Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(5)2022 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-35271185

RESUMO

A new method is proposed in this paper to detect airborne nanoparticles, detecting the light scattering caused by both the particle and the surrounding molecules, which can surpass the limitations of conventional laser optical methods while maintaining simplicity and cost-effectiveness. This method is derived from a mathematical analysis that describes the particle light scattering phenomenon more exactly by including the influence of light scattered from surrounding gas molecules. The analysis shows that it is often too much of a simplification to consider only light scattering from the detected nanoparticle, because light scattering from the surrounding gas molecules, whether visible or invisible to the sensor, is important for nanoparticle detection. An image detection approach utilizing the light scattering from surrounding air molecules is described for the detection of airborne nanoparticles. Tests using monodisperse nanoparticles confirm that airborne particles of around 50 nm in size can even be detected using a low-cost testing device. This shows further that even when using a simple image processing code, captured particle light scattering images can be converted digitally into instantaneous particle counts or concentrations. The factors limiting conventional pulse detection are further discussed. This new method utilizes a simple static light scattering (SLS) approach to enable the development of new devices with better detection capabilities, paving the way for the further development of nanoparticle detection technology.


Assuntos
Nanopartículas , Lasers , Tamanho da Partícula , Espalhamento de Radiação
2.
Environ Sci Technol ; 54(18): 11230-11236, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32786575

RESUMO

Filtration via a porous medium is a ubiquitous process where high-fidelity physical models are needed. The classical cell model oversimplifies the filtration medium and results in biased and inaccurate predictions of the filter performance. This paper presents the discrete framework of a polydisperse cell model that can incorporate any measured pore size distribution. A new equation connecting the polydisperse cell efficiencies and the medium efficiency is derived from first principles. For ceramic filters, the discrete model demonstrates a generic prediction capability of the filtration efficiency with a root-mean-squared difference of 5.4%, while the counterpart of the classical cell model is 26.4%. In addition, the discrete model eliminates the biased predictions of the classical cell model on sub-100 nm particles.


Assuntos
Filtração , Modelos Teóricos , Tamanho da Partícula , Porosidade
3.
J Aerosol Sci ; 150: 105609, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32834104

RESUMO

This study aims to evaluate the filtration performance of three commercially available (3M 8210 respirator, Halyard 48207 surgical mask, and 3M 1820 procedure mask) and two alternative face mask and respirator materials (Halyard H600 sterilization wrap and Cummins EX101) after selected decontamination treatments, including isopropanol (IPA) treatments (soaking or spraying), ultraviolet germicidal irradiation (UVGI), and heat treatments (dry heat at 77 °C or steam heat). Both IPA soaking and spraying removed most electrostatic charges on all four electret materials (three commercial and one alternative), causing significant deterioration of filtration efficiency to unacceptable level. The other non-electret alternative material sustained its N95-grade performance after both IPA soaking and spraying treatments, demonstrating the possible application of IPA disinfection for non-electret alternative respirator/mask materials. UVGI preserved the filtration of all three commercially available respirator/mask materials after up to 10 treatments, suggesting it can be a possible decontamination method for hospital and clinic use without compromising respirator/mask performance. The considerations of the practical implementation of this method was discussed. Between the two heat treatment methods tested, dry heat showed better compatibility with electret material by sustaining both filtration efficiency and fit (tested on commercial respirator only), although adding moisture was reported in favor of virus inactivation. Heat treatment is easily accessible method for general publics to implement at home, while it is recommended to maintain the moisture level below saturation. Comparing to size-integrated method, the size-resolved fractional efficiency measurement technique, although more time consuming, proved to be a better method for evaluating respirator/mask filtration performance after decontaminations by providing more sensitive detection of performance degradation and the capability of distinguishing charge loss to other mechanisms causing efficiency deterioration. Detailed descriptions are provided in methodology part to emphasize the cares needed for an appropriate efficiency evaluation. The limited results in this study on worn masks made of alternative sterilization wrap indicated possible performance degradation of electret material caused by normal human wearing activities, suggesting the need of assessing respirator/mask decontamination strategy by testing practically worn-and-decontaminated/reused samples instead of unworn only-decontaminated counterparts.

4.
J Med Device ; 16(1): 015001, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35280214

RESUMO

At the beginning of the COVID-19 pandemic when traditional N95 respirators were in short supply in the United States, there was a need for alternative products that did not rely on traditional avenues of sourcing and manufacturing. The purpose of this research was to develop and test alternatives to N95 respirators that could be produced locally without specialized materials and processes. Through an interdisciplinary team of experts, new mask designs that use repurposed filtration media and commercially available components were developed and tested for filtration and fit against current N95 standards. Filtration efficiency test results showed that the filtration media can be used for high-quality facemasks and quantitative fit testing demonstrated that the new mask designs could be viable alternatives to traditional N95 facemasks when those masks are in short supply. Manufacturing viability was tested utilizing a workforce to create 6000 masks over 10 days. The ability to quickly produce masks at scale using a workforce without specialized skills demonstrated the feasibility of the mask designs and manufacturing approach to address shortages of critical healthcare equipment, mitigate risk for healthcare and essential workers, and minimize the transmission and spread of disease.

5.
J Am Dent Assoc ; 152(12): 981-990, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34538418

RESUMO

BACKGROUND: Dental procedures often produce aerosols and spatter, which have the potential to transmit pathogens such as severe acute respiratory syndrome coronavirus 2. The existing literature is limited. METHODS: Aerosols and spatter were generated from an ultrasonic scaling procedure on a dental manikin and characterized via 2 optical imaging methods: digital inline holography and laser sheet imaging. Capture efficiencies of various aerosol mitigation devices were evaluated and compared. RESULTS: The ultrasonic scaling procedure generated a wide size range of aerosols (up to a few hundred µm) and occasional large spatter, which emit at low velocity (mostly < 3 m/s). Use of a saliva ejector and high-volume evacuator (HVE) resulted in overall reductions of 63% and 88%, respectively, whereas an extraoral local extractor (ELE) resulted in a reduction of 96% at the nominal design flow setting. CONCLUSIONS: The study results showed that the use of ELE or HVE significantly reduced aerosol and spatter emission. The use of HVE generally requires an additional person to assist a dental hygienist, whereas an ELE can be operated hands free when a dental hygienist is performing ultrasonic scaling and other operations. PRACTICAL IMPLICATIONS: An ELE aids in the reduction of aerosols and spatters during ultrasonic scaling procedures, potentially reducing transmission of oral or respiratory pathogens like severe acute respiratory syndrome coronavirus 2. Position and airflow of the device are important to effective aerosol mitigation.


Assuntos
COVID-19 , Ultrassom , Aerossóis , Raspagem Dentária , Humanos , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA