenarian was matched with three octogenarians according to gender, presence of hypertension, aortic stenosis, heart failure, and ischemic heart disease. RESULTS: A history of hypertension was present in 32 (58%) centenarians, aortic stenosis in 6 (11%), heart failure in 8 (15%), and ischemic heart disease in 6 (11%). Centenarians had a higher heart rate than octogenarians (81 ± 15 bpm vs. 72 ± 15 bpm, respectively, P < 0.001) but were less frequently on beta-blockers (7% vs. 36%, respectively, P < 0.001). Centenarians displayed more frequently atrial premature beats than octogenarians (18% vs. 3%, respectively, P < 0.001) but tended to have less atrial fibrillation (15% vs. 22% respectively, P = 0.21). Centenarians had more frequently left QRS axis deviation (48% vs. 28%, P = 0.009) and Q waves (14% vs. 1%, P = 0.02). QT interval was more prolonged in centenarians (446 ± 42 ms vs. 429 ± 39 ms, P = 0.008). Two centenarians (4%) and 24 (15%) octogenarians had a strictly normal ECG (P = 0.02). CONCLUSIONS: Abnormal ECG is a common finding in centenarians, with different characteristics than in younger elderly individuals. These differences are unrelated to the presence of cardiac diseases.


Assuntos
Eletrocardiografia/estatística & dados numéricos , Avaliação Geriátrica/métodos , Avaliação Geriátrica/estatística & dados numéricos , Cardiopatias/epidemiologia , Cardiopatias/fisiopatologia , Frequência Cardíaca , Fatores Etários , Idoso de 80 Anos ou mais , Arritmias Cardíacas , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Paris/epidemiologia , Estudos Retrospectivos
11.
JACC Clin Electrophysiol ; 8(1): 41-48, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34454885

RESUMO

OBJECTIVES: The aim of this study was to assess the persistence of left atrial (LA) lesions created by ethanol infusion in the vein of Marshall (EIVM) by electroanatomical mapping on repeat catheter ablation for recurrent atrial tachyarrhythmia. BACKGROUND: Little is known about the durability of LA lesions created by EIVM. METHODS: The study included consecutive patients who underwent EIVM for persistent atrial fibrillation or perimitral LA flutter (index procedure) and repeat catheter ablation for recurrent atrial tachyarrhythmia or atrial fibrillation at a single center between January 2019 and April 2020. The acute effect of EIVM was assessed at the index procedure by comparing the area of bipolar voltage <0.05 mV in the vein of Marshall (VOM) region before and immediately after EIVM. The long-term effect of EIVM was assessed by comparing this area in the VOM region between the redo procedure and the index procedure. RESULTS: Twenty-four consecutive patients (mean age 68.6 ± 6.1 years, 58% men) underwent redo procedures after previous EIVM for persistent atrial fibrillation (n = 21 [88%]) or perimitral LA flutter (n = 5 [21%]). In each patient, the EIVM-related lesion persisted, with a chronic scar in the VOM region (median 13.1 cm2 [interquartile range: 8.1-15.9 cm2] vs 12.4 cm2 [interquartile range: 7.6-15.7 cm2] acutely, respectively). One quarter of patients (9 of 20) had late mitral isthmus reconnection, which was located at the mitral annular edge or in the coronary sinus. CONCLUSIONS: Atrial lesions created by EIVM are durable, which reinforces the efficacy profile of EIVM. Reconduction sites in the mitral isthmus are located at the edge of the scar and in the coronary sinus.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Etanol/uso terapêutico , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
12.
EuroIntervention ; 18(1): 50-57, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-34794937

RESUMO

BACKGROUND: Although the presence of a thrombus contraindicates left atrial appendage closure procedure (LAAC), a previous study reported the feasibility of the thrombus trapping procedure (TTP) technique to overcome this limitation. AIMS: This study aimed to analyse the short-term outcomes in a series of patients who underwent LAAC using the TTP (TTP-LAAC). METHODS: This retrospective series included patients who underwent TTP-LAAC between January 2018 and May 2020 in 13 European centres. Device choice, pre-interventional work-up and post-discharge antithrombotic therapy regimens were left to the discretion of the operators. The primary endpoint was the 30-day occurrence of stroke, systemic embolism or cardiovascular death. RESULTS: During the study period, a total of 1,918 patients underwent LAAC. A thrombus was identified in 71 cases but completely disappeared in 24 patients before procedure. TTP-LAAC was finally performed in 53 cases (3%). Thrombi were identified ahead of the actual day of implantation in 47 patients (87%) and were mostly limited in size (50 cases with extension <50% of the LAA surface). The Amplatzer Amulet and WATCHMAN FLX occluders were implanted in 44 and 9 patients, respectively. A single deployment approach was applied in 70% and a cerebral embolic protection system was used in 9% of the patients. The overall success rate was 100%. Small pericardial effusion without tamponade was observed in 6% of the cases. Patients were discharged with 72% under antiplatelet therapy and 10% under short-term oral anticoagulation. The primary endpoint occurred in one patient. CONCLUSIONS: TTP-LAAC might be used in a minority of LAAC procedures but appears to be feasible and safe in the short-term, in select cases.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Trombose , Assistência ao Convalescente , Apêndice Atrial/cirurgia , Humanos , Alta do Paciente , Sistema de Registros , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/cirurgia , Resultado do Tratamento
13.
Resuscitation ; 179: 197-205, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35788021

RESUMO

BACKGROUND: Since majority of sudden cardiac arrest (SCA) victims die in the intensive care unit (ICU), early etiologic investigations may improve understanding of SCA and targeted prevention. METHODS: In this prospective, population-based registry all SCA admitted alive across the 48 hospitals of the Paris area were enrolled. We investigated the extent of early etiologic work-up among young SCD cases (<45 years) eventually dying within the ICU. RESULTS: From May 2011 to May 2018, 4,314 SCA patients were admitted alive. Among them, 3,044 died in ICU, including 484 (15.9%) young patients. SCA etiology was established in 233 (48.1%) and remained unexplained in 251 (51.9%). Among unexplained (compared to explained) cases, coronary angiography (17.9 vs. 49.4%, P < 0.001), computed tomography scan (24.7 vs. 46.8%, P < 0.001) and trans-thoracic echocardiography (31.1 vs. 56.7%, P < 0.001) were less frequently performed. Only 22 (8.8%) patients with unexplained SCD underwent all three investigations. SCDs with unexplained status decreased significantly over the 7 years of the study period (from 62.9 to 35.2%, P = 0.005). While specialized TTE and CT scan performances have increased significantly, performance of early coronary angiography did not change. Autopsy, genetic analysis and family screening were performed in only 48 (9.9%), 5 (1.0%) and 14 cases (2.9%) respectively. CONCLUSIONS: More than half of young SCD dying in ICU remained etiologically unexplained; this was associated with a lack of early investigations. Improving early diagnosis may enhance both SCA understanding and prevention, including for relatives. Failure to identify familial conditions may result in other preventable deaths within these families.


Assuntos
Morte Súbita Cardíaca , Parada Cardíaca , Autopsia , Angiografia Coronária/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Parada Cardíaca/complicações , Humanos , Estudos Prospectivos
14.
J Med Ethics ; 37(2): 101-4, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21160080

RESUMO

AIM: Facebook is an increasingly popular online social networking site. The purpose of this study was to describe the Facebook activity of residents and fellows and their opinions regarding the impact of Facebook on the doctor-patient relationship. METHODS: An anonymous questionnaire was emailed to 405 residents and fellows at the Rouen University Hospital, France, in October 2009. RESULTS: Of the 202 participants who returned the questionnaire (50%), 147 (73%) had a Facebook profile. Among responders, 138 (99%) displayed their real name on their profile, 136 (97%) their birthdates, 128 (91%) a personal photograph, 83 (59%) their current university and 76 (55%) their current position. Default privacy settings were changed by 61% of users, more frequently if they were registered for >1 year (p=0.02). If a patient requested them as a 'friend', 152 (85%) participants would automatically decline the request, 26 (15%) would decide on an individual basis and none would automatically accept the request. Eighty-eight participants (48%) believed that the doctor-patient relationship would be altered if patients discovered that their doctor had a Facebook account, but 139 (76%) considered that it would change only if the patient had open access to their doctor's profile, independent of its content. CONCLUSIONS: Residents and fellows frequently use Facebook and display personal information on their profiles. Insufficient privacy protection might have an impact the doctor-patient relationship.


Assuntos
Internet/estatística & dados numéricos , Corpo Clínico Hospitalar/ética , Pacientes/psicologia , Relações Médico-Paciente/ética , Revelação da Verdade/ética , França , Humanos , Internato e Residência , Relações Interpessoais , Corpo Clínico Hospitalar/estatística & dados numéricos , Apoio Social , Inquéritos e Questionários
15.
J Interv Card Electrophysiol ; 62(2): 347-356, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33128179

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) devices have multiple programmable pacing parameters. The purpose of this study was to determine the best pacing mode, i.e., associated with the greatest acute hemodynamic response, in each patient. METHODS: Patients in sinus rhythm and intact atrioventricular conduction were included within 3 months of implantation of devices featuring SyncAV and multipoint pacing (MPP) algorithms. The effect of nominal biventricular pacing using the latest activated electrode (BiV-Late), optimized atrioventricular delay (AVD), nominal and optimized SyncAV, and anatomical MPP was determined by non-invasive measurement of systolic blood pressure (SBP). CRT response was defined as SBP increase > 10% relative to baseline. RESULTS: Thirty patients with left bundle branch block (LBBB) were included. BiV-Late increased SBP compared to intrinsic rhythm (128 ± 21 mmHg vs. 121 ± 22 mmHg, p = 0.0002). The best pacing mode further increased SBP to 140 ± 19 mmHg (p < 0.0001 vs. BiV-Late). The proportion of CRT responders increased from 40% with BiV-Late to 80% with the best pacing mode (p = 0.0005). Compared to BiV-Late, optimized AVD and optimized SyncAV increased SBP (to 134 ± 21 mmHg, p = 0.004, and 133 ± 20 mmHg, p = 0.0003, respectively), but nominal SyncAV and MPP did not. The best pacing mode was variable between patients and was different from nominal BiV-Late in 28 (93%) patients. Optimized AVD was the most frequent best mode, in 14 (47%) patients. CONCLUSION: In patients with LBBB, the best pacing mode was patient-specific and doubled the magnitude of acute hemodynamic response and the proportion of acute CRT responders compared to nominal BiV-Late pacing. TRIAL REGISTRATION: ClinicalTrials.gov : NCT03779802.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Resultado do Tratamento
16.
Ann Cardiol Angeiol (Paris) ; 70(5): 312-316, 2021 Nov.
Artigo em Francês | MEDLINE | ID: mdl-34548128

RESUMO

This survey evaluated hypnosis practice in French centres in June 2020. The survey was sent via email to different rhythmology centres in France and responses from cardiologists and nurses were obtained. We present here the preliminary results of this survey. Hypnosis was used on a regular basis in 7.5% of the centres and 13% of the participants received education on hypnosis. 75% of the participants were interested to have an education of hypnosis. The survey points the different possibilities of improvement of management of patients while having the different procedures.


Assuntos
Hipnose , França/epidemiologia , Humanos , Inquéritos e Questionários
17.
J Interv Card Electrophysiol ; 60(2): 313-319, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32621214

RESUMO

BACKGROUND: High-density automated mapping of complex atrial tachycardias (ATs) requires accurate assessment of activation maps. A new local activation display module (HD coloring, Biosense Webster®) provides higher map resolution, a better delineation of potential block reducing color interpolation, and a new propagation display. We evaluated the accuracy of a dedicated local activation display compared with standard algorithm. METHODS: High-density maps from 10 AT were collected with a multipolar catheter and were displayed with standard activation or HD coloring. Six expert operators retrospectively analyzed activation maps and were asked to define (1) the tachycardia mechanism, (2) ablation target, and (3) level of difficulty to interpret those maps. RESULTS: Using HD coloring, operators were able to reach a correct diagnosis in 93% vs. 63%, p < 0.05 compared to standard activation maps. Time to diagnosis was shorter 1.9 ± 1.0 min vs. 3.9 ± 2.1 min, p < 0.05. Confidence level would have allowed ablation without necessity for entrainment maneuvers in 87% vs. 53%, p < 0.05. Operators would have needed to remap or proceed with multiple entrainments in 3% vs. 13% of cases, p < 0.05. Finally, ablation strategy was more accurately identified in 97% vs. 67%, p < 0.05. CONCLUSION: Activation mapping with the new HD coloring module allowed a more accurate, reliable, and faster interpretation of complex ATs mechanisms compared to standard activation maps.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Retrospectivos , Taquicardia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia
18.
ESC Heart Fail ; 7(3): 1302-1308, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32157825

RESUMO

AIMS: Echocardiographic measures of dyssynchrony at baseline have not demonstrated a good ability to predict response to cardiac resynchronization therapy (CRT). The purpose of this study was to determine if the acute correction of electromechanical dyssynchrony, assessed by the change in simple pulsed-Doppler measures, was related to CRT response at 6 months. METHODS AND RESULTS: Echocardiography was performed at baseline and at pre-discharge after CRT implantation. Intraventricular, interventricular, and atrioventricular dyssynchrony were evaluated by the left pre-ejection interval (LPEI), the interventricular mechanical delay, and the ratio of left ventricular filling time to RR interval, respectivelxy. A patient was considered responder if he/she was alive without hospitalization for heart failure and had an absolute increase of left ventricular ejection fraction (LVEF) >5 points. Forty-eight patients (mean age 67 ± 11 years, 73% male, mean LVEF 30 ± 5%) were included. CRT led to an acute correction of intraventricular and interventricular dyssynchrony but not to an acute correction of atrioventricular dyssynchrony. There were 31 (65%) responders at 6 months. Two factors were independently associated with CRT response in multivariate analysis: ischemic cardiomyopathy (odds ratio 0.19, 95% confidence interval 0.04-0.87; P= 0.032) and delta LPEI (odds ratio 1.03 per 1 ms decrease, 95% confidence interval 1.01-1.05; P = 0.007). By receiver operating characteristic analysis, the optimal cut-off value of delta LPEI was -16 ms. The proportion of responders in patients without ischemic cardiomyopathy and with a delta LPEI greater than -16 ms was 85%. CONCLUSIONS: Acute correction of intraventricular electromechanical dyssynchrony evaluated by the LPEI predicted CRT response at 6 months.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
19.
Arch Cardiovasc Dis ; 113(12): 791-796, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33051170

RESUMO

BACKGROUND: The success rate of cavotricuspid isthmus ablation to treat right common flutter is high (up to 95%), but needs bidirectional block confirmation, requiring two or three catheters. AIM: To describe a new pacing technique using a single catheter to ablate and confirm cavotricuspid isthmus block with differential PR interval measurements. METHODS: We included 61 patients from five centres, who were referred for cavotricuspid isthmus ablation. All patients had cavotricuspid isthmus ablation, and the cavotricuspid isthmus block was confirmed by differential pacing using two or three catheters. The new method consisted of measuring the PR interval on the surface electrocardiogram using pacing from the tip of the ablation catheter on the lateral side (lateral delay) and the septal side (coronary sinus ostium) of the cavotricuspid isthmus line (difference=delta PR interval), before and after cavotricuspid isthmus ablation. We analysed the value of the delta PR interval in predicting bidirectional cavotricuspid isthmus block as confirmed by standard methods. RESULTS: Among our patient population (mean age 63±12 years), 39 patients were ablated during sinus rhythm, and 22 during common flutter. Cavotricuspid isthmus block was achieved in all patients but one. Lateral delay and delta PR interval increased significantly after validation of cavotricuspid isthmus block (257±42 vs. 318±50ms and 32±23 vs. 96±22ms, respectively; P<0.0001). A delta PR interval cut-off of ≥70ms had 100% sensitivity and specificity to predict bidirectional cavotricuspid isthmus block. CONCLUSIONS: A single-catheter ablation approach to performing cavotricuspid isthmus line based on surface electrocardiogram PR interval measurement is feasible. After ablation, cavotricuspid isthmus block was systematically obtained when the delta PR interval was>70ms.


Assuntos
Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Eletrocardiografia/instrumentação , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
20.
Arch Cardiovasc Dis ; 112(3): 153-161, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30594571

RESUMO

BACKGROUND: Long PR intervals may increase cardiovascular complications, including atrial fibrillation. In pacemakers, the SafeR™ mode monitors PR intervals, switching from AAI to DDD when criteria for atrioventricular block are met. AIMS: The PRECISE study evaluated the incidence and predictors of long PR intervals and their association with incident atrial fibrillation after 1 year in patients implanted for sinus node dysfunction and free from significant conduction disorders at baseline. METHODS: This French, prospective, multicentre, observational trial enrolled patients implanted with a REPLY™ dual-chamber pacemaker. Pacemaker memory recorded long PR intervals (defined as first-degree atrioventricular block mode switches occurring after six consecutive PR/AR intervals≥350/450ms) and atrial fibrillation incidence (fallback mode switch>1minute/day). Predictors were identified from baseline variables (age, sex, AR and PR intervals, atrial rhythm disorder and medication) using logistic regression. RESULTS: Of 291 patients with sinus node dysfunction enrolled, 214 were free from significant conduction disorders at baseline (mean age 79±8 years; 44% men; PR/AR intervals<350/450ms). After 1 year, long PR intervals had occurred in 116 patients (54%) and atrial fibrillation in 63 patients (30%). Amiodarone was the only independent predictor of long PR interval occurrence (odds ratio 2.50, 95% confidence interval 1.20-5.21; P=0.014). There was a strong trend towards an association between long PR interval and atrial fibrillation incidence (odds ratio 1.86, 95% confidence interval 0.97-3.61; P=0.051). CONCLUSIONS: Half of the patients with pure sinus node dysfunction developed long PR intervals in the year following pacemaker implantation. Amiodarone was the only independent predictor of long PR intervals. There was a strong trend towards an association between long PR intervals and incident atrial fibrillation.


Assuntos
Estimulação Cardíaca Artificial , Frequência Cardíaca , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Nó Sinoatrial/fisiopatologia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/fisiopatologia , Desenho de Equipamento , Feminino , França/epidemiologia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/epidemiologia , Síndrome do Nó Sinusal/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA