J Environ Sci (China) ; 146: 103-117, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38969439

RESUMO

The reliable application of field deployable fluorescent dissolved organic matter (fDOM) probes is hindered by several influencing factors which need to be compensated. This manuscript describes the corrections of temperature, pH, turbidity and inner filter effect on fluorescence signal of a commercial fDOM probe (fDOMs). For this, Australian waters with wide ranging qualities were selected, e.g. dissolved organic carbon (DOC) ranging from ∼1 to ∼30 mg/L, specific UV absorbance at 254 nm from ∼1 to ∼6 L/m/mg and turbidity from ∼1 to ∼ 350 FNU. Laboratory-based model calibration experiments (MCEs) were performed. A model template was developed and used for the development of the correction models. For each factor, data generated through MCEs were used to determine model coefficient (α) values by fitting the generated model to the experimental data. Four discrete factor models were generated by determination of a factor-specific α value. The α values derived for each water of the MCEs subset were consistent for each factor model. This indicated generic nature of the four α values across wide-ranging water qualities. High correlation between fDOMs and DOC were achieved after applying the four-factor compensation models to new data (r, 0.96, p < 0.05). Also, average biases (and %) between DOC predicted through fDOMs and actual DOC were decreased by applying the four-factor compensation model (from 3.54 (60.9%) to 1.28 (16.7%) mg/L DOC). These correction models were incorporated into a Microsoft EXCEL-based software termed EXOf-Correct for ready-to-use applications.


Assuntos
Monitoramento Ambiental , Água Doce , Monitoramento Ambiental/métodos , Fluorescência , Modelos Químicos , Corantes Fluorescentes/química , Modelos Teóricos , Poluentes Químicos da Água/análise
2.
Environ Sci Pollut Res Int ; 29(13): 19530-19539, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34718954

RESUMO

Stormwater runoff contains a myriad of pollutants, including faecal microbes, and can pose a threat to urban water supplies, impacting both economic development and public health. Therefore, it is a necessity to implement a real-time hazard detection system that can collect a substantial amount of data, assisting water authorities to develop preventive strategies to ensure the control of hazards entering drinking water sources. An on-line UV-Vis spectrophotometer was applied in the field to collect real-time continuous data for various water quality parameters (nitrate, DOC, turbidity and total suspended solids) during three storm events in Mannum, Adelaide, Australia. This study demonstrated that the trends for on-line and comparative laboratory-analysed samples were complimentary through the events. Nitrate and DOC showed a negative correlation with water level, while turbidity and total suspended solids indicated a positive correlation with water level during the high rainfall intensity. The correlations among nitrate, DOC, turbidity, total suspended solids and water level are the opposite during low rainfall intensity. Nitrate, one of the main pollutants in stormwater, was investigated and used as a surrogate parameter for microbial detection. However, the microbiological data (Escherichia coli) from captured storm events showed poor correlations to nitrate and other typical on-line parameters in this study. This is possibly explained by the nature of the stormwater catchment outside of rain events, where the sources of bacteria and nutrients may be physically separated until mixed during surface runoff as a result of rainfall. In addition, the poor correlations among the microbiological data and on-line parameters could be due to the different sources of bacteria and nutrients that were transported to the stormwater drain where sampling and measurement were conducted.


Assuntos
Movimentos da Água , Poluentes Químicos da Água , Monitoramento Ambiental/métodos , Chuva , Análise Espectral , Poluentes Químicos da Água/análise