Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(19)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37836921

RESUMO

Recent advances allow the use of Augmented Reality (AR) for many medical procedures. AR via optical navigators to aid various knee surgery techniques (e.g., femoral and tibial osteotomies, ligament reconstructions or menisci transplants) is becoming increasingly frequent. Accuracy in these procedures is essential, but evaluations of this technology still need to be made. Our study aimed to evaluate the system's accuracy using an in vitro protocol. We hypothesised that the system's accuracy was equal to or less than 1 mm and 1° for distance and angular measurements, respectively. Our research was an in vitro laboratory with a 316 L steel model. Absolute reliability was assessed according to the Hopkins criteria by seven independent evaluators. Each observer measured the thirty palpation points and the trademarks to acquire direct angular measurements on three occasions separated by at least two weeks. The system's accuracy in assessing distances had a mean error of 1.203 mm and an uncertainty of 2.062, and for the angular values, a mean error of 0.778° and an uncertainty of 1.438. The intraclass correlation coefficient was for all intra-observer and inter-observers, almost perfect or perfect. The mean error for the distance's determination was statistically larger than 1 mm (1.203 mm) but with a trivial effect size. The mean error assessing angular values was statistically less than 1°. Our results are similar to those published by other authors in accuracy analyses of AR systems.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Reprodutibilidade dos Testes , Fêmur/cirurgia , Cirurgia Assistida por Computador/métodos , Osteotomia
2.
Knee Surg Sports Traumatol Arthrosc ; 29(9): 2934-2939, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33033845

RESUMO

PURPOSE: The aim of the study was to translate and validate the English version of the 'Knee Society Knee Scoring System' developed in 2011 (2011 KSS) into Spanish. This new KSS version considers patient satisfaction and expectations before and after knee arthroplasty. Moreover, the questionnaire allows a better characterization of a younger and more diverse population. METHODS: A cross-cultural adaptation process was carried out to obtain the Spanish version of the questionnaire. After that, patients undergoing primary knee arthroplasty answered the translated questionnaire before and 6 months after surgery. Psychometric properties including feasibility, validity, reliability, and sensitivity to change were then assessed, and the questionnaire was compared with prior KSS, as well as with SF-12 and WOMAC, all of them already validated to Spanish. RESULTS: In the cross-cultural adaptation process, alternative translations of some items in 'Patient Expectative' and 'Functional Activities' sections were suggested. One hundred and seventy-six patients answered the resulting 1.0 version. Feasibility: 'Charnley Functional Classification', 'Deduction for flexion contracture and extensor lag', the question 'Do you use these aids because of your knees?', and 'Advanced activities (total)' obtained a high number of missing items. Eighty-eight patients (50%) in the preoperative visit and 141 patients (86.5%) after surgery had at least one missing answer. Internal validity: although the analysis suggests the presence of more than one dimension, there was a dimension that explained a higher percentage of variance, which was more noticeable in the postoperative visit. Convergent validity: correlation coefficients with prior KSS, SF-12, and WOMAC confirm the questionnaire's validity. Reliability: Cronbach's alpha for the new KSS was 0.841 and 0.861 in visit 1 and 2, respectively, and higher than that for prior KSS. Sensitivity to change: statistically, significant differences were found between the mean scores between both visits. CONCLUSION: The proposed Spanish version of 2011 KSS is valid, reliable, and sensible to change in patients undergoing primary knee arthroplasty. Moreover, it has higher internal consistency (reliability) than the prior KSS. It should be emphasized its correct filling by both health professional and patients LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários , Traduções
3.
J Clin Med ; 13(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38929951

RESUMO

Background: Instability is a common cause of (total knee arthroplasty) TKA failure, which can be prevented by achieving proper gap balance during surgery. There is no consensus on the ideal gap balance in TKA, and different alignment philosophies result in varying soft-tissue tightness. Traditional TKA aims for symmetric compartment balance, while kinematic alignment (KA) restores anatomy and accepts asymmetric flexion gaps. This study evaluated the impact of these philosophies on the flexion gap balance and clinical outcomes. Methods: A retrospective review of 167 patients who received true or restricted KA robotic-assisted TKA with at least one year of follow-up was conducted. The groups were based on intraoperative flexion gap differences: symmetric (0-1 mm) (n = 94) and asymmetric (2-5 mm) (n = 73). Results: Preoperative demographics and postoperative clinical and functional scores were compared. Both groups were similar in demographics and preoperative scores. True KA alignment was more likely to result in an asymmetric flexion gap, while restricted KA produced symmetric gaps. Conclusions: The study found no adverse effects from the physiological asymmetric flexion gap, with clinical and functional outcomes comparable to symmetric gaps. A 5 mm difference between the medial and lateral gap width did not negatively impact the outcomes. True KA more frequently results in a physiological asymmetric flexion gap.

4.
Arthrosc Tech ; 12(10): e1827-e1836, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37942102

RESUMO

The elbow is one of the most commonly dislocated joints. While conservative management is frequently performed for simple elbow dislocations, the importance of primary surgical treatment is still undetermined. However, promising results have been reached after surgical repair. We propose an arthroscopic surgical repair of the lateral ligament complex (LCL), performed with a horizontal suture and 2 Fibertak Knotless implants (Arthrex) placed on the LCL origin, one anterior and the other posterior. Operative treatment should be performed in patients with moderate and gross elbow laxity to avoid post-traumatic sequelae and decrease revision rates. Arthroscopic techniques create fewer complications. This procedure allows one to address intra-articular elbow joint pathology with less chance of wound complications and the ability to use bone anchors if desired.

5.
J Pers Med ; 13(5)2023 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-37241038

RESUMO

The aims of this study were to evaluate the outcomes of patients undergoing kinematic alignment (KA) robot-assisted (RA) total knee arthroplasty (TKA) with and without preoperative fixed flexion contracture (FFC) and address whether additional resection of the proximal tibia is required to address FFC. A retrospective review from 147 consecutive patients who received an RA-TKA with KA and a minimum one-year follow-up was performed. Preop and postop clinical and surgical data were collected. Groups were set based on preoperative extension deficits: group 1 (0-4°) (n = 64), group 2 (5-10°) (n = 64) and group 3 (>11°) (n = 27). There were no differences in patient demographics among the three groups. In group 3, the mean tibia resection was 0.85 mm thicker than group 1 (p < 0.05) and the preoperative extension deficit was improved from -17.22° (SD 3.49) preop to -2.41° (SD 4.47) postop (p < 0.05). Our results demonstrate that FFC can successfully be addressed in the RA-TKA with KA and rKA and that no additional femoral bone resection is needed to achieve full extension in patients with preoperative FFC when compared with patients without FFC. Only a slight increase in the amount of tibial resection was observed, but this was less than one millimetre.

6.
J Pers Med ; 13(5)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37240897

RESUMO

Computer technologies play a crucial role in orthopaedic surgery and are essential in personalising different treatments. Recent advances allow the usage of augmented reality (AR) for many orthopaedic procedures, which include different types of knee surgery. AR assigns the interaction between virtual environments and the physical world, allowing both to intermingle (AR superimposes information on real objects in real-time) through an optical device and allows personalising different processes for each patient. This article aims to describe the integration of fiducial markers in planning knee surgeries and to perform a narrative description of the latest publications on AR applications in knee surgery. Augmented reality-assisted knee surgery is an emerging set of techniques that can increase accuracy, efficiency, and safety and decrease the radiation exposure (in some surgical procedures, such as osteotomies) of other conventional methods. Initial clinical experience with AR projection based on ArUco-type artificial marker sensors has shown promising results and received positive operator feedback. Once initial clinical safety and efficacy have been demonstrated, the continued experience should be studied to validate this technology and generate further innovation in this rapidly evolving field.

7.
J Pers Med ; 13(5)2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37240966

RESUMO

A shallow sulcus characterizes trochlear dysplasia (TD) of the femoral trochlea, which can lead to chronic pain or instability of the patellofemoral joint. Breech presentation at birth has been identified as a risk factor for developing this condition, which an ultrasound can identify early. Early treatment could be considered at this stage, given the potential for remodelling in these skeletally immature patients. Newborns with breech presentation at birth who meet the inclusion criteria will be enrolled and randomised in equal proportions between treatment with the Pavlik harness and observation. The primary objective is to determine the difference in the means of the sulcus angle between the two treatment arms at two months. Ours is the first study protocol to evaluate an early non-invasive treatment for TD in the newborn with breech presentation at birth using a Pavlik harness. We hypothesised that trochlear dysplasia could be reverted when identified and treated early in life with a simple harness, as it is done with developmental dysplasia of the hip.

8.
Rev Esp Patol ; 55(2): 125-134, 2022.
Artigo em Espanhol | MEDLINE | ID: mdl-35483768

RESUMO

INTRODUCTION AND OBJECTIVES: The Paris System (PS) has replaced the classical Papanicolaou System (PapS) in reporting urine cytology, due to its improved sensitivity and negative predictive value (NPV) without loss of specificity. Furthermore, it has enabled the risk of malignancy to be established in each cytological category. The aim of this study is to compare the Paris System with previous results and determine the changes in sensitivity, specificity, positive predictive value, NPV and risk of malignancy in our centre, MATERIALS AND METHODS: Evaluation of the diagnostic power of urine cytology by means of a retrospective cohort study, comparing two series of 400 cytological studies, one using the Papanicolaou System and the other the Paris System. RESULTS: In the detection of high-grade urothelial carcinoma, Paris System has better specificity (93.82% PapS vs 98.64% PS; P=.001) and PPV (39.5% PapS vs 70.6% PS; P=.044) than Papanicolaou System, without changes in sensitivity (53.5% PapS vs 37.5% PS; P=.299) or NPV (96.4% PapS vs 94.8% PS; P=.183). The risk of malignancy for the atypical category increases from low to high levels (1.6% PapS vs 40.0% PS; P=.001); the other categories showed no significant statistical changes. CONCLUSION: The Paris System improves specificity and positive predictive value and establishes a better indication of risk of malignancy for each category, enabling specific clinical management in each case.


Assuntos
Carcinoma de Células de Transição , Neoplasias da Bexiga Urinária , Neoplasias Urológicas , Carcinoma de Células de Transição/patologia , Citodiagnóstico , Feminino , Humanos , Masculino , Estudos Retrospectivos , Neoplasias da Bexiga Urinária/patologia , Neoplasias Urológicas/diagnóstico , Neoplasias Urológicas/patologia
9.
Expert Rev Med Devices ; 19(6): 489-497, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35903900

RESUMO

INTRODUCTION: Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) surgery was initially developed to increase accuracy. The potential PSI benefits have expanded in the last decade, and other advantages have been published. However, different authors are critical of PSI and argue that the advantages are not such and do not compensate for the extra cost. This article aims to describe the recently published advantages and disadvantages of PSI. AREAS COVERED: Narrative description of the latest publications related to PSI in accuracy, clinical and functional outcomes, operative time, efficiency, and other benefits. EXPERT OPINION: We have published high accuracy of the system, with a not clinically relevant loss of accuracy, significantly higher precision with PSI than with conventional instruments, and a high percentage of cases in the optimal range and similar to that obtained with computer-assisted navigation, greater imprecision for tibial slope, a significant blood loss reduction, and time consumption, an acceptable and non-significant increase in the cost per procedure, and no difference in complications during hospital admission and at 90 days. We think that PSI will not follow the Scott Parabola and that it will continue to be a valuable type of device in some instances of TKA surgery.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Cirurgia Assistida por Computador , Humanos , Articulação do Joelho/cirurgia , Duração da Cirurgia , Tíbia/cirurgia
10.
J Knee Surg ; 35(5): 574-582, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32898903

RESUMO

Patient-specific instrumentation (PSI) has been introduced to simplify and make total knee arthroplasty (TKA) surgery more precise, effective, and efficient. We performed this study to determine whether the postoperative coronal alignment is related to preoperative deformity when computed tomography (CT)-based PSI is used for TKA surgery, and how the PSI approach compares with deformity correction obtained with conventional instrumentation. We analyzed pre- and post-operative full length standing hip-knee-ankle (HKA) X-rays of the lower limb in both groups using a convention > 180 degrees for valgus alignment and < 180 degrees for varus alignment. For the PSI group, the mean (± SD) pre-operative HKA angle was 172.09 degrees varus (± 6.69 degrees) with a maximum varus alignment of 21.5 degrees (HKA 158.5) and a maximum valgus alignment of 14.0 degrees. The mean post-operative HKA was 179.43 degrees varus (± 2.32 degrees) with a maximum varus alignment of seven degrees and a maximum valgus alignment of six degrees. There has been a weak correlation among the values of the pre- and post-operative HKA angle. The adjusted odds ratio (aOR) of postoperative alignment outside the range of 180 ± 3 degrees was significantly higher with a preoperative varus misalignment of 15 degrees or more (aOR: 4.18; 95% confidence interval: 1.35-12.96; p = 0.013). In the control group (conventional instrumentation), this loss of accuracy occurs with preoperative misalignment of 10 degrees. Preoperative misalignment below 15 degrees appears to present minimal influence on postoperative alignment when a CT-based PSI system is used. The CT-based PSI tends to lose accuracy with preoperative varus misalignment over 15 degrees.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
J Orthop Res ; 40(8): 1794-1800, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34717014

RESUMO

The posterior condylar offset (PCO) has been proposed as a determinant of a postoperative range of motion after total knee arthroplasty, although there is no consensus. This study aimed to demonstrate the error introduced by forcing the femoral rotation to overlap both condyles for the "true" lateral X-ray projection for the PCO measurement. We hypothesize that the angular discrepancy between the posterior femoral cortical reference plane and the posterior condylar axis plane due to rotation invalidates the acquisition of reliable measurements on X-rays. We have measured the PCO in 50 "true" lateral X-rays and compared it with the medial and lateral condyles PCO's assessed on a computed tomography-scan-based three-dimensional (3D) model of each knee. PCO based on the 3D imaging differed significantly between the medial (25.8 ± 3.67 mm) and lateral (16.59 ± 2.92 mm) condyle. Three-dimensional PCO values differ significantly from those determined in the radiographic studies. Also, the mean values of the medial and lateral condyle PCO measurements differed significantly (p < 0.001) with all PCO measurements on radiographs. We have identified a difference between the posterior cortical plane and the posterior condylar axis projections, both on the axial plane with a mean value of 11.23° ± 3.64°. Our data show an interplane discrepancy angle between the posterior femoral diaphyseal cortical and the posterior condylar axis plane (due to the femur's necessary rotation to overlap both condyles) may invalidate the 2D X-ray PCO assessment as a reliable measurement.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Reprodutibilidade dos Testes
12.
Artigo em Inglês | MEDLINE | ID: mdl-35457522

RESUMO

The Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software's validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart. The observers re-measured the same radiographic studies on three separate occasions three months later but on conventional X-ray films. The differences between the mean bias errors (MBE) within the experience groups were statistically significant between the experts (software) and novices (manual) (p < 0.001) and between the novices (software) and novices (manual) (p = 0.005). When measured with the software, the intra-group error in the expert group was MBE = 1.71 ± 0.61° and the intraclass correlation coefficient (ICC (2,1)) = 0.986, and in the novice group, MBE = 1.9 ± 0.67° and ICC (2,1) = 0.97. There was almost a perfect concordance among the two measurement methods, ICC (2,1) = 0.998 and minimum detectable change (MCD95) < 0.4°. Control of the intrinsic error sources enabled obtaining inter- and intra-observer MDC95 < 0.5° in the two experience groups and with the two measurement methods. The computer-aided software TraumaMeter increases the validity and reliability of Cobb angle measurements concerning manual measurement.


Assuntos
Escoliose , Adolescente , Humanos , Radiografia , Reprodutibilidade dos Testes , Projetos de Pesquisa , Escoliose/diagnóstico por imagem , Software , Coluna Vertebral
13.
Quant Imaging Med Surg ; 12(3): 1706-1715, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35284293

RESUMO

Background: Axial vertebral rotation and Cobb's angle are essential parameters for analysing adolescent idiopathic scoliosis. This study's scope evaluates the validity and absolute reliability of application software based on a new mathematical equation to determine the axial vertebral rotation in digital X-rays according to Raimondi's method in evaluators with different degrees of experience. Methods: Twelve independent evaluators with different experience levels measured 33 scoliotic curves in 21 X-rays with the software on three separate occasions, separated one month. Using the same methodology, the observers re-measured the same radiographic studies three months later but on X-ray films and in a conventional way. Results: Both methods show good validity and reliability, and the intraclass correlation coefficients are almost perfect. According to our results, the software increases 1.7 times the validity and 1.9 times the absolute reliability of axial vertebral rotation on digital X-rays according to Raimondi's method, compared to the conventional manual measurement. Conclusions: The intra-group and inter-group agreement of the measurements with the software shows equal or minor variations than with the manual method, among the different measurement sessions and in the three experience groups. There is almost perfect agreement between the two measurement methods, so the equation and the software may be helpful to increase the accuracy in the axial vertebral rotation assessment.

14.
Sci Rep ; 11(1): 7836, 2021 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-33837279

RESUMO

Individualized pre-operative assessment of the patterns of the lower extremity anatomy and deformities in patients undergoing total knee arthroplasty seems essential for a successful surgery. In the present study, we investigated the relationship among the coronal alignment and the rotational profile of the lower extremities in the Caucasian population with end-stage knee osteoarthritis. We conducted a prospective study of 385 knees that underwent a pre-operative three-dimensional computed tomography-based model. The lower extremity alignment was determined (mechanical tibiofemoral or hip-knee-ankle angle, supplementary angle of the femoral lateral distal angle, and proximal medial tibial angle). For each case, the femoral distal rotation (condylar twist angle), the femoral proximal version, and the tibial torsion were determined. As the coronal alignment changed from varus to valgus, the femoral external rotation increased (r = 0.217; p < 0.0005). As the coronal alignment changed from varus to valgus, the external tibial torsion increased (r = 0.248; p < 0.0005). No correlation was found between the global coronal alignment and the femoral version. The present study demonstrates a linear relationship between the coronal alignment and the rotational geometry of the distal femur. This correlation also occurs with the tibial torsion. Perhaps outcomes of total knee arthroplasty surgery might be improved by addressing these deformities as well.


Assuntos
Fêmur/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/etnologia , Tíbia/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , População Branca , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Feminino , Fêmur/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Período Pré-Operatório , Estudos Prospectivos , Rotação , Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Anormalidade Torcional/fisiopatologia
15.
BMJ Case Rep ; 14(11)2021 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-34753729

RESUMO

Primary neuroendocrine tumours of the kidney are rare, and their pathophysiology is uncertain; since their discovery in 1966, they have been described only a few times in the literature. We present a case of a well-differentiated neuroendocrine tumour of the kidney in an asymptomatic patient, which required a multidisciplinary approach by the hospital's team, including precise surgical treatment and an effective radiopathological diagnosis. The patient underwent right radical nephrectomy. During follow-up, he remained asymptomatic, and no metastases or complications were identified.


Assuntos
Neoplasias Renais , Tumores Neuroendócrinos , Humanos , Rim/diagnóstico por imagem , Rim/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Masculino , Nefrectomia , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/cirurgia
16.
Expert Rev Pharmacoecon Outcomes Res ; 21(2): 299-305, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32564699

RESUMO

BACKGROUND: We aimed to analyze the impact of two different types of surgical instrumentation (conventional manual instrumentation (CI) and patient-specific instrumentation (PSI)) on length of stay (LOS) and objectify differences in cost. We hypothesized that there are no differences in the LOS and cost due to the instrumentation system used. RESEARCH DESIGN AND METHODS: LOS was registered using inpatient admission data provided by the Institutional Management Control Department. We recorded the costs associated with each procedure that could be influenced by the use of one system or another during the in-hospital stay. We conducted a prospectively single-center cohort study of 305 TKAs. Surgery was performed with conventional CI in 122 cases and with PSI in 183 cases. RESULTS: The mean LOS for the CI group was 4.29 days (SD 1.65) and 4.22 days (SD 1.26), for the PSI group. No significant difference among both instrumentation systems was obtained. When comparing global costs, the mean cost was slightly higher (without a significant difference) for the PSI cases (€3110.24 vs. €2852.7 for the CI cases). CONCLUSIONS: LOS and overall cost, in hospitals with a low annual TKA surgery volume, are unrelated to conventional or patient-specific instrumentation.


Assuntos
Artroplastia do Joelho/instrumentação , Custos Hospitalares/estatística & dados numéricos , Hospitalização/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Idoso , Artroplastia do Joelho/economia , Estudos de Coortes , Feminino , Hospitalização/economia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
17.
J Clin Med ; 10(7)2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33916110

RESUMO

There have been remarkable advances in knee replacement surgery over the last few decades. One of the concerns continues to be the accuracy in achieving the desired alignment. Patient-specific instrumentation (PSI) was developed to increase component placement accuracy, but the available evidence is not conclusive. Our study aimed to determine a PSI system's three-dimensional accuracy on 3D virtual models obtained by post-operative computed tomography. We compared the angular placement values of 35 total knee arthroplasties (TKAs) operated within a year obtained with the planned ones, and we analyzed the possible relationships between alignment and patient-reported outcomes. The mean (SD) discrepancies measured by two experienced engineers to the planned values observed were 1.64° (1.3°) for the hip-knee-ankle angle, 1.45° (1.06°) for the supplementary angle of the femoral lateral distal angle, 1.44° (0.97°) for the proximal medial tibial angle, 2.28° (1.78°) for tibial slope, 0.64° (1.09°) for femoral sagittal flexion, and 1.42° (1.06°) for femoral rotation. Neither variables related to post-operative alignment nor the proportion of change between pre-and post-operative alignment influenced the patient-reported outcomes. The evaluated PSI system's three-dimensional alignment analysis showed a statistically significant difference between the angular values planned and those obtained. However, we did not find a relevant effect size, and this slight discrepancy did not impact the clinical outcome.

18.
J Orthop Surg (Hong Kong) ; 29(2): 23094990211010520, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33896261

RESUMO

PURPOSE: Several studies have been carried out, and there is no classification for proximal humeral fractures (PHF) exempted from variability in interpretation and with questioned reliability. In the present study, we investigated the 'absolute diagnostic reliability' of the most currently used classifications for PHFs on a single anterior-posterior X-ray shoulder image. METHODS: Six orthopaedic surgeons, with varying levels of experience in shoulder pathology, evaluated radiographs from 30 proximal humeral fractures, according to the 'absolute reliability' criteria. Each of the observers rated each fracture according to Neer, Müller/AO and Codman-Hertel's classification systems. RESULTS: The overall inter-observer agreement (κ) has been 0.297 (CI95% 0.280 to 0.314) for the Neer's classification system, 0.206 (CI95% 0.193 to 0.218) for the Müller/AO classification system, and 0.315 (CI95% 0.334 to 0.368) for the Codman-Hertel classification system. We found loss of agreement in Neer's classification as the study progressed, low agreement in the AO classification, and stable values in the different evaluations with the best degree of agreement for Codman-Hertel classification, with a moderate agreement in the second evaluation among the six evaluators. CONCLUSION: The Neer, AO, and Hertel-Codman classification systems for PHF with a single radiographic projection have a difficult interpretation for orthopaedic surgeons of varying levels of experience, and therefore substantial agreements are not obtained.


Assuntos
Fraturas do Ombro/classificação , Fraturas do Ombro/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cirurgiões Ortopédicos , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
J Knee Surg ; 33(11): 1128-1131, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31269525

RESUMO

The ability to predict accurate sizing of the implant components for total knee arthroplasty surgery can have several benefits in the operating room, in terms of simplifying the workflow and reducing the number of required instrument trays. Planning on a three-dimensional (3D) virtual model can be used to predict size. The aim of this study was to quantify the accuracy of the surgeon-validated plan prediction on a computed tomography (CT)-based system. The clinical records of 336 cases (267 patients), operated using a CT-based patient-specific instrumentation, have been reviewed for the size of implanted components. Preoperative default planning (according to the preferences of the surgeon) and approved planning have been compared with the size of implanted components for both the femur and tibia. The prosthesis size, preplanned by the manufacturers, was modified by the surgeon during the validation process in 0.9% of cases for the femoral component and in 2.7% of cases for the tibial component. The prosthesis size, preplanned by the surgeon after the validation process, was used in 95.8% for the femur and 92.6% for the tibia. Concordance on the size of the surgeon-validated plan and the finally implanted size was perfect for both, the femoral (κ = 0.951; 95% confidence interval [CI]: 0.92-0.98) and the tibial component (κ = 0.902; 95% CI: 0.86-0.94). The most frequent change of size (51%) was an increase by one size of the planned tibial component. Planning of knee arthroplasty surgery on a 3D virtual, CT-based model is useful to surgeons to help predict the size of the implants to be used in surgery. The system we have used can accurately predict the component size for both the femur and tibia. This study reflects a study of level III evidence.


Assuntos
Artroplastia do Joelho/métodos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Ajuste de Prótese , Cirurgia Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Estudos Retrospectivos , Software
20.
Knee ; 27(2): 543-551, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31954608

RESUMO

BACKGROUND: The aim of the study was to determine any discrepancies among preoperative full-leg standing radiographs (LLR) and supine non-weight-bearing computed tomography (CT)-scan-based three-dimensional (3D) models in the assessment of the lower limb alignment prior to total knee arthroplasty (TKA) and answer the question of whether the LLR study can be obviated in preoperative planning when TKA is performed with patient-specific instrumentation (PSI). METHODS: LLR and CT-scan-based 3D models of 227 knees (183 patients) were measured. LLR data was then compared to 3D alignment data used to design the PSI for TKA surgery. RESULTS: Alignment on LLR ranged from 153 to 194° versus 161.5 to 190.5° with CT-scan-based 3D models. The mean (standard deviation, SD) difference among techniques was 1.9° (1.15°) with a statistically significant difference (P = 2e-16, namely P < .0001). Supine CT-scan-based 3D models underestimated the deformity in 167 cases (73.6%), exactly matched the value of LLR in 24 cases (10.6%) and overestimated the deformity in 36 cases (15.8%). CONCLUSION: CT-scan-based models underestimate the degree of deformity at the knee joint. Despite the accurate information provided by the CT-scan and the 3D models (which is the basis for the planning of bone cuts), weight-bearing LLR should not be overlooked in the planning of TKA surgery to assess the extent of the coronal mediolateral instability.


Assuntos
Artroplastia do Joelho/métodos , Imageamento Tridimensional/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Radiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Suporte de Carga/fisiologia , Idoso , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/fisiopatologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA