Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 33(3): 286-294, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34798292

RESUMO

PURPOSE: To assess ischemic adverse events following particle embolization when used as a second-line embolic to coil embolization for the treatment of acute lower gastrointestinal bleeding (LGIB). MATERIALS AND METHODS: The single-institution retrospective study examined 154 procedures where embolization was attempted for LGIB. In 122 patients (64 men; mean age, 69.9 years), embolization was successfully performed using microcoils in 73 procedures, particles in 34 procedures, and both microcoils and particles in 27 procedures. Particles were used as second-line only when coil embolization was infeasible or inadequate. Technical success was defined as angiographic cessation of active extravasation after embolization. Clinical success was defined as the absence of recurrent bleeding within 30 days of embolization. RESULTS: Technical success for embolization of LGIB was achieved in 87% of the cases (134/154); clinical success rate was 76.1% (102/134) among the technically successful cases. Clinical success was 82.2% (60/73) for coils alone and 68.9% (42/61) for particles with or without coils. Severe adverse events involving embolization-induced bowel ischemia occurred in 3 of 56 (5.3%) patients who underwent particle embolization with or without coils versus zero of 66 patients when coils alone were used (P = .09). In patients who had colonoscopy or bowel resection within 2 weeks of embolization, ischemic findings attributable to the procedure were found in 3 of the 15 who underwent embolization with coils alone versus 8 of 18 who underwent embolization with particles with or without coils (P = .27). CONCLUSIONS: Particle embolization for the treatment of LGIB as second-line to coil embolization was associated with a 68.9% clinical success rate and a 5.3% rate of ischemia-related adverse events.


Assuntos
Embolização Terapêutica , Hemorragia Gastrointestinal , Idoso , Angiografia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
2.
Pediatr Blood Cancer ; 69 Suppl 3: e29321, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-36070210

RESUMO

Vascular anomalies are a group of disorders divided into two distinct subtypes: vascular tumors and vascular malformations. Vascular tumors are proliferative in nature, while malformations are nonproliferative. Simple, localized vascular malformations refer to a group of malformations that are localized to a single area of involvement. These simple malformations include capillary, lymphatic, venous, and arteriovenous malformations. The pediatric hematologists and oncologists are becoming increasingly involved in the diagnosis and management of these disorders. This review presents four cases as a means to discuss the diagnosis, clinical and imaging features, and management strategies of simple, localized vascular malformations.


Assuntos
Hemangioma , Malformações Vasculares , Neoplasias Vasculares , Criança , Hemangioma/patologia , Humanos , Malformações Vasculares/diagnóstico , Malformações Vasculares/patologia , Malformações Vasculares/terapia , Neoplasias Vasculares/diagnóstico , Neoplasias Vasculares/terapia
3.
J Magn Reson Imaging ; 53(2): 374-380, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32048438

RESUMO

Magnetic resonance lymphangiography (MRL) is a noninvasive imaging technique that can be used in the management of lymphatic disorders to delineate the central lymphatic system for treatment planning. This article reviews the MRL technique, its advantages, limitations, indications, and impact on patient management. Level of Evidence 5 Technical Efficacy Stage 3 J. MAGN. RESON. IMAGING 2021;53:374-380.


Assuntos
Meios de Contraste , Linfografia , Humanos , Sistema Linfático/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
4.
J Vasc Interv Radiol ; 32(9): 1310-1318.e2, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34058351

RESUMO

PURPOSE: To report initial clinical experience with intravascular ultrasound (US)-guided transvenous biopsy (TVB) for perivascular target lesions in the abdomen and pelvis using side-viewing phased-array intracardiac echocardiography catheters. MATERIALS AND METHODS: In this single-institution, retrospective study, 48 patients underwent 50 intravascular US-guided TVB procedures for targets close to the inferior vena cava or iliac veins deemed difficult to access by conventional percutaneous needle biopsy (PNB). In all procedures, side-viewing phased-array intracardiac echocardiography intravascular US catheters and transjugular liver biopsy sets were inserted through separate jugular or femoral vein access sheaths, and 18-gauge core needle biopsy specimens were obtained under real-time intravascular US guidance. Diagnostic yield, diagnostic accuracy, and complications were analyzed. RESULTS: Intravascular US-guided TVB was diagnostic of malignancy in 40 of 50 procedures for a diagnostic yield of 80%. There were 5 procedures in which biopsy was correctly negative for malignancy, with a per-procedure diagnostic accuracy of 90% (45/50). Among the 5 false negatives, 2 patients underwent repeat intravascular US-guided TVB, which was diagnostic of malignancy for a per-patient diagnostic accuracy of 94% (45/48). There were 1 (2%) mild, 2 (4%) moderate, and 1 (2%) severe adverse events, with 1 moderate severity adverse event (venous thrombosis) directly attributable to the intravascular US-guided TVB technique. CONCLUSIONS: Intravascular US-guided TVB performed on difficult-to-approach perivascular targets in the abdomen and pelvis resulted in a high diagnostic accuracy, similar to accepted thresholds for PNB. Complication rates may be slightly higher but should be weighed relative to the risks of difficult PNB, surgical biopsy, or clinical management without biopsy.


Assuntos
Biópsia Guiada por Imagem , Pelve , Abdome , Biópsia com Agulha de Grande Calibre/efeitos adversos , Humanos , Estudos Retrospectivos , Ultrassonografia de Intervenção
5.
J Vasc Interv Radiol ; 32(5): 762.e1-762.e7, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33610432

RESUMO

Recognizing the increasing importance of lymphatic interventions, the Society of Interventional Radiology Foundation brought together a multidisciplinary group of key opinion leaders in lymphatic medicine to define the priorities in lymphatic research. On February 21, 2020, SIRF convened a multidisciplinary Research Consensus Panel (RCP) of experts in the lymphatic field. During the meeting, the panel and audience discussed potential future research priorities. The panelists ranked the discussed research priorities based on clinical relevance, overall impact, and technical feasibility. The following research topics were prioritized by RCP: lymphatic decompression in patients with congestive heart failure, detoxification of thoracic duct lymph in acute illness, development of newer agents for lymphatic imaging, characterization of organ-based lymph composition, and development of lymphatic interventions to treat ascites in liver cirrhosis. The RCP priorities underscored that the lymphatic system plays an important role not only in the intrinsic lymphatic diseases but in conditions that traditionally are not considered to be lymphatic such as congestive heart failure, liver cirrhosis, and critical illness. The advancement of the research in these areas will lead the field of lymphatic interventions to the next level.


Assuntos
Pesquisa Biomédica/normas , Doenças Linfáticas/terapia , Sistema Linfático , Pesquisa/normas , Animais , Consenso , Humanos , Pesquisa Interdisciplinar/normas , Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/fisiopatologia , Sistema Linfático/diagnóstico por imagem , Sistema Linfático/fisiopatologia
6.
J Vasc Interv Radiol ; 32(2): 277-281, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33160829

RESUMO

Patients with a gastrojejunal anastomosis pose challenging anatomy for percutaneous gastrojejunostomy (GJ)-tube placement. A retrospective review of 24 patients (mean age 67.8 years, 13 males) with GJ anastomoses who underwent attempted GJ tube placement revealed infeasible placement in 6 patients (25%) due to an inadequate window for puncture. When a gastric puncture was achieved, GJ tube insertion was technically successful in 83% (15/18) of attempts, resulting in an overall technical success rate of 63% (15/24). The most common tube-related complication was the migration of the jejunal limb into the stomach, which occurred in 40% (6/15) of successful cases. No major procedure related complications were encountered.


Assuntos
Nutrição Enteral/instrumentação , Derivação Gástrica/efeitos adversos , Gastroparesia/terapia , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/efeitos adversos , Nutrição Enteral/efeitos adversos , Feminino , Esvaziamento Gástrico , Gastroparesia/diagnóstico por imagem , Gastroparesia/etiologia , Gastroparesia/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Radiografia Intervencionista , Fatores de Tempo , Resultado do Tratamento
7.
J Vasc Interv Radiol ; 31(2): 243-250, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31706885

RESUMO

PURPOSE: To compare outcomes after conversion of arteriovenous (AV) access to Hemodialysis Reliable Outflow (HeRO) graft vs stent deployment in patients with arm swelling owing to ipsilateral central vein stenosis. MATERIALS AND METHODS: This single-center retrospective study comprised 48 patients (19 men, mean age 58 y) with arm swelling ipsilateral to AV access and central vein stenosis over a 13-year period who had clinical follow-up and without prior central stents. Twenty-one patients underwent placement of a HeRO graft with anastomosis of the HeRO graft to the existing graft or fistula, and 27 patients underwent central venous stent deployment. Symptomatic improvement in arm swelling and access patency rates after intervention were ascertained from medical records. RESULTS: Improvement in swelling within 1 month after HeRO conversion and stent deployment was found in 95% and 89%, respectively (P = .62). Swelling eventually recurred in 16 patients (59%) treated with stents compared with 1 patient (5%) who underwent HeRO conversion (P < .001). Primary access patency was statistically significantly longer after HeRO conversions than stent deployments, with 6- and 12-month primary patency rates of 89% and 72% vs 47% and 11% (P < .001). HeRO conversions also resulted in longer 6- and 12-month secondary access patency rates (95% and 95% vs 79% and 58%, P = .006). Mean number of interventions per 1,000 access days to maintain secondary patency was 2.7 for the HeRO group vs 6.3 for the stent group. CONCLUSIONS: Although stent deployment and HeRO graft conversion are effective for alleviating arm swelling in the short term in patients receiving hemodialysis with clinically significant arm swelling and functioning AV access, the HeRO graft has more durable results.


Assuntos
Angioplastia com Balão/instrumentação , Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Oclusão de Enxerto Vascular/cirurgia , Diálise Renal , Stents , Extremidade Superior/irrigação sanguínea , Angioplastia com Balão/efeitos adversos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
J Vasc Interv Radiol ; 31(3): 454-461, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32007408

RESUMO

PURPOSE: To compare early totally implantable central venous port catheter-related infection rates after inpatient vs outpatient placement and to determine whether the risk associated with inpatient placement is influenced by length of hospital stay. MATERIALS AND METHODS: In this single-institution retrospective study, 5,301 patients (3,618 women; mean age 57 y) underwent port placement by interventional radiologists between October 2004 and January 2018. The 30-day infection rate was compared between inpatients and outpatients using survival analysis. Among inpatients, the effect of time from admission to port placement and from placement to discharge was analyzed using a survival regression tree. RESULTS: The 30-day infection rate was 3.6% (95% confidence interval [CI] = 1.9%-6.1%) among 386 inpatients and 1.0% (95% CI = 0.7%-1.3%) among 4,915 outpatients (hazard ratio [HR] = 3.6, 95% CI = 2.0-6.6, P < .001). Inpatient placement was a significant risk factor after accounting for covariates in multivariate analysis (HR = 2.2, 95% CI = 1.0-4.7, P = .05) and controlling for demographic differences by propensity score matching (HR = 2.8, 95% CI = 1.0-7.8, P = .04). Infection rate was 11% (95% CI = 4.7%-22%) among 65 inpatients in whom time from admission to placement was ≥ 7 days, 5.1% (95% CI = 1.9%-11%) among 129 inpatients in whom admission to placement was < 7 days and time to discharge was > 3 days, and 0% (95% CI = 0%-2.1%) among 192 inpatients in whom admission to placement was < 7 days and time to discharge was ≤ 3 days (P < .001). CONCLUSIONS: Inpatient port placement was associated with a higher risk of early infection. However, a clinical decision tree based on shorter length of stay before and after placement may identify a subset of hospitalized patients not at increased risk for infection.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Tempo de Internação , Alta do Paciente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Relacionadas a Cateter/diagnóstico , Cateterismo Venoso Central/instrumentação , Árvores de Decisões , Feminino , Humanos , Pacientes Internados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
9.
J Vasc Interv Radiol ; 30(7): 1069-1074, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31133452

RESUMO

PURPOSE: To compare the safety and effectiveness of different-site port placement versus same-site port salvage in adult patients with occluded ports. MATERIALS AND METHODS: Ninety-five occluded subcutaneous infusion ports (ports) in 95 patients presenting between July 1, 2002, and June 30, 2017, were retrospectively reviewed: 48 (51%) different-site placements (replacements; same-day indwelling port removal and different-site new port placement) and 47 (49%) same-site salvages (salvages; 35 fibrin sheath strippings, 12 over-the-wire exchanges). Demographic information, indication for initial placement and replacement or salvage, procedural details, post-intervention primary catheter patency, and post-intervention port sequelae were recorded. Post-intervention primary catheter patency, and malfunction and infection rates were compared with Kaplan-Meier estimation and the log-rank test, and Fisher exact test, respectively. The association of patient risk factors and port patency was assessed with Cox regression. RESULTS: Median primary catheter patency after replacement was 254 days (interquartile range [IQR], 297) and after salvage was 391 days (IQR, 906) (P = .25). Within the salvage group, median primary catheter patency after stripping was 391 days (IQR, 658) and after exchange was 666 days (IQR, 1412) (P = .08). There was no statistical difference in malfunction (P = .12) and infection (P = .74) rates between the replaced and salvaged groups or in malfunction (P = .09) and infection (P = .1) rates between the exchanged and stripped subgroups. None of the patient or catheter characteristics assessed were significantly associated with primary catheter patency. CONCLUSIONS: There was no statistical difference between patency, malfunctions, or infections after replacement and salvage, or after stripping and exchange, so technique selection should be based on the patient's estimated lifetime venous access requirements, cost, and physician preference.


Assuntos
Obstrução do Cateter/etiologia , Cateteres de Demora/efeitos adversos , Remoção de Dispositivo , Terapia de Salvação , Dispositivos de Acesso Vascular/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Relacionadas a Cateter/etiologia , Remoção de Dispositivo/efeitos adversos , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Terapia de Salvação/efeitos adversos , Resultado do Tratamento , Adulto Jovem
11.
J Vasc Interv Radiol ; 30(2): 163-169, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30638914

RESUMO

PURPOSE: To determine whether proton pump inhibitor (PPI) use increases the rate of new or worsening hepatic encephalopathy (HE) after transjugular intrahepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS: In this retrospective study, 284 of 365 patients who underwent TIPS creation from January 1, 2005, to December 31, 2016, were analyzed (186 male, mean age 56 y, range 19-84 y). Dates of PPI use and dates of new or worsening HE, defined as hospitalization or escalation in outpatient medical management, were extracted from medical records. Mixed-effects negative binomial regression was used to test for an association between PPI usage and HE. RESULTS: After TIPS creation, among 168 patients on PPIs chronically, there were 235 episodes of new or worsening HE in 106,101 person-days (0.81/person-year). Among 55 patients never on PPIs, there were 37 episodes in 31,066 person-days (0.43/person-year). Among 61 patients intermittently taking PPIs, there were 78 episodes in 37,710 person-days while on PPIs (0.75/person-year) and 25 episodes in 35,678 person-days while off PPIs (0.26/person-year). In univariate regression, PPI usage was associated with a 3.34-fold increased rate of new or worsening HE (incidence rate ratio [IRR] 3.34; P < .001). In multivariate regression, older age (IRR 1.05; P < .001), male sex (IRR 1.58; P = .023), higher Model for End-Stage Liver Disease score (IRR 1.06; P = .015), previous HE or HE-preventive medication use (IRR 1.51; P = .029), and PPI use (IRR 3.19; P < .001) were significant risk factors. Higher PPI doses were associated with higher rates of HE (IRR 1.16 per 10 mg omeprazole equivalent; P = .046). CONCLUSIONS: PPI usage is associated with increased rates of new or worsening HE after TIPS creation.


Assuntos
Encefalopatia Hepática/induzido quimicamente , Cirrose Hepática/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Inibidores da Bomba de Prótons/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Encefalopatia Hepática/diagnóstico , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
J Vasc Interv Radiol ; 28(1): 111-116, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27836404

RESUMO

PURPOSE: To compare early outcomes of skin closure with octyl cyanoacrylate skin adhesive versus subcuticular suture closure. MATERIALS AND METHODS: Over a 7-month period, 109 subjects (28 men and 81 women; mean age, 58.6 y) scheduled to undergo single-lumen implantable venous port insertion for chemotherapy were randomly assigned to skin closure with either octyl cyanoacrylate skin adhesive or absorbable subcuticular suture after suturing the deep dermal layer. Subjects were followed for episodes of infection or dehiscence within 3 months of port implantation. At 3 months, photographs of the healed incision were obtained and reviewed by a plastic surgeon in a blinded fashion who rated cosmetic scar appearance based on a validated 10-point cosmesis score. RESULTS: Of subjects, 54 were randomly assigned to skin adhesive, and 55 were randomly assigned to subcuticular suture. No subjects had incision dehiscence. Infection rates at 3 months were similar between groups (2.1% vs 4.0%; P = 1.0). The mean cosmesis scores were 4.40 for skin adhesive and 4.46 for subcuticular suture (P = .898). The superficial skin closure time was 8.6 minutes for suture versus 1.4 minutes for skin adhesive (P < .001). CONCLUSIONS: Scar cosmesis and patient outcomes did not significantly vary between skin adhesive versus subcuticular suture, although skin closure time was significantly less with skin adhesive.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Cianoacrilatos/uso terapêutico , Técnicas de Sutura , Adesivos Teciduais/uso terapêutico , Infecções Relacionadas a Cateter/microbiologia , Cateterismo Venoso Central/efeitos adversos , Cicatriz/etiologia , Cianoacrilatos/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina , Estudos Prospectivos , Deiscência da Ferida Operatória/etiologia , Infecção da Ferida Cirúrgica/microbiologia , Técnicas de Sutura/efeitos adversos , Fatores de Tempo , Adesivos Teciduais/efeitos adversos , Resultado do Tratamento , Cicatrização
14.
Pediatr Surg Int ; 33(2): 149-154, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27878447

RESUMO

PURPOSE: This study aimed to define morbidities and costs related to modern-day medical care for children with vascular anomalies. METHODS: We reviewed the 2003-2009 Kids' Inpatient Database for pediatric patients (age < 21 years) hospitalized with hemangioma, arteriovenous malformation (AVM), or lymphatic malformation (LM). Patient characteristics, hospital complications, and hospital charges were compared by vascular anomaly type. Multivariable linear regression modeling was used to determine predictors of increasing hospital costs for patients with AVMs. RESULTS: In total, 7485 pediatric inpatients with vascular anomalies were identified. Frequently associated complications included chronic anemia (4.0%), sepsis (4.6%), and hypertension (2.4%). Children with AVM had the highest rate of in-hospital mortality, compared to those with hemangiomas or LM (1.0% vs. 0.1% vs. 0.3%, p < 0.001). AVMs were also associated with the highest median hospital charge, more than twice the cost for hemangiomas or LM ($45,875 vs. $18,909 vs. $18,919; p < 0.001). CONCLUSIONS: There is a significant rate of morbidity in children with vascular anomalies, most often from blood loss and infection. The greater cost of AVM care may be related to the higher mortality rate, associated complications, and complexity of procedures required treating them. Cost-effective management of vascular anomalies should target prevention and the early recognition of both chronic comorbidities and acute complications.


Assuntos
Custos de Cuidados de Saúde/estatística & dados numéricos , Malformações Vasculares/economia , Malformações Vasculares/epidemiologia , Adolescente , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Mortalidade Hospitalar , Humanos , Lactente , Pacientes Internados/estatística & dados numéricos , Masculino , Morbidade , Pediatria/economia , Pediatria/métodos , Pediatria/estatística & dados numéricos , Estudos Retrospectivos , Malformações Vasculares/terapia , Adulto Jovem
15.
J Vasc Interv Radiol ; 27(1): 39-45, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26508449

RESUMO

PURPOSE: To assess the effectiveness of bland transarterial embolization of hepatocellular carcinoma (HCC) as a "bridge" to transplantation. MATERIALS AND METHODS: In this retrospective study, 117 patients with HCC that met Milan criteria underwent bland embolization as their initial and sole therapy for treatment of HCC (88 men and 29 women; mean age, 60.4 y; range, 35-88 y). Subsequent postembolization contrast-enhanced computed tomography or magnetic resonance imaging studies were reviewed to determine whether Milan criteria were met in an intent-to-transplant analysis. Freedom from progression beyond Milan criteria and survival were calculated by Kaplan-Meier technique. Predictors of progression and survival were also assessed. RESULTS: After embolization, 87% and 78% of patients' disease still met Milan criteria at 6 and 12 months, respectively. The median time until disease progression beyond Milan criteria was 22.6 months (95% confidence interval, 16.2-29 mo). α-Fetoprotein levels, number of lesions, United Network for Organ Sharing stage, Model for End-stage Liver Disease score, and cirrhosis etiology did not correlate significantly with stability within Milan criteria. A total of 34 patients (29%) underwent eventual liver transplantation at a median of 3.3 months (range, 0.5-20.9 mo). Liver transplantation was a significant independent predictor of longer survival (6.9 y vs 2.6 y; P < .001). The major complication rate within 30 days of embolization was 2.6%, including one mortality. CONCLUSIONS: Bland transarterial embolization as a bridging strategy to maintain HCC within Milan criteria was successful in 78% of patients at 1 year, which compares favorably with other locoregional embolotherapies.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Transplante de Fígado , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento
16.
J Vasc Interv Radiol ; 26(11): 1673-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26403274

RESUMO

PURPOSE: To determine postintervention patency rates after endovascular interventions on intragraft stenosis within failing prosthetic arteriovenous (AV) grafts, as well as predictors of patency. MATERIALS AND METHODS: Retrospective review of percutaneous interventions on prosthetic AV grafts presenting with first-time intragraft stenoses over a 7-year period revealed 183 patients (81 male; mean age, 59.7 y). "Intragraft" was defined as 2 cm or more from the arterial or venous anastomosis. Procedural imaging was retrospectively reviewed. Patency rates were estimated by Kaplan-Meier test. Predictors of patency were calculated by Cox proportional-hazards model. RESULTS: Two-hundred twenty-nine intragraft stenoses were identified in 183 grafts. Intragraft stenoses were treated at a median of 20.7 months (interquartile range, 12.0-33.9 mo) after graft creation. Graft thrombosis was present in 62%. The anatomic success rate of angioplasty was 85%. Fifteen percent required stent or stent-graft deployment because of inadequate response to angioplasty. A concurrent nonintragraft stenosis within the access circuit was identified in 76% of grafts. At 3, 6, and 12 months, postintervention primary patency rates were 56%, 40%, and 23%, respectively. Secondary patency rates were 84%, 77%, and 67%, respectively. The lesion-specific patency rates were 89, 75%, and 63%, respectively. Graft thrombosis (hazard ratio [HR], 1.43; P = .048) and concurrent nonintragraft lesion (HR, 1.51; P = .047) were independent negative predictors of primary patency. Graft thrombosis (HR, 1.81; P = .029) was a negative predictor of lesion patency, and stent or stent-graft deployment (HR, 0.42; P = .045) was a positive predictor of lesion patency. CONCLUSIONS: Endovascular interventions on intragraft stenoses resulted in primary, secondary, and lesion-specific patency rates of 40%, 77%, and 75%, respectively, at 6 months. Stent or stent-graft deployment may prolong lesion patency.


Assuntos
Derivação Arteriovenosa Cirúrgica/estatística & dados numéricos , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/cirurgia , Rejeição de Enxerto/epidemiologia , Diálise Renal/estatística & dados numéricos , Trombose/epidemiologia , Adulto , Idoso , Causalidade , Comorbidade , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Rejeição de Enxerto/diagnóstico por imagem , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Prognóstico , Falha de Prótese , Radiografia , Estudos Retrospectivos , Medição de Risco , Trombose/diagnóstico por imagem , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
J Vasc Interv Radiol ; 25(11): 1801-6, 1807.e1-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25066590

RESUMO

PURPOSE: To determine if there was a difference in the level of knowledge about interventional radiology (IR) between medical students in preclinical years of training compared with medical students in clinical years of training at two medical schools and to compare awareness of IR based on the curriculum at each school: one with required radiology education and one without such a requirement. MATERIALS AND METHODS: An anonymous survey was distributed to students at two medical schools; the survey assessed knowledge of IR, knowledge of training pathways, and preferred methods to increase exposure. Responses of the preclinical and clinical groups were compared, and responses from the clinical groups at each school were compared. RESULTS: "Poor" or "fair" knowledge of IR was reported by 84% (n = 217 of 259) of preclinical students compared with 62% of clinical students (n = 110 of 177; P < .001). IR was being considered as a career by 11% of all students (15%, n = 40 of 259 preclinical; 5%, n = 9 of 177 clinical). The main reason respondents were not considering IR was "lack of knowledge" (65%, n = 136 of 210 preclinical; 20%, n = 32 of 162 clinical). Students in the clinical group at the institution with a required radiology rotation reported significantly better knowledge of IR than clinical students from the institution without a required clerkship (P = .017). CONCLUSIONS: There are significant differences in knowledge of IR between preclinical and clinical students. Required radiology education in the clinical years does increase awareness of IR.


Assuntos
Competência Clínica/estatística & dados numéricos , Radiologia Intervencionista/educação , Faculdades de Medicina , Estudantes de Medicina/estatística & dados numéricos , Coleta de Dados/métodos , Coleta de Dados/estatística & dados numéricos , Humanos , Internato e Residência/estatística & dados numéricos , North Carolina
18.
Clin Imaging ; 110: 110142, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696997

RESUMO

PURPOSE: The purpose of this study was to evaluate long-term morphologic changes occurring in the liver after TIPS creation with correlation with hepatic function to gain insight on the physiologic impact of TIPS on the liver. METHODS: This retrospective study included patients who underwent TIPS creation between 2005 and 2022 and had contrasted CT or MRI studies prior to and between 1 and 2 years post procedure. Strict exclusion criteria were applied to avoid confounding. Parenchymal volume and vessel measurements were assessed on the pre- and post-TIPS CT or MRI and MELD scores calculated. RESULTS: Of 580 patients undergoing TIPS creation, 65 patients (mean age, 55 years; 36 males) had pre-TIPS and post-TIPS imaging meeting inclusion criteria at median 16.5 months. After TIPS, the mean MELD score increased (12.9 to 15.4; p = 0.008) and total liver volume decreased (1730 to 1432 mL; p < 0.001). However, the magnitude of volume change did not correlate with MELD change. Neither portosystemic gradient nor TIPS laterality correlated with total or lobar hepatic volume changes or MELD changes. The main portal vein diameter increased (15.0 to 18.7 mm; p < 0.001). Thrombosis of the hepatic vein used for TIPS creation resulted in a mean increase in MELD of +4.1 compared to -2.1 in patients who had a patent and normal hepatic vein (p = 0.007). CONCLUSIONS: Given lack of correlation between portosystemic gradient, hepatic atrophy, hepatic function, and TIPS laterality, the alterations in portal flow dynamics after TIPS may not be impactful to hepatic function. However, hepatic vein patency after TIPS correlated with improved hepatic function.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Derivação Portossistêmica Transjugular Intra-Hepática , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Resultado do Tratamento
19.
J Vasc Interv Radiol ; 24(4): 543-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23462067

RESUMO

PURPOSE: To determine the outcomes of percutaneous interventions for prolonging the patency of the Hemodialysis Reliable Outflow (HeRO) device. MATERIALS AND METHODS: Between January 2007 and August 2011, 73 percutaneous interventions were performed on 26 HeRO devices in 25 patients. The graft was implanted in the upper arm with the outflow catheter tip in the superior vena cava or right atrium. Procedural reports, angiographic images, and clinical notes were retrospectively reviewed. The primary and secondary patency rates after intervention were calculated using the Kaplan-Meier method. RESULTS: The mean time from HeRO implantation to initial dysfunction or thrombosis was 171 days. In 60 (82%) procedures, the HeRO device was thrombosed. An intragraft stenosis was the most common lesion identified (59%; n = 43) followed by an arterial anastomosis stenosis identified in 18% (n = 13). In 22% (n = 16) of procedures in which the HeRO device was thrombosed, an underlying cause was not identified after thrombectomy. The 3-, 6-, and 12-month primary patency rates after intervention were 47%, 37%, and 26% for first-time interventions. The secondary patency rates were 80%, 70%, and 64%. The only complication was pulmonary embolism resulting in death 2 days after HeRO thrombectomy. CONCLUSIONS: Percutaneous interventions on thrombosed and failing HeRO devices yielded acceptable primary and secondary patency rates after intervention in these patients with few, if any, alternatives for hemodialysis access.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateteres Venosos Centrais , Procedimentos Endovasculares , Oclusão de Enxerto Vascular/terapia , Diálise Renal , Trombose Venosa Profunda de Membros Superiores/terapia , Extremidade Superior/irrigação sanguínea , Angiografia Digital , Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Constrição Patológica , Desenho de Equipamento , Falha de Equipamento , Feminino , Fibrinolíticos/administração & dosagem , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Trombectomia , Terapia Trombolítica , Fatores de Tempo , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do Tratamento , Trombose Venosa Profunda de Membros Superiores/diagnóstico , Trombose Venosa Profunda de Membros Superiores/etiologia , Trombose Venosa Profunda de Membros Superiores/fisiopatologia , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA