Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Biol Chem ; 298(6): 102019, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35533728

RESUMO

Arp2/3 complex nucleates branched actin filaments that drive processes like endocytosis and lamellipodial protrusion. WISH/DIP/SPIN90 (WDS) proteins form a class of Arp2/3 complex activators or nucleation promoting factors (NPFs) that, unlike WASP family NPFs, activate Arp2/3 complex without requiring preformed actin filaments. Therefore, activation of Arp2/3 complex by WDS proteins is thought to produce the initial actin filaments that seed branching nucleation by WASP-bound Arp2/3 complexes. However, whether activation of Arp2/3 complex by WDS proteins is important for the initiation of branched actin assembly in cells has not been directly tested. Here, we used structure-based point mutations of the Schizosaccharomyces pombe WDS protein Dip1 to test the importance of its Arp2/3-activating activity in cells. Six of thirteen Dip1 mutants caused severe defects in Arp2/3 complex activation in vitro, and we found a strong correlation between the ability of mutants to activate Arp2/3 complex and to rescue endocytic actin assembly defects caused by deleting Dip1. These data support a model in which Dip1 activates Arp2/3 complex to produce actin filaments that initiate branched actin assembly at endocytic sites. Dip1 mutants that synergized with WASP in activating Arp2/3 complex in vitro showed milder defects in cells compared to those that did not, suggesting that in cells the two NPFs may coactivate Arp2/3 complex to initiate actin assembly. Finally, the mutational data reveal important complementary electrostatic contacts at the Dip1-Arp2/3 complex interface and corroborate the previously proposed wedge model, which describes how Dip1 binding triggers structural changes that activate Arp2/3 complex.


Assuntos
Citoesqueleto de Actina , Complexo 2-3 de Proteínas Relacionadas à Actina , Proteínas de Schizosaccharomyces pombe , Schizosaccharomyces , Citoesqueleto de Actina/metabolismo , Complexo 2-3 de Proteínas Relacionadas à Actina/genética , Complexo 2-3 de Proteínas Relacionadas à Actina/metabolismo , Actinas/metabolismo , Pseudópodes/metabolismo , Schizosaccharomyces/genética , Schizosaccharomyces/metabolismo , Proteínas de Schizosaccharomyces pombe/genética , Proteínas de Schizosaccharomyces pombe/metabolismo
2.
JAMA Otolaryngol Head Neck Surg ; 150(2): 165-171, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38127360

RESUMO

Importance: Transoral robot-assisted surgery (TORS) continues to have a major role in the treatment of oropharyngeal cancer. As new iterations of robotic technology are increasingly utilized, it is important to share learning experiences and clinical outcomes data, to optimize technical efficiency and clinical care. Observations: This was a retrospective review of a large academic institution's initial clinical use of the da Vinci Single Port (SP) compared with the da Vinci Si (Si) system. A total of 205 TORS cases were reviewed: 109 in the SP group (November 22, 2018, through September 30, 2020), and 96 in the Si group (January 1, 2016, through November 12, 2018). Both groups had comparable operative times, rates of postoperative pharyngeal hemorrhage, length of hospital stay, and duration of nasogastric feeding tube use. There was no difference in pathological characteristics, rates of positive margins, or indications for or time to initiation of adjuvant therapy between the groups. The collective experience of 6 faculty members-who have trained 139 TORS surgeons for the SP system rollout-was compiled to provide a summary of learning experiences and technical notes on safe and efficient operation of the SP system. Conclusions and Relevance: This Review found that the functional and oncologic outcomes were comparable between TORS cases performed with the Si and SP systems, and they had similar complication rates. Recognized advantages of the SP over the Si system include the availability of bipolar-energized instruments, a usable third surgical arm, and improved camera image quality.


Assuntos
Neoplasias Orofaríngeas , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias Orofaríngeas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
Nat Commun ; 10(1): 5044, 2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31695030

RESUMO

Identification of lymph node (LN) metastasis is essential for staging of solid tumors, and as a result, surgeons focus on harvesting significant numbers of LNs during ablative procedures for pathological evaluation. Isolating those LNs most likely to harbor metastatic disease can allow for a more rigorous evaluation of fewer LNs. Here we evaluate the impact of a systemically injected, near-infrared fluorescently-labeled, tumor-targeting contrast agent, panitumumab-IRDye800CW, to facilitate the identification of metastatic LNs in the ex vivo setting for head and neck cancer patients. Molecular imaging demonstrates a significantly higher mean fluorescence signal in metastatic LNs compared to benign LNs in head and neck cancer patients undergoing an elective neck dissection. Molecular imaging to preselect at-risk LNs may thus allow a more rigorous examination of LNs and subsequently lead to improved prognostication than regular neck dissection.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/diagnóstico por imagem , Imagem Molecular/métodos , Imagem Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Corantes Fluorescentes , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Linfonodos/cirurgia , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Coloração e Rotulagem
4.
Theranostics ; 8(9): 2488-2495, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29721094

RESUMO

Purpose: To demonstrate the safety and feasibility of leveraging therapeutic antibodies for surgical imaging. Procedures: We conducted two phase I trials for anti-epidermal growth factor receptor antibodies cetuximab-IRDye800CW (n=12) and panitumumab-IRDye800CW (n=15). Adults with biopsy-confirmed head and neck squamous cell carcinoma scheduled for standard-of-care surgery were eligible. For cetuximab-IRDye800CW, cohort 1 was intravenously infused with 2.5 mg/m2, cohort 2 received 25 mg/m2, and cohort 3 received 62.5 mg/m2. For panitumumab-IRDye800CW, cohorts received 0.06 mg/kg, 0.5 mg/kg, and 1 mg/kg, respectively. Electrocardiograms and blood samples were obtained, and patients were followed for 30 days post-study drug infusion. Results: Both fluorescently labeled antibodies had similar pharmacodynamic properties and minimal toxicities. Two infusion reactions occurred with cetuximab and none with panitumumab. There were no grade 2 or higher toxicities attributable to cetuximab-IRDye800CW or panitumumab-IRDye800CW; fifteen grade 1 adverse events occurred with cetuximab-IRDye800CW, and one grade 1 occurred with panitumumab-IRDye800CW. There were no significant differences in QTc prolongation between the two trials (p=0.8). Conclusions: Panitumumab-IRDye800CW and cetuximab-IRDye800CW have toxicity and pharmacodynamic profiles that match the parent compound, suggesting that other therapeutic antibodies may be repurposed as imaging agents with limited preclinical toxicology data.


Assuntos
Antineoplásicos Imunológicos/efeitos adversos , Benzenossulfonatos/efeitos adversos , Cetuximab/efeitos adversos , Neoplasias de Cabeça e Pescoço/cirurgia , Indóis/efeitos adversos , Panitumumabe/efeitos adversos , Idoso , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/efeitos adversos , Antineoplásicos Imunológicos/administração & dosagem , Benzenossulfonatos/administração & dosagem , Cetuximab/administração & dosagem , Receptores ErbB/metabolismo , Feminino , Fluorescência , Imunofluorescência/métodos , Neoplasias de Cabeça e Pescoço/metabolismo , Humanos , Indóis/administração & dosagem , Masculino , Pessoa de Meia-Idade , Panitumumabe/administração & dosagem
5.
Cancer Res ; 78(17): 5144-5154, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29967260

RESUMO

For many solid tumors, surgical resection remains the gold standard and tumor-involved margins are associated with poor clinical outcomes. Near-infrared (NIR) fluorescence imaging using molecular agents has shown promise for in situ imaging during resection. However, for cancers with difficult imaging conditions, surgical value may lie in tumor mapping of surgical specimens. We thus evaluated a novel approach for real-time, intraoperative tumor margin assessment. Twenty-one adult patients with biopsy-confirmed squamous cell carcinoma arising from the head and neck (HNSCC) scheduled for standard-of-care surgery were enrolled. Cohort 1 (n = 3) received panitumumab-IRDye800CW at an intravenous microdose of 0.06 mg/kg, cohort 2A (n = 5) received 0.5 mg/kg, cohort 2B (n = 7) received 1 mg/kg, and cohort 3 (n = 6) received 50 mg. Patients were followed 30 days postinfusion and adverse events were recorded. Imaging was performed using several closed- and wide-field devices. Fluorescence was histologically correlated to determine sensitivity and specificity. In situ imaging demonstrated tumor-to-background ratio (TBR) of 2 to 3, compared with ex vivo specimen imaging TBR of 5 to 6. We obtained clear differentiation between tumor and normal tissue, with a 3-fold signal difference between positive and negative specimens (P < 0.05). We achieved high correlation of fluorescence intensity with tumor location with sensitivities and specificities >89%; fluorescence predicted distance of tumor tissue to the cut surface of the specimen. This novel method of detecting tumor-involved margins in surgical specimens using a cancer-specific agent provides highly sensitive and specific, real-time, intraoperative surgical navigation in resections with complex anatomy, which are otherwise less amenable to image guidance.Significance: This study demonstrates that fluorescence can be used as a sensitive and specific method of guiding surgeries for head and neck cancers and potentially other cancers with challenging imaging conditions, increasing the probability of complete resections and improving oncologic outcomes. Cancer Res; 78(17); 5144-54. ©2018 AACR.


Assuntos
Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Estudos de Coortes , Receptores ErbB , Feminino , Fluorescência , Regulação Neoplásica da Expressão Gênica , Humanos , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Imagem Óptica/métodos , Panitumumabe/administração & dosagem , Manejo de Espécimes , Carcinoma de Células Escamosas de Cabeça e Pescoço/tratamento farmacológico , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA