Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475156

RESUMO

A new nondestructive inspection method, the magnetic hammer test (MHT), which uses a compact and highly sensitive tunnel magnetoresistance (TMR) sensor, is proposed. This method complements the magnetic flux leakage method and eliminates the issues of the hammer test. It can therefore detect weak magnetic fields generated by the natural vibration of a pipe with a high signal-to-noise ratio. In this study, several steel pipes with different wall thicknesses were measured using a TMR sensor to demonstrate the superiority of MHT. The results of the measurement show that wall thickness can be evaluated with the accuracy of several tens of microns from the change in the natural vibration frequency of the specimen pipe. The pipes were also inspected underwater using a waterproofed TMR sensor, which demonstrated an accuracy of less than 100 µm. The validity of these results was by simulating the shielding of magnetic fields and vibration of the pipes with the finite element method (FEM) analysis. The proposed noncontact, fast, and accurate method for thickness testing of long-distance pipes will contribute to unmanned, manpower-saving nondestructive testing (NDT) in the future.

2.
Sensors (Basel) ; 23(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36679442

RESUMO

A magnetocardiograph that enables the clear observation of heart magnetic field mappings without magnetically shielded rooms at room temperatures has been successfully manufactured. Compared to widespread electrocardiographs, magnetocardiographs commonly have a higher spatial resolution, which is expected to lead to early diagnoses of ischemic heart disease and high diagnostic accuracy of ventricular arrhythmia, which involves the risk of sudden death. However, as the conventional superconducting quantum interference device (SQUID) magnetocardiographs require large magnetically shielded rooms and huge running costs to cool the SQUID sensors, magnetocardiography is still unfamiliar technology. Here, in order to achieve the heart field detectivity of 1.0 pT without magnetically shielded rooms and enough magnetocardiography accuracy, we aimed to improve the detectivity of tunneling magnetoresistance (TMR) sensors and to decrease the environmental and sensor noises with a mathematical algorithm. The magnetic detectivity of the TMR sensors was confirmed to be 14.1 pTrms on average in the frequency band between 0.2 and 100 Hz in uncooled states, thanks to the original multilayer structure and the innovative pattern of free layers. By constructing a sensor array using 288 TMR sensors and applying the mathematical magnetic shield technology of signal space separation (SSS), we confirmed that SSS reduces the environmental magnetic noise by -73 dB, which overtakes the general triple magnetically shielded rooms. Moreover, applying digital processing that combined the signal average of heart magnetic fields for one minute and the projection operation, we succeeded in reducing the sensor noise by about -23 dB. The heart magnetic field resolution measured on a subject in a laboratory in an office building was 0.99 pTrms and obtained magnetocardiograms and current arrow maps as clear as the SQUID magnetocardiograph does in the QRS and ST segments. Upon utilizing its superior spatial resolution, this magnetocardiograph has the potential to be an important tool for the early diagnosis of ischemic heart disease and the risk management of sudden death triggered by ventricular arrhythmia.


Assuntos
Magnetocardiografia , Isquemia Miocárdica , Humanos , Coração , Arritmias Cardíacas/diagnóstico , Morte Súbita
3.
Sensors (Basel) ; 21(2)2021 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-33477948

RESUMO

Thanks to high sensitivity, excellent scalability, and low power consumption, magnetic tunnel junction (MTJ)-based tunnel magnetoresistance (TMR) sensors have been widely implemented in various industrial fields. In nondestructive magnetic flux leakage testing, the magnetic sensor plays a significant role in the detection results. As highly sensitive sensors, integrated MTJs can suppress frequency-dependent noise and thereby decrease detectivity; therefore, serial MTJ-based sensors allow for the design of high-performance sensors to measure variations in magnetic fields. In the present work, we fabricated serial MTJ-based TMR sensors and connected them to a full Wheatstone bridge circuit. Because noise power can be suppressed by using bridge configuration, the TMR sensor with Wheatstone bridge configuration showed low noise spectral density (0.19 µV/Hz0.5) and excellent detectivity (5.29 × 10-8 Oe/Hz0.5) at a frequency of 1 Hz. Furthermore, in magnetic flux leakage testing, compared with one TMR sensor, the Wheatstone bridge TMR sensors provided a higher signal-to-noise ratio for inspection of a steel bar. The one TMR sensor system could provide a high defect signal due to its high sensitivity at low lift-off (4 cm). However, as a result of its excellent detectivity, the full Wheatstone bridge-based TMR sensor detected the defect even at high lift-off (20 cm). This suggests that the developed TMR sensor provides excellent detectivity, detecting weak field changes in magnetic flux leakage testing.

4.
Sensors (Basel) ; 20(19)2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-33036470

RESUMO

Thanks to their high magnetoresistance and integration capability, magnetic tunnel junction-based magnetoresistive sensors are widely utilized to detect weak, low-frequency magnetic fields in a variety of applications. The low detectivity of MTJs is necessary to obtain a high signal-to-noise ratio when detecting small variations in magnetic fields. We fabricated serial MTJ-based sensors with various junction area and free-layer electrode aspect ratios. Our investigation showed that their sensitivity and noise power are affected by the MTJ geometry due to the variation in the magnetic shape anisotropy. Their MR curves demonstrated a decrease in sensitivity with an increase in the aspect ratio of the free-layer electrode, and their noise properties showed that MTJs with larger junction areas exhibit lower noise spectral density in the low-frequency region. All of the sensors were able detect a small AC magnetic field (Hrms = 0.3 Oe at 23 Hz). Among the MTJ sensors we examined, the sensor with a square-free layer and large junction area exhibited a high signal-to-noise ratio (4792 ± 646). These results suggest that MTJ geometrical characteristics play a critical role in enhancing the detectivity of MTJ-based sensors.

5.
Sensors (Basel) ; 19(21)2019 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-31671677

RESUMO

Magnetic flux leakage (MFL) testing is a method of non-destructive testing (NDT), whereby the material is magnetized, and when a defect is present, the magnetic flux lines break out of the material. The magnitude of the leaked magnetic flux decreases as the lift-off (distance from the material) increases. Therefore, for detection at high lift-off, a sensitive magnetic sensor is required. To increase the output sensitivity, this paper proposes the application of magnetic tunnel junction (MTJ) sensors in a bridge circuit for the NDT of reinforced concrete at high lift-off. MTJ sensors were connected to a full-bridge circuit, where one side of the arm has two MTJ sensors connected in series, and the other contains a resistor and a variable resistor. Their responses towards a bias magnetic field were measured, and, based on the results, the sensor circuit sensitivity was 0.135 mV/mT. Finally, a reinforced concrete specimen with a 1 cm gap in the center was detected. The sensor module (with an amplifier and low pass filter circuits) could determine the gap even at 50 cm, suggesting that MTJ sensors have the potential to detect defects at high lift-off values and have a promising future in the field of NDT.

6.
Nano Lett ; 15(1): 623-8, 2015 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-25549140

RESUMO

Spin dynamics excited by spin-polarized current in magnetic tunnel junctions (MTJs) is potentially useful in nanoscale electrical oscillation sources and detection devices. A spin oscillator/detector should work at a high frequency, such as that of a millimeter-wave, where the quality of a semiconductor device is restricted by carrier mobility, the CR time constant, and so on. Developers of spin systems for practical use need to find out how to excite spin dynamics (i) in the millimeter-wave region, (ii) with low power consumption (ex: no external magnetic field, low damping material), and (iii) for broad frequency modulation. Here L10-ordered FePd alloy with perpendicular magnetocrystalline anisotropy (PMA) and a low damping constant, 0.007, was used for the free layer in the MTJs, and a homodyne-detected ferromagnetic resonance (FMR) signal was obtained at around 30 GHz together with the possibility of one-octave frequency modulation. The FMR signal in out-of-plane magnetized L10-ordered FePd free layer could be excited without an external magnetic field by injecting in-plane spin polarized alternating current. This study shows the potential utility of L10-ordered alloy materials such as FePt, CoPt, MnAl, and MnGa in a variety of millimeter-wave spin devices.

7.
Sci Rep ; 12(1): 6106, 2022 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-35414691

RESUMO

Non-invasive human brain functional imaging with millisecond resolution can be achieved only with magnetoencephalography (MEG) and electroencephalography (EEG). MEG has better spatial resolution than EEG because signal distortion due to inhomogeneous head conductivity is negligible in MEG but serious in EEG. However, this advantage has been practically limited by the necessary setback distances between the sensors and scalp, because the Dewar vessel containing liquid helium for superconducting quantum interference devices (SQUIDs) requires a thick vacuum wall. Latest developments of high critical temperature (high-Tc) SQUIDs or optically pumped magnetometers have allowed closer placement of MEG sensors to the scalp. Here we introduce the use of tunnel magneto-resistive (TMR) sensors for scalp-attached MEG. Improvement of TMR sensitivity with magnetic flux concentrators enabled scalp-tangential MEG at 2.6 mm above the scalp, to target the largest signal component produced by the neural current below. In a healthy subject, our single-channel TMR-MEG system clearly demonstrated the N20m, the initial cortical component of the somatosensory evoked response after median nerve stimulation. Multisite measurement confirmed a spatially and temporally steep peak of N20m, immediately above the source at a latency around 20 ms, indicating a new approach to non-invasive functional brain imaging with millimeter and millisecond resolutions.


Assuntos
Magnetoencefalografia , Couro Cabeludo , Encéfalo/fisiologia , Mapeamento Encefálico/métodos , Eletroencefalografia , Humanos , Magnetoencefalografia/métodos
8.
Phys Rev Lett ; 105(21): 217202, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-21231346

RESUMO

We investigate the ultrafast demagnetization for two Heusler alloys (Co2Mn(1-x)FexSi) with a different lineup of the minority band gap and the Fermi level. Even though electronic spin-flip transitions are partially blocked by the band gap in one compound, the respective magnetization dynamics, as measured by the time-resolved Kerr effect, are remarkably similar. Based on a dynamical model that includes momentum and spin-dependent carrier scattering, we show that the magnetization dynamics are dominated by hole spin-flip processes, which are not influenced by the gap.

9.
Sci Rep ; 9(1): 17018, 2019 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-31745142

RESUMO

We studied the effect of second-order magnetic anisotropy on the linear conductance output of magnetic tunnel junctions (MTJs) for magnetic-field-sensor applications. Experimentally, CoFeB/MgO/CoFeB-based MTJs were fabricated, and the nonlinearity, NL was evaluated for different thicknesses, t of the CoFeB free layer from the conductance. As increasing t from 1.5 to 2.0 nm, maximum NL, NLmax was found to decrease from 1.86 to 0.17% within the dynamic range, Hd = 1.0 kOe. For understanding the origin of such NL behavior, a theoretical model based on the Slonczewski model was constructed, wherein the NL was demonstrated to be dependent on both the normalized second-order magnetic anisotropy field of Hk2/|Hkeff| and the normalized dynamic range of Hd/|Hkeff|. Here, Hkeff, Hk2, are the effective and second-order magnetic anisotropy field of the free layer in MTJ. Remarkably, experimental NLmax plotted as a function of Hk2/|Hkeff| and Hd/|Hkeff|, which were measured from FMR technique coincided with the predictions of our model. Based on these experiment and calculation, we conclude that Hk2 is the origin of NL and strongly influences its magnitude. This finding gives us a guideline for understanding NL and pioneers a new prospective for linear-output MTJ sensors to control sensing properties by Hk2.

10.
Nanoscale Res Lett ; 11(1): 33, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26787052

RESUMO

The effects of Nd2Fe14B grain size and Nd coating on the coercivity in sputter-deposited Nd-Fe-B/Nd thin films have been investigated in order to gain an insight into the coercivity mechanism of Nd-Fe-B magnets. Highly textured Nd2Fe14B particles were grown successfully on the MgO(100) single-crystal substrate with the Mo underlayer. As the Nd-Fe-B layer thickness t NFB was decreased from 70 to 5 nm, the coercivity H c increased gradually from 6.5 to 16 kOe. By depositing the Nd overlayer onto these films and post-annealing at 500 °C, the H c value further increased from 17.5 kOe (t NFB=70 nm) to 26.2 kOe (t NFB=5 nm). The amount of H c increase by the combination of the Nd coating and post-annealing was about 10 kOe irrespective of the t NFB value. These results therefore suggest an independence of size and interface effects on the coercivity of Nd-Fe-B magnets.

11.
Sci Rep ; 5: 8537, 2015 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-25702631

RESUMO

Ultraviolet photoemission spectroscopy (UPS) is a powerful tool to study the electronic spin and symmetry features at both surfaces and interfaces to ultrathin top layers. However, the very low mean free path of the photoelectrons usually prevents a direct access to the properties of buried interfaces. The latter are of particular interest since they crucially influence the performance of spintronic devices like magnetic tunnel junctions (MTJs). Here, we introduce spin-resolved extremely low energy photoemission spectroscopy (ELEPS) to provide a powerful way for overcoming this limitation. We apply ELEPS to the interface formed between the half-metallic Heusler compound Co2MnSi and the insulator MgO, prepared as in state-of-the-art Co2MnSi/MgO-based MTJs. The high accordance between the spintronic fingerprint of the free Co2MnSi surface and the Co2MnSi/MgO interface buried below up to 4 nm MgO provides clear evidence for the high interface sensitivity of ELEPS to buried interfaces. Although the absolute values of the interface spin polarization are well below 100%, the now accessible spin- and symmetry-resolved wave functions are in line with the predicted existence of non-collinear spin moments at the Co2MnSi/MgO interface, one of the mechanisms evoked to explain the controversially discussed performance loss of Heusler-based MTJs at room temperature.

12.
Materials (Basel) ; 7(3): 1473-1482, 2014 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-28788526

RESUMO

In this work we present a theoretical study of the effect of disorder on spin polarisation at the Fermi level, and the disorder formation energies for Co2FexMn1-xSi (CFMS) alloys. The electronic calculations are based on density functional theory with a Hubbard U term. Chemical disorders studied consist of swapping Co with Fe/Mn and Co with Si; in all cases we found these are detrimental for spin polarisation, i.e., the spin polarisation not only decreases in magnitude, but also can change sign depending on the particular disorder. Formation energy calculation shows that Co-Si disorder has higher energies of formation in CFMS compared to Co2MnSi and Co2FeSi, with maximum values occurring for x in the range 0.5-0.75. Cross-sectional structural studies of reference Co2MnSi, Co2Fe0.5Mn0.5Si, and Co2FeSi by Z-contrast scanning transmission electron microscopy are in qualitative agreement with total energy calculations of the disordered structures.

13.
Nat Commun ; 4: 1392, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23340432

RESUMO

The integration of organic semiconductors and magnetism has been a fascinating topic for fundamental scientific research and future applications in electronics, because organic semiconductors are expected to possess a large spin-dependent transport length based on weak spin-orbit coupling and weak hyperfine interaction. However, to date, this length has typically been limited to several nanometres at room temperature, and a large length has only been observed at low temperatures. Here we report on a novel organic spin valve device using C(60) as the spacer layer. A magnetoresistance ratio of over 5% was observed at room temperature, which is one of the highest magnetoresistance ratios ever reported. Most importantly, a large spin-dependent transport length of approximately 110 nm was experimentally observed for the C(60) layer at room temperature. These results provide insights for further understanding spin transport in organic semiconductors and may strongly advance the development of spin-based organic devices.

14.
Materials (Basel) ; 4(6): 1087-1095, 2011 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-28879967

RESUMO

The 10 at.% Co-substituted BiFeO3 films (of thickness 50 nm) were successfully prepared by radio frequency (r.f.) magnetron sputtering on SrTiO3 (100) substrates with epitaxial relationships of [001](001)Co-BiFeO3//[001](001)SrTiO3. In this study, a single phase Co-substituted BiFeO3 epitaxial film was fabricated by r.f. magnetron sputtering. Sputtering conditions such as Ar, O2 gas pressure, annealing temperature, annealing atmosphere, and sputtering power were systematically changed. It was observed that a low Ar gas pressure and low sputtering power is necessary to suppress the formation of the secondary phases of BiOx. The Co-substituted BiFeO3 films were crystalized with post-annealing at 600 °C in air. The process window for single phase films is narrower than that for pure BiFeO3 epitaxial films. By substituting Fe with Co in BiFeO3, the magnetization at room temperature increased to 20 emu/cm³. This result suggests that Co-substituted BiFeO3 films can be used in spin-filter devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA