Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Obes (Lond) ; 48(9): 1266-1273, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38824227

RESUMO

BACKGROUND/OBJECTIVE: Phthalates and phthalate replacements are used in multiple everyday products, making many of them bioavailable to children. Experimental studies suggest that phthalates and their replacements may be obesogenic, however, epidemiologic studies remain inconsistent. Therefore, our objective was to examine the association between phthalates, phthalate replacements and childhood adiposity/obesity markers in children. SUBJECTS/METHODS: A cross-sectional study was conducted in 630 racial/ethnically diverse children ages 4-8 years. Urinary oxidative metabolites of DINCH and DEHTP, three low molecular weight (LMW) phthalates, and eleven high molecular weight (HMW) phthalates were measured. Weight, height, waist circumference and % body fat were measured. Composite molar sum groups (nmol/ml) were natural log-transformed. Linear regression models adjusted for urine specific gravity, sex, age, race-ethnicity, birthweight, breastfeeding, reported activity level, mother's education and pre-pregnancy BMI. RESULTS: All children had LMW and HMW phthalate metabolites and 88% had DINCH levels above the limit of detection. One unit higher in the log of DINCH was associated with 0.106 units lower BMI z-score [ß = -0.106 (95% CI: -0.181, -0.031)], 0.119 units lower waist circumference z-score [ß = -0.119 (95% CI: -0.189, -0.050)], and 0.012 units lower percent body fat [ß = -0.012 (95% CI: -0.019, -0.005)]. LMW and HMW group values were not associated with adiposity/obesity. CONCLUSIONS: We report an inverse association between child urinary DINCH levels, a non-phthalate plasticizer that has replaced DEHP in several applications, and BMI z-score, waist circumference z-score and % body fat in children. Few prior studies of phthalates and their replacements in children have been conducted in diverse populations. Moreover, DINCH has not received a great deal of attention or regulation, but it is a common exposure. In summary, understanding the ubiquitous nature of these chemical exposures and ultimately their sources will contribute to our understanding of their relationship with obesity.


Assuntos
Adiposidade , Ácidos Ftálicos , Humanos , Ácidos Ftálicos/urina , Feminino , Masculino , Estudos Transversais , Criança , Pré-Escolar , Obesidade Infantil/epidemiologia , Obesidade Infantil/urina , Índice de Massa Corporal , Exposição Ambiental/efeitos adversos , Exposição Ambiental/estatística & dados numéricos , Circunferência da Cintura , Poluentes Ambientais/urina
2.
Am J Obstet Gynecol ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838912

RESUMO

BACKGROUND: A major goal of contemporary obstetrical practice is to optimize fetal growth and development throughout pregnancy. To date, fetal growth during prenatal care is assessed by performing ultrasonographic measurement of 2-dimensional fetal biometry to calculate an estimated fetal weight. Our group previously established 2-dimensional fetal growth standards using sonographic data from a large cohort with multiple sonograms. A separate objective of that investigation involved the collection of fetal volumes from the same cohort. OBJECTIVE: The Fetal 3D Study was designed to establish standards for fetal soft tissue and organ volume measurements by 3-dimensional ultrasonography and compare growth trajectories with conventional 2-dimensional measures where applicable. STUDY DESIGN: The National Institute of Child Health and Human Development Fetal 3D Study included research-quality images of singletons collected in a prospective, racially and ethnically diverse, low-risk cohort of pregnant individuals at 12 U.S. sites, with up to 5 scans per fetus (N=1730 fetuses). Abdominal subcutaneous tissue thickness was measured from 2-dimensional images and fetal limb soft tissue parameters extracted from 3-dimensional multiplanar views. Cerebellar, lung, liver, and kidney volumes were measured using virtual organ computer aided analysis. Fractional arm and thigh total volumes, and fractional lean limb volumes were measured, with fractional limb fat volume calculated by subtracting lean from total. For each measure, weighted curves (fifth, 50th, 95th percentiles) were derived from 15 to 41 weeks' using linear mixed models for repeated measures with cubic splines. RESULTS: Subcutaneous thickness of the abdomen, arm, and thigh increased linearly, with slight acceleration around 27 to 29 weeks. Fractional volumes of the arm, thigh, and lean limb volumes increased along a quadratic curvature, with acceleration around 29 to 30 weeks. In contrast, growth patterns for 2-dimensional humerus and femur lengths demonstrated a logarithmic shape, with fastest growth in the second trimester. The mid-arm area curve was similar in shape to fractional arm volume, with an acceleration around 30 weeks, whereas the curve for the lean arm area was more gradual. The abdominal area curve was similar to the mid-arm area curve with an acceleration around 29 weeks. The mid-thigh and lean area curves differed from the arm areas by exhibiting a deceleration at 39 weeks. The growth curves for the mid-arm and thigh circumferences were more linear. Cerebellar 2-dimensional diameter increased linearly, whereas cerebellar 3-dimensional volume growth gradually accelerated until 32 weeks followed by a more linear growth. Lung, kidney, and liver volumes all demonstrated gradual early growth followed by a linear acceleration beginning at 25 weeks for lungs, 26 to 27 weeks for kidneys, and 29 weeks for liver. CONCLUSION: Growth patterns and timing of maximal growth for 3-dimensional lean and fat measures, limb and organ volumes differed from patterns revealed by traditional 2-dimensional growth measures, suggesting these parameters reflect unique facets of fetal growth. Growth in these three-dimensional measures may be altered by genetic, nutritional, metabolic, or environmental influences and pregnancy complications, in ways not identifiable using corresponding 2-dimensional measures. Further investigation into the relationships of these 3-dimensional standards to abnormal fetal growth, adverse perinatal outcomes, and health status in postnatal life is warranted.

3.
Am J Perinatol ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39074807

RESUMO

OBJECTIVE: This study aimed to examine associations of fetal biometric and amniotic fluid measures with intrapartum primary cesarean delivery (PCD) and develop prediction models for PCD based on ultrasound parameters and maternal factors. STUDY DESIGN: Secondary analysis of the National Institute of the Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) Fetal Growth Studies-singleton cohort (2009-2013) including patients with uncomplicated pregnancies and intent to deliver vaginally at ≥370/7 weeks. The estimated fetal weight, individual biometric parameters, fetal asymmetry measurements, and amniotic fluid single deepest vertical pocket assessed at the final scan (mean 37.5 ± 1.9 weeks) were categorized as <10th, 10th to 90th (reference), and >90th percentiles. Logistic regression analyses examined the association between the ultrasound measures and PCD. Fetal and maternal SuperLearner prediction algorithms were constructed for the full and nulliparous cohorts. RESULTS: Of the 1,668 patients analyzed, 249 (14.9%) had PCD. The fetal head circumference, occipital-frontal diameter, and transverse abdominal diameter >90th percentile (adjusted odds ratio [aOR] = 2.50, 95% confidence interval [95% CI]: 1.39, 4.51; aOR = 1.86, 95% CI: 1.02, 3.40; and aOR = 2.13, 95% CI: 1.16, 3.89, respectively) were associated with PCD. The fetal model demonstrated poor ability to predict PCD in the full cohort and in nulliparous patients (area under the receiver-operating characteristic curve [AUC] = 0.56, 95% CI: 0.52, 0.61; and AUC = 0.54, 95% CI: 0.49, 0.60, respectively). Conversely, the maternal model had better predictive capability overall (AUC = 0.79, 95% CI: 0.75, 0.82) and in the nulliparous subgroup (AUC = 0.72, 95% CI: 0.67, 0.77). Models combining maternal/fetal factors performed similarly to the maternal model (AUC = 0.78, 95% CI: 0.75, 0.82 in full cohort, and AUC = 0.71, 95% CI: 0.66, 0.76 in nulliparas). CONCLUSION: Although a few fetal biometric parameters were associated with PCD, the fetal prediction model had low performance. In contrast, the maternal model had a fair-to-good ability to predict PCD. KEY POINTS: · Fetal HC >90th percentile was associated with cesarean delivery.. · Fetal parameters did not effectively predict PCD.. · Maternal factors were more predictive of PCD.. · Maternal/fetal and maternal models performed similarly.. · Prediction models had lower performance in nulliparas..

4.
BMC Pregnancy Childbirth ; 23(1): 154, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36890487

RESUMO

BACKGROUND: Idiopathic intracranial hypertension can lead to dural defects and spontaneous leakage of cerebrospinal fluid (CSF) from the skull base. Skull base CSF leaks are rarely reported in pregnancy but pose unique challenges for obstetricians and anesthesiologists. CASE PRESENTATION: A 31-year-old G4P1021 at 14 weeks developed debilitating headaches and CSF rhinorrhea. Brain imaging revealed a bony defect of the sphenoid sinus with a meningoencephalocele and a partially empty sella, consistent with CSF leakage from a skull base defect. The patient was neurologically stable without signs of meningitis; thus, management was focused on symptomatic alleviation. A planned cesarean section was performed at 38 weeks under spinal anesthesia. The patient had spontaneous marked improvement of her symptoms postpartum. CONCLUSION: Pregnancy may exacerbate skull base CSF leaks, requiring careful management with a multidisciplinary team. Neuraxial anesthesia can safely be performed in pregnant individuals with spontaneous skull base CSF leakage, but further studies are needed to determine the safest mode of delivery in these patients.


Assuntos
Rinorreia de Líquido Cefalorraquidiano , Hipertensão Intracraniana , Gravidez , Humanos , Feminino , Adulto , Cesárea , Vazamento de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/cirurgia , Rinorreia de Líquido Cefalorraquidiano/diagnóstico , Base do Crânio/diagnóstico por imagem
5.
Am J Obstet Gynecol ; 221(6): 635.e1-635.e16, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31226296

RESUMO

BACKGROUND: Fetal growth patterns in pregnancy-associated hypertensive disorders is poorly understood because prospective longitudinal data are lacking. OBJECTIVE: The objective of the study was to compare longitudinal fetal growth trajectories between normotensive women and those with pregnancy-associated hypertensive disorders. STUDY DESIGN: This is a study based on data from a prospective longitudinal cohort study of fetal growth performed at 12 US sites (2009-2013). Project gestational age was confirmed by ultrasound between 8 weeks 0 days and 13 weels 6 days, and up to 6 ultrasounds were performed across gestation. Hypertensive disorders were diagnosed based on 2002 American College of Obstetricians and Gynecologists guidelines and grouped hierarchically as severe preeclampsia (including eclampsia or HELLP [hemolysis, elevated liver enzymes, and low platelet count] syndrome), mild preeclampsia, severe gestational hypertension, mild gestational hypertension, or unspecified hypertension. Women without any hypertensive disorder constituted the normotensive group. Growth curves for estimated fetal weight and individual biometric parameters including biparietal diameter, head circumference, abdominal circumference, and femur and humerus length were calculated for each group using linear mixed models with cubic splines. Global and weekly pairwise comparisons were performed between women with a hypertensive disorder compared with normotensive women to analyze differences while adjusting for confounding variables. Delivery gestational age and birthweights were compared among groups. RESULTS: Of 2462 women analyzed, 2296 (93.3%) were normotensive, 63 (2.6%) had mild gestational hypertension, 54 (2.2%) mild preeclampsia, 32 (1.3%) severe preeclampsia, and 17 (0.7%) unspecified hypertension. Compared with normotensive women, those with severe preeclampsia had estimated fetal weights that were reduced between 22 and 38 weeks (all weekly pairwise values of P < .008). Women with severe preeclampsia compared with those without hypertension also had significantly smaller fetal abdominal circumference between 23-31 and 33-37 weeks' gestation (weekly pairwise values of P < .04). Scattered weekly growth differences were noted on other biometric parameters between these 2 groups. The consistent differences in estimated fetal weight and abdominal circumference were not observed between women with other hypertensive disorders and those who were normotensive. Women with severe preeclampsia delivered significantly earlier (mean gestational age 35.9 ± 3.2 weeks) than the other groups (global P < .0001). Birthweights in the severe preeclampsia group were also significantly lower (mean -949.5 g [95% confidence interval, -1117.7 to -781.2 g]; P < .0001) than in the normotensive group. CONCLUSION: Among women with pregnancy-associated hypertensive disorders, only those destined to develop severe preeclampsia demonstrated a significant and consistent difference in fetal growth (ie, smaller estimated fetal weight and abdominal circumference) when compared with normotensive women.


Assuntos
Desenvolvimento Fetal/fisiologia , Hipertensão Induzida pela Gravidez/fisiopatologia , Adulto , Peso ao Nascer , Feminino , Humanos , Recém-Nascido , Pré-Eclâmpsia/fisiopatologia , Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal
6.
Am J Perinatol ; 36(10): 997-1001, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30822801

RESUMO

OBJECTIVE: To evaluate the prevalence of cesarean delivery in women with hypertensive disorders of pregnancy (HDP), and explore whether maternal, sociodemographic, or obstetric comorbidities contribute to cesarean delivery rates. STUDY DESIGN: This is a retrospective cohort study of nulliparous, term, singleton, vertex women using the 2013 U.S. National Vital Statistics Report. We compared prevalence of risk factors for cesarean delivery between women with and without HDP, and then calculated probabilities of cesarean delivery after controlling for these risk factors. RESULTS: In this cohort of 1,439,977 women, the unadjusted probability of cesarean delivery in women with HDP was 39.5 versus 26.8% in those without the diagnosis (p < 0.01). Hypertensive women had more risk factors for cesarean delivery, most notably morbid obesity (9.0 vs. 3.1%, p < 0.01), diabetes (9.9 vs. 4.4%, p < 0.01), and induction of labor (59.2 vs. 26.9%, p < 0.01). Despite this, after controlling for these risk factors, hypertensive women remained significantly more likely to undergo cesarean delivery (35.1 vs. 26.4%, p < 0.01). CONCLUSION: Even after controlling for multiple comorbidities, hypertension remained a significant risk factor for cesarean delivery in nulliparous women at term. Hypertensive women may therefore represent an important target population in efforts aimed at reduction of cesarean rates.


Assuntos
Cesárea/estatística & dados numéricos , Hipertensão Induzida pela Gravidez , Índice de Massa Corporal , Feminino , Humanos , Paridade , Gravidez , Probabilidade , Estudos Retrospectivos , Fatores de Risco , Fatores Socioeconômicos
7.
Am J Obstet Gynecol ; 219(3): 285.e1-285.e36, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29803819

RESUMO

BACKGROUND: Accurately identifying pregnancies with accelerated or diminished fetal growth is challenging and generally based on cross-sectional percentile estimates of fetal weight. Longitudinal growth velocity might improve identification of abnormally grown fetuses. OBJECTIVE: We sought to complement fetal size standards with fetal growth velocity, develop a model to compute fetal growth velocity percentiles for any given set of gestational week intervals, and determine association between fetal growth velocity and birthweight. STUDY DESIGN: This was a prospective cohort study with data collected at 12 US sites (2009 through 2013) from 1733 nonobese, low-risk pregnancies included in the singleton standard. Following a standardized sonogram at 10w0d-13w6d, each woman was randomized to 1 of 4 follow-up visit schedules with 5 additional study sonograms (targeted ranges: 16-22, 24-29, 30-33, 34-37, and 38-41 weeks). Study visits could occur ± 1 week from the targeted GA. Ultrasound biometric measurements included biparietal diameter, head circumference, abdominal circumference, and femur length, and estimated fetal weight was calculated. We used linear mixed models with cubic splines for the fixed effects and random effects to flexibly model ultrasound trajectories. We computed velocity percentiles in 2 ways: (1) difference between 2 consecutive weekly measurements (ie, weekly velocity), and (2) difference between any 2 ultrasounds at a clinically reasonable difference between 2 gestational ages (ie, velocity calculator). We compared correlation between fetal growth velocity percentiles and estimated fetal weight percentiles at 4-week intervals, with 32 (±1) weeks' gestation for illustration. Growth velocity was computed as estimated fetal growth rate (g/wk) between ultrasound at that gestational age and from prior visit [ie, for 28-32 weeks' gestational age: velocity = (estimated fetal weight 32-28)/(gestational age 32-28)]. We examined differences in birthweight by whether or not estimated fetal weight and estimated fetal weight velocity were <5th or ≥5th percentiles using χ2. RESULTS: Fetal growth velocity was nonmonotonic, with acceleration early in pregnancy, peaking at 13, 14, 15, and 16 weeks for biparietal diameter, head circumference, femur length, and abdominal circumference, respectively. Biparietal diameter, head circumference, and abdominal circumference had a second acceleration at 19-22, 19-21, and 27-31 weeks, respectively. Estimated fetal weight velocity peaked around 35 weeks. Fetal growth velocity varied slightly by race/ethnicity although comparisons reflected differences for parameters at various gestational ages. Estimated fetal weight velocity percentiles were not highly correlated with fetal size percentiles (Pearson r = 0.40-0.41, P < .001), suggesting that these measurements reflect different aspects of fetal growth and velocity may add additional information to a single measure of estimated fetal weight. At 32 (SD ± 1) weeks, if both estimated fetal weight velocity and size were <5th percentile, mean birthweight was 2550 g; however, even when size remained <5th percentile but velocity was ≥5th percentile, birthweight increased to 2867 g, reflecting the important contribution of higher growth velocities. For estimated fetal weight ≥5th percentile, but growth velocity <5th, birthweight was smaller (3208 vs 3357 g, respectively, P < .001). CONCLUSION: We provide fetal growth velocity data to complement our previous work on fetal growth size standards, and have developed a calculator to compute fetal growth velocity. Preliminary findings suggest that growth velocity adds additional information over knowing fetal size alone.


Assuntos
Desenvolvimento Fetal , Peso Fetal , Gráficos de Crescimento , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , National Institute of Child Health and Human Development (U.S.) , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Fatores de Tempo , Ultrassonografia Pré-Natal , Estados Unidos
8.
Clin Obstet Gynecol ; 61(4): 795-807, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30289770

RESUMO

The role of Interventional radiologic procedures for the management of suspected placenta accreta spectrum (PAS) has evolved considerably over last 3 decades. In this article, the authors describe the various techniques of vascular occlusion for the management of PAS and provide a brief review of the literature examining the pros and cons in the use of these devices.


Assuntos
Oclusão com Balão/métodos , Cesárea/métodos , Placenta Acreta/terapia , Embolização da Artéria Uterina/métodos , Aorta Abdominal , Feminino , Humanos , Artéria Ilíaca , Gravidez , Radiologia Intervencionista , Fatores de Tempo
9.
Am J Perinatol ; 35(1): 84-89, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28838010

RESUMO

OBJECTIVE: The aim was to determine the fetal umbilical blood gas effects of supplemental maternal oxygenation compared with room air (RA) during term planned cesarean delivery. METHODS: This is a prospective randomized controlled study of singleton planned cesarean deliveries randomized to receive supplemental oxygen (O2) at 10 L per minute (L/min) via facemask or RA. Umbilical cord gases were collected. The primary outcome was umbilical arterial pH level. Secondary outcomes included umbilical cord values and maternal and neonatal outcomes. Data were expressed as median ± interquartile range (IQR). RESULTS: Seventy subjects in total were enrolled, with 65 subjects available for analysis. The median umbilical arterial pO2 was significantly increased in the supplemental O2 group (18 [13.5-20.5] mm Hg) versus RA group (16 [12-18] mm Hg), p = 0.04). The median umbilical venous pO2 was significantly increased in the supplemental O2 group (32 [26.5-36.0] mm Hg) versus RA group (28.5 [22-34.3] mm Hg), p = 0.04). There were no significant differences with other umbilical blood gas values and composite maternal or neonatal complications. CONCLUSION: Subjects with term singleton gestations receiving O2 at 10 L/min during cesarean delivery compared with RA demonstrated no significant change in umbilical cord pH values. There was a significant increase in umbilical cord arterial and venous O2 levels in those receiving O2.


Assuntos
Anestesia Obstétrica , Cesárea , Oxigenoterapia , Oxigênio/sangue , Cordão Umbilical/química , Adulto , Índice de Apgar , Gasometria , California , Procedimentos Cirúrgicos Eletivos , Feminino , Feto/fisiologia , Humanos , Concentração de Íons de Hidrogênio , Troca Materno-Fetal , Gravidez , Estudos Prospectivos , Nascimento a Termo
10.
Am J Obstet Gynecol ; 217(5): 594.e1-594.e10, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28712949

RESUMO

BACKGROUND: Trophoblastic invasion of the uterine spiral arteries substantially increases compliance to accommodate increased blood flow to the placenta. Failure of this process impedes uterine artery blood flow, and this may be detected by uterine artery Doppler flow studies. However, the clinical utility of uterine artery Doppler flow studies in the prediction of adverse pregnancy outcomes in a general population remains largely unknown. OBJECTIVE: We sought to determine the utility of early second-trimester uterine artery Doppler studies as a predictor of small-for-gestational-age neonates. STUDY DESIGN: Nulliparous women with a viable singleton pregnancy were recruited during their first trimester into an observational prospective cohort study at 8 institutions across the United States. Participants were seen at 3 study visits during pregnancy and again at delivery. Three indices of uterine artery Doppler flow (resistance index, pulsatility index, and diastolic notching) were measured in the right and left uterine arteries between 16 weeks 0 days' and 22 weeks 6 days' gestation. Test characteristics for varying thresholds in the prediction of small for gestational age (defined as birthweight <5th percentile for gestational age [Alexander growth curve]) were evaluated. RESULTS: Uterine artery Doppler indices, birthweight, and gestational age at birth were available for 8024 women. Birthweight <5th percentile for gestational age occurred in 358 (4.5%) births. Typical thresholds for the uterine artery Doppler indices were all associated with birthweight <5th percentile for gestational age (P < .0001 for each), but the positive predictive values for these cutoffs were all <15% and areas under receiver operating characteristic curves ranged from 0.50-0.60. Across the continuous scales for these measures, the areas under receiver operating characteristic curves ranged from 0.56-0.62. Incorporating maternal age, early pregnancy body mass index, race/ethnicity, smoking status prior to pregnancy, chronic hypertension, and pregestational diabetes in the prediction model resulted in only modest improvements in the areas under receiver operating characteristic curves ranging from 0.63-0.66. CONCLUSION: In this large prospective cohort, early second-trimester uterine artery Doppler studies were not a clinically useful test for predicting small-for-gestational-age babies.


Assuntos
Peso ao Nascer , Fluxo Pulsátil , Artéria Uterina/diagnóstico por imagem , Resistência Vascular , Adolescente , Adulto , Estudos de Coortes , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Paridade , Gravidez , Resultado da Gravidez , Segundo Trimestre da Gravidez , Estudos Prospectivos , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Adulto Jovem
13.
Am J Obstet Gynecol ; 212(4): 459-60, 459.e1, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25659470

RESUMO

We challenge a provocative article entitled "Oxygen for intrauterine resuscitation: of unproved benefit and potentially harmful" by Hamel et al in the August issue of the Journal. The authors contend there is no good evidence that oxygen administration to the mother of a fetus with a concerning fetal heart rate pattern prevents acidosis and that in theory such oxygen administration may actually or potentially do harm to the fetus. It is clear that oxygen is administered quite often to women in labor, especially to those with category II fetal heart rate patterns and, because more than 80% of women in labor have these patterns and the majority of these patterns are unlikely to be associated with significant fetal hypoxia, that such oxygen administration is greatly overused. We describe in this article evidence that oxygen given to the mother actually does improve fetal oxygenation, especially in hypoxemic fetuses, and make arguments that there really is no substantial evidence that, except in theory, maternal oxygen administration causes any harm to the fetus.


Assuntos
Complicações do Trabalho de Parto , Oxigenoterapia/efeitos adversos , Feminino , Humanos , Gravidez
14.
Am J Obstet Gynecol ; 213(4): 449.e1-449.e41, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26410205

RESUMO

OBJECTIVE: Fetal growth is associated with long-term health yet no appropriate standards exist for the early identification of undergrown or overgrown fetuses. We sought to develop contemporary fetal growth standards for 4 self-identified US racial/ethnic groups. STUDY DESIGN: We recruited for prospective follow-up 2334 healthy women with low-risk, singleton pregnancies from 12 community and perinatal centers from July 2009 through January 2013. The cohort comprised: 614 (26%) non-Hispanic whites, 611 (26%) non-Hispanic blacks, 649 (28%) Hispanics, and 460 (20%) Asians. Women were screened at 8w0d to 13w6d for maternal health status associated with presumably normal fetal growth (aged 18-40 years; body mass index 19.0-29.9 kg/m(2); healthy lifestyles and living conditions; low-risk medical and obstetrical history); 92% of recruited women completed the protocol. Women were randomized among 4 ultrasonography schedules for longitudinal fetal measurement using the Voluson E8 (GE Healthcare, Milwaukee, WI). In-person interviews and anthropometric assessments were conducted at each visit; medical records were abstracted. The fetuses of 1737 (74%) women continued to be low risk (uncomplicated pregnancy, absent anomalies) at birth, and their measurements were included in the standards. Racial/ethnic-specific fetal growth curves were estimated using linear mixed models with cubic splines. Estimated fetal weight (EFW) and biometric parameter percentiles (5th, 50th, 95th) were determined for each gestational week and comparisons made by race/ethnicity, with and without adjustment for maternal and sociodemographic factors. RESULTS: EFW differed significantly by race/ethnicity >20 weeks. Specifically at 39 weeks, the 5th, 50th, and 95th percentiles were 2790, 3505, and 4402 g for white; 2633, 3336, and 4226 g for Hispanic; 2621, 3270, and 4078 g for Asian; and 2622, 3260, and 4053 g for black women (adjusted global P < .001). For individual parameters, racial/ethnic differences by order of detection were: humerus and femur lengths (10 weeks), abdominal circumference (16 weeks), head circumference (21 weeks), and biparietal diameter (27 weeks). The study-derived standard based solely on the white group erroneously classifies as much as 15% of non-white fetuses as growth restricted (EFW <5th percentile). CONCLUSION: Significant differences in fetal growth were found among the 4 groups. Racial/ethnic-specific standards improve the precision in evaluating fetal growth.


Assuntos
Asiático , Negro ou Afro-Americano , Desenvolvimento Fetal/fisiologia , Hispânico ou Latino , Ultrassonografia Pré-Natal , População Branca , Adolescente , Adulto , Antropometria , Cefalometria , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , National Institute of Child Health and Human Development (U.S.) , Gravidez , Estudos Prospectivos , Valores de Referência , Estados Unidos , Adulto Jovem
15.
Am J Obstet Gynecol ; 210(3): 204-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24113255

RESUMO

The Perinatal Quality Foundation has created an examination containing both knowledge-based and judgment questions relating to the interpretation of electronic fetal heart rate monitoring for credentialing all medical and nursing personnel working on a labor and delivery floor. A description of the examination and the rationale for its use throughout the United States is presented.


Assuntos
Cardiotocografia , Credenciamento , Obstetrícia/educação , Feminino , Humanos , Gravidez , Estados Unidos
16.
Am J Obstet Gynecol ; 209(2): 89-97, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23628263

RESUMO

There is currently no standard national approach to the management of category II fetal heart rate (FHR) patterns, yet such patterns occur in the majority of fetuses in labor. Under such circumstances, it would be difficult to demonstrate the clinical efficacy of FHR monitoring even if this technique had immense intrinsic value, since there has never been a standard hypothesis to test dealing with interpretation and management of these abnormal patterns. We present an algorithm for the management of category II FHR patterns that reflects a synthesis of available evidence and current scientific thought. Use of this algorithm represents one way for the clinician to comply with the standard of care, and may enhance our overall ability to define the benefits of intrapartum FHR monitoring.


Assuntos
Monitorização Fetal , Frequência Cardíaca Fetal , Algoritmos , Feminino , Humanos , Concentração de Íons de Hidrogênio , Recém-Nascido , Trabalho de Parto , Gravidez
17.
Am J Obstet Gynecol ; 206(2): 104-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22000896

RESUMO

One standard by which obstetrical practice is measured is the ability to achieve a time line of ≤ 30 minutes from decision for surgery to time of surgical incision for women in labor for whom a cesarean delivery is indicated due to fetal intolerance to labor. We reviewed our institution's performance regarding this standard and identified an initial rate of 25% of cases actually meeting this standard. Using a program of continuous quality improvement, various systematic and individual barriers were identified and overcome resulting in a significant change in performance. This is a report of the various processes and identified areas of challenge encountered to improve on the ability to achieve this important standard of care.


Assuntos
Cesárea/normas , Tomada de Decisões , Obstetrícia/normas , Feminino , Humanos , Gravidez , Fatores de Tempo
18.
Ann Pharmacother ; 46(2): 297-300, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22298603

RESUMO

Based on a survey of the American College of Clinical Pharmacy Women's Health Practice and Research Network and our own experience, the pharmacy profession has limited involvement in obstetric pharmacotherapy. We believe that such involvement in pregnancies with complicated conditions can result in significant improvement of pregnancy outcomes. Moreover, we believe this involvement would be welcomed by the physicians caring for these patients. This commentary documents current obstetrical pharmacy practices and proposes changes for the profession of pharmacy to consider.


Assuntos
Tratamento Farmacológico , Serviços de Saúde Materna , Farmacêuticos , Gravidez , Papel Profissional , Feminino , Humanos , Cuidado Pré-Natal , Relações Profissional-Paciente , Estados Unidos
19.
J Matern Fetal Neonatal Med ; 35(25): 7778-7786, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34112053

RESUMO

OBJECTIVE: To assess differences in the perioperative complication rate between patients with placenta accreta spectrum (PAS) with and without complicating factors. METHODS: This retrospective cohort study included subjects who underwent cesarean hysterectomy with histology-proven PAS between 23 0/7 and 42 0/7 weeks gestational age (GA) from 1 July 2008 to 11 April 2017. Perioperative outcomes were compared between those with uncomplicated PAS and "complicated PAS," defined as PAS subjects who experienced ≥2 bleeding episodes, preterm premature rupture of membranes (PPROM), or premature contractions requiring tocolysis. RESULTS: Overall, 26 complicated PAS and 27 uncomplicated PAS cases were compared; no difference in the rate of perioperative complications was identified. An increased proportion of complicated PAS cases required blood product transfusion before delivery: 2 (40%), 3 (27.3%), and 2 patients (20%) for those with PPROM, preterm contractions, and ≥2 bleeding episodes respectively, compared to patients with uncomplicated PAS, having no transfusions (p = .001). Time of delivery was earlier for patients with complicated compared to uncomplicated PAS (median GA 30.9 [Q1 = 27.9; Q3 = 31.9] and 34.9 [Q1 = 32.1; Q3 = 35.7], p < .001). Median birthweights were lower (p < .0144) and maternal length of stay longer (p < .0012) for complicated PAS. CONCLUSION: Patients with complicated PAS were not at higher risk for perioperative complications but were associated with earlier delivery, required more antenatal blood transfusions, and had a longer LOS.


Assuntos
Ruptura Prematura de Membranas Fetais , Placenta Acreta , Recém-Nascido , Humanos , Feminino , Gravidez , Placenta Acreta/cirurgia , Estudos Retrospectivos , Ruptura Prematura de Membranas Fetais/cirurgia , Histerectomia/efeitos adversos , Estudos de Coortes
20.
Child Adolesc Obes ; 5(1): 3-15, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35128342

RESUMO

INTRODUCTION: A few studies have identified childhood animal exposure as associated with adiposity, but results are inconsistent and differ in timing. METHODS: We conducted an observational cohort study of children ages 4-8 in the Environmental Influences on Child Health Outcomes [ECHO] study. The main exposure was having a dog in the home and/or regular contact with farm animals during the first year of life. Outcomes of interest were child BMI percentile (adjusted for gender and age) categorized as normal/underweight (<85th percentile), overweight (85th to <95th), and obese (≥95th), and percent fat mass (continuous). Associations were analyzed using multinomial logistic regression and multivariable linear regression, respectively, with and without multiple imputation. RESULTS: First year animal exposure occurred in 245 of 770 (31.8%) children. Children with early animal exposure had 0.53 (95% CI: 0.28, 0.997) times the odds of being in the obese BMI category compared to those exposed to animals after controlling for covariates: maternal pre-pregnancy BMI, race/ethnicity, reported child activity level, receiving food assistance, age child began daycare (<1 year vs 1+), exclusively breastfed x6 months, and NICU admission (n=721). Children with early animal exposure had, on average, 1.5% (95% CI: -3.0, -0.1) less fat mass than exposed children after adjustment for maternal BMI, race/ethnicity, activity, food assistance, breastfeeding, and maternal education (n=548). Multiple imputation did not alter either result. CONCLUSION: These results provide evidence that exposure to dogs or farm animals in the first year of life is associated with lower odds of obesity and lower percent fat mass in childhood.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA