Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Rev Aging Phys Act ; 21(1): 6, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459483

RESUMO

BACKGROUND: Physical activity (PA) behaviours and comorbid diseases are associated with muscle strength. However, the association between dynapenia and detailed PA behaviours, including participation in aerobic and resistance exercises and sedentary behaviour (SB), in relation to comorbid diseases has not yet been investigated. Using nationwide data, this study aimed to evaluate the independent association of dynapenia with detailed PA behaviour (participation in aerobic and resistance exercises and SB), and assess the differential associations of detailed PA behaviour with dynapenia according to comorbid diseases with prevalent sarcopenia. METHODS: A total of 7,558 community-dwelling older adults aged ≥ 65 years who were included in the Korea National Health and Nutrition Examination Survey from 2014 to 2019 were included in the present study. Cross-sectional associations between PA behaviours (participation in aerobic exercise, participation in resistance exercise, and SB) and dynapenia were analysed using complex-sample multivariable-adjusted logistic regression models according to the type of comorbid disease (cardiovascular disease [CVD], diabetes mellitus [DM], and chronic lung disease [CLD]). RESULTS: Sufficient aerobic exercise, sufficient resistance exercise, and low sedentary time of < 420 min/day showed independent negative associations with dynapenia (odds ratio [OR], 0.71; 95% confidence interval [CI], 0.60-0.83; OR, 0.54; 95% CI, 0.42-0.69; and OR, 0.84; 95% CI, 0.72-0.97, respectively). Among the participants with CVD or CLD, the associations of sufficient resistance exercise (OR, 0.46; 95% CI, 0.26-0.82 and OR, 0.51; 95% CI, 0.35-0.75 for CVD and CLD, respectively) and low sedentary time (OR, 0.66; 95% CI, 0.45-0.98 and OR, 0.71; 95% CI, 0.55-0.93 for CVD and CLD, respectively) with dynapenia were significant, whereas the association of sufficient aerobic exercise with dynapenia was insignificant. Meanwhile, in participants with DM, sufficient aerobic exercise (OR, 0.70; 95% CI, 0.52-0.94) and sufficient resistance exercise (OR, 0.45; 95% CI, 0.29-0.70) were independently associated with dynapenia, whereas no association between SB and dynapenia was found. CONCLUSION: We observed an independent inverse association between PA behaviours and dynapenia. Disease-specific associations between each PA behaviour (sufficient aerobic exercise, sufficient resistance exercise, and low sedentary time) and dynapenia differed in the older adults. Therefore, these differences should be acknowledged during interventions for this population.

2.
Sci Rep ; 14(1): 2396, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514659

RESUMO

Although increased sedentary behavior is associated with poor health outcomes among breast cancer survivors, the factors associated with high sedentary time in community-dwelling breast cancer survivors are unknown. This study aimed to identify factors associated with sedentary behavior in Korean community-dwelling breast cancer survivors aged ≥ 50 years. We included 205 breast cancer survivors from the Korea National Health and Nutrition Examination Survey. Total daily sedentary time was evaluated using questions from the Korean version of the Global Physical Activity Questionnaire. We used complex-sample multivariable-adjusted logistic regression analyses to analyze the associations between sociodemographic factors, medical factors, and health-related quality of life and high sedentary time (≥ 420 min/day). Among the Korean community-dwelling breast cancer survivors, 48.2% had a high daily sedentary time. Insufficient aerobic exercise (OR 2.29; 95% CI 1.12-4.69), diabetes (OR 3.37; 95% CI 1.22-9.33), and unemployed status (OR 2.29; 95% CI 1.05-5.02) were independently associated with high sedentary time after the adjustment for multiple sociodemographic and medical confounders. Participants with a low sedentary time (< 420 min/day) showed a significantly higher mean European Quality of Life 5-Dimensions (EQ-5D) index than those with a high sedentary time after adjusting for multiple confounders (0.89 ± 0.03 vs. 0.82 ± 0.04; P = 0.001). Among the EQ-5D dimensions, problems in mobility (OR 3.37; 95% CI 1.42-7.98) and pain/discomfort (OR 2.64; 95% CI 1.24-5.63) dimensions showed positive associations with high sedentary time. Middle- or older-aged breast cancer survivors with insufficient aerobic exercise, diabetes, unemployed status, and impaired quality of life are more likely to have a high sedentary time. Reducing sedentary behavior in this population requires a tailored approach that considers diverse sociodemographic, medical, and quality-of-life factors.


Assuntos
Neoplasias da Mama , Sobreviventes de Câncer , Diabetes Mellitus , Humanos , Feminino , Neoplasias da Mama/epidemiologia , Comportamento Sedentário , Inquéritos Nutricionais , Qualidade de Vida , Vida Independente
3.
Ann Rehabil Med ; 48(1): 42-49, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38200402

RESUMO

OBJECTIVE: To confirm that the simplified insole does not affect the gait speed and to identify objective sensor-based gait parameters that correlate strongly with existing clinical gait assessment scales. METHODS: Ten participants with gait impairment due to hemiplegic stroke were enrolled in this study. Pairs of insoles with four pressure sensors on each side were manufactured and placed in each shoe. Data were extracted during the 10-Meter Walk Test. Several sensor-derived parameters (for example stance time, heel_on-to-toe_peak time, and toe_peak pressure) were calculated and correlated with gait speed and lower extremity Fugl-Meyer (F-M) score. RESULTS: The insole pressure sensor did not affect gait, as indicated by a strong correlation (ρ=0.988) and high agreement (ICC=0.924) between the gait speeds with and without the insole. The parameters that correlated most strongly with highest ß coefficients against the clinical measures were stance time of the non-hemiplegic leg (ß=-0.87 with F-M and ß=-0.95 with gait speed) and heel_on-to-toe_peak time of the non-hemiplegic leg (ß=-0.86 with F-M and -0.94 with gait speed). CONCLUSION: Stance time of the non-hemiparetic leg correlates most strongly with clinical measures and can be assessed using a non-obtrusive insole pressure sensor that does not affect gait function. These results suggest that an insole pressure sensor, which is applicable in a home environment, may be useful as a clinical endpoint in post-stroke gait therapy trials.

4.
Hong Kong J Occup Ther ; 37(1): 31-41, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38912103

RESUMO

Introduction: Wearable sensors are increasingly applied to rehabilitation for arm movement analysis. However, simple and clinically relevant applications are scarce. Objectives: To investigate the feasibility of single smart watch-based parameters for functional assessment in upper limb rehabilitation for musculoskeletal injuries using a commercial smart watch. Method: Ten patients with unilateral shoulder pain and range-of-motion limitations were enrolled. They wore Galaxy Watch® and performed three sets of upper extremity tasks consisting of gross activities-of-daily-living tasks, Wolf Motor Function Test (WMFT), and Upper Extremity Functional Index (UEFI), and the acceleration and angular velocities were acquired. The motion segment size (MSS), representing motion smoothness from a clinical perspective, and various sensor-based parameters were extracted. The correlation between the parameters and clinical outcome measures were analyzed. The percent relative range (PRR) of the significant parameters was also calculated. Results: For overhead and behind body activity task set, mean MSS for elbow flexion/extension axis significantly correlated with WMFT score (R = 0.784, p = .012). For planar tasks, mean MSS for the forearm supination/pronation (R = 0.815, p = .007) and shoulder rotation (R = 0.870, p = .002) axes significantly correlated with WMFT score. For forearm and fine movement task set, mean MSS of the elbow flexion/extension angle showed significant correlation with WMFT (R = 0.880, p < .001) and UEFI (R = 0.718, p = .019). The total performance time (R = -0.741, p = .014) also showed significant correlation with WMFT score. The PRR for mean MSS in forearm supination (71.5%, planar tasks) and mean MSS in x-direction (49.8%, forearm and fine motor movements) were similar to the PRR of WMFT (58.5%), suggesting sufficient variation range across different degree of impairments. Conclusion: The commercial smart watch-based parameters showed consistent potential for use in clinical functional assessments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA