Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 756
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 623(7985): 106-114, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37880365

RESUMO

Maturation of the human fetal brain should follow precisely scheduled structural growth and folding of the cerebral cortex for optimal postnatal function1. We present a normative digital atlas of fetal brain maturation based on a prospective international cohort of healthy pregnant women2, selected using World Health Organization recommendations for growth standards3. Their fetuses were accurately dated in the first trimester, with satisfactory growth and neurodevelopment from early pregnancy to 2 years of age4,5. The atlas was produced using 1,059 optimal quality, three-dimensional ultrasound brain volumes from 899 of the fetuses and an automated analysis pipeline6-8. The atlas corresponds structurally to published magnetic resonance images9, but with finer anatomical details in deep grey matter. The between-study site variability represented less than 8.0% of the total variance of all brain measures, supporting pooling data from the eight study sites to produce patterns of normative maturation. We have thereby generated an average representation of each cerebral hemisphere between 14 and 31 weeks' gestation with quantification of intracranial volume variability and growth patterns. Emergent asymmetries were detectable from as early as 14 weeks, with peak asymmetries in regions associated with language development and functional lateralization between 20 and 26 weeks' gestation. These patterns were validated in 1,487 three-dimensional brain volumes from 1,295 different fetuses in the same cohort. We provide a unique spatiotemporal benchmark of fetal brain maturation from a large cohort with normative postnatal growth and neurodevelopment.


Assuntos
Encéfalo , Desenvolvimento Fetal , Feto , Pré-Escolar , Feminino , Humanos , Gravidez , Encéfalo/anatomia & histologia , Encéfalo/embriologia , Encéfalo/crescimento & desenvolvimento , Feto/embriologia , Idade Gestacional , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/embriologia , Substância Cinzenta/crescimento & desenvolvimento , Voluntários Saudáveis , Internacionalidade , Imageamento por Ressonância Magnética , Tamanho do Órgão , Estudos Prospectivos , Organização Mundial da Saúde , Imageamento Tridimensional , Ultrassonografia
2.
Nat Methods ; 20(9): 1409-1416, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37474808

RESUMO

Understanding the routing of neuronal information requires the functional characterization of connections. Neuronal projections recruit large postsynaptic ensembles with distinct postsynaptic response types (PRTs). PRT is typically probed by low-throughput whole-cell electrophysiology and is not a selection criterion for single-cell RNA-sequencing (scRNA-seq). To overcome these limitations and target neurons based on specific PRTs for soma harvesting and subsequent scRNA-seq, we created Voltage-Seq. We established all-optical voltage imaging and recorded the PRT of 8,347 neurons in the mouse periaqueductal gray (PAG) evoked by the optogenetic activation of ventromedial hypothalamic (VMH) terminals. PRTs were classified and spatially resolved in the entire VMH-PAG connectome. We built an onsite analysis tool named VoltView to navigate soma harvesting towards target PRTs guided by a classifier that used the VMH-PAG connectome database as a reference. We demonstrated Voltage-seq by locating VMH-driven γ-aminobutyric acid-ergic neurons in the PAG, guided solely by the onsite classification in VoltView.


Assuntos
Conectoma , Camundongos , Animais , Transcriptoma , Neurônios/fisiologia , Substância Cinzenta Periaquedutal/fisiologia
3.
Br J Anaesth ; 132(5): 1049-1062, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38448269

RESUMO

BACKGROUND: Artificial intelligence (AI) for ultrasound scanning in regional anaesthesia is a rapidly developing interdisciplinary field. There is a risk that work could be undertaken in parallel by different elements of the community but with a lack of knowledge transfer between disciplines, leading to repetition and diverging methodologies. This scoping review aimed to identify and map the available literature on the accuracy and utility of AI systems for ultrasound scanning in regional anaesthesia. METHODS: A literature search was conducted using Medline, Embase, CINAHL, IEEE Xplore, and ACM Digital Library. Clinical trial registries, a registry of doctoral theses, regulatory authority databases, and websites of learned societies in the field were searched. Online commercial sources were also reviewed. RESULTS: In total, 13,014 sources were identified; 116 were included for full-text review. A marked change in AI techniques was noted in 2016-17, from which point on the predominant technique used was deep learning. Methods of evaluating accuracy are variable, meaning it is impossible to compare the performance of one model with another. Evaluations of utility are more comparable, but predominantly gained from the simulation setting with limited clinical data on efficacy or safety. Study methodology and reporting lack standardisation. CONCLUSIONS: There is a lack of structure to the evaluation of accuracy and utility of AI for ultrasound scanning in regional anaesthesia, which hinders rigorous appraisal and clinical uptake. A framework for consistent evaluation is needed to inform model evaluation, allow comparison between approaches/models, and facilitate appropriate clinical adoption.


Assuntos
Anestesia por Condução , Inteligência Artificial , Humanos , Ultrassonografia , Simulação por Computador , Bases de Dados Factuais
4.
Br J Anaesth ; 130(2): 226-233, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36088136

RESUMO

BACKGROUND: Ultrasound-guided regional anaesthesia relies on the visualisation of key landmark, target, and safety structures on ultrasound. However, this can be challenging, particularly for inexperienced practitioners. Artificial intelligence (AI) is increasingly being applied to medical image interpretation, including ultrasound. In this exploratory study, we evaluated ultrasound scanning performance by non-experts in ultrasound-guided regional anaesthesia, with and without the use of an assistive AI device. METHODS: Twenty-one anaesthetists, all non-experts in ultrasound-guided regional anaesthesia, underwent a standardised teaching session in ultrasound scanning for six peripheral nerve blocks. All then performed a scan for each block; half of the scans were performed with AI assistance and half without. Experts assessed acquisition of the correct block view and correct identification of sono-anatomical structures on each view. Participants reported scan confidence, experts provided a global rating score of scan performance, and scans were timed. RESULTS: Experts assessed 126 ultrasound scans. Participants acquired the correct block view in 56/62 (90.3%) scans with the device compared with 47/62 (75.1%) without (P=0.031, two data points lost). Correct identification of sono-anatomical structures on the view was 188/212 (88.8%) with the device compared with 161/208 (77.4%) without (P=0.002). There was no significant overall difference in participant confidence, expert global performance score, or scan time. CONCLUSIONS: Use of an assistive AI device was associated with improved ultrasound image acquisition and interpretation. Such technology holds potential to augment performance of ultrasound scanning for regional anaesthesia by non-experts, potentially expanding patient access to these techniques. CLINICAL TRIAL REGISTRATION: NCT05156099.


Assuntos
Anestesia por Condução , Bloqueio Nervoso , Humanos , Bloqueio Nervoso/métodos , Inteligência Artificial , Ultrassonografia de Intervenção/métodos , Anestesia por Condução/métodos , Ultrassonografia
5.
Br J Anaesth ; 130(2): 217-225, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35987706

RESUMO

BACKGROUND: Ultrasonound is used to identify anatomical structures during regional anaesthesia and to guide needle insertion and injection of local anaesthetic. ScanNav Anatomy Peripheral Nerve Block (Intelligent Ultrasound, Cardiff, UK) is an artificial intelligence-based device that produces a colour overlay on real-time B-mode ultrasound to highlight anatomical structures of interest. We evaluated the accuracy of the artificial-intelligence colour overlay and its perceived influence on risk of adverse events or block failure. METHODS: Ultrasound-guided regional anaesthesia experts acquired 720 videos from 40 volunteers (across nine anatomical regions) without using the device. The artificial-intelligence colour overlay was subsequently applied. Three more experts independently reviewed each video (with the original unmodified video) to assess accuracy of the colour overlay in relation to key anatomical structures (true positive/negative and false positive/negative) and the potential for highlighting to modify perceived risk of adverse events (needle trauma to nerves, arteries, pleura, and peritoneum) or block failure. RESULTS: The artificial-intelligence models identified the structure of interest in 93.5% of cases (1519/1624), with a false-negative rate of 3.0% (48/1624) and a false-positive rate of 3.5% (57/1624). Highlighting was judged to reduce the risk of unwanted needle trauma to nerves, arteries, pleura, and peritoneum in 62.9-86.4% of cases (302/480 to 345/400), and to increase the risk in 0.0-1.7% (0/160 to 8/480). Risk of block failure was reported to be reduced in 81.3% of scans (585/720) and to be increased in 1.8% (13/720). CONCLUSIONS: Artificial intelligence-based devices can potentially aid image acquisition and interpretation in ultrasound-guided regional anaesthesia. Further studies are necessary to demonstrate their effectiveness in supporting training and clinical practice. CLINICAL TRIAL REGISTRATION: NCT04906018.


Assuntos
Anestesia por Condução , Bloqueio Nervoso , Humanos , Bloqueio Nervoso/métodos , Inteligência Artificial , Ultrassonografia de Intervenção/métodos , Anestesia por Condução/métodos , Ultrassonografia
6.
Ultrasound Obstet Gynecol ; 60(6): 759-765, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35726505

RESUMO

OBJECTIVE: Despite decades of obstetric scanning, the field of sonographer workflow remains largely unexplored. In the second trimester, sonographers use scan guidelines to guide their acquisition of standard planes and structures; however, the scan-acquisition order is not prescribed. Using deep-learning-based video analysis, the aim of this study was to develop a deeper understanding of the clinical workflow undertaken by sonographers during second-trimester anomaly scans. METHODS: We collected prospectively full-length video recordings of routine second-trimester anomaly scans. Important scan events in the videos were identified by detecting automatically image freeze and image/clip save. The video immediately preceding and following the important event was extracted and labeled as one of 11 commonly acquired anatomical structures. We developed and used a purposely trained and tested deep-learning annotation model to label automatically the large number of scan events. Thus, anomaly scans were partitioned as a sequence of anatomical planes or fetal structures obtained over time. RESULTS: A total of 496 anomaly scans performed by 14 sonographers were available for analysis. UK guidelines specify that an image or videoclip of five different anatomical regions must be stored and these were detected in the majority of scans: head/brain was detected in 97.2% of scans, coronal face view (nose/lips) in 86.1%, abdomen in 93.1%, spine in 95.0% and femur in 92.3%. Analyzing the clinical workflow, we observed that sonographers were most likely to begin their scan by capturing the head/brain (in 24.4% of scans), spine (in 23.2%) or thorax/heart (in 22.8%). The most commonly identified two-structure transitions were: placenta/amniotic fluid to maternal anatomy, occurring in 44.5% of scans; head/brain to coronal face (nose/lips) in 42.7%; abdomen to thorax/heart in 26.1%; and three-dimensional/four-dimensional face to sagittal face (profile) in 23.7%. Transitions between three or more consecutive structures in sequence were uncommon (up to 13% of scans). None of the captured anomaly scans shared an entirely identical sequence. CONCLUSIONS: We present a novel evaluation of the anomaly scan acquisition process using a deep-learning-based analysis of ultrasound video. We note wide variation in the number and sequence of structures obtained during routine second-trimester anomaly scans. Overall, each anomaly scan was found to be unique in its scanning sequence, suggesting that sonographers take advantage of the fetal position and acquire the standard planes according to their visibility rather than following a strict acquisition order. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Aprendizado Profundo , Feminino , Gravidez , Humanos , Fluxo de Trabalho , Ultrassonografia Pré-Natal/métodos , Segundo Trimestre da Gravidez , Feto/anatomia & histologia
7.
PLoS Med ; 18(4): e1003611, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33905424

RESUMO

BACKGROUND: Gestational hypertensive and acute hypotensive disorders are associated with maternal morbidity and mortality worldwide. However, physiological blood pressure changes in pregnancy are insufficiently defined. We describe blood pressure changes across healthy pregnancies from the International Fetal and Newborn Growth Consortium for the 21st Century (INTERGROWTH-21st) Fetal Growth Longitudinal Study (FGLS) to produce international, gestational age-specific, smoothed centiles (third, 10th, 50th, 90th, and 97th) for blood pressure. METHODS AND FINDINGS: Secondary analysis of a prospective, longitudinal, observational cohort study (2009 to 2016) was conducted across 8 diverse urban areas in Brazil, China, India, Italy, Kenya, Oman, the United Kingdom, and the United States of America. We enrolled healthy women at low risk of pregnancy complications. We measured blood pressure using standardised methodology and validated equipment at enrolment at <14 weeks, then every 5 ± 1 weeks until delivery. We enrolled 4,607 (35%) women of 13,108 screened. The mean maternal age was 28·4 (standard deviation [SD] 3.9) years; 97% (4,204/4,321) of women were married or living with a partner, and 68% (2,955/4,321) were nulliparous. Their mean body mass index (BMI) was 23.3 (SD 3.0) kg/m2. Systolic blood pressure was lowest at 12 weeks: Median was 111.5 (95% CI 111.3 to 111.8) mmHg, rising to a median maximum of 119.6 (95% CI 118.9 to 120.3) mmHg at 40 weeks' gestation, a difference of 8.1 (95% CI 7.4 to 8.8) mmHg. Median diastolic blood pressure decreased from 12 weeks: 69.1 (95% CI 68.9 to 69.3) mmHg to a minimum of 68.5 (95% CI 68.3 to 68.7) mmHg at 19+5 weeks' gestation, a change of -0·6 (95% CI -0.8 to -0.4) mmHg. Diastolic blood pressure subsequently increased to a maximum of 76.3 (95% CI 75.9 to 76.8) mmHg at 40 weeks' gestation. Systolic blood pressure fell by >14 mmHg or diastolic blood pressure by >11 mmHg in fewer than 10% of women at any gestational age. Fewer than 10% of women increased their systolic blood pressure by >24 mmHg or diastolic blood pressure by >18 mmHg at any gestational age. The study's main limitations were the unavailability of prepregnancy blood pressure values and inability to explore circadian effects because time of day was not recorded for the blood pressure measurements. CONCLUSIONS: Our findings provide international, gestational age-specific centiles and limits of acceptable change to facilitate earlier recognition of deteriorating health in pregnant women. These centiles challenge the idea of a clinically significant midpregnancy drop in blood pressure.


Assuntos
Pressão Sanguínea/fisiologia , Desenvolvimento Fetal/fisiologia , Idade Gestacional , Adulto , Brasil , Pré-Escolar , China , Feminino , Humanos , Índia , Itália , Quênia , Estudos Longitudinais , Ultrassonografia Pré-Natal/métodos , Reino Unido , Adulto Jovem
8.
Am J Obstet Gynecol ; 224(2): 208.e1-208.e18, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32768431

RESUMO

BACKGROUND: Human growth is susceptible to damage from insults, particularly during periods of rapid growth. Identifying those periods and the normative limits that are compatible with adequate growth and development are the first key steps toward preventing impaired growth. OBJECTIVE: This study aimed to construct international fetal growth velocity increment and conditional velocity standards from 14 to 40 weeks' gestation based on the same cohort that contributed to the INTERGROWTH-21st Fetal Growth Standards. STUDY DESIGN: This study was a prospective, longitudinal study of 4321 low-risk pregnancies from 8 geographically diverse populations in the INTERGROWTH-21st Project with rigorous standardization of all study procedures, equipment, and measurements that were performed by trained ultrasonographers. Gestational age was accurately determined clinically and confirmed by ultrasound measurement of crown-rump length at <14 weeks' gestation. Thereafter, the ultrasonographers, who were masked to the values, measured the fetal head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length in triplicate every 5 weeks (within 1 week either side) using identical ultrasound equipment at each site (4-7 scans per pregnancy). Velocity increments across a range of intervals between measures were modeled using fractional polynomial regression. RESULTS: Peak velocity was observed at a similar gestational age: 16 and 17 weeks' gestation for head circumference (12.2 mm/wk), and 16 weeks' gestation for abdominal circumference (11.8 mm/wk) and femur length (3.2 mm/wk). However, velocity growth slowed down rapidly for head circumference, biparietal diameter, occipitofrontal diameter, and femur length, with an almost linear reduction toward term that was more marked for femur length. Conversely, abdominal circumference velocity remained relatively steady throughout pregnancy. The change in velocity with gestational age was more evident for head circumference, biparietal diameter, occipitofrontal diameter, and femur length than for abdominal circumference when the change was expressed as a percentage of fetal size at 40 weeks' gestation. We have also shown how to obtain accurate conditional fetal velocity based on our previous methodological work. CONCLUSION: The fetal skeleton and abdomen have different velocity growth patterns during intrauterine life. Accordingly, we have produced international Fetal Growth Velocity Increment Standards to complement the INTERGROWTH-21st Fetal Growth Standards so as to monitor fetal well-being comprehensively worldwide. Fetal growth velocity curves may be valuable if one wants to study the pathophysiology of fetal growth. We provide an application that can be used easily in clinical practice to evaluate changes in fetal size as conditional velocity for a more refined assessment of fetal growth than is possible at present (https://lxiao5.shinyapps.io/fetal_growth/). The application is freely available with the other INTERGROWTH-21st tools at https://intergrowth21.tghn.org/standards-tools/.


Assuntos
Abdome/embriologia , Fêmur/embriologia , Desenvolvimento Fetal , Idade Gestacional , Cabeça/embriologia , Abdome/diagnóstico por imagem , Adulto , Estatura Cabeça-Cóccix , Feminino , Fêmur/diagnóstico por imagem , Gráficos de Crescimento , Cabeça/diagnóstico por imagem , Humanos , Recém-Nascido , Internacionalidade , Estudos Longitudinais , Masculino , Gravidez , Ultrassonografia Pré-Natal , Adulto Jovem
9.
Ultrasound Obstet Gynecol ; 57(4): 614-623, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32196791

RESUMO

OBJECTIVE: To construct international ultrasound-based standards for fetal cerebellar growth and Sylvian fissure maturation. METHODS: Healthy, well nourished pregnant women, enrolled at < 14 weeks' gestation in the Fetal Growth Longitudinal Study (FGLS) of INTERGROWTH-21st , an international multicenter, population-based project, underwent serial three-dimensional (3D) fetal ultrasound scans every 5 ± 1 weeks until delivery in study sites located in Brazil, India, Italy, Kenya and the UK. In the present analysis, only those fetuses that underwent developmental assessment at 2 years of age were included. We measured the transcerebellar diameter and assessed Sylvian fissure maturation using two-dimensional ultrasound images extracted from available 3D fetal head volumes. The appropriateness of pooling data from the five sites was assessed using variance component analysis and standardized site differences. For each Sylvian fissure maturation score (left or right side), mean gestational age and 95% CI were calculated. Transcerebellar diameter was modeled using fractional polynomial regression, and goodness of fit was assessed. RESULTS: Of those children in the original FGLS cohort who had developmental assessment at 2 years of age, 1130 also had an available 3D ultrasound fetal head volume. The sociodemographic characteristics and pregnancy/perinatal outcomes of the study sample confirmed the health and low-risk status of the population studied. In addition, the fetuses had low morbidity and adequate growth and development at 2 years of age. In total, 3016 and 2359 individual volumes were available for transcerebellar-diameter and Sylvian-fissure analysis, respectively. Variance component analysis and standardized site differences showed that the five study populations were sufficiently similar on the basis of predefined criteria for the data to be pooled to produce international standards. A second-degree fractional polynomial provided the best fit for modeling transcerebellar diameter; we then estimated gestational-age-specific 3rd , 50th and 97th smoothed centiles. Goodness-of-fit analysis comparing empirical centiles with smoothed centile curves showed good agreement. The Sylvian fissure increased in maturation with advancing gestation, with complete overlap of the mean gestational age and 95% CIs between the sexes for each development score. No differences in Sylvian fissure maturation between the right and left hemispheres were observed. CONCLUSION: We present, for the first time, international standards for fetal cerebellar growth and Sylvian fissure maturation throughout pregnancy based on a healthy fetal population that exhibited adequate growth and development at 2 years of age. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Cerebelo/embriologia , Aqueduto do Mesencéfalo/embriologia , Desenvolvimento Fetal , Gráficos de Crescimento , Ultrassonografia Pré-Natal , Adulto , Brasil , Cerebelo/crescimento & desenvolvimento , Aqueduto do Mesencéfalo/crescimento & desenvolvimento , Pré-Escolar , Feminino , Idade Gestacional , Humanos , Índia , Lactente , Recém-Nascido , Itália , Quênia , Estudos Longitudinais , Masculino , Gravidez , Resultado da Gravidez , Padrões de Referência , Reino Unido
10.
Ultrasound Obstet Gynecol ; 56(4): 498-505, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32530098

RESUMO

Artificial intelligence (AI) uses data and algorithms to aim to draw conclusions that are as good as, or even better than, those drawn by humans. AI is already part of our daily life; it is behind face recognition technology, speech recognition in virtual assistants (such as Amazon Alexa, Apple's Siri, Google Assistant and Microsoft Cortana) and self-driving cars. AI software has been able to beat world champions in chess, Go and recently even Poker. Relevant to our community, it is a prominent source of innovation in healthcare, already helping to develop new drugs, support clinical decisions and provide quality assurance in radiology. The list of medical image-analysis AI applications with USA Food and Drug Administration or European Union (soon to fall under European Union Medical Device Regulation) approval is growing rapidly and covers diverse clinical needs, such as detection of arrhythmia using a smartwatch or automatic triage of critical imaging studies to the top of the radiologist's worklist. Deep learning, a leading tool of AI, performs particularly well in image pattern recognition and, therefore, can be of great benefit to doctors who rely heavily on images, such as sonologists, radiographers and pathologists. Although obstetric and gynecological ultrasound are two of the most commonly performed imaging studies, AI has had little impact on this field so far. Nevertheless, there is huge potential for AI to assist in repetitive ultrasound tasks, such as automatically identifying good-quality acquisitions and providing instant quality assurance. For this potential to thrive, interdisciplinary communication between AI developers and ultrasound professionals is necessary. In this article, we explore the fundamentals of medical imaging AI, from theory to applicability, and introduce some key terms to medical professionals in the field of ultrasound. We believe that wider knowledge of AI will help accelerate its integration into healthcare. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Inteligência Artificial/tendências , Ginecologia/tendências , Obstetrícia/tendências , Ultrassonografia/tendências , Feminino , Humanos , Gravidez
11.
Ultrasound Obstet Gynecol ; 55(3): 375-382, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31763735

RESUMO

OBJECTIVES: Operators performing fetal growth scans are usually aware of the gestational age of the pregnancy, which may lead to expected-value bias when performing biometric measurements. We aimed to evaluate the incidence of expected-value bias in routine fetal growth scans and assess its impact on standard biometric measurements. METHODS: We collected prospectively full-length video recordings of routine ultrasound growth scans coupled with operator eye tracking. Expected value was defined as the gestational age at the time of the scan, based on the estimated due date that was established at the dating scan. Expected-value bias was defined as occurring when the operator looked at the measurement box on the screen during the process of caliper adjustment before saving a measurement. We studied the three standard biometric planes on which measurements of head circumference (HC), abdominal circumference (AC) and femur length (FL) are obtained. We evaluated the incidence of expected-value bias and quantified the impact of biased measurements. RESULTS: We analyzed 272 third-trimester growth scans, performed by 16 operators, during which a total of 1409 measurements (354 HC, 703 AC and 352 FL; including repeat measurements) were obtained. Expected-value bias occurred in 91.4% of the saved standard biometric plane measurements (85.0% for HC, 92.9% for AC and 94.9% for FL). The operators were more likely to adjust the measurements towards the expected value than away from it (47.7% vs 19.7% of measurements; P < 0.001). On average, measurements were corrected by 2.3 ± 5.6, 2.4 ± 10.4 and 3.2 ± 10.4 days of gestation towards the expected gestational age for the HC, AC, and FL measurements, respectively. Additionally, we noted a statistically significant reduction in measurement variance once the operator was biased (P = 0.026). Comparing the lowest and highest possible estimated fetal weight (using the smallest and largest biased HC, AC and FL measurements), we noted that the discordance, in percentage terms, was 10.1% ± 6.5%, and that in 17% (95% CI, 12-21%) of the scans, the fetus could be considered as small-for-gestational age or appropriate-for-gestational age if using the smallest or largest possible measurements, respectively. Similarly, in 13% (95% CI, 9-16%) of scans, the fetus could be considered as large-for-gestational age or appropriate-for-gestational age if using the largest or smallest possible measurements, respectively. CONCLUSIONS: During routine third-trimester growth scans, expected-value bias frequently occurs and significantly changes standard biometric measurements obtained. © 2019 the Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Biometria/métodos , Desenvolvimento Fetal , Feto/diagnóstico por imagem , Variações Dependentes do Observador , Ultrassonografia Pré-Natal/estatística & dados numéricos , Abdome/diagnóstico por imagem , Abdome/embriologia , Feminino , Fêmur/diagnóstico por imagem , Fêmur/embriologia , Feto/embriologia , Idade Gestacional , Cabeça/diagnóstico por imagem , Cabeça/embriologia , Humanos , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Ultrassonografia Pré-Natal/métodos , Gravação em Vídeo
12.
Ultrasound Obstet Gynecol ; 56(3): 359-370, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32048426

RESUMO

OBJECTIVE: To create prescriptive growth standards for five fetal brain structures, measured using ultrasound, in healthy, well-nourished women at low risk of impaired fetal growth and poor perinatal outcome, taking part in the Fetal Growth Longitudinal Study (FGLS) of the INTERGROWTH-21st Project. METHODS: This was a complementary analysis of a large, population-based, multicenter, longitudinal study. The sample analyzed was selected randomly from the overall FGLS population, ensuring an equal distribution among the eight diverse participating sites and of three-dimensional (3D) ultrasound volumes across pregnancy (range: 15-36 weeks' gestation). We measured, in planes reconstructed from 3D ultrasound volumes of the fetal head at different timepoints in pregnancy, the size of the parieto-occipital fissure (POF), Sylvian fissure (SF), anterior horn of the lateral ventricle, atrium of the posterior horn of the lateral ventricle (PV) and cisterna magna (CM). Fractional polynomials were used to construct the standards. Growth and development of the infants were assessed at 1 and 2 years of age to confirm their adequacy for constructing international standards. RESULTS: From the entire FGLS cohort of 4321 women, 451 (10.4%) were selected at random. After exclusions, 3D ultrasound volumes from 442 fetuses born without a congenital malformation were used to create the charts. The fetal brain structures of interest were identified in 90% of cases. All structures, except the PV, showed increasing size with gestational age, and the size of the POF, SF, PV and CM showed increasing variability. The 3rd , 5th , 50th , 95th and 97th smoothed centiles are presented. The 5th centiles for the POF and SF were 3.1 mm and 4.7 mm at 22 weeks' gestation and 4.6 mm and 9.9 mm at 32 weeks, respectively. The 95th centiles for the PV and CM were 8.5 mm and 7.5 mm at 22 weeks and 8.6 mm and 9.5 mm at 32 weeks, respectively. CONCLUSIONS: We have produced prescriptive size standards for fetal brain structures based on prospectively enrolled pregnancies at low risk of abnormal outcome. We recommend these as international standards for the assessment of measurements obtained using ultrasound from fetal brain structures. © 2020 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Encéfalo/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Encéfalo/crescimento & desenvolvimento , Cefalometria , Feminino , Desenvolvimento Fetal , Idade Gestacional , Saúde Global , Humanos , Estudos Longitudinais , Gravidez , Valores de Referência
13.
Ultraschall Med ; 41(2): 138-145, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32107757

RESUMO

PURPOSE: To analyze bioeffect safety indices and assess how often operators look at these indices during routine obstetric ultrasound. MATERIALS AND METHODS: Automated analysis of prospectively collected data including video recordings of full-length ultrasound scans coupled with operator eye tracking was performed. Using optical recognition, we extracted the Mechanical Index (MI), Thermal Index in soft tissue (TIs), and Thermal Index in bone (TIb) values and ultrasound mode. This allowed us to report the bioeffect safety indices during routine obstetric scans and assess adherence to professional organization recommendations. Eye-tracking analysis allowed us to assess how often operators look at the displayed bioeffect safety indices. RESULTS: A total of 637 ultrasound scans performed by 17 operators were included, of which 178, 216, and 243 scans were first, second, and third-trimester scans, respectively. During live scanning, the mean and range were 0.14 (0.1 to 3.0) for TIb, 0.2 (0.1 to 1.2) for TIs, and 0.9 (0.1 to 1.3) for MI. The mean and standard deviation of TIb were 0.15 ±â€Š0.03, 0.23 ±â€Š0.09, 0.32 ±â€Š0.24 in the first, second, and third trimester, respectively. For B-mode, the highest TIb was 0.8 in all trimesters. The highest TIb was recorded for pulsed-wave Doppler mode in all trimesters. The recommended exposure times were maintained in all scans. Analysis of eye tracking suggested that operators looked at bioeffect safety indices in only 27 (4.2 %) of the scans. CONCLUSION: In this study, recommended bioeffect indices were adhered to in all routine scans. However, eye tracking showed that operators rarely assessed safety indices during scanning.


Assuntos
Segurança do Paciente , Ultrassonografia Pré-Natal , Feminino , Humanos , Gravidez , Ultrassonografia
14.
Radiology ; 290(3): 640-648, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30561279

RESUMO

Purpose To evaluate myocardial strain and circumferential transmural strain difference (cTSD; the difference between epicardial and endocardial circumferential strain) in a genotyped cohort with hypertrophic cardiomyopathy (HCM) and to explore correlations between cTSD and other anatomic and functional markers of disease status. Left ventricular (LV) dysfunction may indicate early disease in preclinical HCM (sarcomere mutation carriers without LV hypertrophy). Cardiac MRI feature tracking may be used to evaluate myocardial strain in carriers of HCM sarcomere mutation. Materials and Methods Participants with HCM and their family members participated in a prospective, multicenter, observational study (HCMNet). Genetic testing was performed in all participants. Study participants underwent cardiac MRI with temporal resolution at 40 msec or less. LV myocardial strain was analyzed by using feature-tracking software. Circumferential strain was measured at the epicardial and endocardial surfaces; their difference yielded the circumferential transmural strain difference (cTSD). Multivariable analysis to predict HCM status was performed by using multinomial logistic regression adjusting for age, sex, and LV parameters. Results Ninety-nine participants were evaluated (23 control participants, 34 participants with preclinical HCM [positive for sarcomere mutation and negative for LV hypertrophy], and 42 participants with overt HCM [positive for sarcomere mutation and negative for LV hypertrophy]). The average age was 25 years ± 11 and 44 participants (44%) were women. Maximal LV wall thickness was 9.5 mm ± 1.4, 9.8 mm ± 2.2, and 16.1 mm ± 5.3 in control participants, participants with preclinical HCM (P = .496 vs control participants), and participants with overt HCM (P < .001 vs control participants), respectively. cTSD for control participants, preclinical HCM, and overt HCM was 14% ± 4, 17% ± 4, and 22% ± 7, respectively (P < .01 for all comparisons). In multivariable models (controlling for septal thickness and log-transformed N-terminal brain-type natriuretic peptide), cTSD was predictive of preclinical and overt HCM disease status (P < .01). Conclusion Cardiac MRI feature tracking identifies myocardial dysfunction not only in participants with overt hypertrophic cardiomyopathy, but also in carriers of sarcomere mutation without left ventricular hypertrophy, suggesting that contractile abnormalities are present even when left ventricular wall thickness is normal. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/genética , Imagem Cinética por Ressonância Magnética , Mutação/genética , Sarcômeros/genética , Disfunção Ventricular Esquerda/genética , Adulto , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos Transversais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Estudos Prospectivos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
15.
Faraday Discuss ; 218(0): 115-137, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31123727

RESUMO

The intricate chemistry of the carbonaceous particle surface layer (which drives their reactivity, environmental and health impacts) results in complex mass spectra. In this respect, detailed molecular-level analysis of combustion emissions may be challenging even with high-resolution mass spectrometry. Building on a recently proposed comprehensive methodology (encompassing all stages from sampling to data reduction), we propose herein a comparative analysis of soot particles produced by three different sources: a miniCAST standard generator, a laboratory diffusion flame and a single cylinder internal combustion engine. The surface composition is probed by either laser or secondary ion mass spectrometry. Two examples of multivariate analysis, Principal component analysis and hierarchical clustering analysis proved their efficiency in both identifying general trends and evidencing subtle differences that otherwise would remain unnoticed in the plethora of data generated during mass spectrometric analyses. Chemical information extracted from these multivariate statistical procedures contributes to a better understanding of fundamental combustion processes and also opens to practical applications such as the tracing of engine emissions.

16.
Ultrasound Obstet Gynecol ; 54(2): 239-245, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30302849

RESUMO

OBJECTIVE: A large-scale audit and peer review of ultrasound images may improve sonographer performance, but is rarely performed consistently as it is time-consuming and expensive. The aim of this study was to perform a large-scale audit of routine fetal anatomy scans to assess if a full clinical audit cycle can improve clinical image-acquisition standards. METHODS: A large-scale, clinical, retrospective audit was conducted of ultrasound images obtained during all routine anomaly scans performed from 18 + 0 to 22 + 6 weeks' gestation at a UK hospital during 2013 (Cycle 1), to build a baseline understanding of the performance of sonographers. Targeted actions were undertaken in response to the findings with the aim of improving departmental performance. A second full-year audit was then performed of fetal anatomy ultrasound images obtained during the following year (Cycle 2). An independent pool of experienced sonographers used an online tool to assess all scans in terms of two parameters: scan completeness (i.e. were all images archived?) and image quality using objective scoring (i.e. were images of high quality?). Both were assessed in each audit at the departmental level and at the individual sonographer level. A random sample of 10% of scans was used to assess interobserver reproducibility. RESULTS: In Cycle 1 of the audit, 103 501 ultrasound images from 6257 anomaly examinations performed by 22 sonographers were assessed; in Cycle 2, 153 557 images from 6406 scans performed by 25 sonographers were evaluated. The analysis was performed including the images obtained by the 20 sonographers who participated in both cycles. Departmental median scan completeness improved from 72% in the first year to 78% at the second assessment (P < 0.001); median image-quality score for all fetal views improved from 0.83 to 0.86 (P < 0.001). The improvement was greatest for those sonographers who performed poorest in the first audit; with regards to scan completeness, the poorest performing 15% of sonographers in Cycle 1 improved by more than 30 percentage points, and with regards to image quality, the poorest performing 11% in Cycle 1 showed a more than 10% improvement. Interobserver repeatability of scan completeness and image-quality scores across different fetal views were similar to those in the published literature. CONCLUSIONS: A clinical audit and a set of targeted actions helped improve sonographer scan-acquisition completeness and scan quality. Such adherence to recommended clinical acquisition standards may increase the likelihood of correct measurement and thereby fetal growth assessment, and should allow better detection of abnormalities. As such a large-scale audit is time consuming, further advantages would be achieved if this process could be automated. © 2018 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Auditoria Clínica/métodos , Feto/diagnóstico por imagem , Programas de Rastreamento/normas , Ultrassonografia Pré-Natal/métodos , Competência Clínica/normas , Competência Clínica/estatística & dados numéricos , Feminino , Desenvolvimento Fetal/fisiologia , Feto/anatomia & histologia , Idade Gestacional , Humanos , Variações Dependentes do Observador , Gravidez , Melhoria de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Reino Unido/epidemiologia
18.
J Theor Biol ; 437: 163-178, 2018 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-29080780

RESUMO

Whereas penile vaginal intercourse (VI) is thought to be the dominant mode of HIV transmission in sub-Saharan Africa, cross-sectional studies in the region indicate the preponderance of heterosexual anal intercourse (AI) among high activity groups. A dynamic, heterosexual core group model with risk of infection through both vaginal and anal pathways is formulated and comprehensively analysed. The model is coupled to a general population model and fitted to HIV prevalence data for Zimbabwe in order to explore the parameter space related to heterosexual AI. The model fit supports a core group size ranging between 5-20% and exposure risk to AI in excess of 50%. The control effort quantified by the reproductive number (RA) at commencement of the epidemic corresponds to R0=4.40. With the contribution of heterosexual AI to Zimbabwe's (and that of the sub-Saharan African region) epidemic unknown, the study apportioned infections between the two infection pathways. New infections due to VI ranged from 2-4.5% and 0.5-2.7% from heterosexual AI. The study estimates infection probabilities ranging from 0.15 to 0.35 for both receptive and infective AI. By quantifying the incidence due to VI and AI risks, we put emphasis on the necessity for targeted interventions. To project the potential impact of heterosexual AI in high HIV prevalence settings, we raised the core group size to 20% in the year 2010 coinciding with reported heterosexual AI prevalence outside of Africa and allowed the proportion of infection risk associated with AI to vary. Prevalence and incidence projections were made up to the year 2020 starting from a baseline value of zero exposure to AI transmission risk per sex act, progressively increasing exposure to 50% and 70% respectively. A 50% exposure to AI would result in HIV prevalence scaling up by 23% from the baseline values in year 2020. Increasing exposure to 70% was projected to increase HIV prevalence by 38% in year 2020. The HIV infection risks associated with AI are recognised and inform HIV policy for men who have sex with men, yet the same risks are ignored in HIV intervention programmes for heterosexuals. This study highlights the potential danger of increasing prevalence of heterosexual AI in settings with high HIV prevalence. Evolving and globally cross pollinating sexual behaviors compel for dovetailing HIV policy making with sexology.


Assuntos
Algoritmos , Infecções por HIV/transmissão , Heterossexualidade/estatística & dados numéricos , Modelos Teóricos , Comportamento Sexual/estatística & dados numéricos , Adulto , África Subsaariana/epidemiologia , Estudos Transversais , Epidemias , Feminino , Infecções por HIV/epidemiologia , Humanos , Masculino , Prevalência , Fatores de Risco , Zimbábue/epidemiologia
19.
BJOG ; 125(9): 1145-1153, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28029221

RESUMO

OBJECTIVES: To identify risk factors for antepartum stillbirth, including fetal growth restriction, among women with well-dated pregnancies and access to antenatal care. DESIGN: Population-based, prospective, observational study. SETTING: Eight international urban populations. POPULATION: Pregnant women and their babies enrolled in the Newborn Cross-Sectional Study of the INTERGROWTH-21st Project. METHODS: Cox proportional hazard models were used to compare risks among antepartum stillborn and liveborn babies. MAIN OUTCOME MEASURES: Antepartum stillbirth was defined as any fetal death after 16 weeks' gestation before the onset of labour. RESULTS: Of 60 121 babies, 553 were stillborn (9.2 per 1000 births), of which 445 were antepartum deaths (7.4 per 1000 births). After adjustment for site, risk factors were low socio-economic status, hazard ratio (HR): 1.6 (95% CI, 1.2-2.1); single marital status, HR 2.0 (95% CI, 1.4-2.8); age ≥40 years, HR 2.2 (95% CI, 1.4-3.7); essential hypertension, HR 4.0 (95% CI, 2.7-5.9); HIV/AIDS, HR 4.3 (95% CI, 2.0-9.1); pre-eclampsia, HR 1.6 (95% CI, 1.1-3.8); multiple pregnancy, HR 3.3 (95% CI, 2.0-5.6); and antepartum haemorrhage, HR 3.3 (95% CI, 2.5-4.5). Birth weight <3rd centile was associated with antepartum stillbirth [HR, 4.6 (95% CI, 3.4-6.2)]. The greatest risk was seen in babies not suspected to have been growth restricted antenatally, with an HR of 5.0 (95% CI, 3.6-7.0). The population-attributable risk of antepartum death associated with small-for-gestational-age neonates diagnosed at birth was 11%. CONCLUSIONS: Antepartum stillbirth is a complex syndrome associated with several risk factors. Although small babies are at higher risk, current growth restriction detection strategies only modestly reduced the rate of stillbirth. TWEETABLE ABSTRACT: International stillbirth study finds individual risks poor predictors of death but combinations promising.


Assuntos
Natimorto/epidemiologia , Estudos Transversais , Feminino , Retardo do Crescimento Fetal/epidemiologia , Retardo do Crescimento Fetal/etiologia , Peso Fetal , Idade Gestacional , Humanos , Recém-Nascido , Gravidez , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Síndrome
20.
Ultrasound Obstet Gynecol ; 52(3): 332-339, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28718938

RESUMO

OBJECTIVE: To assess a comprehensive package of ultrasound quality control in the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project, a large multicenter study of fetal growth. METHODS: Quality control (QC) measures were performed for 20 313 ultrasound scan images obtained prospectively from 4321 fetuses at 14-41 weeks' gestation in eight geographical locations. At the time of each ultrasound examination, three fetal biometric variables (head circumference (HC), abdominal circumference (AC) and femur length (FL)) were measured in triplicate on separately generated images. All measurements were taken in a blinded fashion. QC had two elements: (1) qualitative QC: visual assessment by sonographers at each study site of their images based on specific criteria, with 10% of images being re-assessed at the Oxford-based Ultrasound Quality Unit (compared using an adjusted kappa statistic); and (2) quantitative QC: assessment of measurement data by comparing the first, second and third measurements (intraobserver variability), remeasurement of caliper replacement in 10% (interobserver variability), both by Bland-Altman plots and plotting frequency histograms of the SD of triplicate measurements and assessing how many were above or below 2 SD of the expected distribution. The system allowed the sonographers' performances to be monitored regularly. RESULTS: A high level of agreement between self- and external scoring was demonstrated for all measurements (κ = 0.99 (95% CI, 0.98-0.99) for HC, 0.98 (95% CI, 0.97-0.99) for AC and 0.96 (95% CI, 0.95-0.98) for FL). Intraobserver 95% limits of agreement (LoA) of ultrasound measures for HC, AC and FL were ± 3.3%, ± 5.6% and ± 6.2%, respectively; the corresponding values for interobserver LoA were ± 4.4%, ± 6.0% and ± 5.6%. The SD distribution of triplicate measurements for all biometric variables showed excessive variability for three of 31 sonographers, allowing prompt identification and retraining. CONCLUSIONS: Qualitative and quantitative QC monitoring was feasible and highly reproducible in a large multicenter research study, which facilitated the production of high-quality ultrasound images. We recommend that the QC system we developed is implemented in future research studies and clinical practice. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Desenvolvimento Fetal , Variações Dependentes do Observador , Controle de Qualidade , Ultrassonografia Pré-Natal/normas , Abdome/diagnóstico por imagem , Abdome/embriologia , Biometria/métodos , Estudos de Viabilidade , Feminino , Fêmur/diagnóstico por imagem , Fêmur/embriologia , Cabeça/diagnóstico por imagem , Cabeça/embriologia , Humanos , Vigilância da População , Gravidez , Estudos Prospectivos , Circunferência da Cintura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA