Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Card Fail ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851449

RESUMO

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
Anesthesiology ; 132(2): 267-279, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31939841

RESUMO

BACKGROUND: For cardiac surgery patients under chronic ß-blocker therapy, guidelines recommend their early postoperative reintroduction to decrease the incidence of postoperative atrial fibrillation. The authors hypothesized that the timing of ß-blocker reintroduction affects their effectiveness on the incidence of postoperative atrial fibrillation. METHODS: This multicenter prospective French cohort study included patients on ß-blockers (more than 30 days before surgery) in sinus rhythm without a pacemaker. The primary outcome, time sequence of ß-blocker reintroduction, was analyzed for 192 h after surgery. The secondary outcome, relationship between the occurrence of postoperative atrial fibrillation and timing of ß-blocker reintroduction, was analyzed based on pre- and intraoperative predictors (full and selected sets) according to landmark times (patients in whom atrial fibrillation occurred before a given landmark time were not analyzed). RESULTS: Of 663 patients, ß-blockers were reintroduced for 532 (80%) but for only 261 (39%) patients in the first 48 h after surgery. Median duration before reintroduction was 49.5 h (95% CI, 48 to 51.5 h). Postoperative atrial fibrillation or death (N = 4) occurred in 290 (44%) patients. After performing a landmark analysis to take into account the timing of ß-blocker reintroduction, the adjusted odds ratios (95% CI) for predictor full and selected (increased age, history of paroxysmal atrial fibrillation, and duration of aortic cross clamping) sets for the occurrence of postoperative atrial fibrillation were: adjusted odds ratio (full) = 0.87 (0.58 to 1.32; P = 0.517) and adjusted odds ratio (selected) = 0.84 (0.58 to 1.21; P = 0.338) at 48 h; adjusted odds ratio (full) = 0.64 (0.39 to 1.05; P = 0.076) and adjusted odds ratio (selected) = 0.58 (0.38 to 0.89; P = 0.013) at 72 h; adjusted odds ratio (full) = 0.58 (0.31 to 1.07; P = 0.079) and adjusted odds ratio (selected) = 0.53 (0.31 to 0.91; P = 0.021) at 96 h. CONCLUSIONS: ß-Blockers were reintroduced early (after less than 48 h) in fewer than half of the cardiac surgery patients. Reintroduction decreased postoperative atrial fibrillation occurrence only at later time points and only in the predictor selected set model. These results are an incentive to optimize (timing, doses, or titration) ß-blocker reintroduction after cardiac surgery.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/tendências , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Antagonistas Adrenérgicos beta/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Coortes , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos
3.
Eur Heart J ; 40(11): 928-937, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30541066

RESUMO

AIMS: Inflammatory mediators, including blood cells and their products, contribute critically to atherogenesis, but the igniting triggers of inflammation remain elusive. Atherosclerosis develops at sites of flow perturbation, where the enhanced haemodynamic stress could initiate the atherogenic inflammatory process due to the occurrence of mechanic injury. We investigated the role of haemodynamic stress-induced breaches, allowing the entry of blood cells in the arterial intima, in triggering inflammation-driven atherogenesis. METHODS AND RESULTS: Human coronary samples isolated from explanted hearts, (n = 47) displayed signs of blood entry (detected by the presence of iron, ferritin, and glycophorin A) in the subintimal space (54%) as assessed by histology, immunofluorescence, high resolution episcopic microscopy, and scanning electron microscopy. Computational flow dynamic analysis showed that intimal haemorrhagic events occurred at sites of flow disturbance. Experimental carotid arteries from Apoe deficient mice showed discrete endothelial breaches and intimal haemorrhagic events specifically occurring at the site of flow perturbation, within 3 days after the exacerbation of the local haemodynamic stress. Endothelial tearing was associated with increased VCAM-1 expression and, within 7 days, substantial Ly6G+ leucocytes accumulated at the sites of erythrocyte-derived iron and lipids droplets accumulation, pathological intimal thickening and positive oil red O staining. The formation of fatty streaks at the sites of intimal breaches was prevented by the depletion of Ly6G+ leucocytes, suggesting that the local injury driven by haemodynamic stress-induced breaches triggers atherogenic inflammation. CONCLUSION: Haemodynamic-driven breaches of the arterial intima drive atherogenic inflammation by triggering the recruitment of leucocyte at sites of disturbed arterial flow.


Assuntos
Aterosclerose/metabolismo , Hemodinâmica/fisiologia , Inflamação/patologia , Túnica Íntima/patologia , Animais , Antígenos Ly/metabolismo , Apolipoproteínas E/deficiência , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/metabolismo , Artérias Carótidas/patologia , Vasos Coronários/metabolismo , Vasos Coronários/patologia , Vasos Coronários/ultraestrutura , Células Endoteliais/metabolismo , Células Endoteliais/patologia , Humanos , Leucócitos/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Estresse Mecânico , Túnica Íntima/lesões , Molécula 1 de Adesão de Célula Vascular/metabolismo
4.
Eur Heart J ; 39(28): 2679-2689, 2018 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-29788044

RESUMO

Aims: We analysed the early and long-term clinical and haemodynamic outcomes of balloon-expandable transcatheter mitral valve implantation (TMVI) in an experienced centre. Methods and results: All patients undergoing TMVI from July 2010 to July 2017 in our centre were prospectively included. Indication for TMVI relied on the judgement of the local heart team. Patients were followed at 1 month, 1 year, and yearly thereafter. A total of 91 patients underwent TMVI. The median age was 73 (57-81) years and 70% of patients were women. Patients were at high risk for surgery with a median EuroSCORE II of 9.6 (4.0-14.6) %. Indication for TMVI was bioprosthesis failure (valve-in-valve) in 37.3%, annuloplasty failure (valve-in-ring) in 33.0%, and severe mitral annulus calcification (MAC) in 29.7%. The transseptal approach was used in 92.3% of patients and balloon-expandable valves were used in all patients. Technical success was achieved in 84.6% of patients, one patient died during the procedure and haemodynamically significant left ventricular outflow tract obstruction occurred in three patients (3.3%). At 30 days, 7.7% of patients had died, without significant differences between groups, and a major stroke occurred in 2.2% of patients. The cumulative rates of all-cause mortality at 1-year and 2-year follow-up were 21.0% [95% confidence interval (CI) 9.9-38.8] and 35.7% (95% CI 19.2-56.5), respectively, with a higher late mortality in patients with MAC. The 2-year rates of re-intervention and valve thrombosis were 8.8% and 14.4%, respectively. At 6 months to 1 year, 68.9% of patients were in New York Heart Association Class I or II, and 90.7% of patients had mild or less mitral regurgitation. The mean transmitral gradient decreased from 9.3 ± 3.9 mmHg at baseline to 6.0 ± 2.3 mmHg at discharge (P < 0.001) without changes at 6-month to 1-year follow-up. Conclusion: Transcatheter mitral valve implantation using balloon-expandable valves in selected patients with bioprosthesis or annuloplasty failure or severe MAC was associated with a low rate of peri-procedural complications and acceptable long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
5.
Eur Heart J ; 39(15): 1224-1245, 2018 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-28430909

RESUMO

The VARC (Valve Academic Research Consortium) for transcatheter aortic valve replacement set the standard for selecting appropriate clinical endpoints reflecting safety and effectiveness of transcatheter devices, and defining single and composite clinical endpoints for clinical trials. No such standardization exists for circumferentially sutured surgical valve paravalvular leak (PVL) closure. This document seeks to provide core principles, appropriate clinical endpoints, and endpoint definitions to be used in clinical trials of PVL closure devices. The PVL Academic Research Consortium met to review evidence and make recommendations for assessment of disease severity, data collection, and updated endpoint definitions. A 5-class grading scheme to evaluate PVL was developed in concordance with VARC recommendations. Unresolved issues in the field are outlined. The current PVL Academic Research Consortium provides recommendations for assessment of disease severity, data collection, and endpoint definitions. Future research in the field is warranted.


Assuntos
Valva Aórtica/cirurgia , Ensaios Clínicos como Assunto/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Dispositivos de Oclusão Vascular/normas , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Ensaios Clínicos como Assunto/normas , Ecocardiografia/métodos , Determinação de Ponto Final , Próteses Valvulares Cardíacas/normas , Humanos , Avaliação de Resultados em Cuidados de Saúde , Projetos de Pesquisa , Medição de Risco , Índice de Gravidade de Doença , Suturas
6.
Heart Vessels ; 32(7): 843-849, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28012074

RESUMO

We aimed to investigate the safety and medium-term durability of an adjustable mitral annuloplasty ring in patients undergoing surgery for mitral valve regurgitation. Forty-five patients requiring mitral valve repair were enrolled into this prospective, multicentre study between May 2012 and May 2013 in six hospitals in Europe and Israel. Study endpoints evaluated the performance and safety of the device assessed using inter-individual comparisons. Implantation was performed through a sternotomy in ten patients and mini-thoracotomy in 35 patients. The ring was adjusted after declamping and weaning from cardio-pulmonary bypass under echocardiographic guidance if the coaptation surface was not optimal, or in cases of residual mitral regurgitation. Follow-up was performed up to 2 years post-procedure. Mean age was 61 ± 12 years. Ring adjustment was performed in 71% of patients to optimise the results of mitral valve repair. Following the procedure, 11/45 patients (24%) who had had mild residual mitral regurgitation had no mitral regurgitation following ring adjustment. Two patients with severe mitral regurgitation post-procedure had mild regurgitation following ring adjustment. Coaptation length increased significantly after adjustment. One patient died before hospital discharge due to complications unrelated to the adjustable ring. One patient had to undergo re-operation at 39 days post-procedure due to endocarditis. At 2 years of follow-up, 78% of patients had no residual mitral regurgitation and 22% had mild residual mitral regurgitation. Adjustable mitral annuloplasty ring implantation was safe in all patients. Mitral valve repair with the adjustable ring was durable in all patients who reached 2 years follow-up. CLINICAL TRIAL REGISTRATION: NCT01617720.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Europa (Continente) , Feminino , Seguimentos , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Reoperação/estatística & dados numéricos , Resultado do Tratamento
7.
Transfusion ; 55(1): 51-4, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25052086

RESUMO

BACKGROUND: Bleeding originating in the gastrointestinal (GI) tract is one of the most common adverse events after left ventricular assist device (LVAD) implantation. In these patients, GI bleeding appears to be the consequence of altered hemostasis on the one hand and alterations of the GI microvasculature on the other. CASE REPORT: We report the case of a patient who suffered repeated, severe GI bleeding early after implantation of a HeartMate II continuous-flow LVAD. RESULTS: After failure of conventional treatment strategies, GI bleeding was controlled using repeated transfusions of a purified von Willebrand factor (VWF) concentrate, almost devoid of Factor VIII (Wilfactin, LFB). No episodes of pump thrombosis were noted. Subsequent to VWF transfusions, we observed a progressive normalization of circulating vascular endothelial growth factor levels. CONCLUSIONS: Our data raise the possibility that, in addition to its hemostatic properties, transfusions of VWF might have acted as an antiangiogenic factor.


Assuntos
Hemorragia Gastrointestinal/terapia , Coração Auxiliar/efeitos adversos , Fator de von Willebrand/uso terapêutico , Idoso , Terapia Combinada , Desamino Arginina Vasopressina/uso terapêutico , Embolização Terapêutica , Transfusão de Eritrócitos , Fibrinogênio/uso terapêutico , Hemorragia Gastrointestinal/etiologia , Ventrículos do Coração , Hemostáticos/uso terapêutico , Humanos , Fotocoagulação a Laser , Masculino , Neovascularização Fisiológica/efeitos dos fármacos , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Recidiva , Ácido Tranexâmico/uso terapêutico , Fator de von Willebrand/fisiologia
8.
Arterioscler Thromb Vasc Biol ; 33(9): 2222-32, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23814118

RESUMO

OBJECTIVE: Tissue activation of proteolysis is involved in acute intramural rupture (dissections, acute ascending aortic dissection) and in progressive dilation (aneurysms, thoracic aneurysm of the ascending aorta) of human ascending aorta. The translational aim of this study was to characterize the regulation of antiproteolytic serpin expression in normal, aneurysmal, and dissecting aorta. APPROACH AND RESULTS: We explored expression of protease nexin-1 (PN-1) and plasminogen activator inhibitor-1 and their regulation by the Smad2 signaling pathway in human tissue and cultured vascular smooth muscle cells (VSMCs) of aneurysms (thoracic aneurysm of the ascending aorta; n=46) and acute dissections (acute ascending aortic dissection; n=10) of the ascending aorta compared with healthy aortas (n=10). Both PN-1 and plasminogen activator inhibitor-1 mRNA and proteins were overexpressed in medial tissue extracts and primary VSMC cultures from thoracic aneurysm of the ascending aorta compared with acute ascending aortic dissection and controls. Transforming growth factor-ß induced increased PN-1 expression in control but not in aneurysmal VSMCs. PN-1 and plasminogen activator inhibitor-1 overexpression by aneurysmal VSMCs was associated with increased Smad2 binding on their promoters and, functionally, resulted in VSMC self-protection from plasmin-induced detachment and death. This phenomenon was restricted to aneurysms and not observed in acute dissections. CONCLUSIONS: These results demonstrate that epigenetically regulated PN-1 overexpression promotes development of an antiproteolytic VSMC phenotype and might favor progressive aneurysmal dilation, whereas absence of this counter-regulation in dissections would lead to acute wall rupture.


Assuntos
Aneurisma da Aorta Torácica/metabolismo , Dissecção Aórtica/metabolismo , Músculo Liso Vascular/metabolismo , Miócitos de Músculo Liso/metabolismo , Serpina E2/metabolismo , Proteína Smad2/metabolismo , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/etiologia , Dissecção Aórtica/genética , Dissecção Aórtica/patologia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/genética , Aneurisma da Aorta Torácica/patologia , Valva Aórtica/anormalidades , Doença da Válvula Aórtica Bicúspide , Sítios de Ligação , Biomarcadores/metabolismo , Células Cultivadas , Doença Crônica , Feminino , Fibrilinas , Predisposição Genética para Doença , Genótipo , Doenças das Valvas Cardíacas/complicações , Humanos , Masculino , Síndrome de Marfan/complicações , Síndrome de Marfan/genética , Proteínas dos Microfilamentos/genética , Pessoa de Meia-Idade , Músculo Liso Vascular/patologia , Mutação , Miócitos de Músculo Liso/patologia , Fenótipo , Inibidor 1 de Ativador de Plasminogênio/metabolismo , Regiões Promotoras Genéticas , RNA Mensageiro/metabolismo , Fatores de Risco , Serpina E2/genética , Fatores de Tempo , Fator de Crescimento Transformador beta1/metabolismo , Regulação para Cima
9.
JACC Case Rep ; 29(6): 102237, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38549851

RESUMO

We report a case of a 16-year-old man in cardiogenic shock secondary to On-X mitral prosthesis dysfunction due to leaflet embolization through aortic mechanical prosthesis. He underwent an emergency redo mitral valve replacement and, a few days later, leaflet removal by open aortic surgery with full recovery.

10.
J Heart Valve Dis ; 22(5): 701-3, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24383384

RESUMO

In selected high-risk patients with aortic stenosis, transcatheter aortic valve implantation (TAVI) can provide comparable functional improvement and early survival after surgical aortic valve replacement. However, the long-term outcome after TAVI is still to be determined and the occurrence of aortic dissection has not been systematically reported. Herein, a case is presented of delayed aortic dissection and rupture several months after an uneventful TAVI in a patient with bicuspid aortic valve stenosis.


Assuntos
Aneurisma da Aorta Torácica/etiologia , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos
11.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37843446

RESUMO

OBJECTIVES: Patients undergoing surgical tricuspid valve replacement (TVR) are at high risk of atrioventricular conduction disorders. Because implanting a lead through the tricuspid bioprosthesis is discouraged, the patients who undergo TVR in our centre are usually given a prophylactic epicardial pacemaker. Our aim was to assess the benefits and risks of this strategy. METHODS: Among the patients who underwent TVR with prophylactic epicardial pacemaker implantation, clinical evaluations and pacemaker reports were analysed retrospectively after surgery. The need for cardiac pacing were assessed by characterizing the atrioventricular conduction, while the risks were evaluated by listing and adjudicating post-operative events. RESULTS: A total of 80 patients were analysed (mean age was 57 ± 16 years old, 30% males). TVR was isolated in 28 (35%) patients, but most often associated with another valve surgery. In the postoperative period, heart rhythm was analysed in 59/80 patients during a median follow-up of 35 months. Cardiac pacing was needed in 46% patients: 14% had complete pacing dependency, 17% had high degree AV block, while 15% had a high ventricular pacing rate (>80%). No pre- or per-operative variables could predict cardiac pacing requirement. Post-operatively, a spontaneous heart rate >70 bpm (P = 0.02) and the presence of narrow QRS (P = 0.03) were significantly associated with a lower risk of cardiac pacing requirement. Complications related to epicardial pacemaker were documented in 2 (2.5%) patients. CONCLUSIONS: After TVR, cardiac pacing was needed in 46% of patients for post-operative atrioventricular conduction disorders. This high incidence associated with an acceptable safety profile supports a prophylactic epicardial pacing strategy for the patients undergoing TVR.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Valva Tricúspide/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos
12.
Heart ; 110(2): 132-139, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-37463732

RESUMO

OBJECTIVE: Despite recent advances in surgical and interventional techniques, knowledge on the management of carcinoid heart disease (CHD) remains limited. In a cohort of patients with liver metastases of midgut neuroendocrine tumours (NETs), we aimed to describe the perioperative management and short-term outcomes of CHD. METHODS: From January 2003 to June 2022, consecutive patients with liver metastases of midgut NETs and severe CHD (severe valve disease with symptoms and/or right ventricular enlargement) were included at Beaujon and Bichat hospitals. All patients underwent clinical evaluation and echocardiography. RESULTS: Out of 43 (16%) consecutive patients with severe CHD and liver metastases of midgut NETs, 79% presented with right-sided heart failure. Tricuspid valve replacement was performed in 26 (53%) patients including 19 (73%) cases of combined pulmonary valve replacement. The 30-day postoperative mortality rate was high (19%), and preoperative heart failure was associated with worse survival (p=0.02). Epicardial pacemakers were systematically implanted in operated patients and 25% were permanently paced. A postoperative positive right ventricular remodelling was observed (p<0.001). A greater myofibroblastic infiltration was observed in pulmonary versus tricuspid valves (p<0.001), suggesting that they may have been explanted at an earlier stage of the disease than the tricuspid valve, with therefore potential for evolution. CONCLUSIONS: We observed a high postoperative mortality rate and baseline right-sided heart failure was associated with worse outcome. In surviving patients, a positive right ventricular remodelling was observed. Prospective, multicentre studies are warranted to better define the management strategy and to identify biomarkers associated with outcome in CHD.


Assuntos
Doença Cardíaca Carcinoide , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Neoplasias Hepáticas , Tumores Neuroendócrinos , Humanos , Doença Cardíaca Carcinoide/complicações , Implante de Prótese de Valva Cardíaca/métodos , Tumores Neuroendócrinos/cirurgia , Tumores Neuroendócrinos/complicações , Estudos Prospectivos , Remodelação Ventricular , Insuficiência Cardíaca/complicações , Neoplasias Hepáticas/complicações
13.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36916745

RESUMO

OBJECTIVES: Upper gastrointestinal bleeding (UGIB) is a common complication in adults treated with veno-arterial extracorporeal membrane oxygenation (VA-ECMO) for refractory cardiogenic shock or cardiac arrest. We aimed to determine risk factors, prevalence and outcomes associated with VA-ECMO-associated UGIB in adult patients. METHODS: We conducted a retrospective cohort study (2014-2022) on consecutive VA-ECMO patients in the medical and infectious disease intensive care unit of Bichat-Claude Bernard University Hospital, Paris, France. UGIB was defined as (i) an overt bleeding (haematemesis, melena, haematochezia) or (ii) acute anaemia associated with a lesion diagnosed on upper gastrointestinal endoscopy. VA-ECMO-associated UGIB was defined as an UGIB occurring during VA-ECMO, or up to 10 days after decannulation in patients weaned off extracorporeal membrane oxygenation (ECMO). Cause-specific models were used to identify factors associated with UGIB and death, respectively. RESULTS: Among the 455 patients included, 48 (10%) were diagnosed with UGIB after a median of 12 [7; 23] days following ECMO cannulation. Mortality occurred in 36 (75%) patients with UGIB and 243 (60%) patients without. UGIB patients had longer intensive care unit stays (32 [19; 60] vs 18 [7; 37] days; P < 0.01), longer ECMO (14 [9; 18] vs 7 [4; 11] days; P < 0.01) and mechanical ventilation durations (21 [16; 36] vs 10 [5; 20] days; P < 0.01), as compared to non-UGIB patients. Ninety upper gastrointestinal endoscopies were performed, and the most frequent lesions detected were gastro-duodenal ulcers (n = 23, 26%), leading to 11/90 therapeutic procedures. By multivariable analysis, a history of peptic ulcer [cause-specific hazard ratio (CSHR) 2.93, 95% confidence interval (CI) [1.01; 8.51]], a dual antiplatelet therapy (CSHR 2.0, 95% CI [1.07; 3.72]) and extracorporeal cardiopulmonary resuscitation (CSHR 2.78, 95% CI [1.42; 5.45]) were independently associated with an increased risk of UGIB. CONCLUSIONS: In adult patients under VA-ECMO, a history of gastric ulcer, dual antiplatelet therapy and extracorporeal cardiopulmonary resuscitation were independently associated with an increased risk of UGIB. This study highlights the potential role of acute ischaemia-reperfusion injury in the pathophysiology of VA-ECMO-associated UGIB.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Adulto , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/métodos , Estudos Retrospectivos , Inibidores da Agregação Plaquetária , Hemorragia Gastrointestinal/etiologia
15.
Eur Heart J ; 32(2): 148-57, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21075775

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option in high-risk patients with severe aortic stenosis. AIMS: PARTNER EU is the first study to evaluate prospectively the procedural and mid-term outcomes of transfemoral (TF) or transapical (TA) implantation of the Edwards SAPIEN® valve involving a multi-disciplinary approach. METHODS AND RESULTS: Primary safety endpoints were 30 days and 6 months mortality. Primary efficacy endpoints were haemodynamic and functional improvement at 12 months. One hundred and thirty patients (61 TF, 69 TA), aged 82.1 ± 5.5 years were included. TA patients had higher logistic EuroSCORE (33.8 vs. 25.7%, P = 0.0005) and more peripheral disease (49.3 vs. 16.4%, P< 0.0001). Procedures were aborted in four TA (5.8%) and six TF cases (9.8%). Valve implantation was successful in the remaining patients in 95.4 and 96.4%, respectively. Thirty days and 6 months survival were 81.2 and 58.0% (TA) and 91.8 and 90.2% (TF). In both groups, mean aortic gradient decreased from 46.9 ± 18.1 to 10.9 ± 5.4 mmHg 6 months post-TAVI. In total, 78.1 and 84.8% of patients experienced significant improvement in New York Heart Association (NYHA) class, whereas 73.9 and 72.7% had improved Kansas City Cardiomyopathy Questionnaire (KCCQ) scores in TA and TF cohorts, respectively. CONCLUSION: This first team-based multi-centre European TAVI registry shows promising results in high-risk patients treated by TF or TA delivery. Survival rates differ significantly between TF and TA groups and probably reflect the higher risk profile of the TA cohort. Optimal patient screening, approach selection, and device refinement may improve outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Causas de Morte , Ecocardiografia , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Resultado do Tratamento
16.
Pulm Circ ; 12(3): e12125, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36016669

RESUMO

Doppler echocardiography plays a central role in the assessment of pulmonary hypertension (PAH). We aim to improve quality assessment of systolic pulmonary arterial pressure (SPAP) by applying a cubic polynomial interpolation to digitized tricuspid regurgitation (TR) waveforms. Patients with PAH and advanced lung disease were divided into three cohorts: a derivation cohort (n = 44), a validation cohort (n = 71), an outlier cohort (n = 26), and a non-PAH cohort (n = 44). We digitized TR waveforms and analyzed normalized duration, skewness, kurtosis, and first and second derivatives of pressure. Cubic polynomial interpolation was applied to three physiology-driven phases: the isovolumic phase, ejection phase, and "shoulder" point phase. Coefficients of determination and a Bland-Altman analysis was used to assess bias between methods. The cubic polynomial interpolation of the TR waveform correlated strongly with expert read right ventricular systolic pressure (RVSP) with R 2 > 0.910 in the validation cohort. The biases when compared to invasive SPAP measured within 24 h were 6.03 [4.33; 7.73], -2.94 [1.47; 4.41], and -3.11 [-4.52; -1.71] mmHg, for isovolumic, ejection, and shoulder point interpolations, respectively. In the outlier cohort with more than 30% difference between echocardiographic estimates and invasive SPAP, cubic polynomial interpolation significantly reduced underestimation of RVSP. Cubic polynomial interpolation of the TR waveform based on isovolumic or early ejection phase may improve RVSP estimates.

17.
J Pathol ; 221(1): 37-48, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20186923

RESUMO

Previous studies have described remodelling of the extracellular substratum by matrix metalloproteinases (MMPs) in aortic valves. However, involvement of the fibrinolytic system has not yet been analysed. We hypothesized that plasminogen and plasminogen activator(s) are present in aortic valves and that plasminogen activation could induce the degradation of adhesive proteins and apoptosis of the valvular myofibroblasts. We employed ELISA, western blotting, fibrin-agar zymography, and immunochemistry to detect components of the plasminogen activation system, in samples of aortic valves and valvular myofibroblasts in primary culture. Using myofibroblast cultures, real-time measurement of plasminogen activation was performed in the absence and presence of inhibitors (amiloride, epsilon-aminocaproic acid, and an MMP inhibitor); the degradation of fibronectin was visualized on western blots; and the apoptotic process was assessed by detection of phosphatidylserine exposure (binding of FITC-annexin V) and DNA fragmentation (TUNEL and ELISA). We demonstrate that a time- and plasminogen concentration-dependent generation of plasmin occurs on the surface of cultured valvular myofibroblasts expressing both u-PA and t-PA. Only u-PA appears to activate plasminogen as t-PA is essentially found in complex with PAI-1. Plasmin-dependent degradation of pericellular proteins, such as fibronectin, leads to cell detachment and apoptosis. In conclusion, various proteins of the fibrinolytic system are synthesized in vitro by cultured myofibroblasts from aortic valves, leading to plasmin-dependent cell detachment-induced apoptosis, a biological process named anoikis. The presence of plasminogen in aortic valves suggests that this process may be operating in vivo and may participate in valvular tissue remodelling, as also suggested by the finding of apoptotic cells in valvular tissue. This is the first demonstration of the presence and potential role of enzymes of the fibrinolytic system in aortic valves.


Assuntos
Valva Aórtica/citologia , Apoptose/fisiologia , Fibrinolisina/fisiologia , Fibroblastos/citologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anoikis/fisiologia , Valva Aórtica/enzimologia , Valva Aórtica/patologia , Células Cultivadas , Feminino , Fibrinólise/fisiologia , Doenças das Valvas Cardíacas/enzimologia , Humanos , Masculino , Pessoa de Meia-Idade , Plasminogênio/fisiologia , Ativadores de Plasminogênio/fisiologia , Técnicas de Cultura de Tecidos
18.
J Cardiothorac Vasc Anesth ; 25(6): 1036-43, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21803602

RESUMO

OBJECTIVE: To describe differences in intra- and postoperative care between general (GA) and local/regional anesthesia (LRA) in consecutive high-risk patients with aortic stenosis who underwent transfemoral transcatheter aortic valve implantation (TAVI). DESIGN: A retrospective review of data collected in an institutional registry. SETTING: An academic hospital. PARTICIPANTS: One hundred twenty-five consecutive patients with severe aortic stenosis who underwent transfemoral TAVI. INTERVENTIONS: GA versus LRA followed by postoperative care. Complications were defined by pre-established criteria. MATERIAL AND METHODS: Consecutive patients referred for transfemoral TAVI between October 2006 and October 2010 initially underwent GA (n = 91) followed by LRA after March 2010 (n= 34). Results are presented as mean ± standard deviation or median (25-75 percentiles) as appropriate. GA and LRA TAVI patients had similar preoperative characteristics. LRA was associated with a significantly shorter procedure duration (LRA: 80 [67-102]; GA: 120 [90-140 minutes]; p < 0.001), hospital stay (LRA: 8.5 [7-14.5]; GA: 15.5 [10-24] days; p < 0.001), intraoperative requirements of catecholamines (LRA 23%; GA: 90% of patients; p < 0.001), and volume expansion (LRA: 11 [8-16]; GA: 22 [15-36] mL/kg; p < 0.001). There were significant differences in delta creatinine (day 1, preoperative creatinine values; LRA: 0 [-12 to 9]; GA: -15 (-25 to 2.9) µmol, p < 0.004). The frequency of any postoperative complications was 38% (LRA) and 77% (GA) (p = 0.11). Thirty-day mortality was 7% (GA) and 9% (LRA) (p = 0.9). CONCLUSIONS: This observational study suggests that LRA was associated with less intraoperative hemodynamic instability and significant shortening of the procedure and hospital stay. Changes in the anesthetic technique adapted to changes in TAVI interventional techniques and did not increase the rate of postoperative complications.


Assuntos
Anestesia por Condução , Anestesia Geral , Anestesia Local , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Assistência Perioperatória/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia por Condução/efeitos adversos , Anestesia por Condução/mortalidade , Anestesia Geral/efeitos adversos , Anestesia Geral/mortalidade , Anestesia Local/efeitos adversos , Anestesia Local/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo , Causas de Morte , Estudos de Coortes , Cuidados Críticos , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica/fisiologia , Humanos , Masculino , Estudos Retrospectivos , Decúbito Dorsal , Resultado do Tratamento
19.
Ann 3D Print Med ; 1: 100005, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38620609

RESUMO

Emergency 3D-printing of medical devices came out as a potential solution to tackle shortages during the COVID-19 pandemic. Manufacturing medical devices in small series within hospitals is an exciting perspective in crisis management. Health professionals and additive manufacturing technology are ready for this revolution but regulative adaptations are still required. Here we present the design and production of a suture guide for cardiac surgery as a case study for a 3D-printed medical device manufactured during the COVID-19 pandemic.

20.
Eur J Cardiothorac Surg ; 59(3): 601-609, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33313742

RESUMO

OBJECTIVES: Our goal was to assess the safety, outcomes and complication rate of axillary artery cannulation for venoarterial extracorporeal membrane oxygenation (VA-ECMO). METHODS: A retrospective analysis was conducted on data obtained from the review of medical charts of all consecutive patients undergoing VA-ECMO implantation between January 2013 and December 2017 at a teaching hospital. Only patients with right axillary VA-ECMO implantation in a non-emergency setting were included. Post-procedural outcomes and local and systemic complications were analysed. RESULTS: One hundred and seventy-four [131 male (75.3%), 43 female (24.7%); mean age 56.8 ± 15.1 years] patients underwent femoral-axillary VA-ECMO. Indications were cardiogenic shock from any cause (n = 78, 44.8%) or post-cardiotomy syndrome (n = 96, 55.2%). Fifty-three (30.5%) patients died while on VA-ECMO support. At the time of VA-ECMO ablation, 89 (51.1%) patients had recovered; 13 (7.5%) patients were bridged to a long-term mechanical support device and 19 (10.9%) patients underwent heart transplants. Thirty-day and 1-year mortality was 36.2% (n = 63) and 49.4% (n = 86), respectively. The 1-year survival rate of patients who were weaned from VA-ECMO support was 72.7% (n = 88). The complications of axillary cannulation were bleeding (n = 7, 4%), local infection (n = 3, 1.7%), upper limb ischaemia (n = 2, 1.1%) and brachial plexus injury (n = 1, 0.6%). Left ventricle unloading was required for 9 (5.2%) patients. The median duration of VA-ECMO support was 7 (range 1-26) days. CONCLUSIONS: Right axillary artery cannulation is a safe and reliable method for VA-ECMO support with a low rate of local complications. In the absence of a control group with femoro-femoral cannulation, no definitive conclusion about the superiority of axillary over femoral cannulation can be drawn.


Assuntos
Oxigenação por Membrana Extracorpórea , Adulto , Idoso , Artéria Axilar/cirurgia , Cateterismo , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Choque Cardiogênico/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA