Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Jpn J Clin Oncol ; 54(2): 167-174, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-37840362

RESUMO

BACKGROUND: Japanese men receiving apalutamide often experience skin-adverse events (AEs), possibly requiring treatment interruption or dose reduction. However, concerns have arisen regarding the impact of these adjustments on the efficacy of apalutamide. Our study evaluated the efficacy, safety, and persistence of apalutamide in men with metastatic castration-sensitive prostate cancer (mCSPC). METHODS: We retrospectively reviewed the medical records of 108 men with mCSPC from 14 Japanese institutions. The primary outcomes were the efficacy of apalutamide: prostate-specific antigen (PSA) response (50%, 90% and < 0.2 decline) and progression to castration-resistant prostate cancer (CRPC). The secondary outcomes were the skin-AE and compliance of apalutamide. RESULTS: PSA50%, PSA90% and PSA < 0.2 declines were observed in 89.8, 84.3 and 65.7%, and the median time to CRPC progression was not reached. PSA < 0.2 decline and an initial full dose of apalutamide were significantly associated with a longer time to CRPC. The most common AE was skin-AE (50.9%), and there was no association between the occurrence of skin-AE and the time to CRPC (P = 0.72). The median apalutamide persistence was 29 months, which was longer in the initial full dose recipients than in the reduced dose recipients. The dosage is reduced in about 60% of patients within the first year of treatment in the initial full dose recipients. CONCLUSIONS: Our findings indicate the effectiveness of apalutamide in Japanese men with mCSPC, despite a substantial portion requiring dose reduction within a year among the initial full dose recipients.


Assuntos
Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração , Tioidantoínas , Masculino , Humanos , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Japão , Estudos Retrospectivos , Castração
2.
Org Biomol Chem ; 21(6): 1134-1137, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36484376

RESUMO

A mild and efficient approach for the synthesis of thioaurones via NBS-induced cyclization of methoxymethyl-protected mercapto-chalcones has been developed. This simple method is highly functional group tolerant and provides straightforward access to thioaurones in good to high yields.

3.
Int J Urol ; 30(5): 422-430, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36757880

RESUMO

Testosterone plays an important role in maintaining both physical and mental function. Age-related testosterone depletion contributes to the development of angina, arteriosclerosis, obesity, metabolic syndrome, dementia, frailty, and a range of other conditions. A condition involving age-related testosterone depletion and the associated clinical symptoms is defined as late-onset hypogonadism (LOH). LOH is treated by testosterone replacement therapy. Indications for testosterone replacement therapy are determined by evaluating symptoms and signs.


Assuntos
Hipogonadismo , Síndrome Metabólica , Humanos , Hipogonadismo/diagnóstico , Hipogonadismo/tratamento farmacológico , Testosterona/uso terapêutico , Obesidade , Síndrome Metabólica/diagnóstico , Terapia de Reposição Hormonal
4.
J Lipid Res ; 63(12): 100303, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36441023

RESUMO

Glycosphingolipids (GSLs) are composed of a polar glycan chain and a hydrophobic tail known as ceramide. Together with variation in the glycan chain, ceramides exhibit tissue-specific structural variation in the long-chain base (LCB) and N-acyl chain moieties in terms of carbon chain length, degree of desaturation, and hydroxylation. Here, we report the structural variation in GSLs in the urinary bladders of mice and humans. Using TLC, we showed that the major GSLs are hexosylceramide, lactosylceramide, globotriaosylceramide, globotetraosylceramide, Neu5Ac-Gal-Glc-Ceramide, and Neu5Ac-Neu5Ac-Gal-Glc-Ceramide. Our LC-MS analysis indicated that phytoceramide structures with a 20-carbon LCB (4-hydroxyeicosasphinganine) and 2-hydroxy fatty acids are abundant in hexosylceramide and Neu5Ac-Gal-Glc-Ceramide in mice and humans. In addition, quantitative PCR demonstrated that DES2 and FA2H, which are responsible for the generation of 4-hydroxysphinganine and 2-hydroxy fatty acid, respectively, and SPTLC3 and SPTSSB, which are responsible for the generation of 20-carbon LCBs, showed significant expressions in the epithelial layer than in the subepithelial layer. Immunohistochemically, dihydroceramide:sphinganine C4-hydroxylase (DES2) was expressed exclusively in urothelial cells of the urinary bladder. Our findings suggest that these ceramide structures have an impact on membrane properties of the stretching and shrinking in transitional urothelial cells.


Assuntos
Glicoesfingolipídeos , Bexiga Urinária , Humanos , Ceramidas/química , Espectrometria de Massas , Ácidos Graxos , Cromatografia Líquida
5.
Histochem Cell Biol ; 157(3): 297-307, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35190876

RESUMO

Cryptorchidism is one of the most common abnormalities of male sexual development, and is characterized by the failure of the testis to descend into the scrotum. Despite extensive studies of cryptorchidism over the past century, the mechanisms for temperature-induced germ-cell loss are not well understood. All of the main cell types in the testis are believed to be affected by the elevated testis temperature induced by cryptorchidism. The cooler temperature in the special environment of the scrotum is required for maintaining optional conditions for normal spermatogenesis. Many studies reported that experimentally induced cryptorchidism caused germ cell apoptosis and suppressed spermatogenesis. However, other factors including hormones must also be examined for cryptorchidism. To explore the mechanism for cryptorchidism, in vitro cultures of testes have been used, but complete spermatogenesis using in vitro methods was not accomplished until 2011. In 2011, Sato et al. (Nature, 471, 504-507) reported the in vitro production of functional sperm in cultured neonatal mouse testes. Using this in vitro system, for the first time, we report that spermatogenesis was abrogated at 37 °C, in accordance with in vivo surgery-mediated cryptorchidism, while spermatogenesis proceeded at 34 °C in cultured testes. This result clearly showed that temperature is the sole determinant of cryptorchidism. Moreover, we found that spermatogenesis was arrested before early spermatocytes at 37 °C. In conclusion, using our in vitro system, we have demonstrated that (1) temperature is the determining factor for cryptorchidism, and (2) higher temperature (37 °C) suppresses DNA synthesis in spermatogenesis.


Assuntos
Criptorquidismo , Animais , Criptorquidismo/genética , Células Germinativas , Humanos , Masculino , Camundongos , Espermatogênese , Espermatozoides , Testículo/metabolismo
6.
Int J Clin Oncol ; 27(8): 1348-1355, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35596089

RESUMO

BACKGROUND: Apalutamide-associated skin adverse events are more common in the Japanese than in the global population. However, limited clinical data have hampered further understanding. This real-world study investigated the clinical characteristics of skin adverse events in patients with advanced prostate cancer. METHODS: We retrospectively reviewed 119 patient records from 16 institutions in Japan. Skin adverse events were graded according to the Common Terminology Criteria for Adverse Events (v5.0). The incidence and characteristics of skin adverse events (along with the clinical risk factors for their incidence, worsening, and recurrence) were evaluated. RESULTS: Fifty-five patients (46.2%) experienced skin adverse events. The median times to the incidence and remission of skin adverse events were 62 and 30 days, respectively. Grade 3 skin adverse events were observed in 15 patients (12.6%). The median time from the first incidence to apalutamide interruption was significantly longer in patients with progression to grade 3 skin adverse events than in those without such a progression (8 vs. 0 days, p = 0.005). Skin adverse events were observed in 45.2% of patients who resumed apalutamide treatment (median treatment interruption time: 31.5 days). Sixteen patients (13.4%) permanently discontinued apalutamide due to skin adverse events. No significant clinical risk factors for the incidence, worsening and recurrence of apalutamide-associated skin adverse events were observed. CONCLUSIONS: Nearly half of the Japanese patients in this study experienced skin adverse events following apalutamide administration. The time to apalutamide discontinuation after the incidence of skin adverse events was positively correlated with the worsening of these events.


Assuntos
Antagonistas de Receptores de Andrógenos , Neoplasias de Próstata Resistentes à Castração , Antagonistas de Receptores de Andrógenos/uso terapêutico , Humanos , Japão , Masculino , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Estudos Retrospectivos , Tioidantoínas
7.
Anal Chem ; 93(36): 12305-12311, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34464086

RESUMO

A fast response potentiometric flow-through pH sensor was applied for organic acid determination. The analyte response with the pH sensor was obtained by eluent pH modification following ion exclusion chromatography with HClO4 as an eluent. The response characteristics depend on the adjusted baseline pH. The baseline pH adjustment was successfully done with an ammonia permeation device without solution mixing, which may cause analyte dilution, dispersion, and mixing noise. After pH adjustment, the pH response was universal to the equivalent of introduced analyte acids because the pH response was obtained by the titration of the permeant ammonia by the analytes. The average of limit of detections (S/N = 3) was 0.06 mM for seven target organic acids. Furthermore, the pH response follows the theoretical pH calculation with the concentrations of the eluent, pH modifier, and analyte. Thus, the analyte concentration in the sample can be theoretically calculated from the pH response without calibration by the analyte standard. Predicted concentrations of injected standards were within 5% of the actual standard concentration. Additionally, analysis of real samples was performed and compared with the conventional post-column reaction with a bromothymol blue (BTB) method. The results obtained with the present system (absolute quantification with theoretical calculation) and conventional BTB method agreed within 10% of errors.


Assuntos
Compostos Orgânicos , Calibragem , Concentração de Íons de Hidrogênio , Padrões de Referência
8.
Anal Chem ; 93(51): 17069-17075, 2021 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-34910462

RESUMO

Short-lived radioactive metals are important tracers in clinical diagnosis. Radioactive metals for clinical use are produced from suitable target metals in cyclotrons. The trace amount of radioactive metal produced is contained in a relatively large amount of target metal. A rapid and effective method is required to isolate the radioactive metal. In the present study, selective complex formation followed by cation-exchange adsorption was performed in a continuous flow-based system. Ethylenediamine-N,N,N',N'-tetraacetic acid (EDTA) was selected as the ligand after simulation of the separation of radioactive Ga from the target (Zn). Selectively, the Ga-EDTA complex passed through the cation trap, while Zn2+ was trapped. This separation principle is opposite to that of typical solid-phase extraction, which captures the target ion. The proposed separation was performed in a flow-based system with a parallel, open-channel ion trap. The performance was optimized by altering the channel dimensions, channel-filling mesh, and flow rate. Finally, the target radioactive metal, Ga, was selectively and effectively (>99%) separated from a mixture of 50 fg Ga/L and 100 mg Zn/L. The concentration of Zn remaining in the Ga solution was 2.3 µg/L. The complexed Ga was converted to free Ga3+ by a simple UV irradiation method. The proposed method effectively and rapidly separates trace amounts of radioactive metals contained in larger amounts of target metals using a simple flow system that can be operated on site.


Assuntos
Ciclotrons , Metais , Indicadores e Reagentes , Extração em Fase Sólida
9.
Anal Chem ; 92(22): 14953-14958, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-32959650

RESUMO

Radioactive metals are applied in biochemistry, medical diagnosis such as positron emission tomography (PET), and cancer therapy. However, the activity of radioisotopes exponentially decreases with time; therefore, rapid and reliable probe preparation methods are strongly recommended. In the present study, electrodialytic radioactive metal ion handling is studied for counter ion conversion and in-line probe synthesis. Presently, counter ion conversion and probe synthesis are achieved by evaporative dryness and solution mixing, respectively. Evaporative dryness is time-consuming and is a possible process that can lead to loss of radioactive metal ions. Mixing of solutions for synthesis makes dilution and undesirable effects of counter ion on the synthesis. An optimized electrodialytic flow device can transfer a radioisotope, 64Cu2+, with high recovery from HCl matrices to HNO3 (∼100%). Matrices can also be transferred into acetic acid and citric acid, even though the concentration of the metal ion is at the picomolar level. The ion transfer can also be achieved with simultaneous counter ion conversion, complex synthesis, and enrichment. When the ligand was dissolved in an acceptor solution, the transferred metal ions from the donor were well mixed and formed a complex with the ligand in-line. The efficiency of the synthesis was ∼100% for 1.0 pM 64Cu. A relatively larger donor-to-acceptor flow rate can enrich the metal ion in the acceptor solution continuously. The flow rate ratio of 10 (donor/acceptor) can achieve 10 times enrichment. The present electrodialytic ion handling method can treat ultra-trace radioisotopes in a closed system. With this method, rapid, effective, and safe radioisotope treatments were achieved.


Assuntos
Técnicas Eletroquímicas/instrumentação , Metais/química , Radioisótopos/química , Ácido Clorídrico/química , Indicadores e Reagentes/química
10.
Anal Chem ; 91(16): 10484-10491, 2019 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-31337210

RESUMO

An automated device has been developed to measure aqueous dimethyl sulfide (DMSaq), its precursor dimethylsulfoniopropionate (DMSP), and atmospheric gaseous dimethyl sulfide (DMSg). In addition to having a role in the oceanic atmosphere, DMS and DMSP have recently gained substantial interest within the biosciences and are suspected as chemoattractants for predators searching for prey. To provide the spatial resolution relevant for biogeochemical functions, fast and on-site analysis of these compounds is an important technique. The system described measures the dimethyl sulfur compounds by sequential vaporization of DMSaq and DMSP to their gas phase, which is then analyzed by chemiluminescence detection (SVG-CL). The device has five analysis modes (full, DMS, water, gas, and DMSP mode) that can be selected by the user depending on the required analyte or desired sampling rate. Seawater analyses were performed by the developed SVG-CL system and, simultaneously, by an ion molecule reaction-mass spectrometer and a gas chromatograph-flame photometric detector to verify quantitative analysis results. Results obtained by the new method/device agreed well with those by the other methods. Detection limits of the SVG-CL system are 0.02 ppbv and 0.04 nM for DMSg and DMSaq/DMSP, respectively, which are much better than those of the mass spectrometer. The SVG-CL system can be easily installed and operated on a boat. Spatial variability in DMS and DMSP off the coast of Japan were obtained, showing significant changes in the concentrations of the components at the brackish/saline water interface and at the channel between the closed and open seas.

11.
Anal Chem ; 90(11): 6461-6467, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29733193

RESUMO

Most quantifications are achieved by comparison of the signals obtained with the sample to those from a standard. Thus, the purity and stability of the standard are key in chemical analysis. Furthermore, if an analyte standard cannot be obtained, quantification cannot be achieved, even if the chemical structures are identified by a qualification method (e.g., high-resolution mass spectrometry). Herein, we describe a universal and analyte standard-free detector for aqueous-eluent-based high-performance liquid chromatography. This universal carbon detector (UCD) was developed based on total organic carbon detection. Separated analytes were oxidized in-line and converted to carbon dioxide (CO2). Generated CO2 was transferred into the gas phase and collected into ultrapure water, which was followed by conductivity detection. The system can be applied as a HPLC detector that does not use an organic solvent as an eluent. The system can be calibrated with a primary standard of sodium bicarbonate for organic compounds. The universality and quantification were evaluated with organic compounds, including organic acids, sugars, and amino acids. Furthermore, the system was successfully applied to evaluation of the purity of formaldehyde in formalin solution, and determination of sugars in juices. The results show the universal carbon detector has good universality and can quantify many kinds of organic compounds with a single standard such as sodium bicarbonate.

12.
Anal Chem ; 89(13): 7203-7209, 2017 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-28570810

RESUMO

Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 µm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 µm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 µm i.d. column) of 500 µM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

13.
Anal Chem ; 87(22): 11575-80, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26507203

RESUMO

Large amounts of chromium (Cr) compounds are used for manufacturing of various products and various chemical processes. Some inevitably find their way into the environment. Environmental Cr is dominantly inorganic and is either in the cationic +3 oxidation state or in the anionic oxochromium +6 oxidation state. The two differ dramatically in their implications; Cr(III) is essential to human nutrition and even sold as a supplement, while Cr(VI) is a potent carcinogen. Drinking water standards for chromium may be based on total Cr or Cr(VI) only. Thus, Cr speciation analysis is very important. Despite their high sensitivity, atomic spectrometric techniques or induction coupled plasma-mass spectrometry (ICP-MS) cannot directly differentiate the oxidation states. We present here a new electrodialytic separation concept. Sample analyte ions are quantitatively transferred via appropriately ionically functionalized dialysis membranes into individual receptors that are introduced into the ICP-MS. There was no significant conversion of Cr(VI) to Cr(III) or vice versa during the very short (6 s) separation process. Effects of salinity (up to ∼20 mM NaCl) can be eliminated with proper membrane functionalization and receptor optimization. With the ICP-MS detector we used, the limits of detection for either form of Cr was 0.1 µg/L without preconcentration. Up to 10-fold preconcentration was readily possible by increasing the donor solution flow rate relative to the acceptor solution flow rates. The proposed approach permits simultaneous matrix isolation, preconcentration, and chromium speciation.


Assuntos
Cromo/análise , Cromo/química , Técnicas Eletroquímicas , Poluentes Químicos da Água/análise , Cromo/isolamento & purificação , Espectrometria de Massas , Cloreto de Sódio/química , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação
14.
Anal Chem ; 87(13): 6483-6, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26084326

RESUMO

A micro ion extractor (MIE) was developed for trace anion determination by ion chromatography-mass spectrometry from a single drop (25 µL) of whole blood without pretreatment. Target analytes were iodide and thiocyanate, which play key roles in thyroid hormone production. Whole blood (25 µL) was pipetted from an earlobe or finger prick and placed in the 16 µL cavity of the device. A reproducible fraction of iodide and thiocyanate was transferred through a membrane to an acceptor solution layer by electromigration for 60 s. An isolator solution layer and a cation exchange membrane is provided between the acceptor and the anode to prevent gas formation or redox processes in the acceptor. The acceptor contents are transferred online to the ion chromatograph. Isolator solution composition and applied voltage were optimized. Recoveries from samples from 16 different volunteers of both sexes and differing ages were the same within ±10% relative standard deviation. Dietary effects on blood iodide and thiocyanate levels are reported. The very low sample requirement permitted multiple sample collections per day. The MIE device is expected to be useful for clinical studies that require several/many temporally spaced blood samples by keeping the invasive nature of blood collection as minimal as possible.


Assuntos
Análise Química do Sangue , Dieta , Humanos , Iodetos/sangue , Fumar , Tiocianatos/sangue
15.
Int J Urol ; 22(6): 609-11, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25808696

RESUMO

We describe two cases in which dynamic analysis of ejaculation using color Doppler ultrasonography was useful in diagnosis of ejaculatory dysfunction and planning of therapy. The first patient was a 32-year-old man with a diagnosis of retrograde ejaculation. A bladder neck collagen injection was carried out, as the main cause was thought to be the bladder neck remaining open during ejaculation. The patient had antegrade ejaculation 1 week later. The second patient was a 48-year-old man with a diagnosis of anorgasmia accompanied by decreased seminal emission and insufficient function of the rhythmic pelvic striated muscles. The patient was prescribed etilefrine hydrochloride 15 mg/day. The symptom improved 2 weeks after starting this drug. These cases suggest that the use of color Doppler ultrasonography during ejaculation can improve the understanding of ejaculatory dysfunction and therapy for this condition.


Assuntos
Ejaculação , Disfunções Sexuais Fisiológicas/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adulto , Colágeno/administração & dosagem , Etilefrina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Orgasmo , Disfunções Sexuais Fisiológicas/fisiopatologia , Disfunções Sexuais Fisiológicas/terapia
16.
Environ Sci Technol ; 48(12): 6636-43, 2014 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-24857706

RESUMO

Formaldehyde (HCHO) is a highly soluble polar molecule with a large sticking coefficient and thus likely exists in both gaseous and particulate forms. Few studies, however, address particulate HCHO (HCHO(p)). Some report that HCHO(p) concentrations (obtained only with long duration sampling) are very low. The lack of data partly reflects the difficulty of specifically measuring HCHO(p). Long duration filter sampling may not produce meaningful results for a variety of reasons. In this work, gaseous HCHO (HCHO(g)) and (HCHO(p)) were, respectively, collected with a parallel plate wet denuder (PPWD) followed by a mist chamber/hydrophilic filter particle collector (PC). The PPWD quantitatively removed HCHO(g) and the PC then collected the transmitted aerosol. The collected HCHO from either device was alternately analyzed by Hantzsch reaction-based continuous flow fluorometry. Each gas and particle phase measurement took 5 min each, with a 10 min cycle. The limits of detection were 0.048 and 0.0033 µg m(-3), respectively, for HCHO(g) and HCHO(p). The instrument was deployed in three separate campaigns in a forest station in western Japan in March, May, and July of 2013. Based on 1296 data pairs, HCHO(p), was on the average, 5% of the total HCHO. Strong diurnal patterns were observed, with the HCHO(p) fraction peaking in the morning. The relative humidity dependence of the partition strongly suggests that it is driven by the liquid water content of the aerosol phase. However, HCHO(p) was 100× greater than that expected from Henry's law. We propose that the low water activity in the highly saline droplets lead to HCHO oligomerization.


Assuntos
Aerossóis/análise , Atmosfera/química , Formaldeído/análise , Ar/análise , Gases/análise , Umidade , Japão , Material Particulado/análise , Pentanonas/química , Estações do Ano , Soluções , Fatores de Tempo , Árvores/química , Água/química
17.
Anal Sci ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967710

RESUMO

Sampling and chromatography-mass spectrometry methods were investigated to measure atmospheric amines and aminoamides. Amines and their amide derivatives play significant roles in new particle formation (NPF) in the atmosphere, especially diamines and aminoamides have higher NPF potentials compared to monoamines. For amine sampling, silica gel tube collection and formic acid extraction gave good overall recoveries (>93 ± 8%) for mono-, di-, tri-, tetramines, and aminoamides. Two chromatography methods were subjected to analyze the extracted amines. One involved direct analysis using hydrophilic interaction liquid chromatography with carboxyl or diol group functioned separation column (carboxyl-HILIC or diol-HILIC), and the other utilized derivatization with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) and subsequent reversed-phase chromatography (HPLC). Separated amines were detected by electrospray ionization and tandem mass spectrometry in both cases. DBD-F-HPLC method provided good sensitivity for mono- and all polyamines (limit of detection (LOD) < 4.6 nM, relative standard deviation (RSD) for 100 nM < 9.2%). However, aminoamides could not be detected by DBD-F-HPLC. Carboxyl-HILIC provided good sensitivities for mono- and diamines and aminoamides (LOD < 1.6 nM, RSD < 4.8%). Forest air measurement was performed and data obtained by carboxyl-HILIC and DBD-F-HPLC showed good agreement for 1,3-diaminopropane, 1,4-diaminobutane (putrescine) and 1,5-diaminopentane (cadaverine) (R2 = 0.9215-0.9739, n = 7-14). Carboxyl-HILIC method was the best for the amine analysis, and combination with silica gel tube sampling provides atmospheric monitoring available. The developed method can be used not only to study atmospheric chemistry of diamines and aminoamides but also to analyze flavor/odor of foods, flowers and wastes.

18.
Anal Sci ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809340

RESUMO

Metal-organic frameworks (MOFs) are widely used for gas adsorption, separation, and sensing materials. In most cases, MOFs are not used in their crystal form but as impregnated materials because the fine crystals result in high-pressure drops. One key characteristic of MOF-impregnated materials is the amount of MOF in the material. This is evaluated using the wet digestion method; however, it is limited to determining only the metal content. Moreover, some metal, denoted as free metal, will not react with ligands to form MOFs. Additionally, it is crucial to determine the ligand amount, which cannot be determined using wet digestion. In the present study, a two-step extraction method for copper (II) benzene-1,3,5-tricarboxylate (Cu-BTC MOF) impregnated materials was developed to determine the MOF formed and free metals and ligands. Various solvents were applied to evaluate the extraction efficiencies. The results led to the selection of ethanol (EtOH) for extracting free Cu2+ and BTC, while 0.3 M HNO3 was chosen to extract MOF-formed Cu2+ and BTC. The MOF-impregnated sample material was first extracted using EtOH and then 0.3 M HNO3. The Cu2+ and BTC in the obtained extract solutions, as well as EtOH and HNO3, were analyzed using flame atomic absorption spectroscopy and high-performance liquid chromatography, respectively. In standard addition tests, free and MOF-formed Cu2+ and BTC were quantitatively extracted from MOF-impregnated materials. The developed two-step analysis method was successfully applied to Cu-BTC-impregnated materials used in gas sensing.

19.
Anal Chem ; 85(9): 4461-7, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23551252

RESUMO

A small, simple device was developed for trace analysis of dimethyl sulfide (DMS) and dimethylsulfoniopropionate (DMSP) in natural waters. These compounds are known to be the major sources of cloud condensation nuclei in the oceanic atmosphere and ideally should be measured onsite because of their volatility and instability. First, chemical and physical vapor generations were examined, and simple pressurizing by injection of 30 mL of air using a syringe was adopted. Pressurized headspace air above a 10 mL water sample was introduced to a detection cell as a result of the pressure differential and mixed with ozone to induce chemiluminescence. Although the measurement procedure was simple, the method was very sensitive: sharp peaks appeared within seconds for nanomolar levels of DMS, and the limit of detection was 0.02 nmol L(-1) (1 ng L(-1)). Although interference from methanethiol was significant, this was successfully addressed by adding a small amount of Cd(2+) before DMS vapor generation. DMSP was also measured after hydrolysis to DMS, as previously reported. Pond water and seawater samples were analyzed, and DMS was found in both types of sample, whereas DMSP was observed only in seawater. The DMS/DMSP data obtained using the developed method were compared with data obtained by purge/trap and gas chromatography-mass spectrometry, and the data from the two methods agreed, with good correlation (R(2) = 0.9956). The developed device is inexpensive, light (5 kg), simple to use, can be applied in the field, and is sensitive enough for fresh- and seawater analysis.


Assuntos
Luminescência , Medições Luminescentes , Sulfetos/análise , Compostos de Sulfônio/análise , Água/química , Medições Luminescentes/instrumentação , Volatilização
20.
Commun Biol ; 6(1): 1194, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-38001159

RESUMO

Phytoplanktonic dinoflagellates form colonies between vertical ice crystals during the ice-melting season in Lake Baikal, but how the plankton survive the freezing conditions is not known. Here we show that the phytoplankton produces large amounts of dimethylsulfoniopropionate (DMSP), which is best-known as a marine compound. Lake-water DMSP concentrations in the spring season are comparable with those in the oceans, and colony water in ice exhibits extremely high concentrations. DMSP concentration of surface water correlates with plankton density and reaches a maximum in mid-April, with temperature-dependent fluctuations. DMSP is released from plankton cells into water in warm days. DMSP is a characteristic osmolyte of marine algae; our results demonstrate that freshwater plankton, Gymnodinium baicalense, has DMSP-producing ability, and efficiently uses the limited sulfur resource (only 1/500 of sea sulfate) to survive in freshwater ice. Plankton in Lake Baikal do not need an osmolyte, and our results clearly indicate that DMSP plays a cryoprotective role. DMSP, although a characteristic marine compound, could also be an important zwitterion for algae of other boreal lakes, alpine snow, and glaciers.


Assuntos
Dinoflagellida , Fitoplâncton , Lagos , Camada de Gelo , Plâncton , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA