Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Bioeth ; 24(6): 16-26, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38829597

RESUMO

Donation after circulatory determination of death (DCDD) is an accepted practice in the United States, but heart procurement under these circumstances has been debated. Although the practice is experiencing a resurgence due to the recently completed trials using ex vivo perfusion systems, interest in thoracoabdominal normothermic regional perfusion (TA-NRP), wherein the organs are reanimated in situ prior to procurement, has raised many ethical questions. We outline practical, ethical, and equity considerations to ensure transplant programs make well-informed decisions about TA-NRP. We present a multidisciplinary analysis of the relevant ethical issues arising from DCDD-NRP heart procurement, including application of the Dead Donor Rule and the Uniform Definition of Death Act, and provide recommendations to facilitate ethical analysis and input from all interested parties. We also recommend informed consent, as distinct from typical "authorization," for cadaveric organ donation using TA-NRP.


Assuntos
Transplante de Coração , Perfusão , Obtenção de Tecidos e Órgãos , Humanos , Transplante de Coração/ética , Obtenção de Tecidos e Órgãos/ética , Preservação de Órgãos/ética , Estados Unidos , Doadores de Tecidos/ética , Consentimento Livre e Esclarecido/ética , Morte , Cadáver
2.
J Surg Res ; 283: 699-704, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36462379

RESUMO

INTRODUCTION: Retrograde cerebral perfusion (RCP) is a safe and effective technique to augment cerebral protection during lower body circulatory arrest in patients undergoing elective hemiarch replacement. However, recommendations guiding optimal temperature, flow rate, and perfusion pressure are outdated and potentially overly limiting. We report our experience using RCP for elective hemiarch replacement with parameters that challenge the currently accepted paradigm. METHODS: This was a single-center, retrospective analysis of 319 adult patients who underwent elective hemiarch replacement between February 2010 and 2021 using hypothermic lower body circulatory arrest with RCP alone, RCP followed by antegrade cerebral perfusion (ACP), or ACP alone. Flow rates were adjusted to maintain cerebral perfusion pressure between 30 and 50 mm Hg for RCP and between 40 and 60 mm Hg for ACP. RESULTS: RCP was used in 22.6% (n = 72) of cases, whereas ACP alone was performed in 77.4% (n = 247) of cases. Baseline patient characteristics were similar between groups. Patients undergoing RCP demonstrated shorter cross-clamp time (97.0 min versus 100.0 min, P = 0.034) and shorter lower body circulatory arrest time (7.0 min versus 10.0 min, P < 0.0001) compared with ACP alone. Nadir bladder temperature was equivalent between groups (27.3°C versus 27.5°C, P = 0.752). There were no significant differences in postoperative complications, neurologic outcomes, or mortality. CONCLUSIONS: Moderate hypothermic lower body circulatory arrest combined with RCP at target perfusion pressures of 30-50 mm Hg in patients undergoing elective hemiarch replacement results in equivalent neurologic outcomes and overall morbidity to cases using ACP alone. These results challenge the currently accepted paradigm for RCP, which typically uses deep hypothermia while keeping perfusion pressures below 25 mm Hg.


Assuntos
Parada Cardíaca , Hipotermia Induzida , Adulto , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Parada Circulatória Induzida por Hipotermia Profunda , Perfusão/métodos , Circulação Cerebrovascular , Aorta Torácica/cirurgia , Hipotermia Induzida/métodos
3.
Perfusion ; : 2676591231182248, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37295776

RESUMO

INTRODUCTION: Post-infarction ventricular septal defect formation remains a formidable mechanical complication of acute myocardial infarction associated with increased morbidity and mortality. CASE PRESENTATION: We describe the case of a 72-year-old male who was admitted with post-myocardial infarction ventricular septal defect and cardiogenic shock. DISCUSSION: Impella 5.5 with SmartAssist as temporary left ventricular assist device provided sufficient support throughout multiple bridging episodes including failed percutaneous repair and subsequent definitive surgical repair. Contemporary management of post-infarction ventricular septal defect is discussed.

4.
J Physiol ; 598(13): 2575-2587, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32347547

RESUMO

KEY POINTS: Despite growing interest in right ventricular form and function in diseased states, there is a paucity of data regarding characteristics of right ventricular function - namely contractile and lusitropic reserve, as well as ventricular-arterial coupling, in the healthy heart during rest, as well as submaximal and peak exercise. Pressure-volume analysis of the right ventricle, during invasive cardiopulmonary exercise testing, demonstrates that that the right heart has enormous contractile reserve, with a three- or fourfold increase in all metrics of contractility, as well as myocardial energy production and utilization. The healthy right ventricle also demonstrates marked augmentation in lusitropy, indicating that diastolic filling of the right heart is not passive. Rather, the right ventricle actively contributes to venous return during exercise, along with the muscle pump. Ventricular-arterial coupling is preserved during submaximal and peak exercise in the healthy heart. ABSTRACT: Knowledge of right ventricular (RV) function has lagged behind that of the left ventricle and historically, the RV has even been referred to as a 'passive conduit' of lesser importance than its left-sided counterpart. Pressure-volume (PV) analysis is the gold standard metric of assessing ventricular performance. We recruited nine healthy sedentary individuals free of any cardiopulmonary disease (42 ± 12 years, 78 ± 11 kg), who completed invasive cardiopulmonary exercise testing during upright ergometry, while using conductance catheters inserted into the RV to generate real-time PV loops. Data were obtained at rest, two submaximal levels of exercise below ventilatory threshold, to simulate real-world scenarios/activities of daily living, and maximal effort. Breath-by-breath oxygen uptake was determined by indirect calorimetry. During submaximal and peak exercise, there were significant increases in all metrics of systolic function by three- to fourfold, including cardiac output, preload recruitable stroke work, and maximum rate of pressure change in the ventricle (dP/dtmax ), as well as energy utilization as determined by stroke work and pressure-volume area. Similarly, the RV demonstrated a significant, threefold increase in lusitropic reserve throughout exercise. Ventricular-arterial coupling, defined by the quotient of end-systolic elastance and effective arterial elastance, was preserved throughout all stages of exercise. Maximal pressures increased significantly during exercise, while end-diastolic volumes were essentially unchanged. Overall, these findings demonstrate that the healthy RV is not merely a passive conduit, but actively participates in cardiopulmonary performance during exercise by accessing an enormous amount of contractile and lusitropic reserve, ensuring that VA coupling is preserved throughout all stages of exercise.


Assuntos
Ventrículos do Coração , Disfunção Ventricular Direita , Atividades Cotidianas , Coração , Humanos , Volume Sistólico , Função Ventricular Direita
5.
J Card Surg ; 35(10): 2512-2521, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32789912

RESUMO

INTRODUCTION: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is utilized as a life-saving procedure and bridge to myocardial recovery for patients in refractory cardiogenic shock. Despite technical advancements, VA-ECMO retains high mortality. This study aims to identify the clinical predictors of in-hospital mortality after VA-ECMO to improve risk stratification for this tenuous patient population. METHODS: The REgistry for Cardiogenic Shock: Utility and Efficacy of Device Therapy database is a multicenter, observational registry of ECMO patients. From 2013 to 2018, 789 patients underwent VA-ECMO. Bivariate analysis was performed on more than 300 variables regarding their association with in-hospital mortality. Logistic regression analyses were performed with variables chosen based upon clinical and statistical significance in the bivariate analysis. Tests were considered significant at a two-sided P < .05. RESULTS: Although 63.5% patients were successfully weaned from VA-ECMO, in-hospital mortality was 57.9%. Nonsurvivors were older (P < .0001), had higher body mass index (P = .01), higher rates of hypertension (P = .02), coronary artery disease (P = .02), chronic obstructive pulmonary disease (P = .02), chronic liver disease (P = .008), percutaneous coronary intervention (P = .02), and surgical revascularization (P = .02). Multivariate predictors for in-hospital mortality include older age (odds ratio [OR], 1.019; P = .007), cardiac arrest (OR, 2.76; P = .006), chronic liver disease (OR, 8.87; P = .04), elevated total bilirubin (OR, 1.093; P < .0001), and the presence of a left ventricular vent (OR, 2.018; P = .03). Pre-ECMO sinus rhythm was protective (OR, 0.374; P = .006). CONCLUSIONS: In a large study of recent VA-ECMO patients, in-hospital mortality remains significant, but acceptable given the severe pathology manifested in this population. Identification of pre-ECMO predictors of mortality helps stratify high-risk patients when deciding on ECMO placement, prolonged support, and prognosis.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Oxigenação por Membrana Extracorpórea/métodos , Mortalidade Hospitalar , Choque Cardiogênico/mortalidade , Choque Cardiogênico/terapia , Adulto , Fatores Etários , Idoso , Índice de Massa Corporal , Comorbidade , Doença da Artéria Coronariana/epidemiologia , Bases de Dados Factuais , Feminino , Humanos , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Risco , Choque Cardiogênico/epidemiologia
6.
Heart Surg Forum ; 23(2): E107-E113, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-32364893

RESUMO

OBJECTIVE: Hybrid repair procedures of the aortic arch have been utilized to reduce surgical risks and apply this therapy to patients who would not traditionally be candidates for open surgical repair.  We present a variation on the frozen elephant trunk technique to further reduce cardiopulmonary bypass and circulatory arrest duration. METHODS: After initiation of cardiopulmonary bypass and during systemic cooling, a wire is advanced from the femoral artery into the aortic arch.  In the case of aortic dissection, intravascular ultrasound is used to confirm true lumen placement.  Under circulatory arrest, the proximal aortic arch is resected and the wire externalized.  Antegrade deployment of a stent graft is performed into the aortic arch and proximal descending aorta.  The ascending aortic graft is sewn to the cut end of the aorta, incorporating the stent graft.  The graft is cannulated and cardiopulmonary bypass reinitiated.  The remainder of the arch replacement is performed during re-warming. RESULTS: Twenty two patients underwent this novel hybrid arch replacement procedure for aortic pseudoaneurysm, aortic dissection, or aneurysm.  In comparison to the frozen elephant trunk procedure, where a dacron graft is inserted into the descending aorta, and later fixed with an endograft, this technique allows for immediate distal fixation.  In the case of aortic dissection, there is immediate expansion of the true lumen with distal seal, potentially obviating the need for additional procedures.  Mean duration of follow up is 12 months (range 1 - 14 months).  The mean duration of cardiopulmonary bypass was 109.32 ±3.14 minutes.  The mean duration of circulatory arrest was 18.00 ±1.33 minutes at a mean temperature of 23.64 ±0.58 degrees Celsius.  There were no mortalities, no permanent disabling strokes, and no renal failure (requiring dialysis). CONCLUSIONS: This novel hybrid technique for aortic arch replacement is safe, significantly reduces cardiopulmonary bypass and circulatory arrest times, and is performed readily without need for fluoroscopy.  In patients with thoracoabdominal aneurysms, the stent graft can be used as an elephant trunk for further thoracoabdominal aneurysm repair or branched thoracic endovascular aortic repair procedures.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Parada Circulatória Induzida por Hipotermia Profunda/métodos , Stents , Dissecção Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
7.
Heart Fail Clin ; 16(3): 295-303, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32503753

RESUMO

Continuous-flow left ventricular assist devices are frequently used for management of patients with advanced heart failure with reduced ejection fraction. Although technologic advancements have contributed to improved outcomes, several complications arise over time. These complications result from several factors, including medication effects, physiologic responses to chronic exposure to circulatory support that is minimally/entirely nonpulsatile, and dysfunction of the device itself. Clinical presentation can range from chronic and indolent to acute, life-threatening emergencies. Several areas of uncertainty exist regarding best practices for managing complications; however, growing awareness has led to development of new guidelines to reduce risk and improve outcomes.


Assuntos
Tratamento de Emergência/métodos , Insuficiência Cardíaca , Coração Auxiliar , Choque Cardiogênico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
8.
J Surg Res ; 242: 40-46, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31063910

RESUMO

BACKGROUND: Acute kidney injury (AKI) following open aortic arch surgery is a frequent complication associated with increased morbidity and mortality. The primary purpose of this study was to evaluate risk factors for postoperative AKI in patients who underwent open aortic arch surgery utilizing hypothermic circulatory arrest (HCA). MATERIALS AND METHODS: Included were 295 patients undergoing surgery between January 2011 and March 2018. AKI was defined according to Kidney Disease: Improving Global Outcomes guidelines. Preoperative and intraoperative variables were stratified by no AKI versus any AKI, and bivariate analysis was performed. Multivariable logistic regression analysis used statistically and clinically significant characteristics from the bivariate analysis. RESULTS: Of the 295 patients, 93 (32%) developed AKI. In the bivariate analysis, significant predictors of AKI included the following: history of hypertension (P < 0.001), diabetes (P = 0.03), operative urgency (P = 0.009), cardiopulmonary bypass (CPB) time (P < 0.0001), HCA time (0.02), total intraoperative transfusions (P = 0.002), and concomitant procedures (coronary artery bypass grafting, or mitral/tricuspid interventions, P = 0.0009). In the multivariable analysis, significant predictors of AKI were history of hypertension (P = 0.03) and CPB time (P = 0.02). Age, operative urgency, circulatory arrest time, and any intraoperative transfusion were not significant in the multivariable analysis. CONCLUSION: In conclusion, given that CPB time is the only modifiable risk factor identified in the analysis, approaches to reducing bypass time should continue to be the focus of decreasing risk for postoperative AKI in HCA cases.


Assuntos
Injúria Renal Aguda/diagnóstico , Aorta Torácica/cirurgia , Ponte Cardiopulmonar/efeitos adversos , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Adulto , Idoso , Transfusão de Sangue/estatística & dados numéricos , Ponte Cardiopulmonar/estatística & dados numéricos , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Retrospectivos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Card Surg ; 31(7): 456-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27183897

RESUMO

Proximal aortic pathology provides a technical challenge for endovascular repair. We present a case of successful transapical endovascular aortic repair in a patient with a proximal suture line pseudoaneurysm who was not a candidate for open surgical repair. doi: 10.1111/jocs.12766 (J Card Surg 2016;31:456-460).


Assuntos
Falso Aneurisma/cirurgia , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares/métodos , Idoso , Dissecção Aórtica , Feminino , Humanos , Stents , Resultado do Tratamento
10.
J Card Surg ; 31(10): 654-657, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27487763

RESUMO

The development of new aortic insufficiency after a period of support with a left ventricular assist device can result in progressive heart failure symptoms. Transcatheter aortic valve repair can be an effective treatment in selected patients, but the lack of aortic valve calcification can result in unstable prostheses or paravalvular leak. We describe a technique of deploying a self-expanding CoreValve (Medtronic, Minneapolis, MN, USA) into the aortic annulus, followed by a balloon-expandable SAPIEN-3 (Edwards, Irvine, CA, USA).


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/cirurgia , Próteses Valvulares Cardíacas , Coração Auxiliar , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Angiografia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Ecocardiografia , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Card Surg ; 30(10): 771-4, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26286927

RESUMO

INTRODUCTION: Mechanical circulatory support for heart failure, including the Total Artificial Heart (TAH, Syncardia, Tucson, AZ, USA) has increased in recent years. This report describes bleeding complications associated with the device. METHODS: A single institution prospectively maintained quality improvement database was reviewed encompassing the first year of clinical experience with the TAH. Patients who underwent TAH implantation were identified, and a review of complications and outcomes was undertaken. RESULTS: Ten patients underwent TAH implant. Four patients experienced delayed postoperative bleeding. In three patients the manifestation of bleeding was tamponade and evidenced by TAH decreased cardiac output. In two patients, at postoperative days 31 and 137, there was a partial disruption of the aortic anastomosis along the outer curvature with pseudoaneurysm formation. Both were repaired by primary suture closure, without use of cardiopulmonary bypass. There was no mortality attributable to bleeding. CONCLUSIONS: TAH patients are at risk for delayed postoperative bleeding, often manifest as an acute decrease in cardiac output. Due to pulsatility and high dP/dT, bleeding from the aortic anastomosis should be considered in the differential of a patient with low flow and/or tamponade.


Assuntos
Perda Sanguínea Cirúrgica , Insuficiência Cardíaca/cirurgia , Coração Artificial/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Baixo Débito Cardíaco , Tamponamento Cardíaco , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Heart Lung Transplant ; 43(6): 996-998, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342158

RESUMO

Racial and ethnic disparities in provision of left ventricular assist device (LVAD) therapy have been identified. These disparities may be at least partially related to socioeconomic factors, including social support networks and financial constraints. This study aimed to identify specific barriers, and variations in institutional approaches, to the provision of equitable care to underserved populations. A survey was administered to 237 LVAD program personnel, including physicians, LVAD coordinators, and social workers, at more than 100 LVAD centers across 7 countries. Three fourths of respondents reported that their program required a support person to live with the LVAD patient for some period of time following implantation. In addition, 31% of respondents reported that patients with the inability to pay for medications are turned down at their program. The most significant barriers to successful LVAD implantation were lack of social support, lack of insurance, and lack of timely referral. The most consistently identified supports needed from the hospital system for success in underserved populations were the provision of a solution for patient transportation to and from hospital visits and the provision of financial support. This survey highlights the challenges facing LVAD programs that care for underserved patient populations and sets the stage for specific interventions aimed at reducing disparities in access to care.


Assuntos
Acessibilidade aos Serviços de Saúde , Coração Auxiliar , Apoio Social , Humanos , Insuficiência Cardíaca/terapia , Inquéritos e Questionários , Masculino , Disparidades em Assistência à Saúde , Feminino , Fatores Socioeconômicos
14.
Cardiovasc Eng Technol ; 14(4): 560-576, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37340092

RESUMO

Left ventricular assist device (LVAD) provides mechanical circulatory support for patients with advanced heart failure. Treatment using LVAD is commonly associated with complications such as stroke and gastro-intestinal bleeding. These complications are intimately related to the state of hemodynamics in the aorta, driven by a jet flow from the LVAD outflow graft that impinges into the aorta wall. Here we conduct a systematic analyses of hemodynamics driven by an LVAD with a specific focus on viscous energy transport and dissipation. We conduct a complementary set of analysis using idealized cylindrical tubes with diameter equivalent to common carotid artery and aorta, and a patient-specific model of 27 different LVAD configurations. Results from our analysis demonstrate how energy dissipation is governed by key parameters such as frequency and pulsation, wall elasticity, and LVAD outflow graft surgical anastomosis. We find that frequency, pulsation, and surgical angles have a dominant effect, while wall elasticity has a weaker effect, in determining the state of energy dissipation. For the patient-specific scenario, we also find that energy dissipation is higher in the aortic arch and lower in the abdominal aorta, when compared to the baseline flow without an LVAD. This further illustrates the key hemodynamic role played by the LVAD outflow jet impingement, and subsequent aortic hemodynamics during LVAD operation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Aorta Torácica/cirurgia , Hemodinâmica , Insuficiência Cardíaca/cirurgia , Aorta Abdominal
15.
Ann Biomed Eng ; 51(6): 1226-1243, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36705866

RESUMO

Left ventricular assist devices (LVADs) comprise a primary treatment choice for advanced heart failure patients. Treatment with LVAD is commonly associated with complications like stroke and gastro-intestinal (GI) bleeding, which adversely impacts treatment outcomes, and causes fatalities. The etiology and mechanisms of these complications can be linked to the fact that LVAD outflow jet leads to an altered state of hemodynamics in the aorta as compared to baseline flow driven by aortic jet during ventricular systole. Here, we present a framework for quantitative assessment of aortic hemodynamics in LVAD flows realistic human vasculature, with a focus on quantifying the differences between flow driven by LVAD jet and the physiological aortic jet when no LVAD is present. We model hemodynamics in the aortic arch proximal to the LVAD outflow graft, as well as in the abdominal aorta away from the LVAD region. We characterize hemodynamics using quantitative descriptors of flow velocity, stasis, helicity, vorticity and mixing, and wall shear stress. These are used on a set of 27 LVAD scenarios obtained by parametrically varying LVAD outflow graft anastomosis angles, and LVAD flow pulse modulation. Computed descriptors for each of these scenarios are compared against the baseline flow, and a detailed quantitative characterization of the altered state of hemodynamics due to LVAD operation (when compared to baseline aortic flow) is compiled. These are interpreted using a conceptual model for LVAD flow that distinguishes between flow originating from the LVAD outflow jet (and its impingement on the aorta wall), and flow originating from aortic jet during aortic valve opening in normal physiological state.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Modelos Cardiovasculares , Aorta , Aorta Torácica/fisiologia , Hemodinâmica
16.
medRxiv ; 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37609263

RESUMO

Stroke remains a leading cause of complications and mortality in heart failure patients treated with LVAD circulatory support. Hemodynamics plays a central role in affecting risk and etiology of stroke during LVAD support. Yet, detailed quantitative assessment of hemodynamic variables and their relation to stroke outcomes in patients with an implanted LVAD remains a challenge. We present an in silico hemodynamics analysis in a set of 12 patients on LVAD support; 6 with reported stroke outcomes and 6 without. We conducted patient-specific hemodynamics simulations for models with the LVAD outflow graft reconstructed from cardiac-gated CT images. A pre-implantation baseline flow model was virtually generated for each case by removing the LVAD outflow graft and driving flow from the aortic root. Hemodynamics was characterized using quantitative descriptors for helical flow, vortex generation, and wall shear stress. Our analysis showed higher average values for descriptors of positive helical flow, vortex generation, and wall shear stress, across the 6 cases with stroke outcomes on LVAD support, when compared with cases without stroke. When the descriptors for LVAD-driven flow were compared against estimated baseline flow pre-implantation, extent of positive helicity was higher, and vorticity and wall shear were lower in cases with stroke compared to those without. The study suggests that quantitative analysis of hemodynamics after LVAD implantation; and hemodynamic alterations from a pre-implant flow scenario, can potentially reveal hidden information linked to stroke outcomes during LVAD support. This has broad implications on understanding stroke etiology, LVAD treatment planning, surgical optimization, and efficacy assessment.

17.
Cardiol Young ; 22(1): 103-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21729498

RESUMO

A 7-year-old child was noted to have dextrojuxtaposition of the left atrial appendage at the time of surgical atrial septal defect repair. Given the favourable anatomic location and size of the atrial appendage, it was inverted and used to close the atrial defect. This is the first report of atrial septal defect repair using a juxtaposed atrial appendage. The cardiac anatomy and theoretical benefits of this repair are discussed.


Assuntos
Apêndice Atrial/anormalidades , Apêndice Atrial/cirurgia , Comunicação Interatrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Feminino , Humanos
18.
JAMA Cardiol ; 7(6): 651-654, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35475896

RESUMO

Importance: Orthotopic heart transplant (OHT) recipients are at increased risk for morbidity and mortality after SARS-CoV-2 infection. Although antibody response to COVID-19 vaccination is lower in solid organ transplant recipients, there has been no study assessing the safety and effectiveness of COVID-19 vaccination in OHT recipients. Objective: To assess the safety and effectiveness of COVID-19 vaccination and associations with SARS-CoV-2 infection and clinical outcomes in a large population of adult OHT recipients. Design, Setting, and Participants: This case-control study examined data from a US heart transplant program at a single center for all adult recipients of OHT who were followed up from January 15, 2021, through January 31, 2022. Main Outcomes and Measures: The primary outcome was number of SARS-CoV-2 infections and related hospitalizations, intensive care unit (ICU) admissions, and deaths between vaccinated vs unvaccinated adult recipients of OHT. Results: A total of 436 patients who received OHT were included in the study, of which 106 patients were infected with COVID-19. The mean (SD) age was 54 (17) years; 303 (69.5%) were men and 133 (30.5%) were women. There were 366 patients in the vaccinated cohort with 72 COVID-19 infections (19.7%), 15 hospitalizations (4.1%), 4 ICU admissions (1.1%), and 3 deaths (0.8%). There were 70 patients in the unvaccinated cohort with 34 COVID-19 infections (48.6%), 10 hospitalizations (14.3%), 3 ICU admissions (4.3%), and 3 deaths (4.3%). COVID-19 vaccination was associated with a lower risk of COVID-19 infection (risk ratio [RR], 0.41; 95% CI, 0.30-0.56), hospitalization (RR, 0.29; 95% CI, 0.14-0.61), and death (RR, 0.19; 95% CI, 0.05-0.82). Among the 366 vaccinated OHT recipients, there was no echocardiographic evidence of graft dysfunction, clinically significant rejection, or allosensitization at 6 months after they received the COVID-19 vaccine. Conclusions and Relevance: Patients with OHT who are infected with SARS-CoV-2 are at greater risk of severe infection and death compared with immunocompetent individuals. COVID-19 vaccination was associated with fewer COVID-19 infections, hospitalizations, and deaths, with no heart transplant-specific adverse events. COVID-19 vaccination for all OHT recipients is of paramount importance.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Transplante de Coração , Adulto , Idoso , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Estudos de Casos e Controles , Feminino , Transplante de Coração/mortalidade , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2 , Vacinação
19.
J Thorac Cardiovasc Surg ; 163(4): 1378-1387, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-32739165

RESUMO

OBJECTIVES: Baseline kidney function is a key predictor of postoperative morbidity and mortality. Whether an increased creatinine at the time of surgery, compared with the lowest creatinine in the 3 months before surgery, is associated with poor outcomes has not been evaluated. We examined whether creatinine elevations from "baseline" were associated with adverse postoperative outcomes. METHODS: A total of 1486 patients who underwent cardiac surgery at the University of Colorado Hospital between January 2011 and May 2016 met inclusion criteria. "Change in creatinine from baseline" was defined as the difference between the immediate presurgical creatinine value and the lowest creatinine value within 3 months preceding surgery. Outcomes evaluated were in-hospital mortality, postoperative infection, postoperative stroke, development of stage 3 acute kidney injury, intensive care unit length of stay, and hospital length of stay. Outcomes were adjusted using a balancing score to account for differences in patient characteristics. RESULTS: There were significant increases in the odds of postoperative infection (odds ratio, 1.17; confidence interval, 1.02-1.34; per 0.1 mg/dL increase in creatinine), stage 3 acute kidney injury (odds ratio, 1.44; confidence interval; 1.18-1.75), intensive care unit length of stay (odds ratio, 1.13; confidence interval, 1.01-1.26), and hospital length of stay (odds ratio, 1.09; confidence interval, 1.05-1.13). There was a significant increase in mortality in the unadjusted analysis, although not after adjustment using a balancing score. There was no association with postoperative stroke. CONCLUSIONS: Elevations in creatinine at the time of surgery above the "baseline" level are associated with increased postoperative morbidity. Baseline creatinine should be established before surgery, and small changes in creatinine should trigger heightened vigilance in the postoperative period.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Creatinina/análise , Complicações Pós-Operatórias , Injúria Renal Aguda/epidemiologia , Biomarcadores/análise , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Front Cardiovasc Med ; 9: 1029825, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36407458

RESUMO

Over the last two decades, implantable continuous flow left ventricular assist devices (LVAD) have proven to be invaluable tools for the management of selected advanced heart failure patients, improving patient longevity and quality of life. The presence of concomitant valvular pathology, including that involving the tricuspid, mitral, and aortic valve, has important implications relating to the decision to move forward with LVAD implantation. Furthermore, the presence of concomitant valvular pathology often influences the surgical strategy for LVAD implantation. Concomitant valve repair or replacement is not uncommonly required in such circumstances, which increases surgical complexity and has demonstrated prognostic implications both short and longer term following LVAD implantation. Beyond the index operation, it is also well established that certain valvular pathologies may develop or worsen over time following LVAD support. The presence of pre-existing valvular pathology or that which develops following LVAD implant is of particular importance to the destination therapy LVAD patient population. As these patients are not expected to have the opportunity for heart transplantation in the future, optimization of LVAD support including ameliorating valvular disease is critical for the maximization of patient longevity and quality of life. As collective experience has grown over time, the ability of clinicians to effectively address concomitant valvular pathology in LVAD patients has improved in the pre-implant, implant, and post-implant phase, through both medical management and procedural optimization. Nevertheless, there remains uncertainty over many facets of concomitant valvular pathology in advanced heart failure patients, and the understanding of how to best approach these conditions in the LVAD patient population continues to evolve. Herein, we present a comprehensive review of the current state of the field relating to the pathophysiology and management of valvular disease in destination LVAD patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA