Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37294671

RESUMO

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 45(9): 1115-1123, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35583311

RESUMO

BACKGROUND: It is unknown whether His-Purkinje conduction system pacing (HPCSP), as either His bundle or left bundle branch pacing, could be an alternative to cardiac resynchronization therapy (BiVCRT) for patients with left ventricular dysfunction needing ventricular pacing due to atrioventricular block. The aim of the study is to compare the echocardiographic response and clinical improvement between HPCSP and BiVCRT. METHODS: Consecutive patients who successfully received HPCSP were compared with a historical cohort of BiVCRT patients. Patients were 1:1 matched by age, LVEF, atrial fibrillation, renal function and cardiomyopathy type. Responders were defined as patients who survived, did not require heart transplantation and increased LVEF ≥5 points at 6-month follow-up. RESULTS: HPCSP was successfully achieved in 92.5% (25/27) of patients. During follow-up, 8% (2/25) of HPCSP patients died and 4% (1/25) received a heart transplant, whereas 4% (1/25) of those in the BiVCRT cohort died. LVEF improvement was 10% ± 8% HPCSP versus 7% ± 5% BiVCRT (p = .24), and the percentage of responders was 76% (19/25) HPCSP versus 64% (16/25) BiVCRT (p = .33). Among survivors, the percentage of patients who improved from baseline II-IV mitral regurgitation (MR) to 0-I MR was 9/11 (82%) versus 2/8 (25%) (p = .02). Compared to those with BiVCRT, patients with HPCSP achieved better NYHA improvement: 1 point versus 0.5 (OR 0.34; p = .02). CONCLUSION: HPCSP in patients with LVEF ≤45% and atrioventricular block improved the LVEF and induced a response similar to that of BiVCRT. HPCSP significantly improved MR and NYHA functional class. HPCSP may be an alternative to BiVCRT in these patients. (Figure 1. Central Illustration). [Figure: see text].


Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular , Fascículo Atrioventricular , Doença do Sistema de Condução Cardíaco , Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular/etiologia , Disfunção Ventricular/terapia , Função Ventricular Esquerda
3.
Pacing Clin Electrophysiol ; 45(3): 374-383, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35015308

RESUMO

BACKGROUND: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. METHODS: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. RESULTS: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). CONCLUSION: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Estimulação Cardíaca Artificial , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/prevenção & controle , Função Ventricular Esquerda
4.
Indian Pacing Electrophysiol J ; 19(4): 140-144, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30794927

RESUMO

AIMS: Riata® implantable cardioverter-defibrillator (ICD) leads from St. Jude Medical are prone to malfunction. This study aimed to describe the rate of this lead's malfunction in a very long-term follow-up. METHODS: This single-centre observational study included 50 patients who received a Riata 7Fr dual-coil lead between 2003 and 2008. Follow-up was conducted both in person and remotely, and analysed at 8-month intervals. We evaluated the rates of cable externalization (CE), electrical failure (EF), and the interaction of these two complications. Structural lead failure was defined as radiographic CE. Oversensing of non-cardiac signal or sudden changes in impedance, sensing, or pacing thresholds constituted EF. RESULTS: During a mean follow-up of 10.2 ±â€¯2.9 years, 16 patients (32%) died. We observed lead malfunction in 13 patients (26%): three (23%) due to CE, six (46%) to EF and four (31%) to both complications. Of the malfunctioning leads, 77% failed after seven years of follow-up. The incidence rate (IR) of overall malfunction per 100 patients per year was 0.9 during the first seven years post-implantation, increased to 7.0 after the 7th year and more than doubled (to 16.7) after 10 years. Beyond seven years post-implantation, IR per 100 patient-years increased in both EF and CE (from 0.6 to 5.6 vs. 0.3 to 4.2, respectively). Presence of CE was associated with a 4-fold increase in the proportion of EF. CONCLUSION: The incidence of Riata ICD lead malfunction, both for EF and CE, increased dramatically after seven years and then more than doubled after 10 years post-implantation.

5.
Heart Rhythm ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38906515

RESUMO

BACKGROUND: Left bundle branch pacing (LBBP) is considered an alternative to cardiac resynchronization therapy (CRT). However, LBBP is not suitable for all patients with heart failure. OBJECTIVE: The aim of our study was to identify predictors of unsuccessful LBBP implantation in CRT candidates. METHODS: A cohort of consecutive patients with indications for CRT were included. Clinical, echocardiographic, and electrocardiographic variables were prospectively recorded. RESULTS: A total of 187 patients were included in the analysis. LBBP implantation was successful in 152 of 187 patients (81.2%) and failed in 35 of 187 patients (18.7%). The causes of unsuccessful implantation were unsatisfactory paced QRS morphology (28 of 35 [80%]), inability to screw the helix (4 of 35 [11.4%]), lead instability (2 of 35 [5.7%]), and high pacing thresholds (1 of 35 [2.8%]). The left ventricular end-diastolic diameter (LVEDD), non-LBBB (left bundle branch block) QRS morphology, and QRS width were predictors of failed implantation according to the univariate analysis. According to the multivariate regression analysis, LVEDD (odds ratio 1.31 per 5-mm increase; 95% confidence interval 1.05-1.63 per 5-mm increase; P = .02) and non-LBBB (odds ratio 3.07; 95% confidence interval 1.08-8.72; P = .03) were found to be independent predictors of unsuccessful LBBP implantation. An LVEDD of 60 mm has 60% sensitivity and 71% specificity for predicting LBBP implant failure. CONCLUSION: When LBBP was used as CRT, LVEDD and non-LBBB QRS morphology predicted unsuccessful implantation. Non-LBBB triples the likelihood of failed implantation independent of LVEDD. Caution should be taken when considering these parameters to plan the best pacing strategy for patients.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38768299

RESUMO

Longitudinal dyssynchrony correction and strain improvement by comparable cardiac resynchronization therapy techniques is unreported. AIMS: Our purpose was to compare echocardiographic dyssynchrony correction and strain improvement by conduction system pacing (CSP) vs. biventricular pacing (BiVP) as a marker of contractility improvement during one-year follow-up. METHODS AND RESULTS: A treatment-received analysis was performed in patients included in the LEVEL-AT trial (NCT04054895), randomized to CSP or BiVP, and evaluated at baseline (ON and OFF programming) and at 6 and 12 months (n = 69, 32% women). Analysis included intraventricular (septal flash), interventricular (difference between left and right ventricular outflow times), and atrioventricular (diastolic filling time) dyssynchrony and strain parameters (septal bounce, global longitudinal strain [GLS], left bundle branch block pattern and mechanical dispersion).Baseline left ventricular ejection fraction (LVEF) was 27.5 ± 7% and left ventricular end-systolic volume (LVESV) was 138 ± 77 ml, without differences between groups. Longitudinal analysis showed LVEF and LVESV improvement (p < 0.001), without between-group differences. At 12-month follow-up, adjusted mean LVEF was 46% with CSP (95%CI 42.2%, 49.3%) vs. 43% with BiVP (95%CI 39.6%, 45.8%) (p = 0.31) and LVESV was 80 ml (95%CI 55.3 ml, 104.5 ml) vs. 100 ml (95%CI 78.7 ml, 121.6 ml), respectively (p = 0.66).Longitudinal analysis showed a significative improvement of all dyssynchrony parameters and GLS over time (p < 0.001), without differences between groups. Baseline GLS significantly correlated with LVEF and LVESV at 12-month follow-up. CONCLUSION: CSP and BiVP provided similar dyssynchrony and strain correction over time. Baseline global longitudinal strain correction predicted ventricular remodeling at 12-month follow-up.

7.
JACC Clin Electrophysiol ; 8(11): 1431-1445, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36424012

RESUMO

BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Bloqueio de Ramo , Doença do Sistema de Condução Cardíaco/terapia , Remodelação Ventricular
8.
Heart Rhythm ; 16(12): 1849-1854, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31125672

RESUMO

BACKGROUND: The Micra transcatheter pacing system (Micra TPS) is often implanted in patients with atrial fibrillation and thus with increased thromboembolic risk. It is unknown whether the use of anticoagulants, associated with the use of a large venous introducer, implies an increased risk of bleeding in this group of patients. OBJECTIVE: The purpose of this study was to assess the incidence of bleeding and thromboembolic complications after Micra TPS implantation with and without therapeutic anticoagulation. METHODS: This single-center observational study included 107 consecutive patients receiving the Micra TPS from 2014 to 2018. At procedure completion, a figure-of-eight suture was placed at the femoral puncture site after sheath withdrawal and was maintained for 24 hours. In patients receiving enoxaparin or new oral anticoagulants, treatment was discontinued 12 or 24 hours before the procedure, respectively, and was reinitiated 4-6 hours postprocedure. In those receiving vitamin K antagonists (VKAs), dosing was not discontinued and the procedure was performed if the international normalized ratio was less than 3. RESULTS: Sixty-four patients (60%) did not receive anticoagulants. Of the 43 (40%) who did, 29 (67%) received VKAs, 8 (19%) received new oral anticoagulants, and 6 (14%) received enoxaparin. Two patients presented hemorrhagic or thromboembolic complications during short-term follow-up: 1 woman receiving VKAs presented hemorrhagic pericardial effusion without tamponade and 1 woman not receiving anticoagulants presented thrombosis of the ipsilateral saphenous vein. CONCLUSION: Bleeding and thromboembolic complications after receiving Micra TPSs are infrequent. The use of anticoagulant therapy, regardless of the type, does not increase the complications associated with the procedure.


Assuntos
Anticoagulantes , Fibrilação Atrial , Cateterismo Periférico , Hemorragia , Tromboembolia , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Anticoagulantes/classificação , Fibrilação Atrial/sangue , Fibrilação Atrial/terapia , Coagulação Sanguínea/efeitos dos fármacos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Hemorragia/epidemiologia , Humanos , Masculino , Conduta do Tratamento Medicamentoso , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial , Risco Ajustado/métodos , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA