Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Tipo de estudo
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Tex Heart Inst J ; 37(4): 465-8, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20844624

RESUMO

Coronary ostial stenosis is a rare but potentially serious sequela after aortic valve replacement. It occurs in the left main or right coronary artery after 1% to 5% of aortic valve replacement procedures. The clinical symptoms are usually severe and may appear from 1 to 6 months postoperatively. Although the typical treatment is coronary artery bypass grafting, patients have been successfully treated by means of percutaneous coronary intervention.Herein, we present the cases of 2 patients in whom coronary ostial stenosis developed after aortic valve replacement. In the 1st case, a 72-year-old man underwent aortic valve replacement and bypass grafting of the saphenous vein to the left anterior descending coronary artery. Six months later, he experienced a non-ST-segment-elevation myocardial infarction. Coronary angiography revealed a critical stenosis of the right coronary artery ostium. In the 2nd case, a 78-year-old woman underwent aortic valve replacement and grafting of the saphenous vein to an occluded right coronary artery. Four months later, she experienced unstable angina. Coronary angiography showed a critical left main coronary artery ostial stenosis and occlusion of the right coronary artery venous graft. In each patient, we performed percutaneous coronary intervention and deployed a drug-eluting stent. Both patients were asymptomatic on 6-to 12-month follow-up. We attribute the coronary ostial stenosis to the selective ostial administration of cardioplegic solution during surgery. We conclude that retrograde administration of cardioplegic solution through the coronary sinus may reduce the incidence of postoperative coronary ostial stenosis, and that stenting may be an efficient treatment option.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Valva Aórtica/cirurgia , Estenose Coronária/terapia , Stents Farmacológicos , Parada Cardíaca Induzida/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso , Angina Instável/etiologia , Angina Instável/terapia , Angiografia Coronária , Ponte de Artéria Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/etiologia , Feminino , Parada Cardíaca Induzida/métodos , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA