Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Sleep Med ; 20(1): 49-55, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38163943

RESUMO

STUDY OBJECTIVES: In coronary artery bypass grafting (CABG), abnormal cardiac repolarization is associated with adverse cardiovascular events that can be measured via the QTc interval. We investigated the impact of obstructive sleep apnea on the change in repolarization after CABG and the association of change in repolarization with the occurrence of major adverse cardiac and cerebrovascular events. METHODS: A total of 1,007 patients from 4 hospitals underwent an overnight sleep study prior to a nonemergent CABG. Electrocardiograms of 954 patients (median age: 62 years; male: 86%; mean follow-up: 2.1 years) were acquired prospectively within 48 hours before CABG (T1) and within 24 hours after CABG (T2). QTc intervals were measured using the BRAVO algorithm by Analyzing Medical Parameters for Solutions LLC. The change in T2 from T1 for QTc (ΔQTc) was derived, and Cox regression was performed. RESULTS: Compared with those without, patients who developed major adverse cardiac and cerebrovascular events (n = 115) were older and had (1) a higher prevalence of smoking, hypertension, diabetes mellitus, and chronic kidney disease; (2) a higher apnea-hypopnea index and oxygen desaturation index; and (3) a smaller ΔQTc. Cox regression analysis demonstrated a smaller ΔQTc to be an independent risk factor for major adverse cardiac and cerebrovascular events (hazard ratio: 0.997; P = .032). In the multivariable regression model, a higher oxygen desaturation index was independently associated with a smaller ΔQTc (correlation coefficient: -0.58; P < .001). CONCLUSIONS: A higher preoperative oxygen desaturation index was an independent predictor of a smaller ΔQTc. ΔQTc within 24 hours after CABG could be a novel predictor of occurrence of major adverse cardiac and cerebrovascular events at medium-term follow-up. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Undiagnosed Sleep Apnea and Bypass OperaTion (SABOT); URL: https://classic.clinicaltrials.gov/ct2/show/NCT02701504; Identifier: NCT02701504. CITATION: Teo YH, Yong CL, Ou YH, et al. Obstructive sleep apnea and temporal changes in cardiac repolarization in patients undergoing coronary artery bypass grafting. J Clin Sleep Med. 2024;20(1):49-55.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Masculino , Pessoa de Meia-Idade , Ponte de Artéria Coronária/efeitos adversos , Apneia Obstrutiva do Sono/diagnóstico , Síndromes da Apneia do Sono/complicações , Fatores de Risco , Oxigênio
2.
J Am Coll Cardiol ; 83(18): 1760-1772, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38588926

RESUMO

BACKGROUND: Hypertension guidelines recommend diagnosis and treatment of obstructive sleep apnea (OSA) in patients with hypertension. The mandibular advancement device (MAD) is an oral appliance therapy for patients who decline or cannot tolerate continuous positive airway pressure (CPAP). OBJECTIVES: We compared the relative effectiveness of MAD vs CPAP in reducing 24-hour ambulatory blood pressure (BP). METHODS: In an investigator-initiated, randomized, noninferiority trial (prespecified margin 1.5 mm Hg), 321 participants aged ≥40 years with hypertension and increased cardiovascular risk were recruited at 3 public hospitals for polysomnography. Of these, 220 participants with moderate-to-severe OSA (apnea-hypopnea index ≥15 events per hour) were randomized to either MAD or CPAP (1:1). The primary outcome was the difference between the 24-hour mean arterial BP at baseline and 6 months. RESULTS: Compared with baseline, the 24-hour mean arterial BP decreased by 2.5 mm Hg (P = 0.003) at 6 months in the MAD group, whereas no change was observed in the CPAP group (P = 0.374). The between-group difference was -1.6 mm Hg (95% CI: -3.51 to 0.24, noninferiority P < 0.001). The MAD group demonstrated a larger between-group reduction in all secondary ambulatory BP parameters compared with the CPAP group, with the most pronounced effects observed in the asleep BP parameters. Both the MAD and CPAP improved daytime sleepiness, with the between-group difference similar (P = 0.384). There were no between-group differences in cardiovascular biomarkers. CONCLUSIONS: MAD is noninferior to CPAP for reducing 24-hour mean arterial BP in participants with hypertension and increased cardiovascular risk. (Cardiosleep Research Program on Obstructive Sleep Apnea, Blood Pressure Control and Maladaptive Myocardial Remodeling-Non-inferiority Trial [CRESCENT]; NCT04119999).


Assuntos
Pressão Sanguínea , Pressão Positiva Contínua nas Vias Aéreas , Hipertensão , Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/fisiopatologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Avanço Mandibular/instrumentação , Hipertensão/terapia , Hipertensão/fisiopatologia , Hipertensão/complicações , Pressão Sanguínea/fisiologia , Polissonografia , Idoso , Monitorização Ambulatorial da Pressão Arterial/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA