Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Fluoresc ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652359

RESUMO

The mercury-loving unit aminothiourea was introduced into the xanthene fluorophore to synthesized the probe molecule NXH. NXH has a specific response to Hg2+, and with the addition of (0 ~ 50 µM) Hg2+, the fluorescence intensity of the probe solution was quenched from 2352 a.u. to about 308 a.u. NXH exhibited excellent detection performance of high sensitivity (LOD = 96.3 nM), real-time response (105 s), wide pH range (2.1 ~ 9.3), and strong anti-interference ability for Hg2+. At the same time, NXH has wide range of applications for Hg2+ detection, which can fluorescence imaging of Hg2+ in Hela cells and tea samples, and can also be made into Hg2+ detection test paper.

2.
Luminescence ; 39(1): e4613, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37927147

RESUMO

Hypochlorous acid (HClO/ClO- ) is one of the important reactive oxygen species (ROS). It acts as a second signaling molecule within and between cells and is an indispensable active molecule in living organisms to regulate physiological and pathological processes. In this article, two fluorescent probes (PTF and PTA) for highly selective fluorescent recognition of ClO- were successfully synthesized based on the ICT mechanism by condensing phenothiazines with two hydrazides via the hydrazide structure (). PTF can identify different concentrations of ClO- in two steps. Due to its ClO- two site recognition, the probe exhibited good selectivity (specific recognition of ClO- over a wide concentration range), a fast time response (rapid recognition in seconds), a sufficiently low detection limit (3.6 and 11.0 nM), and large Stokes shifts (180 and 145 nm). Furthermore, the recognition of ClO- by contrasting probes with different substituents exhibited different fluorescence changes of ratiometric type and turn-off. PTF successfully achieves the detection of exogenous and endogenous ClO- in aqueous solution and living cells.


Assuntos
Corantes Fluorescentes , Ácido Hipocloroso , Corantes Fluorescentes/química , Limite de Detecção , Microscopia de Fluorescência , Hidrazinas
3.
Anal Biochem ; 677: 115232, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481195

RESUMO

In view of the superior chemical activity of selenoether bond (-Se-) and the excellent optical properties of naphthimide, a novel fluorescent probe (NapSe) with near-rectangular structure, which contains double naphthimide fluorophores linked by selenoether bond, is designed for specific fluorescence detection of hydrogen sulfide (H2S). NapSe has excellent optical properties: super large Stokes Shift (190 nm) and good stability in a wide pH range. The selectivity of NapSe fluorescence detection of H2S is high, and displays excellent "turn-on" phenomenon and strong anti-interference. And the fluorescence intensity increased obviously, reaching 42 times. The time response of probe NapSe is very rapid (3 min) compared with other fluorescence probes that respond to H2S. It shows high sensitivity by calculating the detection limit (LOD) as low as 5.4 µM. Notably, the identification of H2S by probe NapSe has been successfully applied to the detection of test paper and the detection of exogenous and endogenous fluorescence imaging of MCF-7 breast cancer cells.


Assuntos
Corantes Fluorescentes , Sulfeto de Hidrogênio , Humanos , Corantes Fluorescentes/química , Células MCF-7 , Imagem Óptica , Espectrometria de Fluorescência , Células HeLa
4.
Anal Biochem ; 670: 115131, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37001597

RESUMO

Hypochlorite (ClO-) plays a key role in life systems and it is necessary to develop an effective detection method. In view of the significant advantages of the fluorescent probe, we have synthesized a naked-eye recognition fluorescent probe NNCF for the detection of ClO- based on phenothiazine and naphthalimide. The probe NNCF is sensitive (LOD = 9.5 nM) and fast for ClO- (within 30 s), and its Stokes shift is as large as 161 nm. In addition, the probe NNCF has been successfully used for imaging detection of exogenous ClO- in MCF-7 cells with low toxicity.


Assuntos
Corantes Fluorescentes , Ácido Hipocloroso , Humanos , Cor de Olho , Fenotiazinas
5.
J Fluoresc ; 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38060150

RESUMO

For the efficient detection of Hg2+ and ClO-, a double-analyte-responsive fluorescent probe PTB was successfully synthesized by combining N-butyl-3-formyl phenothiazine with hydrazine benzothiazole, and designing a specific reaction site for recognizing two analytes (Hg2+ and ClO-) in a compound. It was shown that probe PTB successfully formed a stable complex with Hg2+ in the coordination ratio of 2:1 by using the strong sulfur affinity of Hg2+, which resulted in a remarkable "turn-off" effect, with a quenching efficiency of 92.5% and four reversible cycles of Hg2+ fluorescence detection. For the fluorescence detection of Hg2+, the response time is fast (≤ 2 min) and the detection limit is low (7.8 nM), showing extremely high sensitivity, and the performance is obviously better than that of the reported fluorescent probes for detecting Hg2+. In particular, probe PTB has low toxicity and good biocompatibility, and has been successfully used for imaging of Hg2+ in living cells. Moreover, probe PTB uses thioether bond and carbon-nitrogen double bond as reaction sites to detect ClO-, which has large Stokes Shift (149 nm), good selectivity, high quenching efficiency (96.5%) and fast time response (about 10 s), and successfully detects ClO- in actual water samples. The dual functional fluorescent probe PTB is sensitive for Hg2+ and ClO-. It has been successfully used for making pH fluorescent test paper and imaging detection of exogenous Hg2+ in VSMC cells with low toxicity.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 300: 122917, 2023 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-37269662

RESUMO

On the basis of classical Schiff base reaction, two novel and efficient fluorescent probes (DQNS, DQNS1) were designed and synthesized by introducing Schiff base structure into dis-quinolinone unit for structural modification, which can be used to detect Al3+ and ClO-. Because the power supply capacity of H is weaker than that of methoxy, DQNS shows better optical performance: a large Stokes Shift (132 nm), identify Al3+ and ClO- with high sensitivity and selectivity, low detection limit (29.8 nM and 25 nM) and fast response time (10 min and 10 s). Through the working curve and NMR titration experiment, the recognition mechanism of Al3+ and ClO- (PET and ICT) probes are confirmed. Meanwhile, it is speculated that the probe has continuity for the detection of Al3+ and ClO-. Furthermore, DQNS detection of Al3+ and ClO- was applied to real water samples and living cell imaging.


Assuntos
Corantes Fluorescentes , Bases de Schiff , Corantes Fluorescentes/química , Bases de Schiff/química , Imagem Óptica/métodos , Ácido Hipocloroso/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA