Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Adv Mater ; 35(22): e2300228, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36862114

RESUMO

Pulsatile drug delivery systems have the potential to improve patient adherence and therapeutic efficacy by providing a sequence of doses in a single injection. Herein, a novel platform, termed Particles Uniformly Liquified and Sealed to Encapsulate Drugs (PULSED) is developed, which enables the high-throughput fabrication of microparticles exhibiting pulsatile release. In PULSED, biodegradable polymeric microstructures with an open cavity are formed using high-resolution 3D printing and soft lithography, filled with drug, and sealed using a contactless heating step in which the polymer flows over the orifice to form a complete shell around a drug-loaded core. Poly(lactic-co-glycolic acid) particles with this structure can rapidly release encapsulated material after delays of 10 ± 1, 15 ± 1, 17 ± 2, or 36 ± 1 days in vivo, depending on polymer molecular weight and end group. The system is even compatible with biologics, releasing over 90% of bevacizumab in its bioactive form after a two-week delay in vitro. The PULSED system is highly versatile, offering compatibility with crystalline and amorphous polymers, easily injectable particle sizes, and compatibility with several newly developed drug loading methods. Together, these results suggest that PULSED is a promising platform for creating long-acting drug formulations that improve patient outcomes due to its simplicity, low cost, and scalability.


Assuntos
Sistemas de Liberação de Medicamentos , Polímeros , Humanos , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Liberação Controlada de Fármacos , Polímeros/química , Composição de Medicamentos/métodos , Tamanho da Partícula
2.
J Biomed Mater Res A ; 109(12): 2438-2448, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34196100

RESUMO

Type 1 diabetic patients with severe hypoglycemia unawareness have benefitted from cellular therapies, such as pancreas or islet transplantation; however, donor shortage and the need for immunosuppression limits widespread clinical application. We previously developed an intravascular bioartificial pancreas (iBAP) using silicon nanopore membranes (SNM) for immunoprotection. To ensure ample nutrient delivery, the iBAP will need a cell scaffold with high hydraulic permeability to provide mechanical support and maintain islet viability and function. Here, we examine the feasibility of superporous agarose (SPA) as a potential cell scaffold in the iBAP. SPA exhibits 66-fold greater hydraulic permeability than the SNM along with a short (<10 µm) diffusion distance to the nearest islet. SPA also supports short-term functionality of both encapsulated human islets and stem-cell-derived enriched ß-clusters in a convection-based system, demonstrated by high viability (>95%) and biphasic insulin responses to dynamic glucose stimulus. These findings suggest that the SPA scaffold will not limit nutrient delivery in a convection-based bioartificial pancreas and merits continued investigation.


Assuntos
Células Secretoras de Insulina , Ilhotas Pancreáticas , Pâncreas Artificial , Sefarose/química , Transplante de Células-Tronco/métodos , Alicerces Teciduais , Adulto , Diabetes Mellitus Tipo 1/terapia , Glucose/farmacologia , Doença Enxerto-Hospedeiro/prevenção & controle , Humanos , Células Secretoras de Insulina/efeitos dos fármacos , Células Secretoras de Insulina/metabolismo , Ilhotas Pancreáticas/efeitos dos fármacos , Ilhotas Pancreáticas/metabolismo , Transplante das Ilhotas Pancreáticas , Membranas Artificiais , Nanoporos , Silício
3.
IEEE Trans Biomed Eng ; 64(7): 1654-1659, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28113196

RESUMO

Cryoelectrolysis is a new minimally invasive tissue ablation surgical technique that combines the processes of electrolysis and solid/liquid phase transformation (freezing). This study investigated this new technique by measuring the pH front propagation and the changes in resistance in a tissue simulant made of physiological saline gel with a pH dye as a function of the sample temperature in the high subzero range above the eutectic. Results demonstrated that effective electrolysis can occur in a high subzero freezing milieu and that the propagation of the pH front is only weakly dependent on temperature. These observations are consistent with a mechanism involving ionic movement through the concentrated saline solution channels between ice crystals at subfreezing temperatures above the eutectic. Moreover, results suggest that Joule heating in these microchannels may cause local microscopic melting, the observed weak dependence of pH front propagation on temperature, and the large changes in resistance with time. A final insight provided by the results is that the pH front propagation from the anode is more rapid than from the cathode, a feature indicative of the electro-osmotic flow from the cathode to the anode. The findings in this paper may be critical for designing future cryoelectrolytic ablation surgery protocols.


Assuntos
Líquidos Corporais/química , Criocirurgia/métodos , Eletroquímica/métodos , Eletrólise/métodos , Concentração de Íons de Hidrogênio , Cloreto de Sódio/química , Materiais Biomiméticos/química , Congelamento , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA