Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Int J Mol Sci ; 24(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37047465

RESUMO

The aim of this in vitro study was to analyze, both experimentally and theoretically, the mechanical behavior of two types of composite materials used in restoring dental integrity. The samples of each composite resin, namely Filtek Supreme XT (3M ESPE, St. Paul, MN, USA) and Filtek Z250 (3M ESPE, St. Paul, MN, USA), were experimentally analyzed by determining their compressive strength and fracture behavior. The fractured fragments of the samples were subjected to surface evaluation by scanning electron microscopy. The compressive stress-compressive strain dependencies revealed stronger cracking of the Filtek Supreme XT composite than Filtek Z250 prior to fracture. Theoretically, the evaluation was made by means of holographic implementations of such types of composite materials. A Hooke-type equation in a differential form is presented, which links the proposed theoretical model with the experimentally obtained data.


Assuntos
Resinas Compostas , Fraturas Ósseas , Humanos , Microscopia Eletrônica de Varredura , Teste de Materiais , Materiais Dentários , Propriedades de Superfície
2.
Medicina (Kaunas) ; 59(2)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36837479

RESUMO

Background and Objectives: The aim of this in vitro study was to evaluate the combined effect of a 2% chlorhexidine aqueous solution and a universal adhesive system applied in self-etch and etch-and-rinse strategies on the composite resin-dentin interface. Materials and Methods: Class V cavities were prepared on the facial and lingual surfaces of forty caries-free molars extracted for orthodontic reasons. The samples were randomly divided into two groups corresponding to the used etching protocol: I-etch-and-rinse; II-self-etch. In each tooth, one cavity was assigned for the control subgroups -IA (n = 20) and IIA (n = 20)-adhesive only, and the opposite cavity was pretreated with a 2% chlorhexidine solution-Gluco CHeX Cerkamed-subgroups IB (n = 20) and IIB (n = 20). Both sets of groups were restored using a universal adhesive system (Single Bond Universal Adhesive, 3M-ESPE) and a bulk-fill composite resin (Filtek One Bulk Fill Restorative, 3M-ESPE). The roots and the pulp tissue were then removed, and a needle connected to a perfusor with 100 mL saline solution was used for pulp pressure simulation with a hydrostatic pressure of 20 cm H2O. Cariogenic attack was simulated using a demineralizing solution for 3 days at a constant temperature of 25 °C. The teeth were then sectioned in a facial-lingual direction and the microleakages at the occlusal and cervical margins were registered and scored using an optical Carl-Zeiss AXIO Imager A1m microscope (Carl-Zeiss). The composite resin-dentin interface was analyzed using a SEM Vega Tescan LMH II. Statistical analysis was performed using the Kruskal-Wallis test with a significance level of p < 0.05. Results: Microleakage evaluation showed no significant differences among the study groups (p > 0.05). In subgroup IA, significant differences were recorded between occlusal and cervical margins (p < 0.05). Conclusions: Application of chlorhexidine on tooth substrate before using a universal bonding system in total etch or self-etch mode has no influence on the adhesive interface in the condition of cariogenic attack. The thickness of the adhesive resin layer seems to be less uniform when using chlorhexidine, but the morphological differences at the adhesive interface have no influence on the sealing capacity of the universal bonding system, regardless of the etching strategy.


Assuntos
Clorexidina , Cimentos de Resina , Humanos , Adesivos Dentinários/química , Resinas Compostas/química , Dentina
3.
Medicina (Kaunas) ; 58(9)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36143826

RESUMO

Background and Objectives: The aim of this in vitro study was to evaluate the effect of simulated gastric acid associated with toothbrushing on the surface condition of three resin-modified glass-ionomer cements (RMGIC). Materials and Methods: One hundred and sixty samples of each material were obtained and included in three study groups according to the tested material: Group I (Ionolux, VOCO GmbH, Cuxhaven, Germany); Group II (Vitremer, 3 M-ESPE, St. Paul, MN, USA); and Group III (Fuji II LC, GC Corporation, Tokyo, Japan). The samples were submersed in hydrochloric acid 0.01 M (pH 3.8) for 3 h and exposed to a toothbrushing procedure at a frequency of 10,000 cycles with medium and hard bristles immediately or 30 min after the acid attack. Profilometric measurements were performed by using a non-contact profilometer (Dektak XT, Bruker, Billerica, MA, USA) in order to assess the surface roughness. ANOVA and Bonferroni post hoc tests were used for the statistical analysis at a significance level of p < 0.05. Results: Exposure of RMGICs to the erosive effect of hydrochloric acid in association with toothbrushing 30 min after the chemical attack increased the surface roughness of all three RMGICs. Exposure of the three tested materials exclusively to the action of hydrochloric acid did not affect the surface roughness. Conclusions: One year of hydrochloric acid challenge associated with one year of toothbrushing with medium-hardness bristles performed 30 min after the acid attack increase the surface roughness of two of the three types of RMGIC tested (Ionolux and Fuji II LC).


Assuntos
Ácido Clorídrico , Escovação Dentária , Ácido Gástrico , Cimentos de Ionômeros de Vidro , Humanos , Teste de Materiais , Propriedades de Superfície
4.
Pharmaceuticals (Basel) ; 17(4)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38675501

RESUMO

A unitary model of drug release dynamics is proposed, assuming that the polymer-drug system can be assimilated into a multifractal mathematical object. Then, we made a description of drug release dynamics that implies, via Scale Relativity Theory, the functionality of continuous and undifferentiable curves (fractal or multifractal curves), possibly leading to holographic-like behaviors. At such a conjuncture, the Schrödinger and Madelung multifractal scenarios become compatible: in the Schrödinger multifractal scenario, various modes of drug release can be "mimicked" (via period doubling, damped oscillations, modulated and "chaotic" regimes), while the Madelung multifractal scenario involves multifractal diffusion laws (Fickian and non-Fickian diffusions). In conclusion, we propose a unitary model for describing release dynamics in polymer-drug systems. In the model proposed, the polymer-drug dynamics can be described by employing the Scale Relativity Theory in the monofractal case or also in the multifractal one.

5.
Diagnostics (Basel) ; 13(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36766635

RESUMO

BACKGROUND: The aim of the study was to assess the protective effect of applying potassium iodide (KI) over silver diamine fluoride (SDF) on demineralized root dentin in the case of a sustained acidogenic attack. METHODS: Forty caries-free third molars were used in the study. A diamond disc was used to separate the roots and the tooth crowns from the roots. Each root fragment was randomly distributed in one of the four study groups: C-samples were not demineralized; DD-demineralized samples; RS1-demineralized samples covered with SDF+KI (RS-Riva Star product, SDI limited, Bayswater, Australia); RS2-demineralized samples covered with SDF+KI and submersed to another acidic challenge for 3 days. SEM and EDX were used for the morphological and elemental analysis. Vickers hardness assessment was performed using a tribometer CETR UMT-2 (Bruker Corporation, Berlin, Germany). One-way ANOVA and post hoc Bonferroni tests were used for the statistical analysis with a significance level of p < 0.05. RESULTS: Morphological and elemental changes were observed on the surface of the study samples. Significant differences were observed between the recorded hardness values of groups C and DD (p = 0.005), C and RS2 (p = 0.002), DD and RS1 (p = 0.011); RS1 and RS2 (p = 0.004). CONCLUSIONS: The application of SDF and KI (Riva Star product) on root dentin caries resulted in the formation of a heterogeneous outer layer that sealed the dentin and increased the microhardness of the treated surface. In the conditions of the present study, this layer did not provide enough protection for root dentin exposed to continuous attacks.

6.
Biomedicines ; 11(9)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37760904

RESUMO

There are two main methods used for dentin hypersensitivity (DH) treatment: dentinal tubule occlusion and blockage of nerve activity. Dentifrices are the most common vehicles for active ingredients used for DH treatment. The aim of this study was to evaluate the efficacy of three toothpastes on dentinal tubule occlusion, mineral acquisition, and dentin hardness. Forty human dentin disks were submerged in 40% citric acid for 30 s and then exposed to tooth brushing for 2 min twice a day for 14 days using three toothpastes: Dontodent Sensitive (group 1), Dr. Wolff's Biorepair (group 2), and Sensodyne Repair and Protect (group 3). In the control group (group 4), the samples were brushed with water. All of the samples were evaluated using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), and Vickers dentin hardness determination. On SEM images, the degree of dentinal tubule occlusion was assessed using a five-grade scale. The mean score values in groups 1-4 were 3.60 ± 0.69, 2.20 ± 0.91, 2.30 ± 1.16, and 5.00 ± 0.00, significantly higher in study groups when compared to the control group (Kruskal Wallis test p < 0.05). EDX evaluation showed significantly higher calcium and phosphorus concentrations in groups 1 and 3 when compared to control group d. The mean values of Vickers dentin hardness numbers in groups 1-4 were 243.03 ± 10.014, 327.38 ± 56.65, 260.29 ± 37.69, and 225.83 ± 29.93, respectively. No statistically significant results were obtained when comparing the hardness mean values in groups (Kruskal-Wallis statistical test, p = 0.372 > 0.05). All three toothpastes tested demonstrated significant occlusion of dentinal tubules. Dontodent Sensitive and Sensodyne Repair and Protect toothpastes enhanced the calcium and phosphorus content of the dentin surface. None of the toothpastes increased dentin hardness as a result of mineral acquisition.

7.
J Funct Biomater ; 14(8)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37623647

RESUMO

The aim of the study was to evaluate the antibacterial activity and surface hardness of a light-activated microhybrid composite resin modified with green silver nanoparticles (AgNPs). AgNPs were synthesized using an Equisetum sylvaticum extract and characterized through different methods such as UV-Vis, EDX, and FTIR. The obtained AgNPs were mixed with a microhybrid composite resin (Herculite XRV, Kerr Corp., Orange, CA, USA) in different concentrations: 0% (group A-control); 0.5% (group B); 1% (group C); and 1.5% (group D). A total of 120 composite resin disk-shaped samples were obtained and divided into 4 groups (n = 30) according to AgNP concentration. Each group was then divided into 2 subgroups: subgroup 1-samples were not soaked in 0.01 M NaOH solution; and subgroup 2-samples were soaked in 0.01 M NaOH solution. The antibacterial activity against Streptococcus mutans was determined using a direct contact test. A digital electronic hardness tester was used to determine the composite resin's Vickers surface hardness (VH). Statistical analysis was performed using the Mann-Whitney U and Kruskal-Wallis nonparametric tests with a confidence level of 95%. Groups C and D showed higher antibacterial activity against S. mutans when compared to the control group (p < 0.05). No significant differences were recorded between VH values (p > 0.05). The use of AgNPs synthesized from Equisetum sylvaticum as a composite resin filler in 1% wt. and 1.5% wt. reduced the activity of Streptococcus mutans. Soaking of the experimental composite resin decreased the antibacterial efficacy. The loading of a microhybrid composite resin with AgNPs in concentrations of 0.5% wt., 1% wt., and 1.5% wt. did not influence the surface hardness.

8.
Gels ; 9(5)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37233013

RESUMO

Two formulations based on diclofenac sodium salt encapsulated into a chitosan hydrogel were designed and prepared, and their drug release was investigated by combining in vitro results with mathematical modeling. To understand how the pattern of drug encapsulation impacted its release, the formulations were supramolecularly and morphologically characterized by scanning electron microscopy and polarized light microscopy, respectively. The mechanism of diclofenac release was assessed by using a mathematical model based on the multifractal theory of motion. Various drug-delivery mechanisms, such as Fickian- and non-Fickian-type diffusion, were shown to be fundamental mechanisms. More precisely, in a case of multifractal one-dimensional drug diffusion in a controlled-release polymer-drug system (i.e., in the form of a plane with a certain thickness), a solution that allowed the model's validation through the obtained experimental data was established. The present research reveals possible new perspectives, for example in the prevention of intrauterine adhesions occurring through endometrial inflammation and other pathologies with an inflammatory mechanism background, such as periodontal diseases, and also therapeutic potential beyond the anti-inflammatory action of diclofenac as an anticancer agent, with a role in cell cycle regulation and apoptosis, using this type of drug-delivery system.

9.
Biomedicines ; 10(5)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35625745

RESUMO

This in vitro study aimed to assess the erosive effect of hydrochloric acid in association with toothbrushing procedure on the surface condition of three bulk-fill composite resins used for direct restoration. A total of 480 samples (160 from each composite resin): X-tra Fil (VOCO, Germany)­group A, Filtek Bulk-fill Posterior (3M-ESPE, St. Paul, MN, USA)­group B, G-aenial Posterior (GC Japan)­group C were prepared, submitted to chemical attack for 60 min with hydrochloric acid 30% and, subsequently, submitted to the abrasive effect of toothbrushing using 10,000 cycles with medium and hard bristles, at three different times (immediately and after 30 min after acid attack or without any chemical attack). The surface roughness of the samples was measured using a noncontact profilometer (Dektak XT, Bruker, Billerica, MA, USA). The values were analyzed using ANOVA and post hoc Bonferroni tests, with a p < 0.05. Chemical attack for 60 min associated with one year of toothbrushing with toothbrushes having medium or hard bristles increase the surface roughness of tested bulk-fill composite resins. No differences were recorded between toothbrushing with medium or firm bristles immediately or 30 min after acidic challenge for each of the three bulk-fill composite resins. Exposure to hydrochloric acid determines no effect on surface roughness of bulk-fill composite resins.

10.
Biomedicines ; 10(7)2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35885060

RESUMO

The aim of the present study was to assess by atomic force microscopy (AFM) the surface roughness of a traditional glass ionomer cement- GIC (Fuji IX GP, GC Corporation, Tokyo, Japan) and a resin modified glass ionomer cement- RMGIC (Vitremer, 3M ESPE, St. Paul, MN, USA) after different immersion regimes on some acidic drinks. Sixteen cylindrical samples having the height of 5 mm and the thickness of 2 mm were obtained from each material and they were divided into two groups: Group I (Fuji IX samples) and Group II (Vitremer samples). Specimens of each group were then randomly divided into 4 subgroups: subgroup A (control)-15 samples were kept in artificial saliva and in the other three subgroups, each having 15 samples the samples were immersed in Coca-Cola (subgroup B), Cappy lemonade and mint (subgroup C) and Fuzetea (subgroup D) for 7 days (subgroups A1-D1), 14 days (subgroups A2-D2), and 21 days (subgroups A3-D3). AFM qualitative and quantitative surface evaluation (mean value of surface roughness parameter, Sa) of each sample was performed. The highest surface roughness was determined when both materials were submerged 14 days in acidic drinks. Traditional GIC was more affected by acidic environment when comparing to RMGIC.

11.
Materials (Basel) ; 15(3)2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35160942

RESUMO

The aim of this in vitro study was to evaluate the effect of hydrochloric acid associated with the abrasive effect of toothbrushing on the surface condition of three flowable composite resins used for direct restoration. Seventy samples of each composite resin: Grandio Flow (VOCO, Germany)-group A, Filtek Ultimate Flow (3M-ESPE, MN, USA)-group B, G-aenial Flo X (GC Europe)-group C were prepared, submersed in hydrochloric acid 30% for 60 min and then submitted to simulated toothbrushing procedure using 5000 cycles with toothbrushes with medium and hard bristles, immediately after the chemical attack, after 30 min or without any chemical attack. The sample's surface roughness was analyzed using a noncontact profilometer (Dektak XT, Bruker, USA). ANOVA and post hoc Bonferroni tests, with a p < 0.05, were used to analyze the values. Hydrochloric acid action for 60 min and six months of toothbrushing using toothbrushes having medium hardness or firm bristles affects the surface roughness of tested flowable composite resins. Toothbrushing with firm bristles immediately after acidic challenge determines increased surface roughness for two of the three flowable composite resins (Grandio Flow and Filtek Ultimate Flow). Toothbrushing with medium or firm bristles thirty minutes after the acidic aggression determine no effect on surface condition of flowable composite resins.

12.
J Immunol Res ; 2022: 1636908, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35571568

RESUMO

Cervical cancer represents a major health problem among females due to its increased mortality rate. The conventional therapies are very aggressive and unsatisfactory when it comes to survival rate, especially in terminal stages, which requires the development of new treatment alternatives. With the use of nanotechnology, various chemotherapeutic drugs can be transported via nanocarriers directly to cervical cancerous cells, thus skipping the hepatic first-pass effect and decreasing the rate of chemotherapy side effects. This review comprises various drug delivery systems that were applied in cervical cancer, such as lipid-based nanocarriers, polymeric and dendrimeric nanoparticles, carbon-based nanoparticles, metallic nanoparticles, inorganic nanoparticles, micellar nanocarriers, and protein and polysaccharide nanoparticles. Nanoparticles have a great therapeutic potential by increasing the pharmacological activity, drug solubility, and bioavailability. Through their mechanisms, they highly increase the toxicity in the targeted cervical tumor cells or tissues by linking to specific ligands. In addition, a nondifferentiable model is proposed through holographic implementation in the dynamics of drug delivery dynamics. As any hologram functions as a deep learning process, the artificial intelligence can be proposed as a new analyzing method in cervical cancer.


Assuntos
Antineoplásicos , Nanopartículas , Neoplasias do Colo do Útero , Antineoplásicos/efeitos adversos , Inteligência Artificial , Portadores de Fármacos , Sistemas de Liberação de Medicamentos/métodos , Feminino , Humanos , Neoplasias do Colo do Útero/tratamento farmacológico
13.
J Immunol Res ; 2021: 2727174, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34957311

RESUMO

Endometriosis is considered a serious public health issue because of the large number of females affected by this illness. Chronic pain management in patients with endometriosis demands new strategies to increase the life quality of these patients. The development of drug delivery systems represents a new approach in pain treatment among endometriosis patients. Diclofenac sodium, one of the most utilized nonsteroidal anti-inflammatory drugs (NSAID), has its own limitations when being used in formulas such as oral, parental, or local applications. In this paper, a series of four drug release formulations based on chitosan, 2-hydroxy-5-nitrobenzaldehyde, and diclofenac sodium salt were prepared in view of the investigation of the drug release ability. The formulations were analyzed from a morphological and supramolecular point of view by scanning electron microscopy and polarized light microscopy. The in vitro drug release ability was investigated by mimicking a physiologic environment. A mathematical model, using the fractal paradigm of motion, is utilized to explain the behaviors of the drug delivery system presented in this paper. These results suggest a great potential of the proposed drug delivery system, based on chitosan and 2-hydroxy-5-nitrobenzaldehyde to improve the diclofenac sodium salt bioavailability, and it may represent a future treatment formula for endometriosis pain.


Assuntos
Dor Abdominal/tratamento farmacológico , Dor Abdominal/etiologia , Composição de Medicamentos , Sistemas de Liberação de Medicamentos , Endometriose/complicações , Manejo da Dor , Algoritmos , Quitosana , Diclofenaco , Liberação Controlada de Fármacos , Feminino , Humanos , Modelos Teóricos , Manejo da Dor/métodos
14.
J Radiol Case Rep ; 11(8): 16-23, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29299102

RESUMO

Gastric duplication cyst is a very rare congenital anomaly accounting up to 4% of all gastrointestinal tract duplications. It is a quite rare anomaly in adults, the majority of the cases are diagnosed in the neonatal period. Gastric duplication cysts are usually asymptomatic or they do present with non-specific symptoms. They are usually discovered incidentally during endoscopy or laparotomy or very rarely after getting complicated. We describe herein, along with literature review, a case of an adult patient who presented with abdominal pain and bloody vomiting and turned out to have a gastric duplication cyst complicated by internal bleeding.


Assuntos
Cistos/diagnóstico por imagem , Anormalidades do Sistema Digestório/diagnóstico por imagem , Estômago/diagnóstico por imagem , Dor Abdominal/etiologia , Adulto , Cistos/congênito , Cistos/patologia , Cistos/cirurgia , Anormalidades do Sistema Digestório/complicações , Anormalidades do Sistema Digestório/patologia , Anormalidades do Sistema Digestório/cirurgia , Feminino , Hematemese/etiologia , Hematemese/cirurgia , Humanos , Estômago/anormalidades , Estômago/patologia , Estômago/cirurgia
15.
Rev Med Chir Soc Med Nat Iasi ; 113(3): 892-8, 2009.
Artigo em Ro | MEDLINE | ID: mdl-20191851

RESUMO

The thermal and structural properties of nano-filled and micro-filled restorative composites (Filtek Supreme XT and Filtek Z250) are studied in comparison with the ones of teeth. Our results show slightly decreased values of the thermal constants of Filtek Supreme XT with respect of Filtek Z250. Both analyzed composite materials have the values of the thermal conductivity and diffusivity very close to the one of enamel, with the better fitting in the case of Filtek Supreme XT. Comparing the effusivities, a good compatibility with all dental tissues resulted. The thermal expansion coefficient is about two times higher for Filtek Supreme XT than Filtek Z250 which fits better with the one of teeth. The chemical composition is similar for both composites except for zirconium which indicate a lower percent of zirconia particle for Filtek Supreme XT.


Assuntos
Resinas Compostas/química , Esmalte Dentário , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Humanos , Teste de Materiais , Zircônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA