RESUMO
Head trauma is frequently related to the misuse of drinking vessels as weapons. Forensic reports usually evaluate these blunt injuries as having occurred in scenarios where the alcohol intake is high. Fatal consequences are seen in blows with glass bottles aiming at the head. To prove the outcome that a glass bottle thrown to the head could cause, three intact human cadaver heads were impacted with 1-liter glass bottles at 9.5 m/s using a drop-tower. The impact location covered the left temporal bone, sphenoid bone, and zygomatic arch. The contact between the head and the bottle was produced at an angle of 90° with (1) the valve of the bottle, (2) the bottom of the bottle, and (3) with the head rotated 20° in the frontal plane touching again with the bottom of the bottle. The three bottles remained intact after the impact, and the injury outcomes were determined by computed tomography (CT). The alterations were highly dependent on the impact orientation. The outcome varied from no injury to severe bone fractures. In the most injurious case (#3), fractures were identified in the cranial base, sphenoid bone, and zygomatic bone. These testing conditions were selected to replicate one specific legal case, as required by the plaintiff. Physical disputes with bar glassware can lead to complex combinations of blunt and sharp-force injuries. Controlled biomechanical studies can benefit forensic analyses of violence involving glassware by providing a better understanding of the underlying injury mechanisms.
Assuntos
Fraturas Cranianas , Ferimentos não Penetrantes , Humanos , Osso Temporal , Violência , CadáverRESUMO
CONTEXT: Anterior cruciate ligament injuries are directly related to the control of dynamic knee valgus in the landing of a jump, and this is mainly due to the correct activation and neuromuscular function of the lower-extremity muscles. The aim of the study is to assess the relationship between lower limb muscle activity during a single-legged drop jump and knee frontal plane projection angle (FPPA). DESIGN: A correlation study. METHODS: Thirty healthy collegiate female athletes were included in the study. Main outcomes measures were peak knee FPPA and muscle activity (% of maximal voluntary isometric contraction). Peak knee FPPA during a single-legged drop jump test was identified using a 2-dimensional motion analysis system. Muscle activity was assessed using a surface electromyograph for gluteus maximus, gluteus medius, biceps femoris, semitendinosus, vastus medialis quadriceps, vastus lateralis quadriceps, medial gastrocnemius, and lateral gastrocnemius. All variables were assessed for both dominant and nondominant limbs. A correlation analysis between peak knee FPPA and muscle activity was performed. Statistical significance was set at P <.05. RESULTS: A mean peak knee FPPA of 14.52° and 13.38° was identified for dominant and nondominant limb single-legged drop jump test, respectively. Muscle activity (% of maximal voluntary isometric contraction) for muscles assessed ranged from 43.97% to 195.71% during the single-legged drop jump test. The correlation analysis found no significant correlation between any of the muscles assessed and peak knee FPPA during the single-legged drop jump test (Pearson coefficient between -.3 and .1). CONCLUSIONS: There is no association between muscle activity from the lower limb muscles and the knee FPPA during a single-legged drop jump in female athletes. Thus, different muscle properties should be assessed in order to understand such an important movement as the knee FPPA during a jump.
Assuntos
Articulação do Joelho , Joelho , Feminino , Humanos , Articulação do Joelho/fisiologia , Músculo Quadríceps , Atletas , NádegasRESUMO
OBJECTIVE: To analyze the changes over time in the strain on the inferior iliofemoral (IIF) ligament when a constant high-force long-axis distraction mobilization (LADM) was applied over 5 minutes. DESIGN: A cross-sectional laboratory cadaveric study. SETTING: Anatomy laboratory. PARTICIPANTS: Thirteen hip joints from 9 fresh-frozen cadavers (mean age, 75.6±7.8 years; N=13). INTERVENTIONS: High-force LADM in open-packed position was sustained for a period of 5 minutes. MAIN OUTCOME MEASURE(S): Strain on IFF ligament was measured over time with a microminiature differential variable reluctance transducer. Strain measurements were taken at every 15 seconds for the first 3 minutes and every 30 seconds for the next 2 minutes. RESULTS: Major changes in strain occurred in the first minute of high-force LADM application. The greatest increase in strain on the IFF ligament occurred at the first 15 seconds (7.3±7.2%). At 30 seconds, the increase in strain was 10.1±9.6%, the half of the total increase at the end of the 5-minute high-force LADM (20.2±8.5%). Significant changes in strain measures were shown to occur at 45 seconds of high-force LADM (F=18.11; P<.001). CONCLUSIONS: When a 5-minute high-force LADM was applied, the major changes in the strain on IIF ligament occurred in the first minute of the mobilization. A high-force LADM mobilization should be sustained at least 45 seconds to produce a significant change in the strain of capsular-ligament tissue.
Assuntos
Articulação do Quadril , Ligamentos , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Cadáver , Fenômenos BiomecânicosRESUMO
BACKGROUND: Entrapment of the median nerve at the pronator teres muscle can contribute to symptoms in the forearm and wrist. The pronator teres is also involved in patterns of spasticity observed in people who had suffered a stroke. Research on treatment efficacy with dry needling is scarce. OBJECTIVE: To determine if a solid filiform needle safely penetrates the pronator teres muscle during the clinical application of dry needling. DESIGN: A cadaveric descriptive study. METHODS: Needle insertion of the pronator teres was conducted in ten cryopreserved forearms with a 30 ×0.32 mm filiform needle. With the forearm supinated, the needle was inserted 3 cm distal to the mid-point between the biceps tendon insertion and the medial epicondyle. The needle was advanced in a cranial and medial direction to a depth clinically judged to be in the pronator teres muscle. Safety was assessed by measuring the distance from the needle to the surrounding neurovascular bundles. RESULTS: Accurate needle penetration of the pronator teres was observed in 100% of the specimens (mean needle penetration: 16.7 ± 4.3 mm, 95% confidence interval [CI] 13.6 to 19.7 mm). No neurovascular bundles were pierced in any of the specimen's forearms. The distances from the tip of the needle to the surrounding neurovascular bundles were 16.4 ± 3.9 mm (95% CI 13.6 to 19.2 mm) to the ulnar nerve (A), 9.0 ± 2.2 mm (95% CI 7.3 to 19.5 mm) to the median nerve (B), and 12.8 ± 4.0 mm (95% CI 10.0 to 15.7 mm) to brachial artery (C). CONCLUSIONS: The results from this cadaveric study support the assumption that needling of the pronator teres using described anatomical landmarks can be accurately and safely conducted by an experienced clinician.
Assuntos
Agulhamento Seco , Antebraço , Cadáver , Cotovelo , Humanos , Músculo EsqueléticoRESUMO
OBJECTIVE: To analyze the effectiveness of the blood flow restriction training in improving muscle strength and physical performance in older adults. DATA SOURCES: A systematic review and meta-analysis of randomized controlled trials was conducted. The Cochrane Library, PubMed, Web of Sciences, PEDro, Scopus, and ScienceDirect databases were systematically searched. STUDY SELECTION: Articles were included if participants were 60 years or older and were considered healthy. DATA EXTRACTION: The search strategy found a total of 363 studies. Finally, 10 articles were included in the systematic review, with a total of 278 healthy older adults analyzed. DATA SYNTHESIS: The main results of the meta-analysis showed a statistical difference of muscle strength in favor of blood flow restriction training when compared with conventional training and no statistical differences when compared with high-intensity resistance training. Physical performance showed a nonstatistical difference between the blood flow restriction training, conventional training, and no training groups. CONCLUSIONS: Blood flow restriction training is an interesting alternative to high-intensity strength training for improving muscle strength in older individuals who cannot perform high-load exercises.
Assuntos
Terapia de Restrição de Fluxo Sanguíneo , Treinamento Resistido , Idoso , Exercício Físico/fisiologia , Humanos , Força Muscular/fisiologia , Desempenho Físico Funcional , Treinamento Resistido/métodosRESUMO
BACKGROUND: Evidence suggests that tibialis posterior muscle plays an important role in equinovarus foot deformity in patients who had suffered a stroke and it is one of the most frequently injected lower-extremity muscles for the management of spasticity. Our aim was to assess if a needle accurately and safely penetrates the tibialis posterior muscle during the application of dry needling. METHODS : We conducted a cadaveric descriptive study. Needling insertion of the tibialis posterior was conducted in 11 cryopreserved cadavers with a 70 mm needle. The needle was inserted using two common approaches, at midpoint (posterior/medial approach) and at upper third (anterior approach) of the leg towards the tibialis posterior. The needle was advanced into the tibialis posterior based upon clinician judgement. Cross-sectional anatomical dissections were photographed and analyzed by photometry. Safety was assessed by calculating the distances from the tip and the path of the needle to proximate neurovascular structures. RESULTS: Accurate needle penetration of the tibialis posterior muscle was observed in all cadavers with both approaches. In general, distances from the needle to the neurovascular bundles were larger with the posterior/medial approach than with the anterior approach, reaching statistically significance for needle tip to nerve (mean difference: 0.6 cm, 95%CI 0.35 to 0.85 cm) and vascular bundle (mean difference: 0.55 cm, 95%CI 0.3 to 0.8 cm) distances (P < 0.001) and needle path to vascular bundle distance (difference: 0.25 cm, 95%CI 0.1 to 0.4 cm, P = 0.045). Age and gender did not influence the main results. CONCLUSIONS: This cadaveric study suggests that needling of the tibialis posterior muscle can be accurately and safely conducted. Safety seems to be larger with the posterior/medial approach when compared with the anterior approach.
Assuntos
Agulhamento Seco , Perna (Membro) , Cadáver , Estudos Transversais , Humanos , Músculo EsqueléticoRESUMO
AIM OF THE STUDY: Systematic review and meta-analysis to assess the effectiveness of manual therapy in improving carpal tunnel syndrome (CTS) symptoms, physical function, and nerve conduction studies. METHOD: MEDLINE, Web of Science, SCOPUS, Cochrane Library, TRIP database, and PEDro databases were searched from the inception to September 2021. PICO search strategy was used to identify randomized controlled trials applying manual therapy on patients with CTS. Eligible studies and data extraction were conducted independently by two reviewers. Methodology quality and risk of bias were assessed by PEDro scale. Outcomes assessed were pain intensity, physical function, and nerve conduction studies. RESULTS: Eighty-one potential studies were identified and six studies involving 401 patients were finally included. Pain intensity immediately after treatment showed a pooled standard mean difference (SMD) of - 2.13 with 95% confidence interval (CI) (- 2.39, - 1.86). Physical function with Boston Carpal Tunnel Syndrome Questionnaire (BCTS-Q) showed a pooled SMD of - 1.67 with 95% CI (- 1.92, - 1.43) on symptoms severity, and a SMD of - 0.89 with 95% CI (- 1.08, - 0.70) on functional status. Nerve conduction studies showed a SMD of - 0.19 with 95% CI (- 0.40, - 0.02) on motor conduction and a SMD of - 1.15 with 95% CI (- 1.36, - 0.93) on sensory conduction. CONCLUSIONS: This study highlights the effectiveness of manual therapy techniques based on soft tissue and neurodynamic mobilizations, in isolation, on pain, physical function, and nerve conduction studies in patients with CTS.
Assuntos
Síndrome do Túnel Carpal , Manipulações Musculoesqueléticas , Síndrome do Túnel Carpal/terapia , Humanos , Manipulações Musculoesqueléticas/métodos , Condução Nervosa/fisiologia , Dor , Medição da Dor , Resultado do TratamentoRESUMO
OBJECTIVE: The purpose of this study was to evaluate changes in neuromuscular function, pain perception, and basic physical properties in latent myofascial trigger points (TrPs) after a single treatment session of ischemic compression in the gastrocnemius muscle. METHODS: A randomized within-participant clinical trial with a blinded assessor was conducted. Twenty-nine asymptomatic volunteers with latent gastrocnemius-muscle TrPs were bilaterally explored. Each extremity was randomly assigned to the control group (no treatment) or the experimental group (90 seconds of ischemic compression over each TrP). Neuromuscular function of the gastrocnemius muscle was assessed using a MyotonPro. Muscle flexibility was analyzed using the lunge test and the passive ankle range of motion. The strength was determined with a handheld dynamometer (MicroFET2). Pain perception was analyzed with a 0-to-10 numerical pain rating scale and determination of pressure pain thresholds over each latent TrP. RESULTS: The results revealed a reduction of 15.8% in pain perception and an increment of pressure tolerance of 9.9% without pain in the treatment group. Changes in muscle flexibility (active and passive) and most parameters for neuromuscular response (rigidity, elasticity, and relaxation) were also observed, but they were not significantly different between groups. The clinical effect sizes were moderate for pain perception (dâ¯=â¯0.69), pressure pain threshold (dâ¯=â¯0.78), muscle tone (dâ¯=â¯0.51), and elasticity (dâ¯=â¯0.54) in favor of the treated extremity. Small clinical effect sizes were observed for muscle physical outcomes. CONCLUSION: The present study shows that the use of a single session of ischemic compression for latent gastrocnemius-muscle TrPs improved some sensory outcomes. The effects on ankle range of motion and neuromuscular responses were inconclusive.
Assuntos
Síndromes da Dor Miofascial , Pontos-Gatilho , Humanos , Síndromes da Dor Miofascial/terapia , Músculo Esquelético , Limiar da Dor/fisiologia , Amplitude de Movimento Articular/fisiologiaRESUMO
Background and Objectives: Falls are a common and serious threat to the health and independence of older adults. The decrease in functional capacity during aging means an increased risk of falls. To date, it is not known whether there is a relationship between balance and functional tests. The aim of the study was to evaluate the correlation between eyes-open and eyes-closed static balance with different functional tests. Materials and Methods: A correlation study was designed with 52 healthy subjects over 65 years of age. Results: Regarding the open eyes stabilometric parameters, significant correlations observed between the surface and the functional tests were weak in all cases. The correlations observed between length and the functional tests performed were moderate, except for that of the Timed Up and Go test (TUG) which was weak. No significant correlation between TUG and surface was found. Regarding the closed eyes stabilometric parameters, statistically significant moderate correlations were found between the surface and the Short Physical Performance Battery (SPPB) and the Five Times Sit to Stand test (5XSST). In the case of the length with eyes closed, a statistically significant moderate correlation (rho = 0.40-0.69) was found with the SPPB and 5XSST variables, and weak correlations with the 4 m Walk Speed test (4WS) and TUG variables. Conclusions: There is a mild to moderate correlation between some functional tests and stabilometric parameters in adults over 65 years old.
Assuntos
Avaliação Geriátrica , Equilíbrio Postural , Acidentes por Quedas/prevenção & controle , Idoso , Humanos , Desempenho Físico Funcional , Estudos de Tempo e MovimentoRESUMO
Background and Objectives: Glenohumeral axial distraction mobilization (GADM) is a usual mobilization technique for patients with shoulder dysfunctions. The effect of scapular fixation on the movement of the scapula and the humeral head during GADM is unknown. To analyze the caudal movement of the humeral head and the rotatory movement of the scapula when applying three different intensities of GADM force with or without scapular fixation. Materials and Methods: Fifteen healthy subjects (mean age 28 ± 9 years; 73.3% male) participated in the study (twenty-eight upper limbs). Low-, medium- and high-force GADM in open-packed position were applied in scapular fixation and non-fixation conditions. The caudal movement of humeral head was evaluated by ultrasound measurements. The scapular rotatory movement was assessed with a universal goniometer. The magnitude of force applied during GADM and the region (glenohumeral joint, shoulder girdle, neck or nowhere) where subjects felt the effect of GADM mobilization were also recorded. Results: A greater caudal movement of the humeral head was observed in the non-scapular fixation condition at the three grades of GADM (p < 0.008). The rotatory movement of the scapula in the scapular fixation condition was practically insignificant (0.05−0.75°). The high-force GADM rotated scapula 18.6° in non-scapular fixation condition. Subjects reported a greater feeling of effect of the techniques in the glenohumeral joint with scapular fixation compared with non-scapular fixation. Conclusions: The caudal movement of the humeral head and the scapular movement were significantly greater in non-scapular fixation condition than in scapular fixation condition for the three magnitudes of GADM force.
Assuntos
Cabeça do Úmero , Articulação do Ombro , Adulto , Fenômenos Biomecânicos , Feminino , Movimentos da Cabeça , Humanos , Cabeça do Úmero/cirurgia , Masculino , Escápula , Adulto JovemRESUMO
BACKGROUND: Capacitive-resistive electric transfer therapy is an interesting rehabilitation treatment to use in musculoskeletal injuries. The purpose is to analyze the temperature change and current flow in superficial and deep biceps femoris and quadriceps tissues when applying different protocols of capacitive-resistive electric transfer therapy. METHODS: Five cryopreserved cadavers (10 legs) were included in this study. Four interventions (high/low power) were performed for 5 minutes. Dynamic movements were performed to the biceps femoris and quadriceps. Superficial, middle, and deep temperature were recorded at 1-minute intervals and 5 minutes after the treatment using invasive temperature meters placed with ultrasound guidance. RESULTS: Low-power applications have generated a very low thermal effect and an important current flow. The high-power capacitive application achieves a greater increase in superficial temperature compared with low power (P < .001). The high-power resistive application recorded a greater increase in superficial, middle, and deep temperatures with a greater current flow compared with the other applications (P < .001). CONCLUSION: This study could serve as basic science data to justify the acceleration of the processes of muscle recovery, improving cell proliferation without increasing the temperature in acute muscle injuries and increasing the temperature and viscoelasticity of the tissues in chronic processes with this therapy.
Assuntos
Terapia por Estimulação Elétrica , Músculos Isquiossurais , Cadáver , Terapia por Estimulação Elétrica/métodos , Humanos , Músculo Esquelético/fisiologia , Músculo QuadrícepsRESUMO
OBJECTIVE: Dry needling is commonly used for the management of plantar fasciitis. This meta-analysis evaluated the effects of dry needling over trigger points associated with plantar heel pain on pain intensity and related disability or function. METHODS: Electronic databases were searched for randomized controlled trials in which at least one group received dry needling, not acupuncture, for trigger points associated with plantar heel pain and in which outcomes were collected on pain intensity and related disability. The risk of bias was assessed with the Cochrane Risk of Bias tool, methodological quality was assessed with the Physiotherapy Evidence Database (PEDro) score, and the level of evidence is reported according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. Between-groups mean differences (MD) and standardized mean differences (SMD) were calculated. RESULTS: The search identified 297 publications, with six trials eligible for inclusion. The meta-analysis found low-quality evidence that trigger point dry needling reduces pain intensity in the short term (MD -1.70 points, 95% confidence interval [CI] -2.80 to -0.60; SMD -1.28, 95% CI -2.11 to -0.44) and moderate-quality evidence that it improves pain intensity (MD -1.77 points, 95% CI -2.44 to -1.11; SMD -1.45, 95% CI -2.19 to -0.70) and related disability (SMD -1.75, 95% CI -2.22 to -1.28) in the long term, as compared with a comparison group. The risk of bias of the trials was generally low, but the heterogeneity of the results downgraded the level of evidence. DISCUSSION: Moderate- to low-quality evidence suggests a positive effect of trigger point dry needling for improving pain intensity and pain-related disability in the short term and long term, respectively, in patients with plantar heel pain of musculoskeletal origin. The present results should be considered with caution because of the small number of trials.
Assuntos
Agulhamento Seco , Fasciíte Plantar , Fasciíte Plantar/terapia , Calcanhar , Humanos , Dor , Medição da DorRESUMO
OBJECTIVE: To evaluate the effects of muscle dry needling alone or combined with other interventions on post-stroke spasticity (muscle tone), related pain, motor function, and pressure sensitivity. DATABASES AND DATA TREATMENT: Electronic databases were searched for randomized controlled trials including post-stroke patients where at least one group received dry needling and outcomes were collected on spasticity and related pain. Secondary outcomes included motor function and pressure pain sensitivity. Data were extracted by two reviewers. The risk of bias was assessed with the Cochrane Risk of Bias tool, methodological quality was assessed with the Physiotherapy Evidence Database score, and the quality of evidence was assessed by the Grading of Recommendations Assessment, Development, and Evaluation approach. Between-groups mean differences (MDs) and standardized mean differences (SMDs) were calculated. RESULTS: Seven studies (three within the lower extremity, four in the upper extremity) were included. The meta-analysis found significantly large effect sizes of dry needling for reducing spasticity (SMD: -1.01, 95%confidence interval [CI] -1.68 to -0.34), post-stroke pain (SMD -1.01, 95%CI -1.73 to -0.30), and pressure pain sensitivity (SMD 1.21, 95% CI: 0.62 to 1.80) as compared with a comparative group at short-term follow-up. The effect on spasticity was found mainly in the lower extremity (MD -1.05, 95% CI: -1.32 to -0.78) at short-term follow-up. No effect on spasticity was seen at 4 weeks. No significant effect on motor function (SMD 0.16, 95% CI: -0.13 to 0.44) was observed. The risk of bias was generally low, but the imprecision of the results downgraded the level of evidence. CONCLUSION: Moderate evidence suggests a positive effect of dry needling on spasticity (muscle tone) in the lower extremity in post-stroke patients. The effects on related pain and motor function are inconclusive.
Assuntos
Agulhamento Seco , Acidente Vascular Cerebral , Humanos , Limiar da Dor , Modalidades de Fisioterapia , Acidente Vascular Cerebral/complicações , Extremidade SuperiorRESUMO
BACKGROUND: The popliteus muscle attaches posteriorly to the joint capsule of the knee. Although it is an important rotational stabiliser and has been implicated in various knee pathologies, research on its treatment with dry needling is scarce. OBJECTIVE: To determine if a needle accurately and safely penetrates the popliteus muscle during the clinical application of dry needling. METHODS: A cadaveric descriptive study was conducted. Needling insertion of the popliteus muscle was conducted in 11 cryopreserved cadavers with a 50-mm needle. The needle was inserted at upper third of the posterior part of the tibia closest to the knee towards the popliteus. The needle was advanced into the muscle based upon clinician judgement. Cross-sectional anatomical dissections were photographed and analysed by photometry. Safety of the intervention was assessed by calculating the distance from the tip of the needle to the proximate neurovascular structures. RESULTS: Accurate needle penetration of the popliteus muscle was observed in 10 out of 11 (91%) of the cadavers (mean needle penetration: 25.7 ± 6.7mm, 95% CI 21.3-30.3 mm). The distances from the tip of the needle were 17±6mm (95% CI 13-21 mm) to the tibial nerve and 15 ± 0.7mm (95% CI 10-20 mm) to the popliteus vascular bundle. CONCLUSION: The results from this cadaveric study support the notion that needling of the popliteus can be accurately and safely conducted by an experienced clinician. Future studies investigating the clinical effectiveness of these interventions are needed.
Assuntos
Agulhamento Seco , Cadáver , Estudos Transversais , Humanos , Articulação do Joelho , Músculo EsqueléticoRESUMO
OBJECTIVE: To evaluate the effect of adding an Upper Cervical Translatoric Mobilization (UCTM) or an Inhibitory Suboccipital Technique (IST) to a physiotherapy treatment in the symptomatology and function of mechanical chronic neck pain patients. DESIGN: Randomized controlled trial. SETTING: Primary Care Center in Cornellà, Spain. SUBJECTS: 78 patients (64 women), with mean age (SD) of 59.96 (13.30) years with mechanical chronic neck pain were divided in three groups: control, IST and UCTM groups. INTERVENTIONS: All groups received 15 physiotherapy sessions for three weeks. The UCTM and IST groups added 5 minutes of the assigned technique during six sessions. MAIN MEASURES: Neck disability index (NDI) and numeric pain rating scale (NPRS) for neck pain were measured baseline, three-weeks and 15-weeks follow-up. RESULTS: NDI (SD) at baseline, three-weeks and 15-weeks were 11.62 (7.08), 9.65 (6.25), 7.58 (5.64) for the control group, 14.38 (6.92), 8.50 (6.11), 7.12 (4.98) for the IST group and 13.19(7.23), 5.35(6.10), 4.35(2.76) for the UCTM group. NPRS (SD) at baseline, three-weeks and 15-weeks were 58.69 (19.46), 45.19 (23.43), 44.58 (24.08) for the control group; 64.08 (19.26), 42.19 (19.69), 34 (21.14) for the IST group; and 67.65 (20.65), 36.23 (20.10), 39.85 (25.44) for the UCTM group. CONCLUSIONS: Compared with no treatment, both forms of mobilization were associated with reduced disability at three weeks, and UCTM remained better than control at 15 weeks; there were no significant differences between the two mobilization groups. TRIAL REGISTRATION: This study was registered in Clinicaltrials.gov (NCT02832232).
Assuntos
Dor Crônica/reabilitação , Manipulações Musculoesqueléticas , Cervicalgia/reabilitação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Atenção Primária à Saúde , Amplitude de Movimento Articular , Espanha , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode. METHODS: A cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5 min each by a diathermy "T-Plus" device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. RESULTS: A statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P< 0.035). All the applications showed a 5 min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% ± 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% ± 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% ± 22.96 at 5-min at the superficial level, and 32% ± 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% ± 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level. CONCLUSION: The shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area.
Assuntos
Articulação do Ombro , Ombro , Fenômenos Biomecânicos , Cadáver , Estudos Transversais , Eletrodos , Humanos , TemperaturaRESUMO
BACKGROUND: Calf muscle strain and Achilles tendon injuries are common in many sports. For the treatment of muscular and tendinous injuries, one of the newer approaches in sports medicine is capacitive-resistive electric transfer therapy. Our objective was to analyze this in vitro, using invasive temperature measurements in cadaveric specimens. METHODS: A cross-sectional study designed with five fresh frozen cadavers (10 legs) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) was performed for 5 min each by a diathermy "T-Plus" device. Achilles tendon, musculotendinous junction and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. RESULTS: With the low-power capacitive protocol, at 5 min, there was a 25.21% increase in superficial temperature, a 17.50% increase in Achilles tendon temperature and an 11.27% increase in musculotendinous junction temperature, with a current flow of 0.039 A ± 0.02. With the low-power resistive protocol, there was a 1.14% increase in superficial temperature, a 28.13% increase in Achilles tendon temperature and an 11.67% increase in musculotendinous junction temperature at 5 min, with a current flow of 0.063 A ± 0.02. With the high-power capacitive protocol there was an 88.52% increase in superficial temperature, a 53.35% increase in Achilles tendon temperature and a 39.30% increase in musculotendinous junction temperature at 5 min, with a current flow of 0.095 A ± 0.03. With the high-power resistive protocol, there was a 21.34% increase in superficial temperature, a 109.70% increase in Achilles tendon temperature and an 81.49% increase in musculotendinous junction temperature at 5 min, with a current flow of 0.120 A ± 0.03. CONCLUSION: The low-power protocols resulted in only a very slight thermal effect at the Achilles tendon and musculotendinous junction, but current flow was observed. The high-power protocols resulted in a greater temperature increase at the Achilles tendon and musculotendinous junction and a greater current flow than the low-power protocols. The high-power resistive protocol gave the greatest increase in Achilles tendon and musculotendinous junction temperature. Capacitive treatments (low- and high-power) achieved a greater increase in superficial temperature.
Assuntos
Tendão do Calcâneo/lesões , Tendão do Calcâneo/patologia , Capacitância Elétrica/uso terapêutico , Terapia por Estimulação Elétrica/métodos , Temperatura Alta/uso terapêutico , Músculo Esquelético/patologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Tendões/patologia , Traumatismos dos Tendões/terapiaRESUMO
The objective of this work was to make an intercultural adaptation and provide a Spanish translation and psychometric evaluation of the original English version of the Healthcare Professional Knowledge of Radiation Protection (HPKRP) scale. The Spanish translation was carried out following international guidelines for the process of cross-cultural adaptation of self-report measures. A cross-sectional design study was carried out. One hundred and thirty-eight nurses from four different hospitals in Barcelona (Spain) completed the Spanish version of the scale. The total score of the scale was calculated. The Pearson correlation coefficient (PCC) was used to evaluate a possible correlation between score and years of experience. A t-test for independent samples was used to evaluate significant differences between different groups. Cronbach's alpha, the corrected item-total correlation coefficient and the test-retest coefficient were used to determine internal consistency. The exploratory factor and parallel analysis were also calculated. All statistical tests were carried out with a level of significance α = 0.05. The mean scale score was poor among Spanish nurses. The PCC between total score and years of experience showed a non-significant correlation (p > 0.05). No differences were found between nurses who worked in radiation-exposed units and those who worked in units without radiation exposure (p > 0.05). A Cronbach α of 0.98 was obtained for the items of the scale. The corrected item-total correlation range was 0.5-0.8. The test-retest correlation coefficient was 0.9. The exploratory analysis factor showed a single factorial structure which explained 60.86% of the variance. The new scale translated into Spanish (Sp-HPKRP) could be used to evaluate the degree of knowledge about radiological protection.
Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Recursos Humanos de Enfermagem Hospitalar , Proteção Radiológica/normas , Adulto , Feminino , Humanos , Masculino , Psicometria , Reprodutibilidade dos Testes , Espanha , TraduçõesRESUMO
The tarsal tunnel is a fibrous osseous conduit for the tibial nerve and associated tendons. It is mechanically dynamic, and foot and ankle movements appear to move and change tunnel shape. However, the effect of foot and ankle movements is not clear. The aim of this study was to measure tarsal tunnel dimensions in anatomical position of the foot and ankle and quantify its changes at different positions in cadavers. A cross-sectional study with a total of 16 cryopreserved lower extremities from cadaveric specimens were used. The foot was cut using an anatomical saw at the level of the tarsal tunnel. Measurements of the cross-sectional area (CSA), transverse diameter (TD), longitudinal diameter (LD) were taken in anatomical position and during foot and ankle movements. All the tarsal tunnel measurements were significantly modified by ankle plantar flexion (p < .05). The CSA increased by 68.97 mm2 (p < .001), the TD increased by 1.40 mm (p < .002) and the LD increased by 2.55 mm (p < .007). The TD was also significantly modified by the inversion position of the ankle, showing an increase of 0.84 mm (p < .004). The rest of the ankle positions did not produce significant changes in tarsal tunnel measurements. Foot and ankle plantar flexion position produce and increase in the CSA and the TD of the tarsal tunnel at its distal end in cadavers. This could suggest a reduction in tarsal tunnel pressure during plantar flexion.
Assuntos
Tornozelo , Síndrome do Túnel do Tarso , Articulação do Tornozelo , Estudos Transversais , Humanos , Síndrome do Túnel do Tarso/diagnóstico por imagem , Tendões , Nervo TibialRESUMO
The fascia is an undifferentiated mesenchymal tissue related to the peripheral nerves. Both can be identified by ultrasound, which is useful when performing peripheral nerve blocks. However, there is no unanimity about the approaching point of each nerve, nor is there a consensus on how to name the appropriate infiltration zone, although the paraneural zone is frequently mentioned. The aims of this study were to determine if ultrasound is accurate for identifying the fascial planes and the paraneural space of the nerves in the knee, infiltrating them, and achieving a correct anatomical diffusion, as well as for establishing access routes to avoid intraneural infiltration. The study was performed in 16 cryopreserved lower extremities of the dissection room of the Faculty of Medicine and Health Sciences, University of Barcelona. Nerves of the knee were injected with colorant guided by ultrasound after they were visualized. Correct location of the nerves by ultrasound was achieved in 98.75% of the cases, correct visualization of the needle by ultrasound in 82.5%, the hypoechogenic image around the nerve after infiltration in 82.5%, and a correct paraneural infiltration in 76.25% of cases. With these results, we can conclude that high-definition ultrasound enables location of the peripheral nerves and adjacent structures as well as the fasciae that surround them, and therefore allows performance of infiltrations in the paraneural spaces.